190518039EMC-1_FCC_Part_15B&_ICES-003_Class_B_Report

FCC ID: XAM500079GR01

Test Report

Download: PDF
FCCID_4461333

 Uni#nTrust                                                      Page 1 of 21                            Report No.: 190518039EMC—1




                                                  TEST REPORT

                                                  Product Name:               Smart Phone
                                                         Trade Mark:          ecom
                                                          Model No.:          Smart—Ex 02
                                                Add. Model No.:               N/A
                                                Report Number:                190518039EMC—1
                                                Test Standards:               FCC 47 CFR Part 15 Subpart B
                                                                              ICES—003 Issue 6
                                                             FCC ID:          XAM5OOO79GRO1
                                                                        IC:   8311A—500079GRO1
                                                         Test Result:         PASS
                                                    Date of Issue:            July 20, 2019


                                                                   Prepared for:


                                         ecom instruments GmbH
                             Industriestrasse 2, Assamstadt, 97959, Germany


                                                                   Prepared by:
                  Shenzhen UnionTrust Quality and Technology Co., Ltd.
            16/F, Block A, Building 6, Baoneng Science and Technology Park,
              Qingxiang Road No.1, Longhua New District, Shenzhen, China
                                                     TEL: +86—755—2823 0888
                                                     FAX: +86—755—2823 0886




                Prepared by:                  41 _(                                  Reviewed by:                   «ff——_—=~
                                                 Henfy Lu                                                           Kevin Liang

                                          4
                                              — Teakp Leader _                                                  Assistant Manager

                                         #1    1 §, \:              C


               Approved by:               *Ahs es                                              Date:               July 20, 2019
                                                         By Lies
                            Technical Director
Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/7F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86—755—28230888                   Fax: +86—755—28230886                  E—mail: info@uttlab.com                Hitp:/www.uttlab.com


                                                               Page 2 of 21                            Report No.: 190518039EMC-1

Version
      Version No.                          Date                                                   Description
           V1.0                       July 20, 2019                                                  Original




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                                          Page 3 of 21                                   Report No.: 190518039EMC-1



                                                                        CONTENTS
1.   GENERAL INFORMATION ....................................................................................................................................... 4
     1.1      CLIENT INFORMATION ........................................................................................................................................ 4
     1.2      EUT INFORMATION ............................................................................................................................................ 4
              1.2.1 GENERAL DESCRIPTION OF EUT ............................................................................................................ 4
              1.2.2 DESCRIPTION OF ACCESSORIES.............................................................................................................. 5
     1.3      DESCRIPTION OF SUPPORT UNITS ...................................................................................................................... 6
     1.4      TEST LOCATION ................................................................................................................................................. 6
     1.5      TEST FACILITY ................................................................................................................................................... 6
     1.6      DEVIATION FROM STANDARDS ............................................................................................................................ 6
     1.7      ABNORMALITIES FROM STANDARD CONDITIONS .................................................................................................. 7
     1.8      OTHER INFORMATION REQUESTED BY THE CUSTOMER ........................................................................................ 7
     1.9      MEASUREMENT UNCERTAINTY ........................................................................................................................... 7
2.   TEST SUMMARY ...................................................................................................................................................... 8
3.   EQUIPMENT LIST .................................................................................................................................................... 9
4.   TEST CONFIGURATION ........................................................................................................................................ 10
     4.1      ENVIRONMENTAL CONDITIONS FOR TESTING ...................................................................................................... 10
              4.1.1 NORMAL OR EXTREME TEST CONDITIONS ............................................................................................. 10
              4.1.2 RECORD OF NORMAL ENVIRONMENT..................................................................................................... 10
     4.2      TEST MODES ................................................................................................................................................... 10
     4.3      TEST SETUP .................................................................................................................................................... 11
              4.3.1 FOR RADIATED EMISSIONS TEST SETUP ................................................................................................ 11
              4.3.2 FOR CONDUCTED EMISSIONS TEST SETUP ............................................................................................ 12
     4.4      SYSTEM TEST CONFIGURATION ........................................................................................................................ 12
5.   REFERENCE DOCUMENTS FOR TESTING ......................................................................................................... 13
6.   EMC REQUIREMENTS SPECIFICATION .............................................................................................................. 13
     6.1      RADIATED EMISSION ........................................................................................................................................ 13
     6.2      CONDUCTED EMISSION .................................................................................................................................... 18
APPENDIX 1 PHOTOS OF TEST SETUP ..................................................................................................................... 21
APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS ................................................................................. 21




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 4 of 21                            Report No.: 190518039EMC-1

1. GENERAL INFORMATION
   1.1 CLIENT INFORMATION
        Applicant:                            ecom instruments GmbH
        Address of Applicant:                 Industriestrasse 2, Assamstadt, 97959, Germany
        Manufacturer:                         Pepperl+Fuchs GmbH
        Address of Manufacturer:              Lilienthalstrasse 200, 68307 Mannheim, Germany


      1.2 EUT INFORMATION
      1.2.1       General Description of EUT
        Product Name:                         Smart Phone
        Model No.:                            Smart-Ex 02
        Add. Model No.:                       N/A
        Trade Mark:                           ecom
        DUT Stage:                            Identical Prototype
                                              ☒ 110-240V~50/60Hz, 0.3A and/or
        Rated Voltage:                        3.7Vdc (1x3.7V Li-ion Rechargeable battery)
                                              ☒ Powered by POE port
        Classification of digital
                                              Class B
        devices:
        Highest Internal
                                              5825 MHz
        Frequency:
        Sample Received Date:                 May 20, 2019
        Sample Tested Date:                   June 17, 2019 to June 26, 2019




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 5 of 21                            Report No.: 190518039EMC-1

      1.2.2       Description of Accessories
                                                                       Adapter
        Model No.:                            S008ACM0500200
        Input:                                100-240 V~50/60 Hz 0.3 A Max
        Output:                               5.0 V   2A
        AC Cable:                             N/A
        DC Cable:                             N/A

                                                                      Battery (1)
        Model No.:                            EX-BP S02
        Battery Type:                         Lithium-ion Rechargeable Battery
        Rated Voltage:                        3.7 Vdc
        Rated Capacity:                       4400 mAh

                                                                      Battery (2)
        Model No.:                            EX-BP S02C
        Battery Type:                         Lithium-ion Rechargeable Battery
        Rated Voltage:                        3.7 Vdc
        Rated Capacity:                       3920 mAh

                                                                         Cable
        Description:                          USB Changing Cable
        Cable Type:                           Shielded without ferrite
        Length:                               1.2 Meter




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 6 of 21                            Report No.: 190518039EMC-1

      1.3 DESCRIPTION OF SUPPORT UNITS
       The EUT has been tested with associated equipment below.
       1) Support Equipment
           Description        Manufacturer           Model No.                                    Serial Number              Supplied by
              Notebook                      Lenovo                       E450                     SL10G10780                  UnionTrust
              Earphone                        MI                      HSEJ03JY                         N/A                    UnionTrust
               Mouse                         DELL                     MOCZUL                           N/A                    UnionTrust

       2) Support Cable
        Cable No.      Description                  Connector                            Length                              Supplied by
              --                   --                     --                                 --                                     --


      1.4 TEST LOCATION

       Shenzhen UnionTrust Quality and Technology Co., Ltd.

       Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New
       District, Shenzhen, China 518109
       Telephone: +86 (0) 755 2823 0888
       Fax: +86 (0) 755 2823 0886



      1.5 TEST FACILITY

       The test facility is recognized, certified, or accredited by the following organizations:

       CNAS-Lab Code: L9069
       The measuring equipment utilized to perform the tests documented in this report has been calibrated once a
       year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC/EN 17025
       to international or national standards. Equipment has been calibrated by accredited calibration laboratories.

       A2LA-Lab Certificate No.: 4312.01
       Shenzhen UnionTrust Quality and Technology Co., Ltd. has been accredited by A2LA for technical competence
       in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2005 General Requirements
       for the Competence of Testing and Calibration Laboratories and any additional program requirements in the
       identified field of testing.

       ISED Wireless Device Testing Laboratories
       CAB identifier: CN0032

       FCC Accredited Lab.
       Designation Number: CN1194
       Test Firm Registration Number: 259480



      1.6 DEVIATION FROM STANDARDS
       None.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 7 of 21                            Report No.: 190518039EMC-1

      1.7 ABNORMALITIES FROM STANDARD CONDITIONS
       None.

      1.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER
       None.

      1.9 MEASUREMENT UNCERTAINTY
       Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the
       Product as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at
       approximately the 95% confidence level using a coverage factor of k=2.
        No.                          Item                                    Measurement Uncertainty
          1               Conducted emission 9KHz-150KHz                                                      ±3.8 dB
          2              Conducted emission 150KHz-30MHz                                                      ±3.4 dB
          3                Radiated emission 9KHz-30MHz                                                       ±4.9 dB
          4                Radiated emission 30MHz-1GHz                                                       ±4.7 dB
          5                Radiated emission 1GHz-18GHz                                                       ±5.1 dB
          6                Radiated emission 18GHz-26GHz                                                      ±5.2 dB
          7                Radiated emission 26GHz-40GHz                                                      ±5.2 dB




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 8 of 21                            Report No.: 190518039EMC-1

2. TEST SUMMARY
                                               FCC 47 CFR Part 15 Subpart B Test Cases
                  Test Item                      Test Requirement                 Test Method                                         Result
                                               FCC 47 CFR Part 15.107
           Conducted Emission                                                   ANSI C63.4-2014                                        PASS
                                             ICES-003 Issue 6 Section 6.1
                                               FCC 47 CFR Part 15.109
            Radiated Emission                                                   ANSI C63.4-2014                                        PASS
                                             ICES-003 Issue 6 Section 6.2




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 9 of 21                            Report No.: 190518039EMC-1

3. EQUIPMENT LIST
                                                  Radiated Emission Test Equipment List
                                                                              Serial                        Cal. date            Cal. Due date
        Used            Equipment              Manufacturer   Model No.
                                                                             Number                       (mm dd, yyyy)         (mm dd, yyyy)
                     3M Chamber &
          ☒                                   ETS-LINDGREN               3M                N/A             Dec. 03, 2018         Dec. 03, 2021
                  Accessory Equipment
          ☒            Receiver                      R&S               ESIB26            100114            Nov. 24, 2018         Nov. 24, 2019
          ☐           Loop Antenna            ETS-LINDGREN              6502            00202525           Dec. 03, 2018         Dec. 03, 2019
          ☒        Broadband Antenna          ETS-LINDGREN            3142E             00201566           Dec. 08, 2018         Dec. 08, 2019
                                                                     RA6A5-N-
          ☒           6dB Attenuator                Talent                              18103001           Dec. 08, 2018         Dec. 08, 2019
                                                                        18
          ☒            Preamplifier                   HP              8447F           2805A02960           Nov. 24, 2018         Nov. 24, 2019
                      Horn Antenna
          ☒                                   ETS-LINDGREN            3117-PA           00201874           May 18, 2019          May 18, 2020
                      (Pre-amplifier)
                      Horn Antenna
          ☒                                   ETS-LINDGREN           3116C-PA           00202652           Jan. 05, 2019         Jan. 05, 2020
                      (Pre-amplifier)
                       Multi device
          ☒                                   ETS-LINDGREN            7006-001          00160105                N/A                   N/A
                        Controller
          ☒           Test Software                 Audix                 e3                       Software Version: 9.160333


                                                 Conducted Emission Test Equipment List
                                                                              Serial                        Cal. date            Cal. Due date
        Used            Equipment              Manufacturer  Model No.
                                                                             Number                       (mm dd, yyyy)         (mm dd, yyyy)
                                                                          1316.3003K07
          ☒              Receiver                 R&S          ESR7                                        Nov. 24, 2018         Nov. 24, 2019
                                                                           -101181-K3
          ☒            Pulse Limiter              R&S        ESH3-Z2      0357.8810.54                     Nov. 24, 2018         Nov. 24, 2019
          ☒                LISN                      R&S              ESH2-Z5         860014/024           Nov. 24, 2018         Nov. 24, 2019
          ☒           Test Software                 Audix                 e3                       Software Version: 9.160323




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 10 of 21                           Report No.: 190518039EMC-1

4. TEST CONFIGURATION
   4.1 ENVIRONMENTAL CONDITIONS FOR TESTING
      4.1.1       Normal or Extreme Test Conditions
        Environment Parameter                                              Selected Values During Tests
                                                                                     Ambient
              Test Condition
                                                Temperature (°C)                     Voltage            Relative Humidity (%)
                                                                                 AC 120V/60Hz or
                    NT/NV                            +15 to +35                                                20 to 75
                                                                                  AC 240V/50Hz
        Remark:
        1) NV: Normal Voltage; NT: Normal Temperature

      4.1.2       Record of Normal Environment
                                                   Temperature            Relative Humidity               Pressure
                    Test Item                                                                                                     Tested by
                                                      (°C)                       (%)                        (kPa)
             Conducted Emission                        25                         41                         99.8              Gemini Huang
              Radiated Emission                       25.2                        51                        98.89                Andy Lin


      4.2 TEST MODES
         Test Item                                             EMI Test Modes
                         Mode 1: Charging from 120 Vac + MP4 playing + With TF Card + Earphone + Battery(1)
                         Mode 2: Charging from 120 Vac + Camera (Front) + With TF Card + Battery(1)
         Radiated        Mode 3: Charging from 120 Vac + Camera (Rear) + With TF Card + Battery(1)
         Emission        Mode 4: Charging from 240 Vac + Worse from mode 1~3
                         Mode 5: USB Cable (data transfer with notebook) + With TF Card + Battery(1)
                         Mode 6: Worse from mode 1~5 + Battery(2)
                         Mode 1: Charging from 120 Vac + MP4 playing + With TF Card + Earphone + Battery(1)
                         Mode 2: Charging from 120 Vac + Camera (Front) + With TF Card + Battery(1)
        Conducted        Mode 3: Charging from 120 Vac + Camera (Rear) + With TF Card + Battery(1)
         Emission        Mode 4: Charging from 240 Vac + Worse from mode 1~3
                         Mode 5: USB Cable (data transfer with notebook) + With TF Card + Battery(1)
                         Mode 6: Worse from mode 1~5 + Battery(2)




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 11 of 21                           Report No.: 190518039EMC-1

      4.3 TEST SETUP
      4.3.1       For Radiated Emissions test setup
                                                            Figure 1. 30MHz to 1GHz




                                                               Figure 2. Above 1GHz




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 12 of 21                           Report No.: 190518039EMC-1

      4.3.2       For Conducted Emissions test setup
                                                     Figure 3. Conducted Emissions setup




      4.4 SYSTEM TEST CONFIGURATION
       All readings are extrapolated back to the equivalent three meter reading using inverse scaling with distance.
       Analyzer resolution is 100 kHz or greater for frequencies below 1000MHz. The resolution is 1 MHz or greater for
       frequencies above 1000MHz. The spurious emissions more than 20 dB below the permissible value are not
       reported.
       Radiated emission measurement were performed from the lowest radio frequency signal generated in the device
       which is greater than 9 kHz to the tenth harmonic (according to KDB 896810 D02 SDoC FAQ v01r01) of the
       highest fundamental frequency or to 40 GHz, whichever is lower.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 13 of 21                           Report No.: 190518039EMC-1

5. REFERENCE DOCUMENTS FOR TESTING
         No.                    Identity                                                     Document Title
          1       FCC 47 CFR Part15 Subpart B               Unintentional Radiators
                                                            Information Technology Equipment (Including Digital Apparatus)
          2               ICES-003 Issue 6
                                                            —Limits and Methods of Measurement
                                                            American National Standard for Methods of Measurement of
          3               ANSI C63.4-2014                   Radio-Noise Emissions from Low-Voltage Electrical and Electronic
                                                            Equipment in the Range of 9 kHz to 40 GHz
          4          KDB 174176 D01 Line                    AC power-line conducted emission frequency asked questions
                     Conducted FAQ v01r01
          5        KDB 896810 D02 SDoC FAQ                  Supplier’s Declaration of Conformity frequency asked questions
                            v01r02

6. EMC REQUIREMENTS SPECIFICATION
   6.1 RADIATED EMISSION
                                    FCC 47 CFR Part 15.109
        Test Requirement:
                                    ICES-003 Issue 6 Clause 6.2
        Test Method:                ANSI C63.4-2014
        Receiver Setup:
              Frequency: (f)                                                             Measurement receiver bandwidth
                                                  Detector type
                  (MHz)                                                                   RBW                    VBW
              30 ≤ f ≤ 1 000                        Quasi Peak                           120 kHz                300 kHz
                                                      Peak                                1 MHz                  3 MHz
                    f ≥1000
                                                      Average                             1 MHz                             3 MHz
        Measured frequency range
           Highest frequency generated or used in the
         device or on which the device operates or tunes                        Upper frequency of measurement range (MHz)
                              (MHz)
                          Below 1.705                                                                        30.
                            1.705-108                                                                       1000.
                             108-500                                                                        2000.
                                    500-1000                                                          5000.
                                                                                5th harmonic of the highest frequency or 40 GHz,
                                   Above 1000
                                                                                              whichever is lower.
        Limits:
        Limits for Class B devices

                                                                                        limits at 3m (dBμV/m)
                      Frequency (MHz)
                                                                  QP Detector                PK Detector                   AV Detector
                              30-88                                    40.0                           --                           --
                             88-216                                    43.5                           --                           --
                           216-960                                     46.0                          --                           --
                          960 to 1000                                  54.0                          --                           --
                          Above 1000                                    --                          74.0                         54.0

        Remark:
        1. The lower limit shall apply at the transition frequencies.
        2. Emission level (dBμV/m) = 20 log Emission level (μV/m).
        3. For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
        peak field strength of any emission shall not exceed the maximum permitted average limits, specified above
        by more than 20 dB under any condition of modulation.
        Test Setup:            Refer to section 4.3.1 for details.

Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 14 of 21                           Report No.: 190518039EMC-1

        Test Procedures:
        1. From 30 MHz to 1GHz test procedure as below:
        1) The Product was placed on the non-conductive turntable 0.8 m above the ground at a chamber.
        2) Set the spectrum analyzer/receiver in Peak detector, Max Hold mode, and 120 kHz RBW. Record the
            maximum field strength of all the pre-scan process in the full band when the antenna is varied between
            1~4 m in both horizontal and vertical, and the turntable is rotated from 0 to 360 degrees.
        3) For each frequency whose maximum record was higher or close to limit, measure its QP value: vary the
            antenna’s height and rotate the turntable from 0 to 360 degrees to find the height and degree where
            Product radiated the maximum emission, then set the test frequency analyzer/receiver to QP Detector
            and specified bandwidth with Maximum Hold Mode, and record the maximum value.
        2. Above 1GHz test procedure as below:
        1) The Product was placed on the non-conductive turntable 0.8 m above the ground at a chamber.
        2) Set the spectrum analyzer/receiver in Peak detector, Max Hold mode, and 1MHz RBW. Record the
            maximum field strength of all the pre-scan process in the full band when the antenna is varied in both
            horizontal and vertical, and the turntable is rotated from 0 to 360 degrees.
        3) For each frequency whose maximum record was higher or close to limit, measure its AV value: rotate the
            turntable from 0 to 360 degrees to find the degree where Product radiated the maximum emission, then
            set the test frequency analyzer/receiver to AV value and specified bandwidth with Maximum Hold Mode,
            and record the maximum value.
        Equipment Used:        Refer to section 3 for details.
        Test Result:           Pass
        The worst measurement data as follows:
        Below 1GHz (Quasi Peak):
        Test Mode 3
        Horizontal




                                                             Correction
                         Frequency           Reading                             Result            Limit            Margin
             No.                                               factor                                                                Detector
                           (MHz)             (dBuV)                            (dBuV/m)          (dBuV/m)            (dB)
                                                              (dB/m )
              1             47.703             34.03           -13.08             20.95             40.00            -19.05                 QP
              2             78.564             42.89           -13.37             29.52             40.00            -10.48                 QP
              3             200.043            34.84           -10.25             24.59             43.50            -18.91                 QP
              4             214.606            35.08           -10.19             24.89             43.50            -18.61                 QP
              5             290.317            30.40             -7.16            23.24             46.00            -22.76                 QP
              6             804.252            26.66              1.49            28.15             46.00            -17.85                 QP

Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 15 of 21                           Report No.: 190518039EMC-1

        Vertical




                                                             Correction
                          Frequency          Reading                              Result           Limit             Margin
             No.                                               factor                                                                Detector
                            (MHz)            (dBuV)                             (dBuV/m)         (dBuV/m)             (dB)
                                                              (dB/m )
              1              35.016            34.00            -7.78             26.22             40.00            -13.78                 QP
              2              40.017            39.37           -10.36             29.01             40.00            -10.99                 QP
              3              58.485            36.17           -14.20             21.97             40.00            -18.03                 QP
              4             78.564             49.97            -13.37            36.60             40.00             -3.40                 QP
              5             194.499            35.97            -10.09            25.88             43.50            -17.62                 QP
              6             214.606            32.05            -10.19            21.86             43.50            -21.64                 QP




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 16 of 21                           Report No.: 190518039EMC-1

        Below 1GHz (Quasi Peak):
        Test Mode 5
        Horizontal




                                                             Correction
                         Frequency           Reading                             Result            Limit            Margin
             No.                                               factor                                                                Detector
                           (MHz)             (dBuV)                            (dBuV/m)          (dBuV/m)            (dB)
                                                              (dB/m )
              1            3969.238            47.39            2.45              49.84             74.00            -24.16                 QP
              2            6723.951            44.05            6.96              51.01             74.00            -22.99                 QP
              3           7682.150             44.32              7.33            51.65             74.00            -22.35                 QP
              4           10874.700            41.80             10.79            52.59             74.00            -21.41                 QP
              5           12642.190            39.90             11.46            51.36             74.00            -22.64                 QP
              6           16124.140            40.08             12.20            52.28             74.00            -21.72                 QP




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 17 of 21                           Report No.: 190518039EMC-1


        Vertical




                                                             Correction
                         Frequency           Reading                             Result            Limit            Margin
             No.                                               factor                                                                Detector
                           (MHz)             (dBuV)                            (dBuV/m)          (dBuV/m)            (dB)
                                                              (dB/m )
              1           2526.342             51.20            -0.32             50.88             74.00            -23.12                 QP
              2           3992.296             46.77             4.08             50.85             74.00            -23.15                 QP
              3           5586.324             44.89             5.09             49.98             74.00            -24.02                 QP
              4           6382.405             43.28             7.47             50.75             74.00            -23.25                 QP
              5           10442.590            42.55             9.43             51.98             74.00            -22.02                 QP
              6           16597.950            40.10             13.27            53.37             74.00            -20.63                 QP

       Remark:
       1. Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain, the value was added to Original Receiver
          Reading by the software automatically.
       2. Result = Reading + Correct Factor.
       3. Margin = Result – Limit
       4. All possible modes of operation were investigated, and testing at two nominal voltages of 240V/50Hz and
          120V/60Hz, only the worst case emissions reported.
       5. For Radiated Emission above 18GHz, there was not any unwanted emission detected.
       6. As shown in this section, for frequencies above 1GHz, the field strength limits are based on average limits.
          However, the peak field strength of any emission shall not exceed the maximum permitted average limits
          specified above by more than 20 dB under any condition of modulation. So, only the peak measurements
          were shown in the report.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 18 of 21                           Report No.: 190518039EMC-1

      6.2 CONDUCTED EMISSION
                                    FCC 47 CFR Part 15.107
        Test Requirement:
                                    ICES-003 Issue 6 Section 6.2
        Test Method:                ANSI C63.4-2014
        Limits:
        Limits for Class B devices
                   Frequency range                                                        Limits (dB(μV)
                        (MHz)                                        Quasi-peak                                      Average
                       0,15 to 0,50                                     66 to 56                                      56 to 46
                         0,50 to 5                                         56                                            46
                          5 to 30                                          60                                            50
        Remark:
        1. The lower limit shall apply at the transition frequencies.
        2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.50 MHz.
        Test Setup:           Refer to section 4.3.2 for details.
        Test Procedures:
        1) The Product was placed on a nonconductive table 0.8 m above the horizontal ground reference plane,
            and 0.4 m from the vertical ground reference plane, and connected to the main through Line Impedance
            Stability Network (L.I.S.N).
        2) The RBW of the receiver was set at 9 kHz in 150 kHz ~ 30MHz with Peak and AVG detector in Max Hold
            mode. Run the receiver’s pre-scan to record the maximum disturbance generated from Product in all
            power lines in the full band.
        3) For each frequency whose maximum record was higher or close to limit, measure its QP and AVG values
            and record.
        Equipment Used:       Refer to section 3 for details.
        Test Result:          Pass




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 19 of 21                           Report No.: 190518039EMC-1

       The measurement data as follows:
       Quasi Peak and Average:
       Test Mode 5
       Live Line




                                                          Correction
                    Frequency           Reading                                Result                                 Margin
         No.                                                factor                             Limit (dBuV)                             Detector
                      (MHz)             (dBuV)                                 (dBuV)                                  (dB)
                                                             (dB)
           1           0.174              29.90              10.02              39.92               54.77             -14.85            Average
           2           0.174              43.10              10.02              53.12               64.77             -11.65              QP
           3           0.210              20.70              10.01              30.71               53.21             -22.50            Average
           4           0.210              39.60              10.01              49.61               63.21             -13.60              QP
           5           1.438              19.39              10.16              29.55               46.00             -16.45            Average
           6           1.438              28.29              10.16              38.45               56.00             -17.55                QP




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 20 of 21                           Report No.: 190518039EMC-1

       Neutral Line




                                                          Correction
                    Frequency           Reading                                Result                                 Margin
         No.                                                factor                             Limit (dBuV)                             Detector
                      (MHz)             (dBuV)                                 (dBuV)                                  (dB)
                                                             (dB)
           1           0.190              32.70               9.99              42.69               54.04             -11.35            Average
           2           0.190              45.50               9.99              55.49               64.04              -8.55              QP
           3           0.238              28.50               9.98              38.48               52.17             -13.69            Average
           4           0.238              41.20               9.98              51.18               62.17             -10.99              QP
           5           0.298              23.60               9.96              33.56               50.30             -16.74            Average
           6           0.298              35.60               9.96              45.56               60.30             -14.74                QP

       Remark:
       1. Correct Factor = LISN Factor + Cable Loss + Pulse Limiter Factor, the value was added to Original
          Receiver Reading by the software automatically.
       2. Result = Reading + Correct Factor.
       3. Margin = Result - Limit
       4. An initial pre-scan was performed on the Phase and neutral lines with peak detector. Quasi-Peak and
          Average measurement were performed at the frequencies with maximized peak emission were detected.
       5. All possible modes of operation were investigated, and testing at two nominal voltages of 240V/50Hz and
          120V/60Hz, only the worst case emissions reported.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com


                                                               Page 21 of 21                           Report No.: 190518039EMC-1


APPENDIX 1 PHOTOS OF TEST SETUP
          See test photos attached in Appendix 1 for the actual connections between Product and support equipment.



APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS


                                          Refer to Appendix 2 for EUT external and internal photos.




                                             ********************* End of Report *********************

       The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer
       only to the sample(s) tested. Without written approval of UnionTrust, this report can’t be reproduced except in
       full.




Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: 16/F, Block A, Building 6, Baoneng Science and Technology Park, Qingxiang Road No.1, Longhua New District, Shenzhen, China
Tel: +86-755-28230888                  Fax: +86-755-28230886                  E-mail: info@uttlab.com               Http://www.uttlab.com



Document Created: 2019-09-27 07:36:37
Document Modified: 2019-09-27 07:36:37

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC