test report

FCC ID: XAM300011GR05

Test Report

Download: PDF
FCCID_2043663

FCC Measurement/Technical Report on
RFID transceiver – part of

Intrinsically Safe PDA i.roc®

Ci70

Report Reference: MDE_ECOM_1202_FCCb




Test Laboratory:
Borsigstr. 11
Germany
7Layers AG
40880 Ratingen

Note:
The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
without the written approval of the test laboratory.

7 layers AG                                        Aufsichtsratsvorsitzender                    Registergericht registered in:
Borsigstrasse 11                                   Chairman of the Supervisory Board:            Düsseldorf, HRB 44096
40880 Ratingen, Germany                            Ralf Mertens                                  USt-IdNr  VAT No.:
Phone: +49 (0) 2102 749 0                          Vorstand Board:                              DE 203159652
Fax: +49 (0) 2102 749 350                          Dr. H.-J. Meckelburg                          TAX No. 147/5869/0385
www.7Layers.com


Table of Contents
0 Summary                                             3
  0.1     Technical Report Summary                    3
  0.2     Measurement Summary                         4

1 Administrative Data                                 5
  1.1     Testing Laboratory                          5
  1.2     Project Data                                5
  1.3     Applicant Data                              5
  1.4     Manufacturer Data                           5

2 Test object Data                                    6
  2.1     General EUT Description                     6
  2.2     EUT Main components                         7
  2.3     Ancillary Equipment                         7
  2.4     Auxiliary Equipment                         7
  2.5     EUT Setups                                  8
  2.6     Operating Modes                             8

3 Test Results                                        9
  3.1     Spurious radiated emissions                 9
  3.2     Peak power output                          14
  3.3     Conducted emissions (AC power line)        15

4 Test Equipment                                     17
5 Photo Report                                       24
6 Setup Drawings                                     24
7 Annex measurement plots                            25
  7.1     Radiated emissions and peak output power   25
  7.2     AC Mains conducted                         31




Test report reference: MDE_ECOM_1202_FCCb             Page 2 of 32


0       Summary
0.1 Technical Report Summary

Type of Authorization
Certification for an intentional radiator: 125, 128 and 134 kHz RFID transceiver

Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in
47 CFR Ch.1 Parts 2 (10-1-11 Edition) and 15 (10-1-11 Edition). The following subparts
are applicable to the results in this test report.

Part 2, Subpart J - Equipment Authorization Procedures, Certification


Part 15, Subpart C – Intentional Radiators

§ 15.205    Restricted bands of operation

§ 15.207    Conducted limits

§ 15.209    Radiated emission limits; general requirements

§ 15.215    Additional provisions to the general radiated emission limitations




Note:
None




Summary Test Results:

The EUT complied with all performed tests as listed in chapter 0.2 Measurement
Summary.




Test report reference: MDE_ECOM_1202_FCCb                                          Page 3 of 32


0.2 Measurement Summary

FCC Part 15, Subpart C                §15.209
Radiated Emissions
The measurement was performed according to ANSI C63.4                                      2009
OP-Mode            Setup              Port                                                 Final Result
op-mode 1          Setup_01           Enclosure                                            passed

FCC Part 15, Subpart C                § 15.209
Peak Output Power
The measurement was performed according to ANSI C63.4                                      2009
OP-Mode           Setup               Port                                                 Final Result
op-mode 1         Setup_01            Enclosure                                            passed

FCC Part 15, Subpart C                § 15.207
Conducted Emissions AC Power line
The measurement was performed according to ANSI C63.4                                      2009
OP-Mode            Setup              Port                                                 Final Result
op-mode 1          Setup_01           AC-Mains                                             passed




                                                                                                 Digitally signed by Marco Kullik
                                 Digitally signed by Andreas Petz                                DN: cn=Marco Kullik, sn=Kullik,
                                 DN: cn=Andreas Petz, sn=Petz,                                   givenName=Marco, o=7 Layers AG,
                                 givenName=Andreas, o=7Layers AG,                                serialNumber=00100000000120290500

Responsible for                                                         Responsible
                                 serialNumber=00100000000120291800                               02, email=Marco.Kullik@7Layers.de
                                 01, email=andreas.petz@7layers.de                               Reason: I am the author of this
                                 Reason: I am approving this document
Accreditation Scope:                                                    for Test Report:
                                                                                                 document
                                 Date: 2013.04.04 13:05:57 +02'00'                               Date: 2013.04.04 12:18:11 +02'00'




Test report reference: MDE_ECOM_1202_FCCb                                                                            Page 4 of 32


1     Administrative Data
1.1 Testing Laboratory

Company Name:                               7Layers AG

Address                                     Borsigstr. 11
                                            40880 Ratingen
                                            Germany

This facility has been fully described in a report submitted to the FCC and accepted
under the registration number 96716.

The test facility is also accredited by the following accreditation organisation:
Laboratory accreditation no.:                DAkkS D-PL-12140-01-01

Responsible for Accreditation Scope:        Dipl.-Ing. Bernhard Retka
                                            Dipl.-Ing. Robert Machulec
                                            Dipl.-Ing. Andreas Petz
                                            Dipl. Ing. Marco Kullik

Report Template Version:                    2012-03-14

1.2 Project Data

Responsible for testing and report:         Dipl. Ing. Marco Kullik

Date of Test(s):                            2012-11-13 to 2013-03-01
Date of Report:                             2013-03-28

1.3 Applicant Data

Company Name:                               ECOM Instruments GmbH

Address:                                    Industriestraße 2
                                            97959 Assamstadt
                                            Germany

Contact Person:                             Mr. H. Fiederlein

1.4 Manufacturer Data
Company Name:                               please see applicant data

Address:


Contact Person:




Test report reference: MDE_ECOM_1202_FCCb                                           Page 5 of 32


2     Test object Data
2.1 General EUT Description

Equipment under Test                   Intrinsically Safe PDA i.roc®
Type Designation:                      Ci70
Kind of Device:                        125 / 128 / 134 kHz RFID Transceiver
(optional)
Voltage Type:                          DC (internal battery, Li-Ion)
Voltage level:                         3.7 V


General product description:

The EUT is a RFID transmitter, part of the Intrinsically Safe i.roc® Ci70 –Ex. It is a
handheld PDA, which contains the wireless technologies WLAN 2.4 GHz with b, g and n
modes, WLAN 5 GHz with a and n modes and Bluetooth. The EUT can be equipped with
different RFID modules. For the tests according to this standard, a 125/134 kHz and a
128 kHz module was used.
The EUT cannot be charged directly via an AC/DC adapter, this is only possible via an
additional docking station.


The EUT provides the following ports:

Ports
Enclosure
AC Mains Port (AE 1)


The main components of the EUT are listed and described in Chapter 2.2.




Test report reference: MDE_ECOM_1202_FCCb                                     Page 6 of 32


2.2 EUT Main components

Type, S/N, Short Descriptions etc. used in this Test Report

   Short       Equipment under            Type           Serial No.       HW              SW        Date of
Description            Test            Designation                      Status          Status      Receipt
EUT A         Intrinsically Safe PDA      Ci70        22321245059      P5.2          1.50.19.0013      –
(Code:        (numeric) inkl.
4E000b01)     TLB30-125/134 kHz
EUT B         Intrinsically Safe PDA      Ci70        22321245060      P5.2          1.50.19.0013      –
(Code:        (alphanumeric) inkl.
4E000e01)     LID-128 kHz



NOTE: The short description is used to simplify the identification of the EUT in this test
report.


2.3 Ancillary Equipment

For the purposes of this test report, ancillary equipment is defined as equipment which is
used in conjunction with the EUT to provide operational and control features to the EUT.
It is necessary to configure the system in a typical fashion, as a customer would normally
use it. But nevertheless Ancillary Equipment can influence the test results.

Short Description       Equipment            Type            Serial No.        HW          SW       FCC ID
                        under Test        Designation                         Status      Status
       AE 1                                                                                 –          –
                      AC/DC adapter        9004AE01         34351101811        01
 Code: 4E000ACD
   AE 2 Code:              Dual                                                             –          –
                                           1002UU02        222D1100216         01
  4E000DSDnew              Dock
       AE 3           LF Tag 125 kHz           –                0017             –          –          –
       AE 4           LF Tag 134 kHz           –                  –              –          –          –
       AE 5           LF Tag 128 kHz      Trovan ID200            –              –          –          –



2.4 Auxiliary Equipment

For the purposes of this test report, auxiliary equipment is defined as equipment which is
used temporarily to enable operational and control features especially used for the tests
of the EUT which is not used during normal operation or equipment that is used during
the tests in combination with the EUT but is not subject of this test report. It is necessary
to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

Short Description       Equipment            Type            Serial No.        HW          SW       FCC ID
                        under Test        Designation                         Status      Status
        –                   –                  –                 –              –           –          –




Test report reference: MDE_ECOM_1202_FCCb                                                       Page 7 of 32


2.5 EUT Setups

This chapter describes the combination of EUTs and ancillary equipment used for testing.

Setup No.      Combination of EUTs                            Description
Setup_01            EUT A + AE 3             setup for radiated emissions in 125 kHz range
Setup_02            EUT A + AE 4             setup for radiated emissions in 134 kHz range
Setup_03            EUT B + AE 5             setup for radiated emissions in 128 kHz range
Setup_04     EUT A + AE 1 + AE 2 + AE 3      setup for Conducted emissions (AC power line)
                                                    measurements in 125 kHz range
 Setup_05    EUT A + AE 1 + AE 2 + AE 4      setup for Conducted emissions (AC power line)
                                                    measurements in 134 kHz range
 Setup_06    EUT B + AE 1 + AE 2 + AE 5      setup for Conducted emissions (AC power line)
                                                    measurements in 128 kHz range



2.6 Operating Modes

This chapter describes the operating modes of the EUTs used for testing.

Op. Mode    Description of Operating Modes   Remarks
op-mode 1   unmodulated carrier signal       EUT is transmitting a periodic unmodulated signal
                                             and is continuously reading TAG information at 125
                                             kHz (TLB-30).
op-mode 2   unmodulated carrier signal       EUT is transmitting a periodic unmodulated signal
                                             and is continuously reading TAG information at 134
                                             kHz (TLB-30).
op-mode 3   unmodulated carrier signal       EUT is transmitting a periodic unmodulated signal
                                             and is continuously reading TAG information at 128
                                             kHz (LID).




Test report reference: MDE_ECOM_1202_FCCb                                                 Page 8 of 32


3     Test Results

3.1 Spurious radiated emissions

Standard       FCC Part 15, Subpart C

The test was performed according to: ANSI C63.4


3.1.1 Test Description

The test set-up was made in accordance to the general provisions of ANSI C63.4 in a
typical installation configuration. The Equipment Under Test (EUT) was set up on a non-
conductive table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT
support table that is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software ES-K1 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case
orientation of a body-worn or handheld EUT. The final test on all kind of EUTs is
performed at 2 axes. A pre-check is also performed while the EUT is powered from both
AC and DC (battery) power in order to find the worst-case operating condition.

1. Measurement up to 30 MHz
The Loop antenna HFH2-Z2 is used.
Step 1: pre-measurement
- Anechoic chamber
- Antenna distance: 10 m
- Detector: Peak-Maxhold
- Frequency range: 0.009 – 0.15 and 0.15 – 30 MHz
- Frequency steps: 0.1 kHz and 5 kHz
- IF–Bandwidth: 0.2 kHz and 10 kHz
- Measuring time / Frequency step: 100 ms
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: final measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is to find the maximum
emission level.
- Open area test side
- Antenna distance: according to the Standard
- Detector: Quasi-Peak
- Frequency range: 0.009 – 30 MHz
- Frequency steps: measurement at frequencies detected in step 1
- IF–Bandwidth: 200 Hz – 10 kHz
- Measuring time / Frequency step: 100 ms




Test report reference: MDE_ECOM_1202_FCCb                                        Page 9 of 32


2. Measurement above 30 MHz and up to 1 GHz
Step 1: Preliminary scan
Preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold
- Frequency range: 30 – 1000 MHz
- Frequency steps: 60 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 µs
- Turntable angle range: –180° to 180°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: second measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is, to find out the approximate
turntable angle and antenna height for each frequency.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: –180° to 180°
- Turntable step size: 45°
- Height variation range: 1 – 4 m
- Height variation step size: 0.5 m
- Polarisation: horizontal + vertical
After this step the EMI test system has determined the following values for each
frequency (of step 1):
- Frequency
- Azimuth value (of turntable)
- Antenna height
The last two values have now the following accuracy:
- Azimuth value (of turntable): 45°
- Antenna height: 0.5 m
Step 3: final measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved.
This is necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will
be adjusted. The turntable azimuth will be slowly varied by +/– 22.5° around this value.
During this action the value of emission is continuously measured. The turntable azimuth
at the highest emission will be recorded and adjusted. In this position the antenna height
is also slowly varied by +/– 25 cm around the antenna height determined. During this
action the value of emission is also continuously measured. The antenna height of the
highest emission will also be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: –22.5° to +22.5° around the determined value
- Height variation range: –0.25 m to +0.25 m around the determined value




Test report reference: MDE_ECOM_1202_FCCb                                        Page 10 of 32


Step 4: final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak(< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results
of the preliminary scan and a chart with the frequencies and values of the results of the
final measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
The Equipment Under Test (EUT) was set up on a non-conductive support at 1.4 m
height in the fully-anechoic chamber. The measurement distance was reduced to 1 m.
The results were extrapolated by the extrapolation factor of 20 dB/decade (inverse linear
distance for field strength measurements, inverse linear-distance squared for the power
reference level measurements). Due to the fact that in this frequency range a double
ridged wave guided horn antenna (up to 18 GHz) and a horn antenna (18-25 GHz) are
used, the steps 2-4 are omitted. Step 1 was performed with one height of the receiving
antenna only.
EMI receiver settings:
- Detector: Peak, Average
- IF Bandwidth = 1 MHz


3.1.2 Test Requirements / Limits
FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

Frequency in MHz        Limit (µV/m)        Measurement distance (m)   Limit(dBµV/m @10m)
0.009 – 0.49            2400/F(kHz)         300                        Limit (dBµV/m)+59.1dB
0.49 – 1.705            24000/F(kHz)        30                         Limit (dBµV/m)+19.1dB
1.705 – 30              30                  30                         Limit (dBµV/m)+19.1dB

Frequency in MHz         Limit (µV/m)       Measurement distance (m)   Limit (dBµV/m)
30 – 88                  100                3                          40.0
88 – 216                 150                3                          43.5
216 – 960                200                3                          46.0
above 960                500                3                          54.0


§15.35(b)
..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above
the maximum permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)




Test report reference: MDE_ECOM_1202_FCCb                                         Page 11 of 32


3.1.3 Test Protocol

Temperature:          22 °C
Air Pressure:         1009 – 1015 hPa
Humidity:             32 – 33 %


3.1.3.1 Measurement up to 30 MHz

Op. Mode              Setup                        Port
op-mode 1             Setup_01                     Enclosure

  Polari-    Frequency           Corrected value        Limit    Limit    Limit    Delta to    Delta to
  sation        MHz                 dBµV/m             dBµV/    dBµV/    dBµV/       limit      limit
                                                          m        m        m          dB         dB
                            QP        Peak     AV        QP      Peak      AV      QP/Peak       AV

    –             –          –         –           –     –        –        –          –           –

Remark: Please see annex for the measurement plots. No relevant spurious emissions found, therefore step 2
        was not performed.

Op. Mode              Setup                        Port
op-mode 2             Setup_02                     Enclosure

  Polari-    Frequency           Corrected value        Limit    Limit    Limit    Delta to    Delta to
  sation        MHz                 dBµV/m             dBµV/    dBµV/    dBµV/       limit      limit
                                                          m        m        m          dB         dB
                            QP        Peak     AV        QP      Peak      AV      QP/Peak       AV

    –             –          –         –           –     –        –        –          –           –

Remark: Please see annex for the measurement plots. No relevant spurious emissions found, therefore step 2
        was not performed.

Op. Mode              Setup                        Port
op-mode 3             Setup_03                     Enclosure

  Polari-    Frequency           Corrected value        Limit    Limit    Limit    Delta to    Delta to
  sation        MHz                 dBµV/m             dBµV/    dBµV/    dBµV/       limit      limit
                                                          m        m        m          dB         dB
                            QP        Peak     AV        QP      Peak      AV      QP/Peak       AV

    –             –          –         –           –     –        –        –          –           –

Remark: Please see annex for the measurement plots. No relevant spurious emissions found, therefore step 2
        was not performed.




Test report reference: MDE_ECOM_1202_FCCb                                                      Page 12 of 32


3.1.3.2 Measurement above 30 MHz

Op. Mode              Setup                        Port
op-mode 1             Setup_01                     Enclosure

  Polari-    Frequency           Corrected value           Limit    Limit      Limit   Delta to   Delta to
  sation        MHz                 dBµV/m                dBµV/    dBµV/      dBµV/      limit     limit
                                                             m        m          m         dB        dB
                            QP        Peak     AV           QP      Peak        AV     QP/Peak      AV

    –             –          –         –           –        –        –          –         –          –

Remark: No (further) spurious emissions in the range 20 dB below the limit found.



Op. Mode              Setup                        Port
op-mode 2             Setup_02                     Enclosure

  Polari-    Frequency           Corrected value           Limit    Limit      Limit   Delta to   Delta to
  sation        MHz                 dBµV/m                dBµV/    dBµV/      dBµV/      limit     limit
                                                             m        m          m         dB        dB
                            QP        Peak     AV           QP      Peak        AV     QP/Peak      AV

    –             –          –         –           –        –        –          –         –          –

Remark: No (further) spurious emissions in the range 20 dB below the limit found.



Op. Mode              Setup                        Port
op-mode 3             Setup_03                     Enclosure

  Polari-    Frequency           Corrected value           Limit    Limit      Limit   Delta to   Delta to
  sation        MHz                 dBµV/m                dBµV/    dBµV/      dBµV/      limit     limit
                                                             m        m          m         dB        dB
                            QP        Peak     AV           QP      Peak        AV     QP/Peak      AV

    –             –          –         –           –        –        –          –         –          –

Remark: No (further) spurious emissions in the range 20 dB below the limit found.




3.1.4 Test result: Spurious radiated emissions
                       FCC Part 15, Subpart C          Op. Mode             Result
                                                       op-mode 1            passed
                                                       op-mode 2            passed
                                                       op-mode 3            passed




Test report reference: MDE_ECOM_1202_FCCb                                                         Page 13 of 32


3.2 Peak power output

Standard        FCC Part 15, Subpart C

The test was performed according to: FCC §15.209, ANSI C63.4


3.2.1 Test Description
Please refer to sub-clause 3.1.1.


3.2.2 Test Limits
Please refer to sub-clause 3.1.2.


3.2.3 Test Protocol

Temperature:      22 °C
Air Pressure:     1015 hPa
Humidity:         33 %

Op. Mode          Setup                       Port
op-mode 1         Setup_01                    Enclosure

 Output power         Frequency          Limit dBµV/m at fundamental              Remarks
   dBµV/m                kHz              frequency for 10 m distance
     47.3               125.3                         84.8              Maximum radiated field strength
                                                                          at fundamental frequency



Op. Mode          Setup                       Port
op-mode 2         Setup_02                    Enclosure

 Output power         Frequency          Limit dBµV/m at fundamental              Remarks
   dBµV/m                kHz              frequency for 10 m distance
     47.6               133.7                         84.2              Maximum radiated field strength
                                                                          at fundamental frequency



Op. Mode          Setup                       Port
op-mode 3         Setup_03                    Enclosure

 Output power         Frequency          Limit dBµV/m at fundamental              Remarks
   dBµV/m                kHz              frequency for 10 m distance
     70.3               128.2                         84.6              Maximum radiated field strength
                                                                          at fundamental frequency




3.2.4 Test result: Peak power output
                FCC Part 15, Subpart C     Op. Mode               Result
                                           op-mode 1              passed
                                           op-mode 2              passed
                                           op-mode 3              passed




Test report reference: MDE_ECOM_1202_FCCb                                                Page 14 of 32


3.3   Conducted emissions (AC power line)

Standard       FCC Part 15, Subpart C

The test was performed according to: ANSI C63.4


3.3.1 Test Description
The test set-up was made in accordance to the general provisions of ANSI C63.4.
The Equipment Under Test (EUT) was setup in a shielded room to perform the conducted
emissions measurements in a typical installation configuration. The EUT was powered
from 50µH || 50 Ohm Line Impedance Stabilization Network (LISN). which meets the
requirements of ANSI C63.4, Annex B, in the frequency range of the measurements. The
LISN’s unused connections were terminated with 50 Ohm loads.

The measurement procedure consists of two steps. It is implemented into the EMI test
software ES-K1 from R&S.

Step 1: Preliminary scan
Intention of this step is, to determine the conducted EMI-profile of the EUT.
EMI receiver settings:
- Detector: Peak - Maxhold
- Frequency range: 150 kHz – 30 MHz
- Frequency steps: 5 kHz
- IF–Bandwidth: 9 kHz
- Measuring time / Frequency step: 20 ms
- Measurement on phase + neutral lines of the power cords
- AC Mains supplied at 120 V / 60 Hz.

On basis of this preliminary scan the highest amplitudes and the corresponding
frequencies relative to the limit are identified. Emissions above the limit and emissions
which are in the 10 dB range below the limit are considered.

Step 2: Final measurement
Intention of this step is, to determine the highest emissions with the settings defined in
the test specification for the frequencies identified in step 1.
EMI receiver settings:
- Detector: Quasi-Peak
- IF - Bandwidth: 9 kHz
- Measuring time: 1 s / frequency

At each frequency determined in step 1, four measurements are performed in the
following combinations:
1) Neutral lead - reference ground (PE grounded)
2) Phase lead - reference ground (PE grounded)
3) Neutral lead - reference ground (PE floating)
4) Phase lead - reference ground (PE floating)

The highest value is reported. The chosen operating mode is selected as representative
mode to generate “worst-case” conditions, i.e. high power consumption.




Test report reference: MDE_ECOM_1202_FCCb                                        Page 15 of 32


3.3.2 Test Requirements / Limits

FCC Part 15, Subpart C, §15.207

  Frequency Range (MHz)            QP Limit (dBµV)                    AV Limit (dBµV)
        0.15 – 0.5                    66 to 56                           56 to 46
          0.5 – 5                        56                                 46
          5 – 30                         60                                 50

Used conversion factor: Limit (dBµV) = 20 log (Limit (µV)/1µV).


3.3.3 Test Protocol

Temperature:       23 °C
Air Pressure:      1037 hPa
Humidity:          37 %

Op. Mode           Setup                      Port
op-mode 1          Setup_04                   AC-Port

  Power      Frequency      Measured value           Delta to limit                 Remarks
   line         MHz             dBµV                     dBµV
    L1         0.565             37.4                     8.6                      AV-detector



Op. Mode           Setup                      Port
op-mode 2          Setup_05                   AC-Port

  Power      Frequency      Measured value           Delta to limit                 Remarks
   line         MHz             dBµV                     dBµV
     –           –                –                        –                            –



Op. Mode           Setup                      Port
op-mode 3          Setup_06                   AC-Port

  Power      Frequency      Measured value           Delta to limit                 Remarks
   line         MHz             dBµV                     dBµV
     –           –                –                        –                            –

Remark: Please see annex for the measurement plot.




3.3.4 Test result: Conducted emissions (AC power line)
                     FCC Part 15, Subpart C    Op. Mode                   Result
                                               op-mode 1                  passed
                                               op-mode 2                  passed
                                               op-mode 3                  passed




Test report reference: MDE_ECOM_1202_FCCb                                                        Page 16 of 32


4      Test Equipment


    The calibration, hardware and software states are shown for the testing period.


    Test Equipment Anechoic Chamber
     Lab ID:                    Lab 3
     Manufacturer:              Frankonia
     Description:               Anechoic Chamber for radiated testing
     Type:                      10.58x6.38x6.00 m³

     Single Devices for Anechoic Chamber
       Single Device Name       Type                                     Serial Number   Manufacturer

       Air compressor           none                                     -               Atlas Copco

       Anechoic Chamber         10.58 x 6.38 x 6.00 m³                   none            Frankonia
                                FCC listing 96716 3m Part15/18                           2011/01/11       2014/01/10
                                IC listing 3699A-1 3m                                    2011/02/07       2014/02/06

       Controller Maturo        MCU                                      961208          Maturo GmbH

       EMC camera               CE-CAM/1                                 -               CE-SYS

       EMC camera Nr.2          CCD-400E                                 0005033         Mitsubishi

       Filter ISDN              B84312-C110-E1                                           Siemens&Matsushita

       Filter Universal 1A      BB4312-C30-H3                            -               Siemens&Matsushita


    Test Equipment Auxiliary Equipment for Conducted emissions
     Lab ID:                    Lab 1
     Manufacturer:              Rohde & Schwarz GmbH & Co.KG
     Description:               EMI Conducted Auxiliary Equipment

     Single Devices for Auxiliary Equipment for Conducted emissions
       Single Device Name       Type                                     Serial Number   Manufacturer

       AC Power Source          Chroma 6404                              64040001304     Chroma ATE INC.

       Cable "LISN to ESI"      RG214                                    W18.03+W48.03   Huber&Suhner
                                Path Calibration                                         2011/11/11   2012/11/10

       Two-Line V-Network       ESH 3-Z5                                 828304/029      Rohde & Schwarz GmbH & Co.
                                                                                         KG

       Two-Line V-Network       ESH 3-Z5                                 829996/002      Rohde & Schwarz GmbH & Co.
                                                                                         KG
                                DKD calibration                                          2011/01/20   2013/01/19




Test report reference: MDE_ECOM_1202_FCCb                                                             Page 17 of 32


   Test Equipment Auxiliary Equipment for Radiated emissions
    Lab ID:                 Lab 3
    Description:            Equipment for emission measurements
    Serial Number:          see single devices

    Single Devices for Auxiliary Equipment for Radiated emissions
      Single Device Name    Type                                  Serial Number    Manufacturer

      Antenna mast          AS 620 P                              620/37           HD GmbH

      Biconical dipole      VUBA 9117                             9117-108         Schwarzbeck
                            Calibration Details                                    Last Execution    Next Exec.
                            Standard Calibration                                   2008/10/27       2013/10/26
                            Standard Calibration                                   2012/01/18       2015/01/17

      Broadband Amplifier   JS4-18002600-32-5P                    849785           Miteq
      18MHz-26GHz
                            Path Calibration                                       2012/05/24       2012/11/23

      Broadband Amplifier   AFS4-01000400-1Q-10P-4                -                Miteq
      1GHz-4GHz
                            Path Calibration                                       2012/05/24       2012/11/23

      Broadband Amplifier   JS4-00101800-35-5P                    896037           Miteq
      30MHz-18GHz
                            Path Calibration                                       2012/05/24       2012/11/23

      Cable "ESI to EMI     EcoFlex10                             W18.01-2+W38.01- Kabel Kusch
      Antenna"                                                    2
                            Path Calibration                                       2012/05/24       2012/11/23

      Cable "ESI to Horn    UFB311A+UFB293C                       W18.02-2+W38.02- Rosenberger Micro-Coax
      Antenna"                                                    2
                            Path Calibration                                       2012/05/24    2012/11/23
                            Path Calibration                                       2012/05/24    2012/11/23

      Double-ridged horn    HF 906                                357357/001       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Standard Calibration                                   2012/05/18   2015/05/17

      Double-ridged horn    HF 906                                357357/002       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Standard Calibration                                   2012/06/26   2015/06/25

      High Pass Filter      4HC1600/12750-1.5-KK                  9942011          Trilithic
                            Path Calibration                                       2012/05/24       2012/11/23

      High Pass Filter      5HC2700/12750-1.5-KK                  9942012          Trilithic
                            Path Calibration                                       2012/05/24       2012/11/23

      High Pass Filter      5HC3500/12750-1.2-KK                  200035008        Trilithic
                            Path Calibration                                       2012/05/24       2012/11/23

      High Pass Filter      WHKX 7.0/18G-8SS                      09               Wainwright
                            Path Calibration                                       2012/05/24       2012/11/23

      Horn Antenna          BBHA 9170
      Schwarzbeck 15-26 GHz
      BBHA 9170

      Log.-per. Antenna     HL 562 Ultralog                       830547/003       Rohde & Schwarz GmbH & Co.
                                                                                   KG

      Loop Antenna          HFH2-Z2                               829324/006       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Standard calibration                                   2011/10/27   2014/10/26

      Pyramidal Horn Antenna 3160-09                              00083069         EMCO Elektronik GmbH
      26,5 GHz

      Pyramidal Horn Antenna 3160-10                              00086675         EMCO Elektronik GmbH
      40 GHz

Test report reference: MDE_ECOM_1202_FCCb                                                    Page 18 of 32


    Single Devices for Auxiliary Equipment for Radiated emissions (continued)
      Single Device Name       Type                                    Serial Number   Manufacturer

      Tilt device Maturo       Antrieb TD1.5-10kg                      TD1.5-           Maturo GmbH
      (Rohacell)                                                       10kg/024/3790709



   Test Equipment Auxiliary Test Equipment
    Lab ID:                    Lab 3, Lab 4
    Manufacturer:              see single devices
    Description:               Single Devices for various Test Equipment
    Type:                      various
    Serial Number:             none

    Single Devices for Auxiliary Test Equipment
      Single Device Name       Type                                    Serial Number   Manufacturer

      AC Power Source          Chroma 6404                             64040001304     Chroma ATE INC.

      Broadband Power Divider 1506A / 93459                            LM390           Weinschel Associates
      N (Aux)

      Broadband Power Divider WA1515                                   A855            Weinschel Associates
      SMA

      Digital Multimeter 03    Fluke 177                               86670383        Fluke Europe B.V.
      (Multimeter)
                               Customized calibration                                  2011/10/19     2013/10/18

      Fibre optic link Satellite FO RS232 Link                         181-018         Pontis
      (Aux)

      Fibre optic link         FO RS232 Link                           182-018         Pontis
      Transceiver (Aux)

      Isolating Transformer    LTS 604                                 1888            Thalheimer
                                                                                       Transformatorenwerke GmbH


      Notch Filter Ultra Stable WRCA800/960-6EEK                       24              Wainwright
      (Aux)

      Vector Signal Generator SMIQ 03B                                 832492/061      Rohde & Schwarz GmbH &
                                                                                       Co.KG




Test report reference: MDE_ECOM_1202_FCCb                                                       Page 19 of 32


   Test Equipment Digital Signalling Devices
    Lab ID:                    Lab 1, Lab 3, Lab 4
    Description:               Signalling equipment for various wireless technologies.

    Single Devices for Digital Signalling Devices
      Single Device Name       Type                                     Serial Number    Manufacturer

      Bluetooth Signalling Unit CBT                                     100589           Rohde & Schwarz GmbH & Co.
      CBT                                                                                KG
                                Standard calibration                                     2011/11/24   2014/11/23

      CMW500                   CMW500                                   107500           Rohde & Schwarz GmbH &
                                                                                         Co.KG
                               Calibration Details                                       Last Execution Next Exec.
                               Initial factory calibration                               2012/01/26     2014/01/25

      Universal Radio          CMU 200                                  102366           Rohde & Schwarz GmbH & Co.
      Communication Tester                                                               KG
                               Standard calibration                                      2011/05/26    2013/05/25
                               HW/SW Status                                              Date of Start  Date of End
                               Hardware:                                                 2007/07/16
                               B11, B21V14, B21-2, B41, B52V14, B52-2,
                               B53-2, B56V14, B68 3v04, PCMCIA, U65V04
                               Software:
                               K21 4v21, K22 4v21, K23 4v21, K24 4v21, K42     4v21,
                               K43 4v21, K53 4v21, K56 4v22, K57 4v22, K58     4v22,
                               K59 4v22, K61 4v22, K62 4v22, K63 4v22, K64     4v22,
                               K65 4v22, K66 4v22, K67 4v22, K68 4v22, K69     4v22
                               Firmware:
                               µP1 8v50 02.05.06
                               ---

      Universal Radio          CMU 200                                  837983/052       Rohde & Schwarz GmbH & Co.
      Communication Tester                                                               KG
                               Standard calibration                                      2011/12/07    2014/12/06
                               HW/SW Status                                              Date of Start  Date of End
                               HW options:                                               2007/01/02
                               B11, B21V14, B21-2, B41, B52V14, B52-2,    B53-2,
                               B54V14, B56V14, B68 3v04, B95, PCMCIA,     U65V02
                               SW options:
                               K21 4v11, K22 4v11, K23 4v11, K24 4v11,    K27 4v10,
                               K28 4v10, K42 4v11, K43 4v11, K53 4v10,    K65 4v10,
                               K66 4v10, K68 4v10,
                               Firmware:
                               µP1 8v40 01.12.05
                               ---
                               SW:                                                       2008/11/03
                               K62, K69




Test report reference: MDE_ECOM_1202_FCCb                                                         Page 20 of 32


   Test Equipment Emission measurement devices
    Lab ID:                Lab 1, Lab 3
    Description:           Equipment for emission measurements
    Serial Number:         see single devices

    Single Devices for Emission measurement devices
      Single Device Name   Type                                   Serial Number   Manufacturer

      Personal Computer    Dell                                   30304832059     Dell

      Power Meter          NRVD                                   828110/016      Rohde & Schwarz GmbH &
                                                                                  Co.KG
                           Calibration Details                                    Last Execution Next Exec.
                           Standard calibration                                   2012/05/22     2013/05/21

      Power Sensor         NRV-Z1                                 836219/005      Rohde & Schwarz GmbH & Co.
                                                                                  KG

      Powermeter           NRVS                                   836333/064      Rohde & Schwarz GmbH & Co.
                                                                                  KG

      Sensor Head A        NRV-Z1                                 827753/005      Rohde & Schwarz GmbH &
                                                                                  Co.KG
                           Calibration Details                                    Last Execution Next Exec.
                           Standard calibration                                   2012/05/21     2013/05/20

      Signal Generator     SMR 20                                 846834/008      Rohde & Schwarz GmbH & Co.
                                                                                  KG
                           Calibration Details                                    Last Execution Next Exec.
                           standard calibration                                   2011/05/12     2014/05/11

      Spectrum Analyzer    ESIB 26                                830482/004      Rohde & Schwarz GmbH & Co.
                                                                                  KG
                           Standard Calibration                                   2011/12/05    2013/12/04
                           HW/SW Status                                           Date of Start  Date of End
                           Firmware-Update 4.34.4 from 3.45 during calibration    2009/12/03




Test report reference: MDE_ECOM_1202_FCCb                                                  Page 21 of 32


   Test Equipment Radio Lab Test Equipment
    Lab ID:                  Lab 4
    Description:             Radio Lab Test Equipment

    Single Devices for Radio Lab Test Equipment
      Single Device Name     Type                       Serial Number    Manufacturer

      Broadband Power Divider WA1515                    A856             Weinschel Associates
      SMA

      Coax Attenuator 10dB   4T-10                      F9401            Weinschel Associates
      SMA 2W

      Coax Attenuator 10dB   56-10                      W3702            Weinschel Associates
      SMA 2W

      Coax Attenuator 10dB   56-10                      W3711            Weinschel Associates
      SMA 2W

      Coax Cable             Sucotest 2,0m                               Rosenberger Micro-Coax
      Huber&Suhner

      Coax Cable Rosenberger FA210A0010003030           54491-2          Rosenberger Micro-Coax
      Micro Coax
      FA210A0010003030
      SMA/SMA 1,0m


      Power Meter            NRVD                       828110/016       Rohde & Schwarz GmbH &
                                                                         Co.KG
                             Calibration Details                         Last Execution Next Exec.
                             Standard calibration                        2012/05/22       2013/05/21

      Power Sensor           NRV-Z1                     836219/005       Rohde & Schwarz GmbH & Co.
                                                                         KG

      Powermeter             NRVS                       836333/064       Rohde & Schwarz GmbH & Co.
                                                                         KG

      RF Step Attenuator RSP RSP                        833695/001       Rohde & Schwarz GmbH &
                                                                         Co.KG

      Rubidium Frequency     Datum, Model: MFL          2689/001         Datum-Beverly
      Standard
                             Standard calibration                        2012/06/21       2013/06/20

      Sensor Head A          NRV-Z1                     827753/005       Rohde & Schwarz GmbH &
                                                                         Co.KG
                             Calibration Details                         Last Execution Next Exec.
                             Standard calibration                        2012/05/21       2013/05/20

      Signal Generator       SMY02                      829309/018       Rohde & Schwarz GmbH & Co.
                                                                         KG
                             Standard calibration                        2011/11/04   2014/11/03

      Signal Generator SME   SME03                      827460/016       Rohde & Schwarz GmbH &
                                                                         Co.KG
                             Standard calibration                        2011/11/25   2014/11/24

      Signal Generator SMP   SMP02                      836402/008       Rohde & Schwarz GmbH & Co.
                                                                         KG

      Spectrum Analyser      FSIQ26                     840061/005       Rohde & Schwarz GmbH & Co.
                                                                         KG
                             Calibration Details                         Last Execution Next Exec.
                             Standard calibration                        2011/02/10       2013/02/09

      Temperature Chamber    VT 4002                    58566002150010   Vötsch
      Vötsch 03
                             Calibration Details                         Last Execution    Next Exec.
                             Customized calibration                      2012/03/12       2014/03/11


Test report reference: MDE_ECOM_1202_FCCb                                          Page 22 of 32


    Single Devices for Radio Lab Test Equipment (continued)
      Single Device Name    Type                                  Serial Number   Manufacturer

      Vector Signal Generator SMIQ 03B                            837747/020      Rohde & Schwarz GmbH & Co.
                                                                                  KG


   Test Equipment Shielded Room 02
    Lab ID:                 Lab 1
    Manufacturer:           Frankonia
    Description:            Shielded Room for conducted testing
    Type:                   12 qm
    Serial Number:          none




Test report reference: MDE_ECOM_1202_FCCb                                                  Page 23 of 32


5     Photo Report

Photos are included in an external report.




6     Setup Drawings




Drawing 1:     Setup in the Anechoic chamber. For measurements below 1 GHz the
               ground was replaced by a conducting ground plane.




Test report reference: MDE_ECOM_1202_FCCb                                 Page 24 of 32


7        Annex measurement plots
7.1 Radiated emissions and peak output power

7.1.1 Spurious radiated emissions up to 30 MHz – Op-Mode 1

Antenna position 90°
EUT position horizontal


 Marker:                125.3 kHz              47.3 dBµV/m         X

    Level [dBµV/m]
 110

 100



    80



    60



    40



    20

    10
         9k   20k    40k      100k       300k       1M   2M   4M       10M     30M
                                     Frequency [Hz]

         MES ECO_1202_079_pre PK
         LIM H-Field_FCC209_10m




Test report reference: MDE_ECOM_1202_FCCb                               Page 25 of 32


7.1.2 Spurious radiated emissions up to 30 MHz – Op-Mode 2

Antenna position 90°
EUT position horizontal


 Marker:                  133.7 kHz         47.61 dBµV/m        X

   Level [dBµV/m]
 110

 100



  80



  60



  40



  20



    0
        9k 20k 40k            100k   300k      1M   2M     4M       10M     30M
                                  Frequency [Hz]

      MES ECO_1202_083_pre PK
      LIM H-Field_FCC209_10m




Test report reference: MDE_ECOM_1202_FCCb                            Page 26 of 32


7.1.3 Spurious radiated emissions up to 30 MHz – Op-Mode 3

Antenna position 90°
EUT position horizontal


 Marker:                128.2 kHz              70.28 dBµV/m        X

   Level [dBµV/m]
 110

 100



  80



  60



  40



  20

  10
       9k    20k 40k          100k       300k       1M   2M   4M       10M     30M
                                     Frequency [Hz]

      MES ECO_1202_138_pre PK
      LIM H-Field_FCC209_10m




Test report reference: MDE_ECOM_1202_FCCb                               Page 27 of 32


7.1.4 Spurious radiated emissions above 30 MHz – Op_Mode 1




  Level [dBµV/m]
 80

 70

 60

 50

 40

 30

 20

 10

  0
      30M      50M     70M     100M         200M   300M   500M 700M 1G
                                 Frequency [Hz]

      MES ECO_1202_069_pre PK
      LIM FCC part 15 b Field Strength QP Limit




Test report reference: MDE_ECOM_1202_FCCb                         Page 28 of 32


7.1.5 Spurious radiated emissions above 30 MHz – Op-Mode 2

Note: Peak at 900 MHz is an external GSM interferer


  Level [dBµV/m]
 80

 70


 60


 50


 40


 30


 20


 10


  0
      30M      50M     70M     100M         200M      300M   500M 700M 1G
                                 Frequency [Hz]

      MES ECO_1202_070_pre PK
      LIM FCC part 15 b Field Strength QP Limit




Test report reference: MDE_ECOM_1202_FCCb                            Page 29 of 32


7.1.6 Spurious radiated emissions above 30 MHz – Op-Mode 3



 Marker:              115.8 MHz              17.41 dBµV/m

  Level [dBµV/m]
 60



 50



 40



 30



 20



 10



  0
      30M       50M      70M      100M              200M    300M   500M   700M     1G
                                     Frequency [Hz]

      MES ECO_1202_141_pre PK
      LIM FCC part 15 b Field Strength QP Limit




Test report reference: MDE_ECOM_1202_FCCb                                 Page 30 of 32


7.2      AC Mains conducted

7.2.1 RFID 125 kHz conducted emissions (AC power line)

Short Description:                                                   FCC Voltage 120 V 60 Hz
    Start          Stop          Step     Detector    Meas.       IF           Transducer
 Frequency      Frequency        Width                Time      Bandw.
 150.0 kHz       30.0 MHz       5.0 kHz   MaxPeak    20.0 ms   9 kHz          ESH3-Z5
                                          Average



    Level [dBµV]
 80


 70


 60


 50


 40
                            +

 30


 20


 10


    0
        150k 300k      500k           1M      2M 3M        5M 7M 10M                 30M
                                      Frequency [Hz]

+       MES ECO_1202_119_fin AV
        MES ECO_1202_119_pre PK
        MES ECO_1202_119_pre AV
        LIM FCC 15b QP volt  Voltage QP Limit
        LIM FCC 15b AV volt Voltage QP Limit




Test report reference: MDE_ECOM_1202_FCCb                                           Page 31 of 32


7.2.2 RFID 134 kHz conducted emissions (AC power line)

Short Description:                                                    FCC Voltage 120 V 60 Hz
    Start          Stop          Step     Detector    Meas.        IF           Transducer
 Frequency      Frequency       Width                 Time       Bandw.
 150.0 kHz       30.0 MHz       5.0 kHz   MaxPeak    20.0 ms    9 kHz          ESH3-Z5
                                          Average



    Level [dBµV]
 80


 70


 60


 50


 40


 30


 20


 10                         +


    0
        150k 300k      500k           1M      2M 3M            5M 7M 10M                  30M
                                      Frequency [Hz]

+       MES ECO_1202_120_fin AV
        MES ECO_1202_120_pre PK
        MES ECO_1202_120_pre AV
        LIM FCC 15b QP volt  Voltage QP Limit
        LIM FCC 15b AV volt Voltage QP Limit




Test report reference: MDE_ECOM_1202_FCCb                                                Page 32 of 32



Document Created: 2013-04-04 13:05:57
Document Modified: 2013-04-04 13:05:57

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC