21




                                               MPE CALCULATION

APPLICANT:                                                   Power-One Italy S.p.a.
                                                             Via San Giorgio, 642 – 52028 Terranuova Bracciolini (AR)
                                                             Italy
                                                             Tel. +39 055 91951
                                                             E-mail: gianfranco.iannuzzi@power-one.com
                                                                               paolo.mugnai@power-one.com
EUT DESCRIPTION                                              Radio Equipment ZigBee module for inverter check
EUT TRADEMARK                                                Power-One

EUT MODEL                                                    PVI-RADIOMODULE-Z

REFERENCE STANDARDS :                                        47 CFR FCC _ RF EXPOSURE REQUIRMENTS [§§
                                                             15.247(e)(i), 1.1310 & 2.1091]


DATE OF ISSUE                                                05/10/2011


LABORATORY                                                   Prima Ricerca & Sviluppo S.r.l.
                                                             Via Campagna, 92 -22020 Faloppio (Co) –Italy

ISSUED BY                                                    Massimo Maltempi



APPROVED BY                                                  Giovanni Molteni



The calculation results reported in this document shall refer only to Test Report above indicated and relevant tested sample




                                                                                                                             Page 1 of 2
                                                 Prima Ricerca & Sviluppo S.r.l. – Capitale Sociale € 50.000 i.v.
                                     Codice Fiscale e Partita IVA 02635860139 – Uff. registro di COMO - n.REA CO270979
                                  Sede : I-22020 Faloppio (Co) – Via Campagna, 92 – Tel +39 031.3500011 Fax +39 031.991309
                                                           www.primaricerca.it; info@primaricerca.it


22




Test Report reference

      FCCTR_111161_0 issued 29/09/2011 by Prima Ricerca & Sviluppo



Worst case condition: Channel 24
Calculation Results


                                             Conducted Antenna                                                       Radiated
                                                Connector
  Power at the Antenna                                    0 .7 4 W
     Antenna Gain in dB                                 -2,14 dBi
 Distance to the Area of                            0.656 feet
         Interst                                  0.1999 metres
 Frequency of Operation                               2470 MHz
 Are Ground reflections                                      Yes
      Calculated
     Estimated RF Power                          0.0618 mW /cm2
           Density




                                     Controlled                     Uncontrolled                   Controlled            Uncontrolled
                                    Environment                     Environment                   Environment            Environment
 Maximum Permissible                    5.005
                                                                  1.005 mW /cm2
   Exposure (MPE)                     mW/cm2
Distance to Compliance               0.1229 feet
                                                                    0.213 feet
From Centre of Antenna                 0.0375
                                                                  0.0649 metres
                                       metres
Does the Area of Interest
    Appear to be in                          yes                             yes
      Compliance




                                                                                                                            Page 2 of 2
                                         Prima Ricerca & Sviluppo S.r.l. – Capitale Sociale € 50.000 i.v.
                             Codice Fiscale e Partita IVA 02635860139 – Uff. registro di COMO - n.REA CO270979