FCC Part 15.407 Test Report

FCC ID: X4GS00947

Test Report

Download: PDF
FCCID_2986533

                                                   Test Report
                                       Prepared for: Taser International, Inc.

                                                    Model: T00064

                                          Description: Body Worn Camera

                                             Serial Number: X81002508

                                                 FCC ID: X4GS00947

                                                          To

                                                   FCC Part 15.407

                                             Date of Issue: April 28, 2016



On the behalf of the applicant:           Taser International, Inc.
                                          17800 N. 85th St.
                                          Scottsdale, AZ 85260

Attention of:                             Bryan Chiles
                                          Ph: (480)502-6260
                                          E-mail: bchiles@taser.com


                                                   Prepared By
                                             Compliance Testing, LLC
                                                1724 S. Nevada Way
                                                  Mesa, AZ 85204
                                     (480) 926-3100 phone / (480) 926-3598 fax
                                            www.compliancetesting.com
                                               Project No: p1640013




                                                                         Alex Macon
                                                                         Project Test Engineer

         This report may not be reproduced, except in full, without written permission from Compliance Testing.
                              All results contained herein relate only to the sample tested.




                                                                          p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                      Page 1 of 18


Test Report Revision History

  Revision      Date             Revised By    Reason for Revision

     1.0        April 14, 2016   Alex Macon    Original Document

     2.0        April 19, 2016   Amanda Reed   Updated serial number
                                               Removed copy and paste error from PSD table.
     3.0        April 28, 2016   Alex Macon    Updated data rates
                                               Added Mask plots to Annex A
     4.0        April 29, 2016   Alex Macon    Updated Power Spectral Density table




                                                   p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                               Page 2 of 18


                               Table of Contents

Description                                                            Page

 Standard Test Conditions Engineering Practices                         6
 Test Results Summary                                                   8
 Peak Output Power                                                      9
 Transmitter Power Spectral Density                                    11
 Undesirable Emissions Conducted                                       13
 Undesirable Emissions Radiated                                        14
 Occupied Bandwidth                                                    16
 Frequency Stability                                                   17
 Test Equipment Utilized                                               18




                                                   p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                               Page 3 of 18


                                                         ILAC / A2LA


Compliance Testing, LLC, has been accredited in accordance with the recognized International Standard ISO/IEC
17025:2005. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory
quality management system (refer to the joint ISO-ILAC-IAF Communiqué dated January 2009).

The tests results contained within this test report all fall within our scope of accreditation, unless noted below.

Please refer to http://www.compliancetesting.com/labscope.html for current scope of accreditation.

Testing Certificate Number: 2152.01




FCC Site Reg. #349717

IC Site Reg. #2044A-2


       Non-accredited tests contained in this report:

       N/A




                                                                               p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                           Page 4 of 18


The applicant has been cautioned as to the following


15.21 - Information to User

The user’s manual or instruction manual for an intentional radiator shall caution the user that changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

15.27(a) - Special Accessories

Equipment marked to a consumer must be capable of complying with the necessary regulations in the configuration in
which the equipment is marketed. Where special accessories, such as shielded cables and/or special connectors are
required to enable an unintentional or intentional radiator to comply with the emission limits in this part, the equipment
must be marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping or packaging
the special accessories with the unintentional or intentional radiator, the responsible party may employ other methods of
ensuring that the special accessories are provided to the consumer without an additional charge.

Information detailing any alternative method used to supply the special accessories for a grant of equipment authorization
or retained in the verification records, as appropriate. The party responsible for the equipment, as detailed in § 2.909 of
this chapter, shall ensure that these special accessories are provided with the equipment. The instruction manual for such
devices shall include appropriate instructions on the first page of text concerned with the installation of the device that
these special accessories must be used with the device. It is the responsibility of the user to use the needed special
accessories supplied with the equipment.




                                                                             p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                         Page 5 of 18


Standard Test Conditions Engineering Practices

Except as noted herein, the following conditions and procedures were observed during the testing:

In accordance with C63.10-2013 and unless otherwise indicated in the specific measurement results, the ambient
temperature of the actual EUT was maintained within the range of 10° to 40°C (50° to 104°F) unless the particular
equipment requirements specified testing over a different temperature range. Also, unless otherwise indicated, the
humidity levels were in the range of 10% to 90% relative humidity.

Measurement results, unless otherwise noted, are worst-case measurements.

                                               Environmental Conditions
                               Temperature             Humidity                 Pressure
                                  (ºC)                   (%)                     (mbar)
                                23.1 – 24.2            27.6 – 34.2           967.2 – 977.4



EUT Operation during Tests


EUT Description
Model: T00064
Description: Body Worn Camera
Firmware: N/A
Software: N/A
Serial Number: X81002508
Additional Information:
The EUT was placed in needed test modes by the manufacturer who was on site during all testing




                                                                             p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                         Page 6 of 18


EUT Specifications

               Maximum Output Power   18.8 dBm

               Frequency Range        5745 – 5825 MHz

               Bandwidths             20 MHz
                                      802.11a 6/9/12/24/36/48/54 Mbps
               Data Rates
                                      802.11n20: MCS0 – MCS7

Antenna List

  No.                Manufacturer                Part #              Antenna Type          Peak Gain

   1                    Taser             HP-VTS01-43100GN                PIFA               3.9 dBi




15.203: Antenna Requirement:

                                      X   The antenna is permanently attached to the EUT

                                          The antenna uses a unique coupling

                                          The EUT must be professionally installed

                                          The antenna requirement does not apply




           Accessories: None

           Cables: None

           Modifications: None




                                                                  p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                              Page 7 of 18


Test Results Summary

                                                                 Pass,
           Specification                 Test Name                                      Comments
                                                                Fail, N/A
        §15.203                 Antenna Requirements              Pass
        §15.207
                                Line Conducted Emissions           N/A       This is not affected by the C2PC
        §15.407(b)(6)
        §15.407(a)(3)           Conducted Output Power            Pass

        §15.407(a)(3),(5)       Power Spectral Density            Pass

                                6dB Occupied Bandwidth
        §15.403(i)
                                                                  Pass
        §15.407(e)
                                99% Occupied Bandwidth

        §15.407(b)(4)           Undesirable Emissions             Pass
                                General Field Strength Limits
        §15.205
                                (Restricted Bands and             Pass
        §15.407(b)(4),(5),(6)
                                Radiated Emission limits)
        §15.407(g)              Frequency Stability               Pass

        §15.407(f)              RF Exposure                       Pass




     References                       Description

     CFR47, Part 15, Subpart B        Unintentional Radiators

     CFR47, Part 15, Subpart C        Intentional Radiators

     CFR47, Part 15, Subpart E        Unlicensed Nation Information Infrastructure Devices (U-NII)

     ANSI C63.10-2009                 American National standard for testing Unlicensed Wireless Devices
                                      Method and Measurements of Radio-Noise Emissions from low-Voltage
     ANSI C63.4-2009
                                      Electrical and Electronic Equipment in the range 9kHz to 40GHz.
                                      General requirements for the Competence of Testing and Calibrations
     ISO/IEC 17025:2005
                                      Laboratories
     KDB 644545 D03                   Guidance for IEEE 802 11ac New Rules

     KDB 789033 D02                   General U-NII Test Procedures New Rules V01

     KDB 926956 D01                   U-NII Transition Plan




                                                                            p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                        Page 8 of 18


Peak Output Power
Engineer: Alex Macon
Test Date: 4/7/16

                                                      Test Requirements

For the band 5.725-5.85 GHz, the maximum conducted output power over the frequency band of operation shall not
exceed 1 W. If transmitting antennas of directional gain greater than 6 dBi are used, the maximum conducted output
power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-
to-point U-NII devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi
without any corresponding reduction in transmitter conducted power. Fixed, point-to-point operations exclude the use of
point-to-multipoint systems, omnidirectional applications, and multiple collocated transmitters transmitting the same
information. The operator of the U-NII device, or if the equipment is professionally installed, the installer, is responsible for
ensuring that systems employing high gain directional antennas are used exclusively for fixed, point-to-point operations.

                                                        Test Procedure

The RF power was calculated using the spectrum analyzers’ band power function per Method SA-1 from KDB 789033
D02 General U-NII Test Procedures New Rules v01. Measurements were made at the low, mid and high channels of the
band.

The Spectrum analyzer was set to the following:
   a. RBW = 1 MHz
   b. VBW ≥ 3 MHz
   c. Sweep time = auto
   d. Detector = RMS
   e. 100 traces in power averaging mode

                                                          Test Setup


                            EUT                                                                Spectrum
                                                            Attenuator
                                                                                               Analyzer




                                                                                p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                            Page 9 of 18


Test Results

               Bandwidth   Frequency         Level    Limit   Margin
                                       TP                              Mode
                 (MHz)       (MHz)          (dBm)    (dBm)     (dB)
                  20         5745      20   18.5      30      -11.5      A
                  20         5785      20   18.8      30      -11.2      A
                  20         5825      20   18.3      30      -11.7      A
                  20         5745      20   18.8      30      -11.3      N
                  20         5785      20   18.5      30      -11.5      N
                  20         5825      20   18.1      30      -11.9      N




                                                        p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                   Page 10 of 18


Transmitter Power Spectral Density
Engineer: Alex Macon
Test Date: 4/7/16
                                                  Test Requirements

For the band 5.725-5.85 GHz, the maximum power spectral density shall not exceed 30 dBm in any 500 kHz band. If
transmitting antennas of directional gain greater than 6 dBi are used, the maximum power spectral density shall be
reduced by the amount in dB that the directional gain of the antenna exceeds 6 dBi. However, fixed point-to-point U-NII
devices operating in this band may employ transmitting antennas with directional gain greater than 6 dBi without any
corresponding reduction in power spectral density.

                                                    Test Procedure

The Power Spectral Density was measured using the method per SA-1 from KDB 789033 D02 General U-NII Test
Procedures New Rules v01. Measurements were made at the low, mid and high channels of the band. The maximum
PSD was determine by finding the peak value across the carrier bandwidth.

The Spectrum Analyzer was set to the following:

    a.   RBW = 500 KHz.
    b.   VBW ≥ 1500 MHz
    c.   Span 1.5 * BW
    d.   Sweep time = auto
    e.   Detector = RMS
    f.   100 traces in power averaging mode
                                                       Test Setup


                                                                                          Spectrum
                           EUT                          Attenuator
                                                                                          Analyzer




                                                                           p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                      Page 11 of 18


                             Test Results


Bandwidth   Frequency         J3 Level      Limit/500KHz   Margin
                        TP                                          Mode
  (MHz)       (MHz)            (dBm)           (dBm)        (dB)
   20         5745      20       9.7            30         -20.3      A
   20         5785      20       9.6            30         -20.4      A
   20         5825      20       9.3            30         -20.7      A
   20         5745      20       9.6            30         -20.4      N
   20         5785      20       9.6            30         -20.4      N
   20         5825      20       9.0            30         -21.0      N




                                                 p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                            Page 12 of 18


Undesirable Emissions Conducted
Engineer: Alex Macon
Test Date: 4/7/16

                                                  Test Requirements

                               Unwanted Emissions that fall Outside Restricted Bands

For transmitters operating in the 5.725-5.85 GHz band: All emissions within the frequency range from the band edge to 10
MHz above or below the band edge shall not exceed an e.i.r.p. of −17 dBm/MHz; for frequencies 10 MHz or greater
above or below the band edge, emissions shall not exceed an e.i.r.p. of −27 dBm/MHz. The emission measurements shall
be performed using a minimum resolution bandwidth of 1 MHz. A lower resolution bandwidth may be employed near the
band edge, when necessary, provided the measured energy is integrated to show the total power over 1 MHz
The provisions of §15.205 apply to intentional radiators operating under this section.
Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in §15.209.

                            For Conducted Unwanted Emissions in the Restricted Bands

For conducted measurements above 1000 MHz, EIRP was determined and then the field strength computed by the
following:
E[dBμV/m] = EIRP[dBm] - 20 log(d[meters]) + 104.77, where E = field strength and d = 3m
E[dBμV/m] = EIRP[dBm] + 95.2, for d = 3 meters.

                                                    Test Procedure

Per KDB 789033 D02 General U-NII Test Procedures New Rules v01 conducted RF port measurements were made in
lieu of radiated. In addition, Cabinet Emissions measurements were performed in a semi-anechoic chamber with the
antenna port terminated by a matching load. See additional section for Radiated Emissions.

The following criteria were addressed:

The Spectrum Analyzer was set to the following for emissions > 1000MHz:
   a. RBW = 1 MHz
   b. VBW ≥ 3 MHz
   c. Detector = Peak.
   d. Sweep time = auto.
   e. Trace mode = max hold.
      1. Note: For emissions where the peak exceeded that of the average 15.209 emission limit the following was
          performed.
   f. RBW = 1 MHz
   g. VBW ≤ RBW/100 (i.e., 10 kHz) but not less than 10 Hz.

For emissions below 1000MHz the Spectrum Analyzer settings were as follows:
    a. RBW = 100 kHz
    b. VBW ≥ 300 kHz
    c. Detector = Peak.
    d. Sweep time = auto.
    e. Trace mode = max hold.

                                                      Test Setup


                           EUT                          Attenuator                      Spectrum
                                                                                        Analyzer


Test Results:           See Annex A: Undesirable Emissions Conducted

                                                                          p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                     Page 13 of 18


Undesirable Emissions Radiated
Engineer: Alex Macon
Test Date: 4/8/16

                                                   Test Requirements

The provision of §15.209 were applied. In addition the requirements of §15.205 were also applied.

FCC Part 15 Subpart C Paragraph 15.209(a) Limits

                             Frequency                          Frequency                     Frequency
                               (MHz)                        (microvolts/meter)                  (meter)
                             0.009-0.490                        2400/F(kHz)                         300

                             0.490-1.705                       24000/F(kHz)                         30

                               1.705-30                               30                            30

                                30-88                                 100                           3

                               88-216                                 150                           3

                               216-960                                200                           3

                              Above 960                               500                           3

Remarks: E field strength (dBμV/m) = 20 log E field strength (uV/m)

                                                    Test Procedure

The EUT was setup in accordance with ANSI C63.10. 2013 and tested per KDB 789033. The antenna was replaced with
non-radiating matched load. The EUT is placed on non-conductive platform at a height of 0.8 meters above the ground
plane of the semi-anechoic chambers. The EUT was rotated 360 degrees and the receive antenna raised and lowered to
                                                  th
find the maximum emissions from 30MHz to the 10 harmonic of the fundamental. The EUT was set to the maximum
power level allowed and the low, mid, and high channels were investigated for emissions.

The Spectrum Analyzer was set to the following for emissions > 1000MHz:

    a. (RBW = 1 MHz
    b. VBW ≥ 3 MHz
    c. Detector = Peak.
    d. Sweep time = auto.
    e. Trace mode = max hold.
       1. Note: For emissions where the peak exceeded that of the average 15.209 emission limit the following was
           performed.
    f. RBW = 1 MHz
    g. VBW ≤ RBW/100 (i.e., 10 kHz) but not less than 10Hz

For emissions below 1000MHz the Spectrum Analyzer settings were as follows:

    a.   RBW = 100 kHz
    b.   VBW ≥ 300 kHz
    c.   Detector = Peak.
    d.   Sweep time = auto.
    e.   Trace mode = max hold.
         1. Note: A quasi peak detector was used for emissions where the peak exceeded that of the average 15.209
             emission limits

                                                                            p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                       Page 14 of 18


                                            Test Setup below 1000MHz


                            EUT                    Antenna with              Spectrum
                                                     Preamp                  Analyzer




                                            Test Setup above 1000MHz

                                                      Band
         EUT with                 Antenna                                 Amplifier        Spectrum
                                                      Reject
        matching load                                                                      Analyzer
                                                      Filter




Test Results:           See Annex B: Undesirable Emission Radiated




                                                                       p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                  Page 15 of 18


Occupied Bandwidth
Engineer: Alex Macon
Test Date: 4/7/16
                                                   Test Requirement

Within the 5.725-5.85 GHz band, the minimum 6 dB bandwidth of U-NII devices shall be at least 500 kHz. For purposes
of this subpart the emission bandwidth shall be determined by measuring the width of the signal between two points, one
below the carrier center frequency and one above the carrier center frequency, that are 6 dB down relative to the
maximum level of the modulated carrier. Determination of the emissions bandwidth is based on the use of measurement
instrumentation employing a peak detector function with an instrument resolution bandwidth approximately equal to 1.0
percent of the emission bandwidth of the device under measurement

                                                    Test Procedure

The Spectrum analyzer was set to the following parameters
   a. RBW = 100 kHz.
   b. VBW ≥ 300 kHz
   c. Detector = Peak.
   d. Trace mode = max hold.



                                                      Test Setup


                                             EUT                     Spectrum
                                                                     Analyzer




Test Results:           See Annex C: Occupied Bandwidth




                                                                          p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                     Page 16 of 18


Frequency Stability
Engineer: Alex Macon
Test Date: 4/8/16

                                                   Test Requirement

Manufacturers of U-NII devices are responsible for ensuring frequency stability such that an emission is maintained within
the band of operation under all conditions of normal operation as specified in the user’s manual.

                                                     Test Procedure

    a. The EUT was placed into a temperature chamber and the temperature ranges were set to the manufacturers’
       specifications.
    b. The RF output of the EUT was connected to a spectrum analyzer
    c. The lowest and highest channels of the band were set to transmit
    d. The carrier plots were measured to insure that the 6dB band width remained within the band over the prescribed
       temperature extremes.



                                                       Test Setup



                          Temperature Chamber

                                                                      Spectrum
                                   EUT                                Analyzer




Test Results:           See Annex D: Frequency Stability




                                                                            p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                       Page 17 of 18


 Test Equipment Utilized


      Description           Manufacturer               Model #              CT Asset #      Last Cal Date     Cal Due Date

Temperature Chamber        Tenney            Tenney Jr                      i00027                 Verified on: 4/7/16

Horn Antenna, Amplified    ARA               DRG-118/A                      i00271              5/8/14            5/8/16

Horn Antenna, Amplified    ARA               MWH-1826/B                     i00273             4/22/15           4/22/18

Humidity / Temp Meter      Newport           IBTHX-W-5                      i00282              4/1/15            4/1/16

Spectrum Analyzer          Agilent           E4407B                         i00331             9/18/15           9/18/16

Data Logger                Fluke             Hydra Data Bucket              i00343              4/5/16            4/5/17

Bi-Log Antenna             Schaffner         CBL 6111D                      i00349            10/19/15           10/19/17

EMI Analyzer               Agilent           E7405A                         i00379             2/11/16           2/11/17
3 Meter Semi-Anechoic                        3 Meter Semi-Anechoic
                           Panashield                                       i00428             7/27/14           7/27/16
Chamber                                      Chamber
PSA Spectrum Analyzer      Agilent           E4445A                         i00471             8/26/15           8/26/16

 In addition to the above listed equipment standard RF connectors and cables were utilized in the testing of the described
 equipment. Prior to testing these components were tested to verify proper operation.




 END OF TEST REPORT




                                                                             p1640013_FCC_Part 15.407_U-NII-3_Rev 4.0
                                                                                                        Page 18 of 18



Document Created: 2019-10-12 10:20:39
Document Modified: 2019-10-12 10:20:39

© 2024 FCC.report