Test Report

FCC ID: X3A-MG321356M

Test Report

Download: PDF
FCCID_2050414

                                            FCC PART 15.225

                                               TEST REPORT
                                                               For

        Shanghai Smarfid Security Equipment Co., Ltd.
       Room 301, 4th Bldg., No.4 TongLi Road, SongJiang District, Shanghai 201615, China


                                       FCC ID: X3A-MG321356M



             Report Type:                                        Product Type:
             Original Report                                    Magic Series 13.56MHz reader


                  Test Engineer:         Allen Qiao


               Report Number:            R2SH130708053-00


                    Report Date:         2013-08-07


                                         Ivan Cao
                   Reviewed By:          RF Leader

              Test Laboratory:           Bay Area Compliance Laboratories Corp. (Dongguan)
                                         No.69 Pulongcun, Puxinhu Industrial Zone,
                                         Tangxia, Dongguan, Guangdong, China
                                         Tel: +86-769-86858888
                                         Fax: +86-769-86858891
                                         www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report must not be used by the
customer to claim product certification, approval, or endorsement by NVLAP*, or any agency of the Federal Government.
* This report may contain data that are not covered by the NVLAP accreditation and shall be marked with an asterisk “★” (Rev.2)
This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above
version 7.0.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                        Report No.: R2SH130708053-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL CABLE........................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................5
SUMMARY OF TEST RESULTS ...............................................................................................................................6
FCC§15.203 - ANTENNA REQUIREMENT..............................................................................................................7
  APPLICABLE STANDARD ..............................................................................................................................................7
  ANTENNA CONNECTED CONSTRUCTION ......................................................................................................................7
FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST ........................................................................8
  APPLICABLE STANDARD ..............................................................................................................................................8
  MEASUREMENT UNCERTAINTY ....................................................................................................................................8
  EUT SETUP ..................................................................................................................................................................9
  EMI TEST RECEIVER SETUP .........................................................................................................................................9
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................9
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................10
  TEST RESULTS SUMMARY ..........................................................................................................................................10
  TEST DATA ................................................................................................................................................................10
FCC§15.225(E) - FREQUENCY STABILITY..........................................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................12
  TEST DATA ................................................................................................................................................................12
FCC §15.215(C) – 20 DB EMISSION BANDWIDTH ..............................................................................................14
DECALRATION OF SIMILARITY .........................................................................................................................16




FCC Part 15.225                                                                                                                                        Page 2 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: R2SH130708053-00

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The Shanghai Smarfid Security Equipment Co., Ltd.’s product, model number: MW322-8K (FCC ID: X3A-
MG321356M) or ("EUT”) in this report is a Magic Series 13.56MHz reader, which was measured
approximately: 11.5 cm (L) x 8.5 cm (W) x 2.5cm (H), rated input voltage: DC 12.0 V from system.

Note: The series product, model MW322-8K, MX322-8K, MC322-8K, MW322-8N, MX322-8N, MC322-8N
are electrically identical except for model name and with or without buttons ("K" means have buttons, "N"
means have no buttons), we selected MW322-8K for fully testing, and MW322-8N for Radiated Emission
Test, the details was explained in the attached declaration letter.

* All measurement and test data in this report was gathered from production sample serial number: 130708053
 (Assigned by Dongguan BACL). The EUT was received on 2013-07-09.


Objective
This Type approval report is prepared on behalf of Shanghai Smarfid Security Equipment Co., Ltd. in
accordance with Part 2, Subpart J, and Part 15, Subparts A, B and C of the Federal Communication
Commissions rules.

The objective is to determine the compliance of the EUT with FCC rules, sec 15.203, 15.205, 15.207,
15.209 and 15.225.


Related Submittal(s)/Grant(s)
No Related Submittals.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.4-2003, American National
Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the range of 9 kHz to 40 GHz.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




FCC Part 15.225                                                                                  Page 3 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: R2SH130708053-00

Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industrial Zone, Tangxia, Dongguan, Guangdong, China

Test site at Bay Area Compliance Laboratories Corp. (Dongguan) has been fully described in reports
submitted to the Federal Communication Commission (FCC). The details of these reports have been found
to be in compliance with the requirements of Section 2.948 of the FCC Rules on February 02, 2012. The
facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.4-
2003.

The Federal Communications Commission has the reports on file and is listed under FCC Registration No.:
273710. The test site has been approved by the FCC for public use and is listed in the FCC Public Access
Link (PAL) database.


Additionally, Bay Area Compliance Laboratories Corp. (Dongguan) is an ISO/IEC 17025 accredited
laboratory, and is accredited by National Voluntary Laboratory Accredited Program (Lab Code 500069-0).




The current scope of accreditations can be found at http://ts.nist.gov/standards/scopes/5000690.htm




FCC Part 15.225                                                                             Page 4 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: R2SH130708053-00

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a typical fashion (as normally used by a typical user).


EUT Exercise Software
No software was performed under test.


Support Equipment List and Details


       Manufacturer             Description                 Model                     Serial Number
           DELL                     Laptop                  PP11L                   QDS-BRCM1017
       Pro instrument        DC Power Supply              pps3300                           N/A


External Cable

                Cable Description             Length (m)               From                           To
                                                              Serial port of Laptop and
      Shielded Un-detachable Control Cable          3.0                                              EUT
                                                                 DC power Supply


Block Diagram of Test Setup
                                                                                             D C Pow er
                                                                                               Supply


                                                                                                 L aptop




                                                      EUT
                                                                                                      1.0 Meter




                                                                    N on-C onductive T able 80
                                                                    cm above G round Plane


                                                 1.5 M eter




FCC Part 15.225                                                                                       Page 5 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: R2SH130708053-00

SUMMARY OF TEST RESULTS


              FCC Rules                       Description of Test                 Result

                  §15.203                    Antenna Requirement                Compliance
                  §15.207                 AC Line Conducted Emission          Not Applicable*
                §15.225
                                             Radiated Emission Test             Compliance
            §15.209 §15.205
              §15.225(e)                      Frequency Stability               Compliance
              §15.215(c)                   20 dB Emission Bandwidth             Compliance

Not Applicable*: the EUT was powered by DC 12V.




FCC Part 15.225                                                                            Page 6 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: R2SH130708053-00

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
This EUT has an integrated antenna arrangement which fulfills the requirement of this section, and please
refers to the internal photos.

Result: Compliance.




FCC Part 15.225                                                                               Page 7 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                            Report No.: R2SH130708053-00

FCC§15.225, §15.205 & §15.209 - RADIATED EMISSIONS TEST
Applicable Standard
As per FCC Part 15.225
(a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed 15,848
    microvolts/meter at 30 meters.
(b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any emissions
    shall not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any emissions
    shall not exceed 106 microvolts/meter at 30 meters.
(d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band shall not exceed
    the general radiated emission limits in §15.209.

Measurement Uncertainty
Compliance or non- compliance with a disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level exceeds the disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level exceeds the disturbance limit.
If Ulab is greater than Ucispr of Table 1, then:
–compliance is deemed to occur if no measured disturbance level, increased by (Ulab − Ucispr), exceeds the
disturbance limit;
–non - compliance is deemed to occur if any measured disturbance level, increased by (Ulab − Ucispr),
exceeds the disturbance limit.

Based on CISPR 16-4-2: 2011, measurement uncertainty of radiated emission at a distance of 3m at Bay
Area Compliance Laboratories Corp. (Dongguan) is:
30M~200MHz: 5.0 dB
200M~1GHz: 6.2 dB
1G~6GHz: 4.45 dB
6G~18GHz: 5.23 dB
                                      Table 1 – Values of Ucispr

                                        Measurement                                             Ucispr
Radiated disturbance (electric field strength at an OATS or in a SAC) (30 MHz to 1000 MHz)     6.3 dB
Radiated disturbance (electric field strength in a FAR)           (1 GHz to 6 GHz)             5.2 dB
Radiated disturbance (electric field strength in a FAR)           (6 GHz to 18 GHz)            5.5 dB




FCC Part 15.225                                                                               Page 8 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: R2SH130708053-00

EUT Setup




The radiated emission tests were performed in the 3-meter chamber a test site, using the setup accordance
with the ANSI C63.4-2003. The specification used was the FCC Part Subpart C limits.

The spacing between the peripherals was 10 cm.

The EUT was connected to 12V DC power source.


EMI Test Receiver Setup
According to FCC Rules, 47 CFR 15.33, the EUT emissions were investigated up to 1000 MHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                      Frequency Range               RBW        Video B/W          Detector
                       9kHz – 150 kHz            300 Hz          1 kHz              QP
                      150KHz – 30 MHz            10 kHz          30 kHz             QP
                     30MHz – 1000 MHz            100 kHz        300 kHz             QP


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Loss and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

        Corr. Ampl. = Meter Reading + Antenna Loss+ Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the maximum limit. The equation
for margin calculation is as follows:

        Margin = Limit - Corr. Ampl.




FCC Part 15.225                                                                              Page 9 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: R2SH130708053-00

Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
                            EMI TEST
         R&S                                        ESCI             100224          2013-5-6       2014-5-5
                            RECEIVER
         Sunol
                              Antenna                JB3            A060611-1        2012-9-6       2015-9-5
       Sciences
          HP              HP AMPLIFIER              8447E          2434A02181           N/A           N/A
      The Electro-
       Mechanics       Passive Loop Antenna          6512           9706-1206       2012-11-30     2015-11-29
       Company

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed in accordance to NVLAP requirements, traceable to National Primary Standards and International
System of Units (SI).


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209 with the worst
margin reading of:

                             11.48 dB at 35.82 MHz in the Vertical polarization


Test Data
     Environmental Conditions

             Temperature:               24.8 C
       Relative Humidity:                 57 %
           ATM Pressure:                99.8kPa

     * The testing was performed by Allen Qiao on 2013-08-01.


    Test mode: Transmitting(MW322-8K was the worst)




FCC Part 15.225                                                                                   Page 10 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: R2SH130708053-00


1) Spurious Emissions (9 kHz~30 MHz):

Frequency                Receiver                                            Corrected              FCC 15.225
                                                       Cable    Amplifier
                                           Factor                            Amplitude
                                                        loss     Gain                         Limit @
             Reading          Detector   (dB(1/m))                             @ 3m                           Margin
  (MHz)                                                (dB)       (dB)                          3m
             (dBμV)         (PK/QP/AV)                                       (dBμV/m)                          (dB)
                                                                                             (dBμV/m)
    0.95       22.21                QP     48.10        0.76      21.50           49.57        69.50              19.93
    5.63       18.24                QP     34.30        0.76      21.50           31.80        69.50              37.70
   13.21          11.7              QP     32.10        0.76      21.50           23.06           80.50           57.44
  13.415       17.37                QP     32.10        0.76      21.50           28.73           90.50           61.77
   13.56       33.71                QP     32.10        0.76      21.50           45.07           124.00          78.93
  13.575       16.91                QP     32.10        0.76      21.50           28.27           90.50           62.23
  13.805       14.72                QP     32.10        0.76      21.50           26.08           80.50           54.42
  21.561       13.72                QP     31.30        0.76      21.50           24.28           69.50           45.22



2) Spurious Emissions (30 MHz ~1 GHz):

                         Receiver         Rx Antenna           Cable   Amplifier     Corrected
Frequency                                                                                                 Limit      Margin
             Reading          Detector   Polar     Factor       loss    Gain         Amplitude

   MHz        dBμV          PK/QP/AV     H/V       dB(1/m)      dB          dB        dBμV/m          dBμV/m              dB
   35.82          21.6          QP        H          17.67     0.77       21.42           18.62           40.00       21.38
   35.82          31.5          QP        V          17.67     0.77       21.42           28.52           40.00       11.48
  108.57          25.9          QP        H          12.63     1.27       21.41           18.39           43.50       25.11
  108.57          38.1          QP        V          12.63     1.27       21.41           30.59           43.50       12.91




FCC Part 15.225                                                                                            Page 11 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: R2SH130708053-00

FCC§15.225(e) - FREQUENCY STABILITY
Applicable Standard
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency
over a temperature variation of −20 degrees to +50 degrees C at normal supply voltage, and for a variation
in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees
C. For battery operated equipment, the equipment tests shall be performed using a new battery.


Test Procedure
Frequency Stability vs. Temperature: The equipment under test was connected to PC, than to an external
AC power supply and loop antenna was connected to a f Spectrum Analyzer. The EUT was placed inside
the temperature chamber.

After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
Spectrum Analyzer.

Frequency Stability vs. Voltage: An external variable AC power supply Source. The voltage was set to
115% of the nominal value and was then decreased until the transmitter light no longer illuminated; i.e.,
the end point. The output frequency was recorded for each voltage.


Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
     Manufacturer             Description            Model
                                                                    Number            Date         Due Date
          R&S              Spectrum analyzer         FSP 38         100478         2013-6-16       2014-6-15
      Dongzhixu              Humidity tester        DP1000        201105083-3       2013-7-3       2014-7-2
      The Electro-
       Mechanics         Passive Loop Antenna         6512         9706-1206       2012-11-30     2015-11-29
       Company

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed in accordance to NVLAP requirements, traceable to National Primary Standards and International
System of Units (SI).


Test Data
     Environmental Conditions

             Temperature:              28.8 °C
        Relative Humidity:               59 %
            ATM Pressure:              99.8 kPa

   The testing was performed by Allen Qiao on 2013-08-01.




FCC Part 15.225                                                                                   Page 12 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: R2SH130708053-00

   Test Mode: Transmitting

   Test Result: Pass


                                             fo = 13.56 MHz
                                               Measured
              Temperature        Voltage                      Frequency
                                               frequency                         Limit
                                                                Error
                    ℃              VDC              MHz
                   -20             12          13.56088       0.0065%           ±0.01%
                   -10             12           13.5609       0.0066%           ±0.01%
                       0           12          13.56088       0.0065%           ±0.01%
                    10             12          13.56092       0.0068%           ±0.01%
                    20             12          13.56085       0.0063%           ±0.01%
                    30             12          13.56086       0.0063%           ±0.01%
                    40             12           13.5609       0.0066%           ±0.01%
                    50             12          13.56089       0.0066%           ±0.01%
                    25            13.8         13.56088       0.0065%           ±0.01%
                    25            10.2         13.56087       0.0064%           ±0.01%




FCC Part 15.225                                                                          Page 13 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: R2SH130708053-00

FCC §15.215(c) – 20 dB EMISSION BANDWIDTH
Applicable Standard
Per FCC §15.215 (c) Intentional radiators operating under the alternative provisions to the general
emission limits, as contained in §15.217 through § 15.257 and in Subpart E of this part, must be designed
to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in
the specific rule section under which the equipment operates, is contained within the frequency band
designated in the rule section under which the equipment is operated. The requirement to contain the
designated bandwidth of the emission within the specified frequency band includes the effects from
frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as
the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a
frequency stability is not specified in the regulations, it is recommended that the fundamental emission be
kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of -
band operation.

Test Procedure
1        Check the calibration of the measuring instrument using either an internal calibrator or a known
signal from an external generator.
2        Position the EUT without connection to measurement instrument. Turn on the EUT and connect it
to measurement instrument. Then set it to any one convenient frequency within its operating range. Set a
reference level on the measuring instrument equal to the highest peak value.
3        Measure the frequency difference of two frequencies that were attenuated 20 dB from the
reference level. Record the frequency difference as the emission bandwidth.

Test Equipment List and Details

                                                             Serial          Calibration    Calibration
   Manufacturer        Description                Model
                                                             Number          Date           Due Date

      R&S                Spectrum analyzer        FSP 38        100478        2013-6-16      2014-6-15
   The Electro-            Passive Loop
                                                   6512        9706-1206     2012-11-30     2015-11-29
Mechanics Company            Antenna

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed in accordance to NVLAP requirements, traceable to National Primary Standards and International
System of Units (SI).


Test Data Environmental Conditions


             Temperature:              28.8 °C
        Relative Humidity:               59 %
            ATM Pressure:              99.8 kPa

   The testing was performed by Allen Qiao on 2013-08-01.



FCC Part 15.225                                                                                   Page 14 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)               Report No.: R2SH130708053-00

Test Mode: Transmitting

                                     20 dB Emission Bandwidth




FCC Part 15.225                                                                  Page 15 of 16


Bay Area Compliance Laboratories Corp. (Dongguan)     Report No.: R2SH130708053-00

DECALRATION OF SIMILARITY




                                *****END OF REPORT*****

FCC Part 15.225                                                        Page 16 of 16



Document Created: 2013-08-21 10:36:34
Document Modified: 2013-08-21 10:36:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC