         CERPASS TECHNOLOGY (SUZHOU)CO., LTD                         Report No.: SEFU1909089




                          RF Exposure Report

         Applicant      : LIFEWORKS TECHNOLOGY GROUP LLC.
         Address        : 1412 Broadway New York, NY 10018
         Equipment : Wireless charging Car Mount
         Model No.      : IHBLQI3000B
         Trademark : iHome
         FCC ID         : WWEIHQI3000



     I HEREBY CERTIFY THAT :
     The sample was received on Sept. 19, 2019 and the test items were conducted during Sept.
     25, 2019 at Cerpass Technology (Suzhou) Co., Ltd. The test result refers exclusively to the
     test presented test model / sample. Without written approval of Cerpass Technology (Suzhou)
     Co., Ltd., the test report shall not be reproduced except in full.



 Approved by:                         Laboratory Accreditation:
                                        Cerpass Technology Corporation Test Laboratory

                                          TAF LAB Code:               1439
                                        Cerpass Technology (SuZhou) Co., Ltd.

 Miro Chueh                                A2LA LAB Code:              4981.01
 EMC/RF Manager




CERPASS TECHNOLOGY (SUZHOU)CO., LTD                                      Issued Date : Sept. 25, 2019
                                                                         Page No.    :   1 of 6


              CERPASS TECHNOLOGY (SUZHOU)CO., LTD                                                                   Report No.: SEFU1909089

                                                                         CONTENTS


 1. Summary Of Standards And Results ........................................................................................................ 3
   1.1. Measuring Standard .................................................................................................................................. 3
   1.2. Requirements ............................................................................................................................................ 3
   1.3. Typical test Setup ...................................................................................................................................... 4
   1.4. Specification Limits.................................................................................................................................... 4
   1.5. Test Equipment List and Details................................................................................................................ 5
   1.6. Test Result ................................................................................................................................................ 5
   1.7. Photographs of test setup ......................................................................................................................... 6




CERPASS TECHNOLOGY (SUZHOU)CO., LTD                                                                                        Issued Date : Sept. 25, 2019
                                                                                                                           Page No.            :   2 of 6


            CERPASS TECHNOLOGY (SUZHOU)CO., LTD                              Report No.: SEFU1909089


1. Summary Of Standards And Results
1.1. Measuring Standard
    The EUT have been tested according to the applicable standards as referenced below:
          Test Item              Normative References                Remarks
                               FCC CFR 47 part1, 1.1310
         RF Exposure                                                  PASS
                                 KDB680106 D01v03



1.2. Requirements
 According to the item 5 of KDB 680106 D01v03:
  Inductive wireless power transfer applications that meet all of the following requirements are
 excluded from submitting an RF exposure evaluation.


 a) Power transfer frequency is less that 1 MHz
 b) Output power from each primary coil is less than or equal to 15 watts
 c) The transfer system includes only single primary and secondary coils. This includes charging
 systems that may have multiple primary coils and clients that are able to detect and allow
 coupling only between individual pairs of coils
 d) Client device is inserted in or placed directly in contact with the transmitter
 e) Mobile exposure conditions only(portable exposure conditions are not covered by this
 exclusion).
 f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
 surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the
 MPE limit..
 Remark: Meet all the above requirements.




  CERPASS TECHNOLOGY (SUZHOU)CO., LTD                                            Issued Date : Sept. 25, 2019
                                                                                 Page No.    :   3 of 6


           CERPASS TECHNOLOGY (SUZHOU)CO., LTD                    Report No.: SEFU1909089

1.3. Typical test Setup




1.4. Specification Limits
 The criteria listed in the following table shall be used to evaluate the environment impact of
 human exposure to radio frequency (RF) radiation as specified in 1.1307(b) Limits for Maximum
 Permissible Exposure (MPE)




  CERPASS TECHNOLOGY (SUZHOU)CO., LTD                                 Issued Date : Sept. 25, 2019
                                                                      Page No.    :   4 of 6


           CERPASS TECHNOLOGY (SUZHOU)CO., LTD                         Report No.: SEFU1909089

1.5. Test Equipment List and Details
    Instrument        Manufacturer           Model No           Serial No     Calibration Date Valid Date
    EMIF Tester          Narda               ELT-400            G-0041             2019/01/16      2020/01/15



1.6. Test Result
  Electric Field Strength at 15 cm surrounding the EUT and 20cm above the top surface of
  the EUT
                   Frequency      Test       Test result(v/m)        Limit (v/m)
                     Range       Position
                     (KHz)
                   110~205       A: Front         0.374                614.00
                   110~205       B: Back          0.316                614.00
                   110~205        C: Left         0.422                614.00
                   110~205       D: Right         0.412                614.00
                   110~205        E: Top          0.482                614.00
                   110~205       F: Bottom        0.406                614.00
  Magnetic Field Strength at 15 cm surrounding the EUT and 20cm above the top surface
  of the EUT
                   Frequency      Test       Test result(A/m)        Limit (A/m)
                     Range       Position
                     (KHz)
                   110~205       A: Front         0.315                     1.63
                   110~205       B: Back          0.321                     1.63
                   110~205        C: Left         0.332                     1.63
                   110~205       D: Right         0.208                     1.63
                   110~205        E: Top          0.297                     1.63
                   110~205       F: Bottom        0.264                     1.63




  CERPASS TECHNOLOGY (SUZHOU)CO., LTD                                         Issued Date : Sept. 25, 2019
                                                                              Page No.     :    5 of 6


          CERPASS TECHNOLOGY (SUZHOU)CO., LTD   Report No.: SEFU1909089

1.7. Photographs of test setup




  CERPASS TECHNOLOGY (SUZHOU)CO., LTD              Issued Date : Sept. 25, 2019
                                                   Page No.    :   6 of 6



Document Created: 2019-10-14 17:33:06
Document Modified: 2019-10-14 17:33:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC