RF Exposure

FCC ID: WWEIHQI2114

RF Exposure Info

Download: PDF
FCCID_4453653

                         FCC TEST REPORT
                          FCC ID: WWEIHQI2114
                                   On Behalf of

               LIFEWORKS TECHNOLOGY GROUP LLC.
                 Airstand Wireless Charging
    Model No.: IHQI2114B-WM, IHQI2114N-WM, IHQI2112,
       IHQI2114, IHQI2114-WM, IHQI2115, IHQI2115-AZ




Prepared for       : LIFEWORKS TECHNOLOGY GROUP LLC.
Address            : 1412 Broadway, New York, United States 10018




Prepared By        : Shenzhen Alpha Product Testing Co., Ltd.
                     Building i, No.2, Lixin Road, Fuyong Street, Bao'an District,
Address            :
                     518103, Shenzhen, Guangdong, China




                Report Number        :   A1908188-C01-R02
                Date of Receipt      :   August 23, 2019
                Date of Test         :   August 23, 2019–August 30, 2019
                Date of Report       :   September 02, 2019
                Version Number       :   V0


                                                                   Page 2 of 13                            Report No.: A1908188-C01-R02


                                                      TABLE OF CONTENTS

1. Test Result Summary .............................................................................. 5
2. EUT Description ....................................................................................... 6
     2.1. DESCRIPTION OF DEVICE (EUT) ............................................................................................................. 6
     2.2. ACCESSORIES OF DEVICE (EUT)............................................................................................................ 7
     2.3. TESTED SUPPORTING SYSTEM DETAILS ................................................................................................. 7
     2.4. BLOCK DIAGRAM OF CONNECTION BETWEEN EUT AND SIMULATORS ....................................................... 7
     2.5. DESCRIPTION OF TEST MODES ............................................................................................................... 7
     2.6. TEST CONDITIONS ................................................................................................................................. 7
     2.7. TEST FACILITY ...................................................................................................................................... 8
     2.8. MEASUREMENT UNCERTAINTY ............................................................................................................... 8

3. Test Results and Measurement Data ..................................................... 9
     3.1. RF EXPOSURE TEST ......................................................................................................................... 9

4. Photos of test setup .............................................................................. 12
5. Photographs of EUT .............................................................................. 13


                                           Page 3 of 13           Report No.: A1908188-C01-R02


                       TEST REPORT DECLARATION
Applicant          : LIFEWORKS TECHNOLOGY GROUP LLC.
Address            : 1412 Broadway, New York, United States 10018
Manufacturer       : LIFEWORKS TECHNOLOGY GROUP LLC.
Address            : 1412 Broadway, New York, United States 10018
EUT Description    : Airstand Wireless Charging
                                          IHQI2114B-WM, IHQI2114N-WM, IHQI2112,
                     (A) Model No.      : IHQI2114, IHQI2114-WM, IHQI2115,
                                          IHQI2115-AZ
                     (B) Trademark      : iHome


Measurement Standard Used:
FCC CFR Title 47 Part 15 Subpart C
FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03


The device described above is tested by Shenzhen Alpha Product Testing Co., Ltd. to
determine the maximum emission levels emanating from the device and the severe levels
of the device can endure and its performance criterion. The test results are contained in
this test report and Shenzhen Alpha Product Testing Co., Ltd. is assumed full
responsibility for the accuracy and completeness of test. Also, this report shows that the
EUT is technically compliant with the FCC CFR Title 47 Part 15 Subpart C requirements.


This report applies to above tested sample only. This report shall not be reproduced in
parts without written approval of Shenzhen Alpha Product Testing Co., Ltd.




                                               Ella Liang
Tested by (name + signature)........…..:
                                               Project Engineer
                                                                   ……………………………

                                               Simple Guan
Approved by (name + signature)…....:
                                               Project Manager
                                                                   ……………………………

Date of issue…… …………………..:                     September 02, 2019


                                      Page 4 of 13            Report No.: A1908188-C01-R02



                                Revision History
Revision       Issue Date                 Revisions                   Revised By
  V0       September 02, 2019        Initial released Issue           Simple Guan


                                                      Page 5 of 13          Report No.: A1908188-C01-R02


1. Test Result Summary

          Requirement                                   CFR 47 Section                  Result

         RF EXPOSURE                          §1.1307(b)(1) & KDB680106                 PASS
 Note:
    1. PASS: Test item meets the requirement.

    2. Fail: Test item does not meet the requirement.

    3. N/A: Test case does not apply to the test object.

    4. The test result judgment is decided by the limit of test standard.


                                         Page 6 of 13              Report No.: A1908188-C01-R02


2. EUT Description
2.1. Description of Device (EUT)
EUT Name                 :   Airstand Wireless Charging

Model No.                :   IHQI2114B-WM, IHQI2114N-WM, IHQI2112, IHQI2114,
                             IHQI2114-WM, IHQI2115, IHQI2115-AZ
                             All model’s the function, software and electric circuit are the
                             same, except the color and model number are different, the
DIFF.                    :   color is divided into black, Navy, Brown, White, Coral and
                             Pastel Green. this report performs the model
                             IHQI2114B-WM.
Trademark                :   iHome
Power supply             :   Input : 5V/2.0A, 9V/1.67A
                             Wireless Output : 5W/7.5W/10W
Operation frequency      :   125-205KHz
Modulation               :   MSK
Antenna Type             :   Coil Antenna


Software version         :   V1.0
Hardware version         :   S01D190719


           Conditions requirement                                      Answers
Power transfer frequency is less than 1 MHz.            After measuring the product the
                                                        transfer frequency is 125-205KHz
Output power from each primary coil is less than        After measuring the product the each
or equal to 15 watts.                                   primary coil power is 5 watts
The transfer system includes only single primary        The wireless charger has two primary
and secondary coils. This includes charging             coils, two primary coils work together
systems that may have multiple primary coils            when TX.
and clients that are able to detect and allow
coupling only between individual pairs of coils.
Client device is placed directly in contact with the    Client device is placed directly in
transmitter.                                            contact with the transmitter.
Mobile exposure conditions only (portable               Mobile exposure conditions only.
exposure conditions are not covered by this
exclusion).
The aggregate H-field strengths at 15 cm                After measuring the product the Max
surrounding the device and 20 cm above the top          H-field Strength is 0.38A/m Far less
surface from all simultaneous transmitting coils        than 50% of the MPE limit.
are demonstrated to be less than 50% of the
MPE limit.


                                                Page 7 of 13               Report No .: A1908188—C01—RO2




2.2. Accessories of Device (EUT)
Accessories1         :    /
Manufacturer              /
Model                     /
Ratings                   /

2.3. Tested Supporting System Details
  No.        Description       Manufacturer            Model         Serial Number    Certlfg:oagon or

   1         mobile phone       SAMSUNG             SM—G9350               ——                  ——
   2           Adapter                 ——                 ——               ——                  ——


2.4. Block Diagram of connection between EUT and simulators

                                 Load



                                 EUT            Adapter        > AC 120V/60Hz




2.5. Description of Test Modes
Channel         Fr?&lfiir)lcy   Channel      Fri%fi?cy      Channel     Fri%fi?cy    Channel     Fri%fi?cy

       1            125          6            150              11        175         16             200
       2            130          7            155              12        180         17             205
       3            135          8            160              13        185         18
       4            140          9            165              14        190         19
       5            145          10           170              15        195         20


 2.6. Test Conditions
                 Items                                 Required                           Actual
           Temperature range:                          15—35°C                              24°C
            Humidity range:                            25—75%                               56%
            Pressure range:                         86—106kPa                             98kPa


                                      Page 8 of 13           Report No.: A1908188-C01-R02




2.7. Test Facility
Shenzhen Alpha Product Testing Co., Ltd
Building i, No.2, Lixin Road, Fuyong Street, Bao'an District, 518103, Shenzhen,
Guangdong, China

June 21, 2018 File on Federal Communication Commission
Registration Number: 293961

July 15, 2019 Certificated by IC
Registration Number: CN0085


2.8. Measurement Uncertainty
(95% confidence levels, k=2)
                          Item                                     Uncertainty

         Uncertainty for Conducted Emission Test                       2.74dB

  Uncertainty for Radiation Emission test in 3m chamber                3.77dB
                    (30MHz to 1GHz)                                    3.80dB
  Uncertainty for Radiation Emission test in 3m chamber               4.16dB
                     (1GHz to 25GHz)                                  4.13dB
              Uncertainty for radio frequency                         5.4×10-8
        Uncertainty for Conducted Emission Test                       2.74dB
  Uncertainty for Radiation Emission test in 3m chamber
                                                                       3.77dB
                    (30MHz to 1GHz)
          Uncertainty for conducted RF Power                           0.65dB
               Uncertainty for temperature                              0.2℃
                  Uncertainty for humidity                               1%
     Uncertainty for DC and low frequency voltages                     0.06%


                                   Page 9 of 13          Report No.: A1908188-C01-R02


3.      Test Results and Measurement Data
3.1. RF EXPOSURE TEST
3.1.1. Test Specification

     Test Requirement:      FCC Rules and Regulations KDB680106
     Test Method:           §1.1307(b)(1) & KDB680106
                            According to §1.1307(b)(1), systems operating under the
                            provisions of this section shall be
                            operated in a manner that ensures that the public is not
                            exposed to radio frequency energy
     Limits:                level in excess of the Commission’s guidelines.
                            According to §1.1310 and §2.1093 RF
                            exposure is calculated. According KDB680106 D01v03:
                            RF Exposure Wireless Charging
                            Apps v02.




     Test Setup:




                                               E to position is 20cm.
                            1. The RF exposure test was performed on 360 degree
                               turn table in anechoic chamber.
                            2. The measurement probe was placed at test distance
                               (15cm) which is between the edge of the charger and
                               the geometric centre of probe.
                            3. The turn table was rotated 360d degree to search of
     Test Procedure:
                               highest strength.
                            4. The highest emission level was recorded and
                               compared with limit as soon as measurement of each
                               points (A, B, C, D, E) were completed.
                            5. The EUT were measured according to the dictates of
                               KDB 680106D01v03.
     Test Result:           PASS


                                  Page 10 of 13                Report No.: A1908188-C01-R02


3.1.2. Test Instruments
                                                                                  Cal.
 Item Equipment Manufacturer      Model No.       Serial No.     Last Cal.
                                                                                Interval
         Exposure
  1.                      narda   ELT-400          N-0231       2018.09.26       1 Year
       Level Tester
         Magnetic
                                  ELT probe
  2     field probe       narda                    M0675        2018.09.26       1 Year
                                   100cm2
          100cm2


                                        Page 11 of 13            Report No.: A1908188-C01-R02



  3.1.3. Test data

For Full load mode:
E-Filed Strength at 15 cm from the edges surrounding the EUT (V/m)
Frequency Test          Test       Test      Test       Test            Limit        Limits
Range         Position Position    Position Position Position          (50%)          Test
(MHz)         A         B          C         D          E              (V/m)         (V/m)
0.205         1.43      1.42       1.42      1.40       1.41            307           614

H-Filed Strength at 15 cm from the edges surrounding the EUT (A/m)
Frequency Test          Test       Test       Test      Test             Limit       Limits
Range        Position Position     Position Position Position           (50%)         Test
(MHz)        A          B          C          D         E               (A/m)        (A/m)
0. 205       0.38       0.36       0.37       0.37      0.36            0.815         1.63

Remark: All modes have been tested. This Report only show the test result of the worst case
(Full load).


                          Page 12 of 13   Report No.: A1908188-C01-R02


4. Photos of test setup
For Full load mode




For No load mode


                                   Page 13 of 13    Report No.: A1908188-C01-R02


5. Photographs of EUT
    Refer to test report A1908188-C01-R01.

                                  ------End------



Document Created: 2019-09-18 07:56:54
Document Modified: 2019-09-18 07:56:54

© 2024 FCC.report