15C RF test report

FCC ID: WUI-LM57176

Test Report

Download: PDF
FCCID_4416579

Report Number: 68.940.19.0030.01




                                                          FCC/IC - TEST REPORT



  Report Number                                          : 68.940.19.0030.01                              Date of Issue:                     August 02, 2019


 Model                                                   : LM57176

 Product Type                                            : Microwave sensor for Ceiling light

 Applicant                                               : Winplus Co., Ltd.

 Address                                                 : Suites 6-11, 7th Floor, Corporation Park, 11 On Lai Street, Shatin,

                                                             Hong Kong

 Manufacture                                             : Winplus Co., Ltd.

 Address                                                 : Suites 6-11, 7th Floor, Corporation Park, 11 On Lai Street, Shatin,

                                                             Hong Kong


  Test Result                                            :  Positive                    Negative



  Total pages including
  Appendices                                             : 27




TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined
in ISO 17025.

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test
conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this
model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe
for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co.,
Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and
Testing (China) Co., Ltd. Shenzhen Branch issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




 EMC_SZ_FR_23.00 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                           Page 1 of 27
                                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 1 Table of Contents

  1 Table of Contents................................................................................................................................................................. 2
  2 Details about the Test Laboratory ........................................................................................................................................ 3
  3 Description of the Equipment Under Test ........................................................................................................................... 4
  4 Summary of Test Standards ................................................................................................................................................. 5
  5 Summary of Test Results ..................................................................................................................................................... 6
  6 General Remarks ................................................................................................................................................................. 7
  7 Test setups ........................................................................................................................................................................... 8
  8 Technical Requirement ........................................................................................................................................................ 9
     8.1 Conducted Emission ..................................................................................................................................................... 9
     8.2 Field strength of emissions and Restricted bands ....................................................................................................... 12
     Field strength of emissions and Restricted bands ............................................................................................................. 13
     8.3 Out of Band Emissions ............................................................................................................................................... 17
     8.4 20dB Bandwidth & 99% Occupied Bandwidth .......................................................................................................... 22
  9 Test equipment lists ........................................................................................................................................................... 26
  10 System Measurement Uncertainty ................................................................................................................................... 27




 EMC_SZ_FR_23.00 FCC                                         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                       Page 2 of 27
                                                 Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                             District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 2 Details about the Test Laboratory

 Details about the Test Laboratory

 Test Site 1

 Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                       Building 12&13, Zhiheng Wisdomland Business Park,
                       Nantou Checkpoint Road 2, Nanshan District,
                       Shenzhen City, 518052,
                       P. R. China

 FCC Registration      514049
 Number:

 ISED#:                10320A

 CAB identifier:       CN0077

 Telephone:            86 755 8828 6998
 Fax:                  86 755 8828 5299




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 3 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 3 Description of the Equipment Under Test

 Description of the Equipment Under Test

 Product/PMN:                      Microwave sensor for Ceiling light

 Model no./HVIN:                   LM57176

 HMN:                              LED Ceiling light with ambiance glow

 FCC ID:                           WUI-LM57176

 IC:                               7297A-LM57176

 Options and accessories:          NIL

 Ratings:                          8-12VDC (Supplied by LED driver)

 RF Transmission                   5734MHz - 5858MHz
 Frequency:

 Modulation:                       Unmodulated

 Antenna Type:                     PCB

 Antenna Gain:                     1.62dBi

 Description of the EUT:           The product is a Microwave sensor for Ceiling light that
                                   operated at 5.8GHz,
                                   The TX and RX range is 5734MHz - 5858MHz

Auxiliary Equipment Used during Test:

        DESCRIPTION            MANUFACTURER                              RATINGS                       MODEL NO.(SHIELD)
       LED Ceiling Light              WINPLUS                 Input: 120VAC/60Hz,                               LM57176
                                                              24W Max




 EMC_SZ_FR_23.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 4 of 27
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20        District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 4 Summary of Test Standards

                                   Test Standards
 FCC Part 15 Subpart C PART 15 - RADIO FREQUENCY DEVICES
 10-1-2017 Edition     Subpart C - Intentional Radiators
 RSS-Gen               General Requirements and Information for the Certification of
 Issue 5, Amendment 1, Radio Apparatus
 March 2019
 RSS-210 Issue 9       RSS-210 — Licence-exempt Radio Apparatus (All Frequency
 August 2016           Bands): Category I Equipment

All the test methods were according to ANSI C63.10-2013.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 5 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 5 Summary of Test Results

                               Technical Requirements
 FCC Part 15 Subpart C 15.249, RSS-Gen, RSS-210
 Test Condition                                   Pages                                      Test             Test Result
                                                                                              Site         Pass Fail N/A
 15.207 & RSS-Gen A8.8                                                              9        Site 1
 Conducted emission AC power port
 §15.205(a), §15.209(a), §15.249(a), §15.249(c) &                                  12        Site 1
 RSS-210 B.10, RSS-GEN 6.13/8.9/8.10
 Field strength of emissions and Restricted bands
 §15.249(d), RSS-210 B.10                                                          21        Site 1
 Out of band emissions
 FCC §15.215(c) 20dB bandwidth                                                     26        Site 1
 & RSS-Gen 6.7 99% Occupied Bandwidth
 §15.203, RSS-GEN 6.8                                                             See note 1
 Antenna requirement

Remark 1: N/A- Not Applicable;
Note 1: The EUT used an integral PCB antenna, which gain is 1.62dBi. According to §15.203,
it is considered sufficiently to comply with the provisions of this section.
Note 2: The radio module do not has shielded cover, so it was tested with a host for this
modular approve application, the host information as below :
Company name: Winplus Co., Ltd.
Product/PMN: LED Ceiling light with ambiance glow
Model no./HVIN: LM57176




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 6 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 6 General Remarks

Remarks
This submittal(s) (test report) is intended for FCC ID: WUI-LM57176 and IC: 7297A-LM57176
complies with Section 15.207, 15.205, 15.209, 15.249 of the FCC Part 15, Subpart C Rules;
RSS-Gen Issue 5 and RSS-210 issue 9.


SUMMARY:

All tests according to the regulations cited on page 5 were


 - Performed

 - Not Performed

The Equipment Under Test

 - Fulfills the general approval requirements.

 - Does not fulfill the general approval requirements.


 Sample Received Date:                        July 10, 2019

 Testing Start Date:                          July 10, 2019

 Testing End Date:                            July 19, 2019


- TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -
 Reviewed by:                           Prepared by:                                     Tested by:




   _______________________                   _______________________                            _______________________
       Laurent Yuan                           Henry Chen                                               Louise Liu
    EMC Project Manager                    EMC Project Engineer                                     EMC Test Engineer




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 7 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 7 Test setups

7.1 AC Power Line Conducted Emission test setups




7.2 Radiated test setups

Below 1GHz




Above 1GHz




 EMC_SZ_FR_23.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 8 of 27
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20        District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 8 Technical Requirement

8.1 Conducted Emission
Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through a Artificial Mains
      Network (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit

                        Frequency                         QP Limit                        AV Limit
                           MHz                             dBμV                            dBμV
                        0.150-0.500                        66-56*                          56-46*
                          0.500-5                            56                              46
                            5-30                             60                              50

*Decreasing linearly with logarithm of the frequency.




 EMC_SZ_FR_23.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 9 of 27
                            Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20        District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Conducted Emission
 Product Type                :     Microwave sensor for Ceiling light
 M/N                         :     LM57176
 Operating Condition         :     Normal working with transmitting
 Test specification          :     Positive
 Comment                     :     AC 120V/60Hz (Powered by Ceiling Light)
             Level in dBµV




                                 Frequency      QuasiPeak        Average       Limit      Margin      Line     Corr.
                                   (MHz)         (dBµV)           (dBµV)      (dBµV)       (dB)                (dB)
                                    0.162500            ---         24.49       55.34       30.85     L1        10.2
                                    0.162500         51.58             ---      65.34       13.76     L1        10.2
                                    0.229500            ---         25.32       52.47       27.15     L1        10.2
                                    0.229500         46.55             ---      62.47       15.92     L1        10.2
                                    0.381500            ---         25.31       48.25       22.94     L1        10.3
                                    0.381500         41.60             ---      58.25       16.65     L1        10.3
                                    0.537500            ---         19.08       46.00       26.92     L1        10.3
                                    0.537500         41.45             ---      56.00       14.55     L1        10.3
                                    0.705500            ---         19.84       46.00       26.16     L1        10.3
                                    0.705500         42.82             ---      56.00       13.18     L1        10.3
                                    1.069500            ---         22.79       46.00       23.21     L1        10.3
                                    1.069500         41.47             ---      56.00       14.53     L1        10.3


Remark:
Level=Reading Level + Correction Factor
Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                              TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 10 of 27
                                      Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                  District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Conducted Emission
 Product Type                :     Microwave sensor for Ceiling light
 M/N                         :     LM57176
 Operating Condition         :     Normal working with transmitting
 Test specification          :     Negative
 Comment                     :     AC 120V/60Hz (Powered by Ceiling Light)
             Level in dBµV




                                 Frequency      QuasiPeak        Average       Limit      Margin      Line     Corr.
                                   (MHz)         (dBµV)           (dBµV)      (dBµV)       (dB)                (dB)
                                    0.153500            ---         27.61       55.81       28.20     N         10.3
                                    0.153500         52.18             ---      65.81       13.63     N         10.3
                                    0.201500            ---         32.65       53.55       20.90     N         10.2
                                    0.201500         51.41             ---      63.55       12.14     N         10.2
                                    0.273500            ---         24.36       51.01       26.65     N         10.2
                                    0.273500         45.09             ---      61.01       15.92     N         10.2
                                    0.485500            ---         24.60       46.24       21.64     N         10.3
                                    0.485500         42.12             ---      56.24       14.12     N         10.3
                                    0.713500            ---         21.47       46.00       24.53     N         10.3
                                    0.713500         43.42             ---      56.00       12.58     N         10.3
                                    1.077500            ---         23.41       46.00       22.59     N         10.3
                                    1.077500         41.49             ---      56.00       14.51     N         10.3


Remark:
Level=Reading Level + Correction Factor
Correction Factor=Cable Loss + LISN Factor
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                              TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 11 of 27
                                      Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                  District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 8.2 Field strength of emissions and Restricted bands
Test Method

   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3-meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical
   polarizations of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:

   For Above 1GHz
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
      measurement, Sweep = auto, Detector function = peak, Trace = max hold.

   For Below 1GHz
   Use the following spectrum analyzer settings:
      Span = wide enough to capture the peak level of the in-band emission and all spurious
      RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function
      = peak, Trace = max hold.

Note:
        1: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
        120 KHz for Quasi-peak detection (QP) at frequency below 1GHz.
        2: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for peak detection (PK) at frequency above 1GHz.
        3: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 3MHz for RMS Average ((duty cycle ˂ 98%) for Average detection (AV) at
        frequency above 1GHz, then the measurement results was added to a correction factor
        (20log (1/duty cycle)).
        4: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video
        bandwidth is 10Hz (duty cycle ˃ 98%) for Average detection (AV) at frequency above
        1GHz.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 12 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Field strength of emissions and Restricted bands

Limits
According to §15.249 (a) & RSS-210 A2.9(a) , the field strength of emissions from intentional
radiators operated within these frequency bands shall comply with the following:

                                   Field strength of fundamental Field strength of harmonics
   Fundamental frequency
                                   (millivolts/meter)            (microvolts/meter)
   902–928 MHz                     50                                                 500
   2400–2483.5 MHz                 50                                                 500
   5725–5875 MHz                   50                                                 500
   24.0–24.25 GHz                  250                                                2500

According to §15.249 (c)& RSS-210 B.10, Field strength limits are specified at a distance of 3
meters.
According to §15.249 (d)& RSS-210 B.10, Emissions radiated outside of the specified
frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level
of the fundamental or to the general radiated emission limits in §15.209& RSS-Gen, whichever
is the lesser attenuation.
According to §15.205 and RSS-GEN 8.10 Unwanted emissions falling into restricted bands in
§15.205 (a) and RSS-GEN 8.10 Table 7 shall comply with the limits specified in §15.209 and
RSS-Gen.

            Frequency               Field Strength                  Field Strength                        Detector
               MHz                       uV/m                          dBμV/m
              30-88                       100                             40                                  QP
              88-216                      150                            43.5                                 QP
             216-960                      200                             46                                  QP
             960-1000                     500                             54                                  QP
            Above 1000                    500                             54                                  AV
            Above 1000                   5000                             74                                  PK




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 13 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Field strength of emissions and Restricted bands

According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit, it is
unnecessary to perform an average measurement, so AV emission value did not show in
below table if the peak value complies with average limit.

EUT: Microwave sensor for Ceiling light
M/N: LM57176
Operating Condition: Tx; 5734MHz

For Peak Value
                                                                Radiated Emission
             Emissions                             Reading          Correction          PK
                                  E-Field           Level            Factor           Emission
                                                                                                        Limit             Margin       Emission
  Value     Frequency
                                  Polarity         dBµV/m               dB            dBµV/m           dBµV/m              dBm          Type
               MHz
 For Below 1GHz
   PK         943.255000               H             52.50             -15.3            37.20             46.00            8.80         Spurious
   PK         943.147222               V             51.37             -15.3            36.07             46.00            9.93         Spurious
 For Above 1GHz
   PK         1274.687500              H             46.97             -12.0            34.97            74.00            39.03         Spurious
   PK         1252.750000              V             44.88             -12.1            32.78            74.00            41.22         Spurious
   PK         5734.000000              H             68.42               3.8            72.22           114.00            41.78       Fundamental
   PK         5734.000000              V             70.36               3.8            74.16           114.00            39.84       Fundamental
   PK        17617.062500              H             28.24              21.2            49.44            74.00            24.56         Spurious
   PK       17801.656250*              V             27.59              21.3            48.89            74.00            25.11         Spurious


For AV Value
                                                             Radiated Emission
                                         Reading                       AV
           Emissions                                  Correction                   Average         AV
                           E-Field        Level
                                                       Factor
                                                                     Reading
                                                                                                 Emission
                                                                                                               Limit         Margin      Emission
Value      Frequency                                                  Level         Factor
                           Polarity     dBµV/m                                                                dBµV/m          dBm         Type
              MHz                                         dB                         dB          dBµV/m
                                                                     dBµV/m
  AV       5734.000000        H            67.82          3.8             /            0          71.62           94.00       22.38     Fundamental
  AV       5734.000000        V            70.12          3.8             /            0          73.92           94.00       20.08     Fundamental
  AV            /             H                                           /            0                          54.00         /         Spurious
  AV            /             V                                           /            0                          54.00         /         Spurious
Average Factor=10log(dutycycle), dutycycle=100%

Remark:
1: Data of measurement within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than
   20db below the permissible limits or the field strength is too small to be measured.
2: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.
3: AV Emission Level= AV Reading Level+10log(1/dutycycle)
4: PK Emission = Reading Level + Correction Factor
AV Emission = Reading Level + Correction Factor
Correction Factor=Antenna Factor + Cable Loss (For Below 1GHz)
Correction Factor = Antenna Factor + Cable Loss- Amplifier Gain (For Above 1GHz)
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                               TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 27
                                       Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                   District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Field strength of emissions and Restricted bands


EUT: Microwave sensor for Ceiling light
M/N: LM57176
Operating Condition: Tx; 5795MHz

For Peak Value
                                                                  Radiated Emission
                 Emissions                           Reading          Correction          PK
                                    E-Field           Level            Factor           Emission
                                                                                                          Limit            Margin       Emission
  Value          Frequency
                                    Polarity         dBµV/m               dB            dBµV/m           dBµV/m             dBm          Type
                    MHz
 For Above 1GHz
   PK        1271.875000                 H             47.71             -12.0            35.71            74.00           38.29         Spurious
   PK        1254.062500                 V             44.67             -12.0            32.67            74.00           41.33         Spurious
   PK        5795.000000                 H             74.33               3.6            77.93           114.00           36.07       Fundamental
   PK        5795.000000                 V             76.27               3.6            79.87           114.00           34.13       Fundamental
   PK       11589.062500*                H             41.03               8.7            49.73            74.00           24.27         Spurious
   PK       17903.406250*                V             27.76              21.5            49.26            74.00           24.74         Spurious


For AV Value
                                                               Radiated Emission
                                           Reading                       AV
           Emissions                                    Correction                   Average         AV
                             E-Field        Level
                                                         Factor
                                                                       Reading
                                                                                                   Emission
                                                                                                                 Limit        Margin      Emission
Value      Frequency                                                    Level         Factor
                             Polarity     dBµV/m                                                                dBµV/m         dBm         Type
              MHz                                           dB                         dB          dBµV/m
                                                                       dBµV/m
  AV       5795.000000          H            73.85          3.6             /            0          77.45          94.00       16.55     Fundamental
  AV       5795.000000          V            75.93          3.6             /            0          79.53          94.00       14.47     Fundamental
  AV            /               H                                           /            0                         54.00         /         Spurious
  AV            /               V                                           /            0                         54.00         /         Spurious
Average Factor=10log(dutycycle), dutycycle=100%

Remark:
1: Data of measurement within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than
   20db below the permissible limits or the field strength is too small to be measured.
2: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.
3: AV Emission Level= AV Reading Level+10log(1/dutycycle)
4: PK Emission = Reading Level + Correction Factor
AV Emission = Reading Level + Correction Factor
Correction Factor=Antenna Factor + Cable Loss (For Below 1GHz)
Correction Factor = Antenna Factor + Cable Loss- Amplifier Gain (For Above 1GHz)
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                                 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch               Page 15 of 27
                                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                     District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Field strength of emissions and Restricted bands

EUT: Microwave sensor for Ceiling light
M/N: LM57176
Operating Condition: Tx; 5858MHz

For Peak Value
                                                                  Radiated Emission
                 Emissions                           Reading          Correction          PK
                                    E-Field           Level            Factor           Emission
                                                                                                          Limit            Margin       Emission
  Value          Frequency
                                    Polarity         dBµV/m               dB            dBµV/m           dBµV/m             dBm          Type
                    MHz
 For Above 1GHz
   PK         1263.250000                H             46.41             -12.0            34.41            74.00           39.59         Spurious
   PK         1251.812500                V             43.61             -12.1            31.51            74.00           42.49         Spurious
   PK         5858.000000                H             53.94               3.3            57.24           114.00           16.76       Fundamental
   PK         5858.000000                V             66.56               3.3            69.86           114.00            4.14       Fundamental
   PK        17671.031250                H             27.77              21.3            49.07            74.00           24.93         Spurious
   PK       17772.093750*                V             27.83              21.3            49.13            74.00           24.87         Spurious


For AV Value
                                                               Radiated Emission
                                           Reading                       AV
           Emissions                                    Correction                   Average         AV
                             E-Field        Level
                                                         Factor
                                                                       Reading
                                                                                                   Emission
                                                                                                                 Limit        Margin      Emission
Value      Frequency                                                    Level         Factor
                             Polarity     dBµV/m                                                                dBµV/m         dBm         Type
              MHz                                           dB                         dB          dBµV/m
                                                                       dBµV/m
  AV       5858.000000          H            53.94          3.3             /            0          57.24          94.00       36.76     Fundamental
  AV       5858.000000          V            66.56          3.3             /            0          69.86          94.00       24.14     Fundamental
  AV            /               H                                           /            0                         54.00         /         Spurious
  AV            /               V                                           /            0                         54.00         /         Spurious
Average Factor=10log(dutycycle), dutycycle=100%

Remark:
1: Data of measurement within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than
   20db below the permissible limits or the field strength is too small to be measured.
2: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.
3: AV Emission Level= AV Reading Level+10log(1/dutycycle)
4: PK Emission = Reading Level + Correction Factor
AV Emission = Reading Level + Correction Factor
Correction Factor=Antenna Factor + Cable Loss (For Below 1GHz)
Correction Factor = Antenna Factor + Cable Loss- Amplifier Gain (For Above 1GHz)
(The Reading Level is recorded by software which is not shown in the sheet)




 EMC_SZ_FR_23.00 FCC                                 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch               Page 16 of 27
                                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                     District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 8.3 Out of Band Emissions
Test Method

   1 Use the following spectrum analyzer settings:
     Span = wide enough to capture the peak level of the in-band emission and all spurious
     RBW = 100 kHz, VBW≥RBW, Sweep = auto, Detector function = peak, Trace = max
     hold.
   2 Allow the trace to stabilize, use the peak and delta measurement to record the result.
   3 The level displayed must comply with the limit specified in this Section.


Limits
According to §15.249(d) & RSS-210 B.10 Emissions radiated outside of the specified
frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level
of the fundamental or to the general radiated emission limits in §15.209 and RSS-Gen,
whichever is the lesser attenuation.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 17 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Out of Band Emissions

EUT: Microwave sensor for Ceiling light
M/N: LM57176
Operating Condition: Tx; 5734MHz
Polarization: Horizontal
          Level in dBµV/m




                      Frequency   MaxPeak      Limit    Margin      Meas.      Bandwidth        Height     Pol    Azimuth          Corr.
                        (MHz)     (dBµV/m)    (dBµV      (dB)       Time         (kHz)           (cm)              (deg)           (dB)
                                                /m)                 (ms)
                  5725.150000        34.56     74.00       39.44       ---                ---    154.0     H          171.0          3.8
                  5734.593750        75.07     74.00       -1.07       ---                ---    154.0     H          207.0          3.8
                  5750.231250        32.98     74.00       41.02       ---                ---    154.0     H            0.0          3.7




 EMC_SZ_FR_23.00 FCC                              TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 18 of 27
                                      Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                  District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Out of Band Emissions

EUT: Microwave sensor for Ceiling light
M/N: LM57176
Operating Condition: Tx; 5734MHz
Polarization: Vertical
          Level in dBµV/m




                      Frequency   MaxPeak      Limit    Margin      Meas.      Bandwidth        Height     Pol    Azimuth          Corr.
                        (MHz)     (dBµV/m)    (dBµV      (dB)       Time         (kHz)           (cm)              (deg)           (dB)
                                                /m)                 (ms)
                  5725.250000        34.57     74.00       39.43       ---                ---    154.0     V          340.0          3.8
                  5735.137500        72.97     74.00        1.03       ---                ---    154.0     V          300.0          3.8
                  5750.312500        33.93     74.00       40.07       ---                ---    154.0     V           10.0          3.7




 EMC_SZ_FR_23.00 FCC                              TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 19 of 27
                                      Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                  District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Out of Band Emissions

EUT: Microwave sensor for Ceiling light
M/N: LM57176
Operating Condition: Tx; 5858MHz
Polarization: Horizontal
          Level in dBµV/m




                      Frequency   MaxPeak      Limit    Margin      Meas.      Bandwidth        Height     Pol    Azimuth          Corr.
                        (MHz)     (dBµV/m)    (dBµV      (dB)       Time         (kHz)           (cm)              (deg)           (dB)
                                                /m)                 (ms)
                  5859.125000        56.31     74.00       17.69       ---                ---    154.0     H          204.0          3.3
                  5877.250000        34.73     74.00       39.27       ---                ---    154.0     H          160.0          3.3
                  5950.418750        32.76     74.00       41.24       ---                ---    154.0     H           94.0          3.2




 EMC_SZ_FR_23.00 FCC                              TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 20 of 27
                                      Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                  District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 Out of Band Emissions

EUT: Microwave sensor for Ceiling light
M/N: LM57176
Operating Condition: Tx; 5858MHz
Polarization: Vertical
          Level in dBµV/m




                      Frequency   MaxPeak      Limit    Margin      Meas.      Bandwidth        Height     Pol    Azimuth          Corr.
                        (MHz)     (dBµV/m)    (dBµV      (dB)       Time         (kHz)           (cm)              (deg)           (dB)
                                                /m)                 (ms)
                  5860.837500        69.26     74.00        4.74       ---                ---    154.0     V            4.0          3.3
                  5877.025000        34.54     74.00       39.46       ---                ---    154.0     V           15.0          3.3
                  5950.631250        33.42     74.00       40.58       ---                ---    154.0     V          353.0          3.2




 EMC_SZ_FR_23.00 FCC                              TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 21 of 27
                                      Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20                  District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 8.4 20dB Bandwidth & 99% Occupied Bandwidth
Test Method
1.    Check the calibration of the measuring instrument using either an internal calibrator or a
      known signal from an external generator.
2.     Position the EUT without connection to measurement instrument. Turn on the EUT and
      connect it to measurement instrument. Then set it to any one convenient frequency
      within its operating range. Set a reference level on the measuring instrument equal to
      the highest peak value.
3.    Measure the frequency difference of two frequencies that were attenuated 20 dB from
      the reference level. Record the frequency difference as the emission bandwidth.

Limits:
According to 15.215 (c) Intentional radiators operating under the alternative provisions to the
general emission limits, as contained in §§ 15.217 through 15.257 and in Subpart E of this
part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever
bandwidth may otherwise be specified in the specific rule section under which the equipment
operates, is contained within the frequency band designated in the rule section under which
the equipment is operated. The requirement to contain the designated bandwidth of the
emission within the specified frequency band includes the effects from frequency sweeping,
frequency hopping and other modulation techniques that may be employed as well as the
frequency stability of the transmitter over expected variations in temperature and supply
voltage. If a frequency stability is not specified in the regulations, it is recommended that the
fundamental emission be kept within at least the central 80% of the permitted band in order to
minimize the possibility of out-of-band operation.

According to RSS-Gen 6.7 when an occupied bandwidth value is not specified in the
applicable RSS, the transmitted signal bandwidth to be reported is to be its 99% emission
bandwidth, as calculated or measured.




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 22 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 20dB Bandwidth & 99% Occupied Bandwidth

                 Frequency                  20dB Bandwidth                         99% Bandwidth                   Limit
                    MHz                          KHz                                    kHz                        kHz
                    5734                        294.21                                 268.11                        --




                                                        5734MHz




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 23 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 20dB Bandwidth & 99% Occupied Bandwidth

                 Frequency                  20dB Bandwidth                         99% Bandwidth                   Limit
                    MHz                          KHz                                    kHz                        kHz
                    5795                        306.08                                 265.77                        --




                                                        5795MHz




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 24 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 20dB Bandwidth & 99% Occupied Bandwidth

                 Frequency                  20dB Bandwidth                         99% Bandwidth                   Limit
                    MHz                          KHz                                    kHz                        kHz
                    5858                        412.96                                 432.01                        --




                                                        5858MHz




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 25 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 9 Test equipment lists

                                         List of Test Instruments

Radiated Emission Test
  DESCRIPTION        MANUFACTURER                MODEL NO.             EQUIPMENT ID                SERIAL NO.             CAL. DUE
                                                                                                                            DATE
 EMI Test Receiver    Rohde & Schwarz               ESR 26             68-4-74-14-002                  101269             2020-6-28
  Horn Antenna        Rohde & Schwarz               HF907              68-4-80-14-005                  102294             2020-6-22
   Loop Antenna       Rohde & Schwarz              HFH2-Z2             68-4-80-14-006                100398                2020-7-7
    Pre-amplifier     Rohde & Schwarz              SCU 18              68-4-29-14-001                102230               2020-6-28
  Signal Generator    Rohde & Schwarz               SMY01              68-4-48-16-001              839369/005             2020-6-28
     Attenuator           Agilent                   8491A              68-4-81-16-001              MY39264334             2020-6-28
 3m Semi-anechoic
                            TDK                      9X6X6             68-4-90-14-001                     ----            2020-7-7
      chamber
                                                                       68-4-90-14-001-
   Test software      Rohde & Schwarz               EMC32                                         Version9.15.00             N/A
                                                                             A10

Conducted Emission Test
  DESCRIPTION        MANUFACTURER                MODEL NO.             EQUIPMENT ID                SERIAL NO.             CAL. DUE
                                                                                                                            DATE
 EMI Test Receiver    Rohde & Schwarz               ESR 3              68-4-74-14-001                  101782             2020-6-28
       LISN           Rohde & Schwarz              ENV4200              8-4-87-14-001                  100249             2020-6-28
       LISN           Rohde & Schwarz              ENV432              68-4-87-16-001                  101318             2020-7-19
       LISN           Rohde & Schwarz              ENV216              68-4-87-14-002                  100326             2020-6-28
       ISN            Rohde & Schwarz              ENY81               68-4-87-14-003                  100177             2020-6-28
       ISN            Rohde & Schwarz            ENY81-CA6             68-4-87-14-004                  101664             2020-6-28
                                                 TK9420(VT9
High Voltage Probe    Rohde & Schwarz                                  68-4-27-14-001                 9420-584            2020-6-24
                                                     420)
 RF Current Probe     Rohde & Schwarz               EZ-17              68-4-27-14-002                 100816               2020-7-2
    Attenuator       Shanghai Huaxiang            TS2-26-3             68-4-81-16-003               080928189             2020-6-28
                                                                       68-4-90-14-003-
   Test software      Rohde & Schwarz               EMC32                                         Version9.15.00             N/A
                                                                             A10




 EMC_SZ_FR_23.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 26 of 27
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20       District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.940.19.0030.01




 10 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in accordance
with the recommendations of ISO 17025 were:

                                          System Measurement Uncertainty
                                    Test Items                                                          Extended Uncertainty
                                                                                                         Horizontal: 4.91dB;
  Uncertainty for Radiated Emission in 3m chamber 30MHz-1000MHz
                                                                                                          Vertical: 4.89dB;
                                                                                                         Horizontal: 4.80dB;
  Uncertainty for Radiated Spurious Emission 25MHz-3000MHz
                                                                                                          Vertical: 4.87dB;
                                                                                                         Horizontal: 4.59dB;
  Uncertainty for Radiated Spurious Emission 3000MHz-18000MHz
                                                                                                          Vertical: 4.58dB;
                                                                                                         Horizontal: 5.05dB;
  Uncertainty for Radiated Spurious Emission 18000MHz-40000MHz
                                                                                                          Vertical: 5.04dB;
  Uncertainty for Conducted Emission 150kHz-30MHz (for test using AMN ENV432                                   3.21dB
  or ENV4200)




 EMC_SZ_FR_23.00 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch              Page 27 of 27
                              Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan
 Release 2014-03-20          District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-08-28 09:51:53
Document Modified: 2019-08-28 09:51:53

© 2024 FCC.report