RF Exposure Info

FCC ID: WUI-LM57176

RF Exposure Info

Download: PDF
FCCID_4415320

Report Number: 68.940.19.0030.01A




                                                       RF exposure Estimation

           Introduction
           LM57176 (FCC ID: WUI-LM57176) is a Microwave sensor for Ceiling light, which contain
           5.8GHz microwave function inside.

1.         Limit and Guidelines on Exposure to Electromagnetic Fields
           According to §1.1307(b)(1), systems operating under the provisions of this section shall be
           operated in a manner that ensure that the public is not exposed to radio frequency energy level
           in excess of the Commission’s guideline.

           According to KDB 447498 D01 General RF Exposure Guidance v06, Mobile Portable RF
           Exposure, no SAR required if power is lower than the flowing threshold:
           The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
           distances ≤ 50 mm are determined by:
            [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]
            [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
                • f(GHz) is the RF channel transmit frequency in GHz
                • Power and distance are rounded to the nearest mW and mm before calculation25
                • The result is rounded to one decimal place for comparison
                • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

           The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
           and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test
           separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to
           determine SAR test exclusion.

2.         Calculation method

           [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance,
           mm)] ·[√f(GHz)] ≤ 3.0

           According to ANSI C63.10-2013 (9.5 Equations to calculate EIRP),




                                               TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755
                                                                           8828 5299


Report Number: 68.940.19.0030.01A




         Field Strength (EMeas):                                                                                                 79.87 (dBuV/m)
                                                                                                                                 (f=5795MHz)
         Measurement Distance(dMeas):                                                                                            3 (m)
         Equivalent Isotropically Radiated Power(EIRP):                                                                          0.03 (mW)



           Radiated Power + tune up tolerance = 0.03mW
           Distance = 5 mm
           f = 5.795 GHz

           [0.03/5] * SQRT(5.795) =0.1281
           0.014 ≤ 3.0
           Therefore, excluded from SAR testing.


TUV SUD China, Shenzhen Branch

Reviewed by:                                                                                 Prepared By:




Laurent Yuan/ EMC Project Manager                                                        Henry Chen/EMC Project Engineer

Date: 2019-08-14                                                                                Date: 2019-08-14




                                               TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755
                                                                           8828 5299



Document Created: 2019-08-22 12:09:15
Document Modified: 2019-08-22 12:09:15

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC