Test Report

FCC ID: WQJ-KIOSKIV

Test Report

Download: PDF
FCCID_3863756

                                     FCC 47 CFR PART 15 SUBPART C
                                          ISED Canada RSS-210

                                       CERTIFICATION TEST REPORT


                                                            For

                                           Contactless Card Reader

                                   MODEL NUMBER: ViVOpay Kiosk IV

                                             FCC ID: WQJ-KIOSKIV

                                                IC: 9847A-KIOSKIV

                                    REPORT NUMBER: 4788418265-1-1

                                          ISSUE DATE: May 15, 2018



                                                      Prepared for

                                               ID TECH
                                10721 Walker Street, Cypress, CA. 90630



                                                      Prepared by

         UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
                   Room 101, Building 10, Innovation Technology Park,
         Song Shan Lake Hi tech Development Zone, Dongguan, 523808, China
                                  Tel: +86 769 33871725
                                  Fax: +86 769 33871725
                                  Website: www.ul.com




The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report
shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the
test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to
other similar products. This report does not imply that the product(s) has met the criteria for certification.


                                                                                REPORT NO.: 4788418265-1-1
                                                                                              Page 2 of 32

                                                  Revision History

            Issue Date
Rev.                              Revisions                                                            Revised By
 --         05/15/2018            Initial Issue




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                     FORM NO: 10-SL-F0035
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                           .


                                                                             REPORT NO.: 4788418265-1-1
                                                                                           Page 3 of 32

                                        Summary of Test Results
Clause                     Test Items                                 FCC Rules                   Test Results
                Transmitter AC Conducted                            Part 15.207
  1                                                                                                   PASS
                       Emissions                                   RSS-Gen 8.8
                                                              Part 15.225(a)(b)(c)(d)
  2           Transmitter Fundamental Field                  RSS-Gen 6.12/RSS-210                     PASS
                         Strength                                       B.6
                                                             Part 15.209(a)/ 15.225(d)
  3           Transmitter Radiated Emissions                 RSS-Gen 6.13/RSS-210                     PASS
                                                                        B.6
                                                                  Part 15.209(a)/
             Transmitter Band Edge Radiated                         15.225(c)(d)
  5                                                                                                   PASS
                        Emissions                            RSS-Gen 6.13/ RSS-210
                                                                        B.6
                Transmitter 99% Emission                           RSS-Gen 6.6/
  6                                                                                                   PASS
               Bandwidth / 20dB Bandwidth                         Part 15.215 (c)
                Transmitter Frequency                            Part 15.225(e)
  7            Stability (Temperature &                      RSS-Gen 6.11/ RSS-210                    PASS
                  Voltage Variation)                                   B.6




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
   This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                        .


                                                                                            REPORT NO.: 4788418265-1-1
                                                                                                          Page 4 of 32
                                              TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS .................................................................................... 5

2.     TEST METHODOLOGY ........................................................................................................ 6

3.     FACILITIES AND ACCREDITATION .................................................................................... 6

4.     CALIBRATION AND UNCERTAINTY .................................................................................. 7
     4.1.    MEASURING INSTRUMENT CALIBRATION ................................................................ 7
     4.2.    MEASUREMENT UNCERTAINTY ................................................................................. 7

5.     EQUIPMENT UNDER TEST ................................................................................................. 8
     5.1.    DESCRIPTION OF EUT ................................................................................................. 8
     5.2.    MAXIMUM OUTPUT POWER ........................................................................................ 8
     5.3.    CHANNEL LIST .............................................................................................................. 8
     5.4.    DESCRIPTION OF AVAILABLE ANTENNAS ................................................................ 9
     5.5.    TEST ENVIRONMENT ................................................................................................... 9
     5.6.    DESCRIPTION OF TEST SETUP ................................................................................ 10
     5.7.    MEASURING INSTRUMENT AND SOFTWARE USED .............................................. 11

6.     ANTENNA PORT TEST RESULTS .................................................................................... 12
     6.1.    AC Conducted Spurious Emissions .............................................................................. 12
     6.2. RADIATED EMISSION ................................................................................................. 15
       6.2.1. FUNDAMENTAL FIELD STRENGTH.................................................................... 20
       6.2.2. SPURIOUS EMISSIONS BELOW 1G ................................................................... 22
       6.2.3. SPURIOUS EMISSIONS BELOW 30M ................................................................. 24
     6.3.    99%/20dB BANDWIDTH .............................................................................................. 28
     6.4.    TRANSMITTER FREQUENCY STABILITY ................................................................. 30

7.     ANTENNA REQUIREMENTS ............................................................................................. 32




     UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                             FORM NO: 10-SL-F0035
         This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                      (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                                    .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 5 of 32

1. ATTESTATION OF TEST RESULTS
Applicant Information
Company Name:                         ID TECH

Address:                              10721 Walker Street, Cypress, CA. 90630

Manufacturer Information
Company Name:                         ID TECH

Address:                              10721 Walker Street, Cypress, CA. 90630


EUT Name:                             Contactless Card Reader
Model:                                ViVOpay Kiosk IV
Brand Name:                           /
Sample Status:                        Normal
Sample ID:                            1509908
Sample Received Date:                 March 29, 2018
Date of Tested:                       April 09, 2018 ~May 14, 2018

                                        APPLICABLE STANDARDS
                                STANDARD                                             TEST RESULTS
                       CFR 47 Part 15 Subpart C                                             PASS
                         ISED Canada RSS-210                                                PASS

Tested By:                                                      Checked By:




Kebo Zhang                                                     Shawn Wen
Engineer                                                       Laboratory Leader
Approved By:




Stephen Guo
Laboratory Manager




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 6 of 32

2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.10-2013,
FCC CFR 47 Part 2, FCC CFR 47 Part 15 and KDB414788 D01 Radiated Test Site v01.



3. FACILITIES AND ACCREDITATION
                        A2LA (Certificate No.: 4102.01)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with A2LA.
                        IAS (Lab Code: TL-702)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has demonstrated compliance with ISO/IEC Standard 17025:2005,
                        General requirements for the competence of testing and calibration
                        laboratories
                        FCC (FCC Designation No.: CN1187)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        Has been recognized to perform compliance testing on equipment subject
Accreditation           to the Commission's Delcaration of Conformity (DoC) and Certification
Certificate             rules
                        IC(Company No.: 21320)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been registered and fully described in a report filed with ISED. The
                        Company Number is 21320.
                        VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011)
                        UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                        has been assessed and proved to be in compliance with VCCI, the
                        Membership No. is 3793.
                        Facility Name:
                        Chamber D, the VCCI registration No. is G-20019 and R-20004
                        Shielding Room B , the VCCI registration No. is C-20012 and T-20011

Note 1: All tests measurement facilities use to collect the measurement data are located at
Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone,
Dongguan, 523808, China

Note 2: The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd.
Song Shan Lake Branch had been calibrated and compared to the open field sites and the test
anechoic chamber is shown to be equivalent to or worst case from the open field site.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 7 of 32


4. CALIBRATION AND UNCERTAINTY
       4.1.     MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognize national standards.


       4.2.     MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:

                          Test Item                                               Uncertainty
      Uncertainty for Conduction emission test                                       2.90dB
   Uncertainty for Radiation Emission test(include
              Fundamental emission)                                                   2.2dB
                   (9KHz-30MHz)
   Uncertainty for Radiation Emission test(include
              Fundamental emission)                                                  4.52dB
                   (30MHz-1GHz)
       Uncertainty for Radiation Emission test                                 5.04dB(1-6GHz)
      (1GHz to 26GHz)( include Fundamental                                  5.30dB (6GHz-18Gz)
                      emission)
                                                            5.23dB (18GHz-26Gz)
   Note: This uncertainty represents an expanded uncertainty expressed at approximately
   the 95% confidence level using a coverage factor of k=2.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                                REPORT NO.: 4788418265-1-1
                                                                                              Page 8 of 32

5. EQUIPMENT UNDER TEST

        5.1.     DESCRIPTION OF EUT
Equipment                       Contactless Card Reader
Model Name                      ViVOpay Kiosk IV
P/N                    IDVK-410, IDVK-411
                       They are the same but IDVK-411 has 4 screws when IDVK-410
Difference between the
                       doesn’t have. For more information, please refer to the external
two P/N
                       photo.
Operation frequency    13.56 MHz
Modulation Technique            ASK
Rated Input Power               DC 5V
Hardware Version                Rev.A
Software Version                V1.20




        5.2.     MAXIMUM OUTPUT POWER
                       Number of Transmit
 Frequency                                               Frequency                                    Max Power
                           Chains                                           Channel Number
   (MHz)                                                   (MHz)                                      (dBµV/m)
                            (NTX)
      13.56                    1                               13.56                  1                   50.34



        5.3.     CHANNEL LIST
               Frequency                     Frequency                     Frequency                      Frequency
Channel                        Channel                          Channel                     Channel
                 (MHz)                         (MHz)                         (MHz)                          (MHz)
   1             13.56




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                     FORM NO: 10-SL-F0035
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                           .


                                                                              REPORT NO.: 4788418265-1-1
                                                                                            Page 9 of 32

      5.4.      DESCRIPTION OF AVAILABLE ANTENNAS
      Ant.                  Frequency (MHz)                   Antenna Type                Antenna Gain (dBi)
        1                          13.56                     FPCB Antenna                            0

                                Transmit and
   Frequency (MHz)                                                            Description
                                Receive Mode
                                                        Chain 1 can be used as transmitting/receiving
         13.56                      1TX, 1RX
                                                                         antenna.




      5.5.      TEST ENVIRONMENT
  Environment Parameter                                      Selected Values During Tests
     Relative Humidity                                                   55 ~ 65%
   Atmospheric Pressure:                                                  1025Pa
       Temperature                                    TL                                       -25 °C
                                                      TN                                    23 ~ 28 °C
                                                      TH                                       70 °C
                                                      VL                                      AC 102V
            Voltage :                                 VN                                     AC 120V
                                                      VH                                     AC 138V

Note: VL= Lower Extreme Test Voltage
      VN= Nominal Voltage
      VH= Upper Extreme Test Voltage
      TN= Normal Temperature




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
    This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                 (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                         .


                                                                                 REPORT NO.: 4788418265-1-1
                                                                                               Page 10 of 32

          5.6.    DESCRIPTION OF TEST SETUP
SUPPORT EQUIPMENT


Item             Equipment              Brand Name              Model Name                          P/N
  1               Laptop                  ThinkPad                 T460S                      SL10K24796 JS
  2              Test Card                     N/A                      N/A                         N/A


I/O PORT


 Cable No             Port          Connector Type           Cable Type         Cable Length(m)            Remarks
      1           USB Port                     /                    /                     /                     /


ACCESSORY


Item        Accessory            Brand Name          Model Name                          Description
                                                      DSC-6PFA-          Input: AC 100~240V, 50~60Hz, 0.2A
  1       Power Adapter               DVE
                                                      05 050100          Output: DC 5V/1A



TEST SETUP

The EUT can continue work normally when a card touched.


SETUP DIAGRAM FOR TESTS




                                               EUT          Test
                                                            Card


                                    DC Cable



                                             Power
                                            Adapter




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                     FORM NO: 10-SL-F0035
       This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                    (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                            .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 11 of 32

       5.7.     MEASURING INSTRUMENT AND SOFTWARE USED
                                             Conducted Emissions
Used        Equipment            Manufacturer         Model No.        Serial No.       Last Cal.         Next Cal.
      EMI Test Receiver    R&S         ESR3       101961 Dec.12, 2017 Dec.11, 2018
         Two-Line V-
                           R&S        ENV216     101983 Dec.12, 2017 Dec.11, 2018
            Network
        Artificial Mains
                        Schwarzbeck NSLK 8126 8126465 Dec.12, 2017 Dec.11, 2018
           Networks
                                 Radiated Emissions
Used        Equipment            Manufacturer         Model No.        Serial No.   Last Cal.   Next Cal.
                                                                       MY56400
      MXE EMI Receiver            KESIGHT              N9038A                    Dec.12, 2017 Dec.11, 2018
                                                                         036
       Hybrid Log Periodic
                                      TDK           HLP-3003C          130960       Dec.12, 2017 Dec.11, 2018
            Antenna
                                                                       2944A090
          Preamplifier                 HP               8447D                  Dec.12, 2017 Dec.11, 2018
                                                                          99
       EMI Measurement
                                      R&S              ESR26           101377       Dec.12, 2017 Dec.11, 2018
           Receiver
                                                                       TRS-305-
          Preamplifier                TDK           PA-02-0118                 Dec.12, 2017 Dec.11, 2018
                                                                        00066
                                                                       TRS-307-
          Preamplifier                TDK              PA-02-2                 Dec.12, 2017 Dec.11, 2018
                                                                        00003
         Loop antenna           Schwarzbeck             1519B          00008 Mar. 26, 2016 Mar. 26, 2019
                                                      Software
Used                    Description                       Manufacturer                Name                  Version
      Test Software for Radiated disturbance                  Farad                EZ-EMC              Ver. UL-3A1




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                   FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 12 of 32

6. ANTENNA PORT TEST RESULTS

         6.1.   AC Conducted Spurious Emissions
LIMITS


FCC Reference:                             Part 15.207
ISED Canada Reference:                     RSS-Gen 8.8
Test Method Used:                          ANSI C63.10 Section 6.2 / FCC KDB 174176


   FREQUENCY                   Class A (dBuV)                                   Class B (dBuV)
      (MHz)                Quasi-peak     Average                    Quasi-peak             Average
      0.15 -0.5              79.00         66.00                      66 - 56 *             56 - 46 *
      0.50 -5.0              73.00         60.00                       56.00                 46.00
      5.0 -30.0              73.00         60.00                       60.00                 50.00


TEST SETUP AND PROCEDURE




                                80cm                          ≥80cm
         40cm
                                                                              Receiver
                  EUT

         80cm
                                                 LISN




The EUT is put on a table of non-conducting material that is 80cm high. The vertical conducting
wall of shielding is located 40cm to the rear of the EUT. The power line of the EUT is connected
to the AC mains through a Artificial Mains Network (A.M.N.). A EMI Measurement Receiver
(R&S Test Receiver ESR3) is used to test the emissions from both sides of AC line. According
to the requirements in Section 6.2 of ANSI C63.10-2003.Conducted emissions from the EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-Peak and
average detector mode. The bandwidth of EMI test receiver is set at 9kHz.
The arrangement of the equipment is installed to meet the standards and operating in a manner,
which tends to maximize its emission characteristics in a normal application.



  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                                  REPORT NO.: 4788418265-1-1
                                                                                                Page 13 of 32


 TEST ENVIRONMENT

 Temperature                      24.2°C                                  Relative Humidity        62%
 Atmosphere Pressure              101kPa                                  Test Voltage             AC 120V60Hz

                             LINE N RESULTS (WORST-CASE CONFIGURATION)




  No.       Frequency          Reading         Correct           Result       Limit        Margin           Remark
              (MHz)            (dBuV)            dB              (dBuV)      (dBuV)         (dB)
    1         0.1522            28.96           9.64              38.60       65.88        -27.28               QP
    2         0.1522             9.39           9.64              19.03       55.88        -36.85              AVG
    3         0.1677            28.32           9.63              37.95       65.07        -27.12               QP
    4         0.1677             8.67           9.63              18.30       55.07        -36.77              AVG
    5         0.2063            25.58           9.63              35.21       63.35        -28.14               QP
    6         0.2063             7.26           9.63              16.89       53.35        -36.46              AVG
    7         0.3763            21.96           9.63              31.59       58.36        -26.77               QP
    8         0.3763            12.29           9.63              21.92       48.36        -26.44              AVG
    9         0.7636             3.27           9.64              12.91       56.00        -43.09               QP
   10         0.7636            -0.77           9.64               8.87       46.00        -37.13              AVG
   11        13.5617            34.02           9.90              43.92       60.00        -16.08               QP
   12        13.5617            22.27           9.90              32.17       50.00        -17.83              AVG

Note: 1. Result = Reading +Correct Factor.
      2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit.
      3. Test setup: RBW: 200 Hz (9 kHz—150 kHz), 9 kHz (150 kHz—30 MHz).
      4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.


   UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                    FORM NO: 10-SL-F0035
        This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                     (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                             .


                                                                                  REPORT NO.: 4788418265-1-1
                                                                                                Page 14 of 32


                             LINE L RESULTS (WORST-CASE CONFIGURATION)




  No.       Frequency          Reading         Correct           Result       Limit        Margin           Remark
              (MHz)            (dBuV)            dB              (dBuV)      (dBuV)         (dB)
    1         0.1597            29.41           9.63              39.04       65.48        -26.44               QP
    2         0.1597            12.04           9.63              21.67       55.48        -33.81              AVG
    3         0.1833            27.50           9.63              37.13       64.33        -27.20               QP
    4         0.1833            12.10           9.63              21.73       54.33        -32.60              AVG
    5         0.2304            22.07           9.63              31.70       62.44        -30.74               QP
    6         0.2304             8.87           9.63              18.50       52.44        -33.94              AVG
    7         0.3765            25.45           9.63              35.08       58.36        -23.28               QP
    8         0.3765            14.70           9.63              24.33       48.36        -24.03              AVG
    9         0.8408            11.33           9.64              20.97       56.00        -35.03               QP
   10         0.8408             2.26           9.64              11.90       46.00        -34.10              AVG
   11        13.5617            29.19           9.90              39.09       60.00        -20.91               QP
   12        13.5617            19.75           9.90              29.65       50.00        -20.35              AVG

Note: 1. Result = Reading +Correct Factor.
      2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit.
      3. Test setup: RBW: 200 Hz (9 kHz—150 kHz), 9 kHz (150 kHz—30 MHz).
      4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.

 Note: For the Transmitter Fundamental, we add the Field Strength test in cause 6.2.




   UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                    FORM NO: 10-SL-F0035
        This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                     (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                             .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 15 of 32


       6.2.     RADIATED EMISSION
TEST PROCEDURE

 Fundamental field strength

FCC Reference:                      Part 15.225(a)(b)(c)(d) & 15.209(a)
ISED Canada Reference:              RSS-Gen 6.13 & RSS-210 B.6
Test Method Used:                   ANSI C63.10 Sections 6.3, 6.4 and 6.5


             Frequency                      Field Strength          Field Strength             Field Strength
               (MHz)                            (uV/m)            (dBuV/m) at 30M             (dBuV/m) at 3M
           13.553-13.567                        15848                     84                       123.90
   13.410-13.553/13.567‑13.710                    334                    50.47                      90.47
   13.110-13.410/13.710‑14.010                    106                    40.51                      80.51


Note(s):
1. The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall
not exceed the general radiated emission limits in §15.209.


2. The limit is specified at a test distance of 30 meters. However, as specified by FCC Section
15.31 (f)(2) / RSS-Gen Section 6.4, measurements may be performed at a closer distance and
the measured level corrected to the specified measurement distance by using the square of an
inverse linear distance extrapolation factor (40dB/decade).




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 16 of 32

Radiation Disturbance Test Limit for FCC (Class B)(9KHz-1GHz)

                Frequency                        Field Strength                Measurement Distance
                    (MHz)                      (microvolts/meter)                    (meters)
               0.009~0.490                        2400/F(KHz)                          300
               0.490~1.705                       24000/F(KHz)                          30
                1.705~30.0                             30                              30
                    30~88                             100                               3
                   88~216                             150                               3
                  216~960                             200                               3
                 960~1000                             500                               3

Note: 1) At frequencies at or above 30 MHz, measurements may be performed at a distance
other than what is specified provided: measurements are not made in the near field except
where it can be shown that near field measurements are appropriate due to the characteristics
of the device; and it can be demonstrated that the signal levels needed to be measured at the
distance employed can be detected by the measurement equipment. Measurements shall not
be performed at a distance greater than 30 meters unless it can be further demonstrated that
measurements at a distance of 30 meters or less are impractical. When performing
measurements at a distance other than that specified, the results shall be extrapolated to the
specified distance using an extrapolation factor of 20 dB/decade (inverse linear-distance for field
strength measurements; inverse-linear-distance-squared for power density measurements).

(2) At frequencies below 30 MHz, measurements may be performed at a distance closer than
that specified in the regulations; however, an attempt should be made to avoid making
measurements in the near field. Pending the development of an appropriate measurement
procedure for measurements performed below 30 MHz, when performing measurements at a
closer distance than specified, the results shall be extrapolated to the specified distance by
either making measurements at a minimum of two distances on at least one radial to determine
the proper extrapolation factor or by using the square of an inverse linear distance extrapolation
factor (40 dB/decade). This paragraph (f) shall not apply to Access BPL devices operating
below 30 MHz.
Restricted bands of operation




Note: 1Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
      2
       Above 38.6c


  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                                REPORT NO.: 4788418265-1-1
                                                                                              Page 17 of 32



  FCC Reference:                          Parts 15.231(b) / 15.209
  Test Method Used:                       ANSI C63.10 Sections 6.3 and 6.5


TEST SETUP
Below 30MHz




The setting of the spectrum analyser
RBW                         200Hz (From 9kHz to 0.15MHz)/ 9KHz (From 0.15MHz to 30MHz)
VBW                         200Hz (From 9kHz to 0.15MHz)/ 9KHz (From 0.15MHz to 30MHz)
Sweep                       Auto
Detector                    Peak/QP/ Average
Trace                       Max hold
1. The testing follows the guidelines in ANSI C63.10-2013
2. The EUT was arranged to its worst case and then turntable (from 0 degree to 360 degrees) to
find the maximum reading. A pre-amp and a high pass filter are used for the test in order to get
better signal level. Both horizontal and vertical polarizations of the antenna are set to make the
measurement.
3. The EUT was placed on a turntable with 0.8 meter above ground.
4. The EUT was set 3 meters from the interference receiving antenna, which was mounted on
the top of a variable height antenna tower.
5. The radiated emission limits are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated
emission limits in these three bands are based on measurements employing an average
detector.
6. For measurement below 1GHz, the initial step in collecting conducted emission data is a
spectrum analyzer peak detector mode pre-scanning the measurement frequency range.
Significant peaks are then marked and then Quasi Peak and average detector mode re-
measured. If the emission level of the EUT measured by the peak detector is 3 dB lower than
the applicable limit, the peak emission level will be reported. Otherwise, the emission
measurement will be repeated using the quasi-peak and average detector and reported.


  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                   FORM NO: 10-SL-F0035
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                           .


                                                                                REPORT NO.: 4788418265-1-1
                                                                                              Page 18 of 32

Below 1G




The setting of the spectrum analyser

RBW                         120K
VBW                         300K
Sweep                       Auto
Detector                    Peak/QP
Trace                       Max hold
1. The testing follows the guidelines in ANSI C63.10-2013.
2. The EUT was arranged to its worst case and then tune the antenna tower (from 1 m to 4 m)
and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a
high pass filter are used for the test in order to get better signal level. Both horizontal and
vertical polarizations of the antenna are set to make the measurement.
3. The EUT was placed on a turntable with 0.8 meter above ground.
4. The EUT was set 3 meters from the interference receiving antenna, which was mounted on
the top of a variable height antenna tower.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                   FORM NO: 10-SL-F0035
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                           .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 19 of 32

X axis, Y axis, Z axis positions:




Note: For all radiated test, EUT in each of three orthogonal axis emissions had been tested, but
only the worst case (X axis) data recorded in the report.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                                 REPORT NO.: 4788418265-1-1
                                                                                               Page 20 of 32

RESULTS

TEST ENVIRONMENT

Temperature                      25.1°C                                Relative Humidity          62%
Atmosphere Pressure              101kPa                                Test Voltage               AC 120V60Hz



         6.2.1. FUNDAMENTAL FIELD STRENGTH

                                                     HORIZONTAL




 No.                                                              Result        Limit          Margin
          Frequency           Reading         Correct                                                        Remark
                                                                   3m           (3m)
             (MHz)           (dBuV/m)           dB/m            (dBuV/m)      (dBuV/m)           (dB)
  1         13.3485            68.14           -41.62             26.52         80.51           -53.99         peak
  2         13.5600            91.95           -41.61             50.34         123.9           -73.66         peak
  3         13.7697            69.25           -41.60             27.65         80.51           -52.86         peak

Note: 1. Result 3m= Reading+ Correct Factor
      2. Result 30m= Result 3m-40 dBuV/m




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                     FORM NO: 10-SL-F0035
       This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                    (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                            .


                                                                                REPORT NO.: 4788418265-1-1
                                                                                              Page 21 of 32


                                                      VERTICAL




No.                                                              Result         Limit          Margin
        Frequency           Reading          Correct                                                         Remark
                                                                  3m            (3m)
           (MHz)            (dBuV/m)           dB/m            (dBuV/m)       (dBuV/m)           (dB)
 1        13.3493             58.04           -41.62             16.42          80.51           -64.09         peak
 2        13.5609             82.13           -41.61             40.52          123.9           -84.52         peak
 3        13.7723             60.38           -41.60             18.78          80.51           -61.73         peak

Note: 1. Result 3m= Reading+ Correct Factor
      2. Result 30m= Result 3m-40 dBuV/m




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                    FORM NO: 10-SL-F0035
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                           .


                                                                                REPORT NO.: 4788418265-1-1
                                                                                              Page 22 of 32

        6.2.2. SPURIOUS EMISSIONS BELOW 1G

                                                    HORIZONTAL




No.      Frequency          Reading         Correct         Result           Limit         Margin          Remark
            (MHz)          (dBuV/m)          dB/m         (dBuV/m)         (dBuV/m)         (dB)
 1         84.3200           57.58          -33.21          24.37            40.00         -15.63             QP
 2        149.3100           60.80          -29.00          31.80            43.50         -11.70             QP
 3        230.7900           62.24          -29.57          32.67            46.00         -13.33             QP
 4        257.9500           62.23          -29.52          32.71            46.00         -13.29             QP
 5        501.4200           53.76          -22.56          31.20            46.00         -14.80             QP
 6        515.0000           55.08          -22.16          32.92            46.00         -13.08             QP

Note: 1. Result Level = Read Level + Correct Factor.
      2. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                     FORM NO: 10-SL-F0035
      This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                   (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                           .


                                                                                 REPORT NO.: 4788418265-1-1
                                                                                               Page 23 of 32

                                                       VERTICAL




 No.      Frequency          Reading         Correct         Result           Limit         Margin          Remark
             (MHz)          (dBuV/m)          dB/m         (dBuV/m)         (dBuV/m)         (dB)
  1         46.4900           58.07          -31.35          26.72            40.00         -13.28             QP
  2         85.2900           64.00          -33.20          30.80            40.00          -9.20             QP
  3        203.6300           55.34          -27.03          28.31            43.50         -15.19             QP
  4        230.7900           57.33          -29.57          27.76            46.00         -18.24             QP
  5        487.8400           53.29          -22.79          30.50            46.00         -15.50             QP
  6        515.0000           54.59          -22.16          32.43            46.00         -13.57             QP


Note: 1. Result Level = Read Level + Correct Factor.
      2. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                     FORM NO: 10-SL-F0035
       This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                    (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                            .


                                                                                 REPORT NO.: 4788418265-1-1
                                                                                               Page 24 of 32


         6.2.3. SPURIOUS EMISSIONS BELOW 30M

                                                    HORIZONTAL

                                                   9KHz~ 150KHz




 No.      Frequency          Reading         Correct         Result            Limit        Margin          Remark
            (MHz)           (dBuV/m)          dB/m         (dBuV/m)         (dBuV/m)         (dB)
  1         0.0183            144.51         -41.59          102.92           122.60        -19.68            peak
  2         0.0379            141.26         -41.67           99.59           116.09        -16.50            peak
  3         0.0565            135.92         -41.76           94.16           112.59        -18.43            peak
  4         0.0761            130.09         -41.84           88.25           109.99        -21.74            peak
  5         0.0947            122.24         -41.93           80.31           108.09        -27.78            peak
  6         0.1313            116.10         -41.97           74.13           105.25        -31.12            peak

 Note: 1. Measurement = Reading Level + Correct Factor.
       2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to
comply with AV limit.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                    FORM NO: 10-SL-F0035
       This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                    (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                            .


                                                                                 REPORT NO.: 4788418265-1-1
                                                                                               Page 25 of 32

                                                  150KHz ~ 30MHz




 No.      Frequency          Reading         Correct         Result           Limit         Margin          Remark
            (MHz)           (dBuV/m)          dB/m         (dBuV/m)         (dBuV/m)         (dB)
  1         0.3886            94.66          -42.13          52.53            95.84         -43.31            peak
  2         0.6276            91.17          -42.32          48.85            71.67         -22.82            peak
  3         1.7071            84.67          -42.46          42.21            69.54         -27.33            peak
  4         4.8662            83.36          -42.10          41.26            69.54         -28.28            peak
  5        30.0000            77.95          -30.07          47.88            69.54         -21.66            peak

Note: 1. Measurement = Reading Level + Correct Factor.
       2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to
comply with AV limit.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                    FORM NO: 10-SL-F0035
       This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                    (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                            .


                                                                                 REPORT NO.: 4788418265-1-1
                                                                                               Page 26 of 32

                                                      VERTICAL

                                                   9KHz~ 150KHz




 No.      Frequency          Reading         Correct         Result            Limit        Margin          Remark
            (KHz)           (dBuV/m)          dB/m         (dBuV/m)         (dBuV/m)         (dB)
  1         0.0103            136.63         -41.55          95.08            127.42        -32.34            peak
  2         0.0297            132.44         -41.64          90.80            118.17        -27.37            peak
  3         0.0451            125.45         -41.71          83.74            114.57        -30.83            peak
  4         0.0606            122.25         -41.77          80.48            111.96        -31.48            peak
  5         0.0756            116.06         -41.84          74.22            110.05        -35.83            peak
  6         0.0908            109.39         -41.91          67.48            108.45        -40.97            peak
  7         0.1207            101.92         -41.96          59.96            105.97        -46.01            peak

Note: 1. Measurement = Reading Level + Correct Factor.
       2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to
comply with AV limit.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                    FORM NO: 10-SL-F0035
       This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                    (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                            .


                                                                                 REPORT NO.: 4788418265-1-1
                                                                                               Page 27 of 32

                                                  150KHz ~ 30MHz




 No.      Frequency          Reading         Correct         Result           Limit         Margin          Remark
            (MHz)           (dBuV/m)          dB/m         (dBuV/m)         (dBuV/m)         (dB)
  1         0.3588            90.21          -42.12          48.09            96.59         -48.50            peak
  2         0.8660            82.66          -42.41          40.25            68.87         -28.62            peak
  3         2.7170            80.61          -42.34          38.27            69.54         -31.27            peak
  4         3.6722            79.42          -42.20          37.22            69.54         -32.32            peak
  5         7.5228            78.97          -41.85          37.12            69.54         -32.42            peak
  6        20.8357            79.04          -41.94          37.10            69.54         -32.44            peak

Note: 1. Measurement = Reading Level + Correct Factor.
       2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to
comply with AV limit.




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                    FORM NO: 10-SL-F0035
       This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                    (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                            .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 28 of 32
         6.3.    99%/20dB BANDWIDTH
LIMITS


                                      FCC Part15 (15.247) Subpart C
                                             RSS-247 ISSUE 2

           Section                            Test Item                                       Limit


  RSS-Gen Clause 6.6                      99% Bandwidth                        For reporting purposes only.



TEST PROCEDURE


Connect the UUT to the spectrum analyser and use the following settings:

Center Frequency             The center frequency of the channel under test
Detector                     Peak
RBW                          1% to 5% of the occupied bandwidth
VBW                          approximately 3×RBW
Trace                        Max hold
Sweep                        Auto couple

Allow the trace to stabilize and measure the maximum width of the emission that is constrained
by the frequencies associated with the two outermost amplitude points (upper and lower
frequencies) that are attenuated by 99% relative to the maximum level measured in the
fundamental emission.

TEST SETUP




           EUT                          Attenuator




TEST ENVIRONMENT

Temperature                    25.1°C                                Relative Humidity          64%
Atmosphere Pressure            101kPa                                Test Voltage               AC 120V60Hz



  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                              REPORT NO.: 4788418265-1-1
                                                                                            Page 29 of 32

RESULTS




                     Frequency                99% bandwidth                20dB bandwidth
                       (MHz)                      (KHz)                        (KHz)

                        13.56                        2.126                        2.504




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
    This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                 (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                         .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 30 of 32


         6.4.    TRANSMITTER FREQUENCY STABILITY


LIMITS
The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating
frequency over a temperature variation of −20 degrees to + 50 degrees C at normal supply
voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply
voltage at a temperature of 20 degrees C.

TEST SETUP AND PROCEDURE

Connect the UUT to the spectrum analyser and use the following settings:

Center Frequency             The center frequency of the channel under test
Detector                     PEAK
RBW                          10KHz
VBW                          ≥3 × RBW
Span                         Encompass the entire emissions bandwidth (EBW) of the signal
Trace                        Max hold
Sweep time                   Auto

Allow the trace to stabilize, find the peak value of the power envelope and record the frequency,
then calculated the frequency drift.

The test extreme voltage is to change the primary supply voltage from 85 to 115 percent of the
nominal value.


TEST SETUP



                                                                        Spectrum
           EUT                          Attenuator                      Analyzer




  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .


                                                                              REPORT NO.: 4788418265-1-1
                                                                                            Page 31 of 32

TEST ENVIRONMENT
Temperature                   25.1°C                                Relative Humidity          64%
Atmosphere Pressure           101kPa                                Test Voltage               /


TEST RESULTS

       Maximum frequency error of the EUT with variations in ambient temperature

                                                               Time after
   Temperature
      (°C)                  0 minutes              2 minutes                5 minutes              10 minutes

        -20              13.5606 MHz              13.5605 MHz             13.5606 MHz             13.5606 MHz
        -10              13.5605 MHz              13.5606 MHz             13.5606 MHz             13.5605 MHz
         0               13.5606 MHz              13.5606 MHz             13.5605 MHz             13.5606 MHz
         10              13.5605 MHz              13.5605 MHz             13.5605 MHz             13.5606 MHz
         20              13.5606 MHz              13.5605 MHz             13.5603 MHz             13.5605 MHz
         30              13.5606 MHz              13.5606 MHz             13.5606 MHz             13.5606 MHz
         40              13.5606 MHz              13.5605 MHz             13.5606 MHz             13.5605 MHz
         50              13.5605 MHz              13.5606 MHz             13.5606 MHz             13.5606 MHz

Maximum frequency error of the EUT with variations in nominal operating voltage at an ambient

                                             Normal temperature


              Nominal            Measured
   Supply    Frequency           Frequency        Frequency Frequency               Limit     Margin
  Voltage (V) (MHz)                               Error (Hz) Error (%)                                      Result
                                   (MHz)                                            (%)        (%)

     102            13.56         13.5608             800            0.006          0.01        0.004        Pass
     120            13.56         13.5606             600            0.004          0.01        0.006        Pass
     138            13.56         13.5607             700            0.005          0.01        0.005        Pass




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
    This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                 (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                         .


                                                                               REPORT NO.: 4788418265-1-1
                                                                                             Page 32 of 32
7. ANTENNA REQUIREMENTS
PPLICABLE REQUIREMENTS

Please refer to FCC §15.203
If directional gain of transmitting antennas is greater than 6dBi, the power shall be reduced by
the same level in dB comparing to gain minus 6dBi. For the fixed point-to-point operation, the
power shall be reduced by one dB for every 3 dB that the directional gain of the antenna
exceeds 6 dBi. The use of a permanently attached antenna or of an antenna that uses a unique
coupling to the intentional radiator shall be considered sufficient to comply with the FCC rule.


ANTENNA CONNECTOR
EUT has an Integrated antenna without antenna connector.


ANTENNA GAIN
The antenna gain of EUT is less than 6 dBi.




                                            END OF REPORT


  UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                  FORM NO: 10-SL-F0035
     This report shall not be reproduced except in full, without the written approval of UL Verification Services
                                  (Guangzhou) Co., Ltd, Song Shan Lake Branch.
                                                          .



Document Created: 2018-05-25 14:00:25
Document Modified: 2018-05-25 14:00:25

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC