08 ic test report

FCC ID: WQJ-KIOSKIIISRED

Test Report

Download: PDF
FCCID_2814108

                                                               Report No.: C150826Z01-RC1


                  INDUSTRY CANADA RSS-210
                                 TEST REPORT
                                           for
                                    ViVOpay Kiosk III
                                Model: ViVOpay Kiosk III
                                     Brand: ViVOpay
                                  Test Report Number:
                                    C150826Z01-RC1

                                        Issued for:

                                        ID TECH
                      10721 Walker Street, Cypress, California 90630

                                        Issued by:

           COMPLIANCE CERTIFICATION SERVICES (SHENZHEN) INC.
          No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd.,
                 Guan Lan Town, Baoan District, Shenzhen China
                             TEL: 86-755-28055000
                                  FAX: 86-755-28055221
                            Issued Date: September 28, 2015




                                    检 测
                                  CNAS L4818

Note: This report shall not be reproduced except in full, without the written approval of
Compliance Certification Services (Shenzhen) Inc. This document may be altered or
revised by Compliance Certification Services (Shenzhen) Inc. personnel only, and shall
be noted in the revision section of the document. The client should not use it to claim
product endorsement by TAF, A2LA, NVLAP, NIST or any government agencies. The
test result of this report relate only to the tested sample identified in this report.




IC : 9847A-KIIISRED                                                       Page 1 / 24


                                                                                        Report No.: C150826Z01-RC1


                                               Revision History

                                                                                      Effect
Rev.          Issue Date                                Revisions                     Page           Revised By
 00       September 28, 2015                           Initial Issue                   ALL            Nancy Fu




IC: 9847A-KIIISRED                                                                                    Page 2 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                                    Report No.: C150826Z01-RC1



                                               TABLE OF CONTENTS

1    TEST CERTIFICATION..................................................................................................... 4

2    EUT DESCRIPTION .......................................................................................................... 5

3    TEST METHODOLO1GY .................................................................................................. 6
    3.1.    RSS-210 RESTRICTED BANDS OF OPERATIONS ................................................ 6
    3.2.    DESCRIPTION OF TEST MODES............................................................................ 6

4    FACILITIES AND ACCREDITATIONS ............................................................................. 7
    4.1.    FACILITIES ............................................................................................................... 7
    4.2.    ACCREDITATIONS .................................................................................................. 7
    4.3.    MEASUREMENT UNCERTAINTY ............................................................................ 7

5    SETUP OF EQUIPMENT UNDER TEST .......................................................................... 8
    5.1.    DESCRIPTION OF SUPPORT UNITS ...................................................................... 8
    5.2.    SUPPORT EQUIPMENT .......................................................................................... 8

6    RSS 210 REQUIREMENTS .............................................................................................. 9
    6.1.    99% BANDWIDTH .................................................................................................... 9
    6.2.    RADIATED EMISSIONS ......................................................................................... 11
    6.3.    POWER LINE CONDUCTED EMISSIONS MEASUREMENT ................................ 20




IC: 9847A-KIIISRED                                                                                    Page 3 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1


1     TEST CERTIFICATION
Product             ViVOpay Kiosk III
Model               ViVOpay Kiosk III
Brand               ViVOpay
Tested              August 26~September 28, 2015
Applicant           ID TECH
                    10721 Walker Street, Cypress, California 90630

                    ID TECH
Manufacturer
                    10721 Walker Street, Cypress, California 90630


                                          APPLICABLE STANDARDS
                        STANDARD                                                    TEST RESULT

              IC RSS-210 ISSUE 8 with
                                                                             No non-compliance noted
             amendment December 2010

We hereby certify that:
Compliance Certification Services (Shenzhen) Inc. tested the above equipment in
accordance with the requirements set forth in the above standards. The test results show
that the equipment tested is capable of demonstrating compliance with the requirements
as documented in this report.
The test results of this report relate only to the tested sample identified in this report.




Approved by:                                                   Reviewed by:




Sunday Hu                                                      Ruby Zhang
Supervisor of EMC Dept.                                        Supervisor of Report Dept.
Compliance Certification Services (Shenzhen) Inc.              Compliance Certification Services (Shenzhen) Inc.




IC: 9847A-KIIISRED                                                                                    Page 4 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1


2     EUT DESCRIPTION
 Product                             ViVOpay Kiosk III
 Model                               ViVOpay Kiosk III
 Brand                               ViVOpay
 Model Discrepancy                   N/A
 Identify Number                     C150826Z01-RC1

 Power Supply                        DC7.5V Supplied by the adapter

 Received Date                       August 26, 2015

 Frequency Range                     13.56 MHz
 Transmit Power                      74.69dBuV/m(measured at 3m)
 Modulation Technique ASK
 Number of Channels                  1Channels
 Antenna Specification PCB Antenna with 0dBi gain (MAX)
 Temperature Range                   -25°C ~ +70°C
 Hardware Version                    80136304-001&80136302-001
 Software Version                    NEO v1.00




IC: 9847A-KIIISRED                                                                                    Page 5 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1


3     TEST METHODOLO1GY
The tests documented in this report were performed in accordance with IC RSS-210, IC
RSS-Gen, and ANSI C63.10:2013.

This submittal(s) (test report) is intended for IC Certification No: 9847A-KIIISRED filing to
comply with Industry CANADA RSS210.
3.1. RSS-210 RESTRICTED BANDS OF OPERATIONS
Restricted bands, identified in Table 3 of RSS-Gen.
                                                     (Note)
Table 3: Restricted Frequency Bands
             MHz                              MHz                            MHz                        GHz
        0.090-0.110                12.57675-12.57725                     960-1427                    9.0-9.2
      2.1735-2.1905                    13.36-13.41                     1435-1626.5                   9.3-9.5
        3.020-3.026                   16.42-16.423                    1645.5-1646.5                 10.6-12.7
        4.125-4.128                16.69475-16.69525                    1660-1710                  13.25-13.4
     4.17725-4.17775               16.80425-16.80475                  1718.8-1722.2                14.47-14.5
     4.20725-4.20775                   25.5-25.67                       2200-2300                  15.35-16.2
        5.677-5.683                    37.5-38.25                       2310-2390                   17.7-21.4
        6.215-6.218                      73-74.6                        2655-2900                  22.01-23.12
     6.26775-6.26825                    74.8-75.2                       3260-3267                   23.6-24.0
     6.31175-6.31225                     108-138                        3332-3339                   31.2-31.8
        8.291-8.294               156.52475-156.52525                  3345.8-3358                 36.43-36.5
        8.362-8.366                    156.7-156.9                      3500-4400                  Above 38.6
     8.37625-8.38675                     240-285                        4500-5150
     8.41425-8.41475                    322-335.4                       5350-5460
       12.29-12.293                     399.9-410                       7250-7750
    12.51975-12.52025                    608-614                        8025-8500
Note: Certain frequency bands listed in Table 3 and in bands above 38.6 GHz are
designated for licence-exempt applications. These frequency bands and the
requirements that apply to the devices are set out in the 200– and 300– series RSSs,
such as RSS-210 and RSS-310, which contain the requirements that apply to
licence-exempt radio apparatus.
3.2. DESCRIPTION OF TEST MODES
The EUT has been tested under operating condition.
Test program used to control the EUT for staying in continuous transmitting and receiving
mode is programmed.
The following test mode(s) were scanned during the preliminary test below 1G and
Below 1G:
    Test Item              Test mode                                     Worse mode

      Conducted Emission Mode 1: TX

      Radiated Emission               Mode 1: TX




IC: 9847A-KIIISRED                                                                                    Page 6 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1


4     FACILITIES AND ACCREDITATIONS
4.1. FACILITIES
All measurement facilities used to collect the measurement data are located at
    No.10-1, Mingkeda Logistics Park, No.18, Huanguan South Rd., Guan Lan Town,
    Baoan District, Shenzhen, China
 The sites are constructed in conformance with the requirements of ANSI C63.4, ANSI
    C63.7 and CISPR Publication 22. All receiving equipment conforms to CISPR
    Publication 16-1, “Radio Interference Measuring Apparatus and Measurement
    Methods.”
4.2. ACCREDITATIONS
Our laboratories are accredited and approved by the following accreditation body
according to ISO/IEC 17025.
               USA               A2LA
               China             CNAS
The measuring facility of laboratories has been authorized or registered by the following
approval agencies.
              USA               FCC
              Japan             VCCI(C-3478, R-3135, T-652, G-624)
              Canada            INDUSTRY CANADA
              Taiwan            BSMI
Copies of granted accreditation certificates are available for downloading from our web
site, http://www.ccssz.com
4.3. MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for
tests performed on the EUT as specified in CISPR 16-4-2:
                         Parameter                        Uncertainty
                    Radiated Emission, 30 to 200 MHz
                                                                                     +/-3.6880dB
                            Test Site : 966(2)
                   Radiated Emission, 200 to 1000 MHz
                                                                                     +/-3.6695dB
                            Test Site : 966(2)
                     Radiated Emission, 1 to 8 GHz                                   +/-5.1782dB
                        Radiated Emission, 8 to 18 GHz                               +/-5.2173dB
                          Conducted Emissions                                        +/-3.6836dB
                               Band Width                                               178kHz
                          Peak Output Power MU                                       +/-1.906dB
                              Band Edge MU                                           +/-0.182dB
                         Channel Separation MU                                        416.178Hz
                             Duty Cycle MU                                             0.054ms
                         Frequency Stability MU                                         226Hz
This uncertainty represents an expanded uncertainty expressed at approximately
the 95% confidence level using a coverage factor of k=2.
The measured result is above (below) the specification limit by a margin less than the
measurement uncertainty; it is therefore not possible to state compliance based on the
95% level of confidence. However, the result indicates that compliance (non-compliance)
is more probable than non-compliance) with the specification limit.


IC: 9847A-KIIISRED                                                                                    Page 7 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1


5        SETUP OF EQUIPMENT UNDER TEST
5.1. DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary
accessories or support units. The following support units or accessories were used to
form a representative test configuration during the tests.
5.2. SUPPORT EQUIPMENT
                                                                                                         Data            Power
 No.         Equipment         Model No.            Serial No.             FCC ID           Brand
                                                                                                         Cable            Cord
                                                                                                                     Unshielded
    1         Notebook             B475            WB04861612                DOC           LENOVO          N/A
                                                                                                                       1.80m
                              DSA-12PFA-05                                                                           Unshielded
    2          Adapter                                  N/A                   N/A             DVE          N/A
                               FUS 075100                                                                              1.50m


Note:
        Grounding was established in accordance with the manufacturer’s requirements and conditions for the
        intended use.




IC: 9847A-KIIISRED                                                                                    Page 8 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1


6     RSS 210 REQUIREMENTS
6.1. 99% BANDWIDTH
The test of the item was performed in accordance with the standards RSS-Gen 4.6.1.

MEASUREMENT EQUIPMENT USED
     Name of                                                              Serial              Last        Due
                      Manufacturer                  Model
    Equipment                                                            Number            Calibration Calibration
     Spectrum
                            Agilent                N9010A              MY52221469           09/24/2015        09/23/2016
     Analyzer
      Cable             HuberSuhner SUCOFLEX104PEA                           N/A                 N/A               N/A
Remark: Each piece of equipment is scheduled for calibration once a year.


Test Configuration



                             Spectrum
      EUT                    Analyzer




TEST PROCEDURE
    1. Place the EUT on the table and set it in the transmitting mode.
    2. Remove the antenna from the EUT and then connect a low loss RF cable from the
       antenna port to the spectrum analyzer.
    3. Set the spectrum analyzer as RBW=1kHz, VBW = 3kHz, Span = 10kHz, Sweep =
       auto.
    4. Record the max. reading.




TEST RESULTS
                       Frequency                   B
    Channel
                         (MHz)                   (kHz)
       CH1                13.56                 2.4094




IC: 9847A-KIIISRED                                                                                    Page 9 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1



                  Test Plot

                    99% Bandwidth




IC: 9847A-KIIISRED                                                                                    Page 10 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1

6.2. RADIATED EMISSIONS
6.2.1. LIMITS OF RADIATED EMISSIONS MEASUREMENT
All spurious emissions shall comply with the limits of RSS-Gen Table 2&5&6.
Table 2: Radiated Limits of Receiver Spurious Emissions
                                                         Field Strength
            Frequency (MHz)
                                                   (microvolts/m at 3 meters)*
                        30-88                                                         100
                       88-216                                                         150
                      216-960                                                         200
                     Above 960                                                        500
Note: *Measurements for compliance with limits in the above table may be performed at
distances other than 3 metres, in accordance with Section 7.2.7.

Table 5: General Field Strength Limits for Transmitters at Frequencies Above 30 MHz
                                                        Field Strength
           Frequency (MHz)
                                                 (microvolts/m at 3 meters)*
                        30-88                                                        100
                       88-216                                                        150
                      216-960                                                        200
                     Above 960                                                       500
Note: Transmitting devices are not permitted in restricted frequency bands or, unless stated
otherwise, in TV bands (54-72 MHz, 76-88 MHz, 174-216 MHz, 470-608 MHz and 614-806 MHz)
Table 6: General Field Strength Limits for Transmitters at Frequencies Below 30 MHz
(Transmit)
                              Field Strength              Magnetic H-Field Measurement Distance
Frequency (MHz)
                              (microvolts/m)             (microamperes/m)        (metres)

     0.009-0.490            2,400/F (F in kHz)          2,400/377F (F in kHz)                      300
     0.490-1.705            24,000/F (F in kHz) 24,000/377F (F in kHz)                              30
      1.705-30.0                      30                           N/A                              30
Note: The emission limits for the bands 9-90 kHz and 110-490 kHz are based on
measurements employing an average detector.
In the above emission table, the tighter limit applies at the band edges.
                                    Field Strength                 Field Strength
      Frequency (MHz)
                                  (μV/m at 3-meter)             (dBuV/m at 3-meter)
               30-88                                    100                                     40
              88-216                                    150                                    43.5
             216-960                                    200                                     46
            Above 960                                   500                                     54




IC: 9847A-KIIISRED                                                                                    Page 11 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certfication Services (Shenzhen) Inc.                        Report No.: €150826Z01—RC1


6.2.2. TEST INSTRUMENTS
                                   Radiated Emission Test Site 966 (2)
           .                                                                  Serial             Last              Due
Name of Equipment              Manufacturer          |Model Number           Number          Calibration       Calibration

 PSA Series Spectrum
       nalyzer
                                    Agilent               E4446A           uss4soosee         omgois            ow2r2016
 EMI TEST RECEIVER           ROHDE&SCHWARZ                  ESCI              100783          02/28/2015        02/27/2016

          Amplifier                 MITEQ             AM—1604—3000           1123808          03/18/2015        03/18/2016

     High Noise Amplifier           Agilent                84498           3008A01838         02/28/2015        02/27/2016

Board—Band Horn Antenna          Schwarzbeck            BBHA 9170            9170—497         02/28/2015        02/27/2016

        Bilog Antenna           SCHAFFNER                CBL6143               5082           02/28/2015        02/27/2016

        HormAntenna            SCHWARZBECK              BBHA9120               D286           02/28/2015        02/27/2016

        Loop Antenna            COM—POWER                 AL—130              121044          09/25/2015        09/24/2016

         Turn Table                   N/A                   N/A                 N/A              NCR               N.C.R
          Controller            Suno! Sciences            SC104V             022310—1            NCR               N.C.R

          Controller                  CT                    N/A                 N/A              NCR               N.C.R

 Temp. / Humidity Meter            Anymetre                JR913                N/A           02/28/2015        02/27/2016

       Antenna Tower                SUNOL                   TLT2                N/A              NCR               N.C.R
          Test SV                   FARAD                                     LZ—RF / CCS—SZ—3A2
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
          2. The FCC Site Registration number is 93105/90471.
          3. N.C.R = No Calibration Required.


6.2.3. TEST PROCEDURE (please refer to measurement standard)
1.     The EUT is placed on a turntable, which is 0.8m above ground plane.
2.      The turntable shall be rotated for 360 degrees to determine the position of maximum
       emission level.
3.     EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to
       find out the highest emissions.
4.      Maximum procedure was performed on the six highest emissions to ensure EUT
       compliance.
5.       And also, each emission was to be maximized by changing the polarization of
       receiving antenna both horizontal and vertical.
6.     Set the spectrum analyzer in the following setting as:
        Belove 3O0MHz:
             I9kHz~150kHz: RBW=200Hz / VBW=600Hz / Sweep=AUTO
             150kHz~30MHz: RBW=9kHz / VBW=27kHz / Sweep=AUTO
       Above 30MHz:
             RBW=100kHz / VBW=300kHz / Sweep=AUTO
 7. Repeat above procedures until the measurements for all frequencies are complete.

IC: 9847A—KIIISRED                                                                                    Page 12 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1




6.2.4. TEST SETUP
Below 30MHz

                                                                                         Antenna
                                                                                          tower


                                       3m
                                                                                            Loop antenna
          EUT
                                         4m
                                                                                         Spectrum /
                                                                                          Receiver


                 Turntable                    1m
                                0.8m
                                                                                        Pre-amp




    Reference ground plane


Below 1 GHz

                                                                                             Antenna
                                                                                              tower


                                    3m                                                       Bi-log
                                                                                            antenna
             EUT
                                            4m
                                                                                           Spectrum
                                                                                           analyzer


                    Turntable                    1m
                                  0.8m




        Reference ground plane



For the actual test configuration, please refer to the related item – Photographs of the
Test Configuration.




IC: 9847A-KIIISRED                                                                                    Page 13 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1

6.2.5. ATA SAMPLE

                                 Correction                                                      Antenna
 Frequency         Reading                         Result          Limit          Margin                        Remark
                                  Factor                                                          Pole
   (MHz)           (dBuV)                        (dBuV/m)        (dBuV/m)          (dB)
                                  (dB/m)                                                          (V/H)
  XXX.XXXX           47.40          -21.61          25.79           40.00          -14.21           V              QP

Frequency (MHz)                       = Emission frequency in MHz
Reading (dBuV)                        = Uncorrected Analyzer / Receiver reading
Correction Factor (dB/m)              = Antenna factor + Cable loss – Amplifier gain
Result (dBuV/m)                       = Reading (dBuV) + Corr. Factor (dB/m)
Limit (dBuV/m)                        = Limit stated in standard
Margin (dB)                           = Result (dBuV/m) – Limit (dBuV/m)
QP                                    = Quasi-peak Reading




IC: 9847A-KIIISRED                                                                                    Page 14 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1

6.2.6. TEST RESULTS

Below 30MHz(9kHz~30MHz)
Operation Mode:                TX                              Test Date:               September 26, 2015
                                  o
Temperature:                   24 C                            Tested by:               Eve Wang
Humidity:                      52% RH

  Frequency           Reading         Correction           Result            Limit           Margin           Remark
    (MHz)             (dBuV)           Factor            (dBuV/m)          (dBuV/m)           (dB)
                                       (dB/m)
    13.5600             60.40           14.29               74.69            124.00           -49.31            Peak




IC: 9847A-KIIISRED                                                                                    Page 15 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1



Operation Mode:                TX                              Test Date:               September 26, 2015
Temperature:                   24oC                            Tested by:               AD Gan
Humidity:                      52% RH


   Frequency            Reading          Correction           Result           Limit           Margin          Remark
     (MHz)              (dBμV)            Factor            (dBμV/m)         (dBμV/m)           (dB)
                                          (dB/m)
      0.0145              52.13            14.90               67.03           124.83           -57.80            QP
      0.0560              43.32             14.15              57.47           113.17           -55.70            QP
      0.0648              45.45             14.14              59.59           111.70           -52.11            QP
      7.4931              25.28             14.76              40.04            69.54           -29.50            QP
     14.1795              22.09             14.14              36.23            69.54           -33.31            QP
     21.5823              13.67             14.32              27.99            69.54           -41.55            QP
Remark:
1. The emission behaviour belongs to narrowband spurious emission.
2. Measurements above show only up to 6 maximum emissions noted, or would be lesser, with
   “ N/A ” remark, if no specific emissions from the EUT are recorded (ie: margin>20dB from the
   applicable limit) and considered that's already beyond the background noise floor.
3. dBuV=dBuA+51.5dB




IC: 9847A-KIIISRED                                                                                    Page 16 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1



Below 1 GHz(30MHz~1GHz)
  Frequency         Reading        Correction   Result   Limit                    Margin        Antenna        Remark
    (MHz)           (dBμV)          Factor    (dBμV/m) (dBμV/m)                    (dB)          Pole
                                    (dB/m)                                                       (V/H)
    40.6700           49.93          -16.69     33.24    40.00                      -6.76          V              QP
   232.7300           56.57           -21.75          34.82          46.00         -11.18            V            QP
   299.6600           55.48           -19.60          35.88          46.00         -10.12            V            QP
   375.3200           47.66           -16.82          30.84          46.00         -15.16            V            QP
   515.0000           45.22           -14.19          31.03          46.00         -14.97            V            QP
   721.6100           40.63           -11.82          28.81          46.00         -17.19            V            QP

    40.6700           48.71           -16.69          32.02          40.00          -7.98           H             QP
   232.7300           59.92           -21.75          38.17          46.00          -7.83           H             QP
   298.6900           59.74           -19.69          40.05          46.00          -5.95           H             QP
   366.5900           53.99           -17.28          36.71          46.00          -9.29           H             QP
   487.8400           45.98           -14.36          31.62          46.00         -14.38           H             QP
   515.0000           47.20           -14.19          33.01          46.00         -12.99           H             QP


REMARKS:
1. Measuring frequencies from 9kHz to the 1GHz.
2. Radiated emissions measured in frequency range from 30 MHz to 1000MHz
   were made with an instrument using quasi-peak detector mode.
3. Measurements above show only up to 6 maximum emissions noted, or would be
   lesser, with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
   margin>20dB from the applicable limit) and considered that's already beyond the
   background noise floor.
4. Margin (dB) = Remark result (dBuV/m) – Quasi-peak limit (dBuV/m)




IC: 9847A-KIIISRED                                                                                    Page 17 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1



6.3. FREQUENCY STABILITY
LIMIT
According to RSS-210 §A2.6, carrier frequency stability shall be maintained to
±0.01% (±100 ppm).
TEST CONFIGURATION
Temperature and Voltage Measurement (under normal and extreme test conditions)



                                                         Temperature Chamber




         Spectrum Analyzer                                              EUT




                                                        AC/DC Power supply



TEST PROCEDURE
   1. Place the EUT on the table and set it in the transmitting mode.
   2. Remove the antenna from the EUT and then connect a low loss RF cable from the
      antenna port to the spectrum analyzer.
   3. Set the environment into appropriate environment.
   4. Set the spectrum analyzer as RBW=1kHz, VBW = RBW, Span = 200kHz, Sweep =
      auto.
   5. Mark the peak frequency and measure the frequency tolerance using frequency
      counter function.
   6. Repeat until all the results are investigated.




IC: 9847A-KIIISRED                                                                                    Page 18 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                          Report No.: C150826Z01-RC1



TEST RESULTS
No non-compliance noted.

Temperature Variations
                               Measured            Delta
   Temp.         Voltage                                         Tolerance         Limit        Margin         Result
                               Frequency        Frequency
    (oC)          (VDC)                                             (%)            (±%)          (%)         (Pass/Fail)
                                 (MHz)             (Hz)
     -20                       13.5606424             10          0.00007          0.01        -0.00993          Pass

     -10                       13.5606318             30          0.00022          0.01        -0.00978          Pass

      0                        13.5606292             10          0.00007          0.01        -0.00993          Pass

     10                        13.5606485            170          0.00125          0.01        -0.00875          Pass
                    7.5
     20                        13.5606518             10          0.00007          0.01        -0.00993          Pass

     30                        13.5606592             80          0.00059          0.01        -0.00941          Pass

     40                        13.5606435             20          0.00015          0.01        -0.00985          Pass

     50                        13.5606658            100          0.00074          0.01        -0.00926          Pass


 Voltage Variations
                               Measured            Delta
   Temp.         Voltage                                        Tolerance         Limit         Margin         Result
                               Frequency        Frequency
    (oC)          (VDC)                                            (%)            (±%)           (%)         (Pass/Fail)
                                 (MHz)             (Hz)
                   6.75        13.5606572           150           0.00111          0.01        -0.00889          Pass

     20            7.50        13.5607258            10           0.00007          0.01        -0.00993          Pass

                   8.25        13.5607691            40           0.00029          0.01        -0.00971          Pass




IC: 9847A-KIIISRED                                                                                    Page 19 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                         Report No.: C150826Z01-RC1

6.4. POWER LINE CONDUCTED EMISSIONS MEASUREMENT
6.4.1. LIMITS OF CONDUCTED EMISSIONS MEASUREMENT
According to RSS-Gen §7.2.4, except when the requirements applicable to a given
device state otherwise, for any radio apparatus equipped to operate from the public utility
AC power supply, either directly or indirectly (such as with a battery charger), the radio
frequency voltage of emissions conducted back onto the AC power lines in the frequency
range of 0.15 MHz to 30 MHz shall not exceed the limits shown in the table below. The
more stringent limit applies at the frequency range boundaries.
The conducted emissions shall be measured with a 50 ohm/50 microhenry line
impedance stabilization network (LISN).
                                                                             Limits
      Frequency Range                                                       (dBμV)
           (MHz)
                                                   Quasi-peak                                     Average
          0.15 to 0.50                               66 to 56*                                    56 to 46*
            0.50 to 5                                   56                                            46
             5 to 30                                    60                                            50
NOTE:
(1) The lower limit shall apply at the transition frequencies.
(2) The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.

TEST INSTRUMENTS
                                       Conducted Emission Test Site
      Name of                                                                                   Last        Due
                             Manufacturer          Model Number Serial Number
     Equipment                                                                               Calibration Calibration
EMI TEST RECEIVER ROHDE&SCHWARZ                           ESCI                100783          04/21/2014       04/21/2015
      LISN(EUT)           ROHDE&SCHWARZ                 ENV216              101543-WX         03/01/2015       03/01/2016
          LISN                    EMCO                   3825/2              8901-1459        03/01/2015       03/01/2016
Temp. / Humidity Meter           VICTOR                  HTC-1                  N/A           03/17/2015       03/17/2016
         Cable                HuberSuhner         SUCOFLEX104PEA                N/A               N/A              N/A
       Test S/W                  FARAD                                     EZ-EMC/ CCS-3A1-CE
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. N.C.R = No Calibration Request.




IC: 9847A-KIIISRED                                                                                    Page 20 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                             Report No.: C150826Z01-RC1

6.4.2. TEST PROCEDURES (please refer to measurement standard)

     The EUT and Support equipment, if needed, was placed on a non-conducted table,
      which is 0.8m above the ground plane and 0.4m away from the conducted wall.
     The test equipment EUT installed received AC main power, through a Line
      Impedance Stabilization Network (LISN), which supplied power source and was
      grounded to the ground plane. All support equipment power received from a second
      LISN. The two LISNs provide 50 ohm/ 50uH of coupling impedance for the measuring
      instrument.
     The EUT test program was started. Emissions were measured on each current
      carrying line of the EUT using an EMI Test Receiver connected to the LISN powering
      the EUT.
     The frequency range from 150 kHz to 30 MHz was searched. The test data of the
      worst-case condition(s) was recorded. Emission levels under limit 20dB were not
      recorded.

6.4.3. TEST SETUP

                                                           Vert. reference plane

                                                                                                       EMI receiver




                           40cm
                                            EUT



                                                                    80cm




               LISN
                                                                            Reference ground plane



        For the actual test configuration, please refer to the related item – Photographs of the Test
         Configuration.

6.4.4. DATA SAMPLE

             QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
Frequency                                                                                                         Line
  (MHz)       Reading   Reading    Factor         Result      Result       Limit     Limit    Margin   Margin
                                                                                                                 (L1/L2)
              (dBuV)    (dBuV)       (dB)         (dBuV)      (dBuV)     (dBuV)     (dBuV)     (dB)     (dB)
    X.XXXX     32.69     25.65      11.52         44.21        37.17       65.78    55.79     -21.57   -18.62         L1

 Frequency                        = Emission frequency in MHz
 QuasiPeak Limit (dBuV)           = Limit stated in standard
 Average Limit (dBuV)             = Limit stated in standard
 QuasiPeak Margin (dB)            = QuasiPeak Result (dBuV) –QuasiPeak Limit (dBuV)
 Average Margin (dB)              = Average Result (dBuV) –Average Limit (dBuV)
 L1                               = Line One (Live Line)
 L2                               = Line Two (Neutral Line)




IC: 9847A-KIIISRED                                                                                    Page 21 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1

6.4.5. TEST RESULTS
The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range. Significant peaks are then marked as shown on the following data
page, and these signals are then quasi-peaked.




IC: 9847A-KIIISRED                                                                                    Page 22 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1



Test Data

  Model No.              ViVOpay Kiosk III                              RBW,VBW                9 kHz
  Environmental o
               22 C, 45% RH                                             Test Mode              Normal
  Conditions
  Tested by              Eve Wang                                       Line                   L1

  Test Date              September 10, 2015




               QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
  Frequency                                                                                        Remark
    (MHz)       Reading Reading   Factor     Result    Result   Limit    Limit   Margin   Margin
                                                                                                  (Pass/Fail)
                (dBuV)   (dBuV)    (dB)      (dBuV)   (dBuV)   (dBuV)   (dBuV)    (dB)      (dB)
    0.1819       44.58       27.91       9.65        54.23      37.56      64.39       54.40      -10.16     -16.84      Pass

    0.3220       40.06       24.99       9.69        49.75      34.68      59.65       49.66        -9.90    -14.98      Pass

    0.5780       39.01       25.37       9.72        48.73      35.09      56.00       46.00        -7.27    -10.91      Pass

    1.0260       40.33       26.42       9.71        50.04      36.13      56.00       46.00        -5.96     -9.87      Pass

    1.6620       38.53       22.78       9.72        48.25      32.50      56.00       46.00        -7.75    -13.50      Pass

    9.1020       39.23       26.39       9.84        49.07      36.23      60.00       50.00      -10.93     -13.77      Pass

Note:
       1. Measuring frequencies from 0.15 MHz to 30MHz.
       2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made with
          an instrument using Peak detector, Quasi-peak detector and average detector.
       3. “---” denotes the emission level was or more than 2dB below the Average limit.
       4. The IF bandwidth of SPA between 0.15MHz to 30MHz was 10kHz; the IF bandwidth of
          Test Receiver between 0.15MHz to 30MHz was 9kHz;
       5. L1= Line One (Live Line)

IC: 9847A-KIIISRED                                                                                    Page 23 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                                                                                        Report No.: C150826Z01-RC1




  Model No.            ViVOpay Kiosk III                           RBW,VBW                 9 kHz
  Environmental o
               22 C, 45% RH                                        Test Mode               Normal
  Conditions
  Tested by            Eve Wang                                    Line                    L2

  Test Date            September 10, 2015




               QuasiPeak Average Correction QuasiPeak Average QuasiPeak Average QuasiPeak Average
  Frequency                                                                                        Remark
    (MHz)       Reading Reading   Factor     Result    Result   Limit    Limit   Margin   Margin
                                                                                                  (Pass/Fail)
                (dBuV)   (dBuV)    (dB)      (dBuV)   (dBuV)   (dBuV)   (dBuV)    (dB)      (dB)
    0.1580       43.63       27.80       9.78        53.41      37.58      65.56       55.57      -12.15     -17.99      Pass

    0.2860       39.05       25.99       9.76        48.81      35.75      60.64       50.64      -11.83     -14.89      Pass

    0.5860       37.49       21.66       9.68        47.17      31.34      56.00       46.00      -8.83      -14.66      Pass

    1.1539       35.54       16.91       9.79        45.33      26.70      56.00       46.00      -10.67     -19.30      Pass

    2.0780       35.76       17.34       9.73        45.49      27.07      56.00       46.00      -10.51     -18.93      Pass

    6.3100       39.46       23.50       9.78        49.24      33.28      60.00       50.00      -10.76     -16.72      Pass

Note:
    1. Measuring frequencies from 0.15 MHz to 30MHz.
    2. The emissions measured in frequency range from 0.15 MHz to 30MHz were made
       with an instrument using Peak detector, Quasi-peak detector and average detector.
    3. “---” denotes the emission level was or more than 2dB below the Average limit.
    4. The IF bandwidth of SPA between 0.15MHz to 30MHz was 10kHz; the IF
        bandwidth of Test Receiver between 0.15MHz to 30MHz was 9kHz;
    5. L2= Line Two (Neutral Line)


IC: 9847A-KIIISRED                                                                                    Page 24 / 24
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2015-11-06 09:28:25
Document Modified: 2015-11-06 09:28:25

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC