Test Report

FCC ID: WQJ-IDCA36-0119

Test Report

Download: PDF
FCCID_1067219

FCC ID: WQJ- IDCA36-0119




                              FCC TEST REPORT

                            REPORT NO.: 090110FIA01
                             MODEL NO.: IDCA-3620
                              RECEIVED: Jan. 14, 2009
                                TESTED: Jan. 14 ~ Jan. 19, 2009
                                 ISSUED: Feb. 04, 2009



                     APPLICANT: ID TECH

                          ADDRESS: 10721 Walker Street, Cypress, CA 90630, USA



                     ISSUED BY: ADT (Shanghai) Corporation
                                    2F, Building C, No.1618, Yishan rd., 201103,
               LAB LOCATION:
                                    Shanghai, China



 This test report consists of 34 pages in total. It may be duplicated completely for legal use with the
 approval of the applicant. It should not be reproduced except in full, without the written approval of
 our laboratory. The client should not use it to claim product endorsement by TAF, A2LA or any
 government agencies. The test results in the report only apply to the tested sample.




Report No.: 080913FIA01                             1                             Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



                                       Table of Contents
1         CERTIFICATION............................................................................................. 4
2         SUMMARY OF TEST RESULTS .................................................................... 5
2.1       MEASUREMENT UNCERTAINTY...................................................................5
3         GENERAL INFORMATION ............................................................................. 6
3.1       GENERAL DESCRIPTION OF EUT ................................................................6
3.2       DESCRIPTION OF TEST MODES ..................................................................7
3.2.1     CONFIGURATION OF SYSTEM UNDER TEST..............................................7
3.2.2     TEST MODE APPLICABILITY .........................................................................8
3.3       GENERAL DESCRIPTION OF APPLIED STANDARDS..................................9
3.4       FOR EMISSION TEST.....................................................................................9
4         TEST TYPES AND RESULTS ...................................................................... 10
4.1       CONDUCTED EMISSION MEASUREMENT.................................................10
4.1.1     LIMITS OF CONDUCTED EMISSION MEASUREMENT ..............................10
4.1.2     TEST INSTRUMENTS...................................................................................10
4.1.3     TEST PROCEDURE...................................................................................... 11
4.1.4     DEVIATION FROM TEST STANDARD.......................................................... 11
4.1.5     TEST SETUP.................................................................................................12
4.1.6     EUT OPERATING CONDITIONS ..................................................................12
4.1.7     TEST RESULTS ............................................................................................13
4.2       RADIATED EMISSION MEASUREMENT......................................................15
4.2.1     LIMIT OF RADIATED EMISSION MEASUREMEN........................................15
4.2.2     TEST INSTRUMENTS...................................................................................16
4.2.3     TEST PROCEDURE......................................................................................17
4.2.4     DEVIATION FROM TEST STANDARD..........................................................17
4.2.5     TEST SETUP.................................................................................................18
4.2.6     EUT OPERATING CONDITIONS ..................................................................18
4.2.7     TEST RESULTS ............................................................................................19
4.3       FREQUENCY STABILITY..............................................................................23
4.3.1     LIMITS OF FREQUENCY STABILITY MEASUREMENT ..............................23
4.3.2     TEST INSTRUMENTS...................................................................................23
4.3.3     TEST PROCEDURE......................................................................................24
4.3.4     DEVIATION FROM TEST STANDARD..........................................................24
4.3.5     TEST SETUP.................................................................................................25
4.3.6     EUT OPERATING CONDITIONS ..................................................................25
4.3.7     TEST RESULTS ............................................................................................26
4.4       BANDEDGE...................................................................................................27
4.4.1     LIMIT OF THE FIELD STRENGTH IN THE SPECIAL BAND FOR THE
          PRODUCTS OPERATION WITHIN THE BAND 13.110-14.010MHZ............27
4.4.2     TEST INSTRUMENTS...................................................................................27
4.4.3     TEST PROCEDURE......................................................................................28
4.4.4     DEVIATION FROM TEST STANDARD..........................................................28
4.4.5     TSET SETUP.................................................................................................29
4.4.6     EUT OPERATING CONDITIONS ..................................................................29
4.4.7     TEST RESULTS ............................................................................................29
5         PHOTOGRAPHS OF THE TEST CONFIGURATION ................................... 32


Report No.: 080913FIA01                                   2                                 Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


6         APPENDIX - INFORMATION ON THE TESTING LABORATORIES ............ 34




Report No.: 080913FIA01                3                    Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


1 CERTIFICATION

                 PRODUCT: OmniXpress/OmniFare
                    MODEL: IDCA-3620
                    BRAND: ID TECH
              APPLICANT: ID TECH
          TEST SAMPLE: ENGINEERING SAMPLE
                   TESTED: Jan. 14~ Jan. 19, 2009
             STANDARDS: FCC Part 15, Subpart C (Section 15.225)
                        ANSI C63.4-2003



 The above equipment has been tested by ADT (Shanghai) Corporation, and found
 compliance with the requirement of the above standards. The test record, data
 evaluation & Equipment Under Test (EUT) configurations represented herein are
 true and accurate accounts of the measurements of the sample’s EMC
 characteristics under the conditions specified in this report.




   PREPARED BY            :                                ,   DATE:    Feb. 04, 2009
                               ( Ray Xue / Engineer)

   TECHNICAL
   ACCEPTANCE             :                                ,   DATE:    Feb. 04, 2009
    Responsible for EMS         (Joy Zhu / Manager)



   APPROVED BY            :                                ,   DATE:    Feb. 04, 2009
                              ( Wallace Pan / Director )




Report No.: 080913FIA01                        4                       Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




2 SUMMARY OF TEST RESULTS

The EUT has been tested according to the following specifications:

       APPLIED STANDARD: FCC PART 15, SUBPART C (SECTION 15.225)

    STANDARD
                           TEST TYPE AND LIMIT      RESULT             REMARK
     SECTION
                                                             Meet the requirement of
                          AC Power Conducted                 limit.
        15.207                                       PASS
                          Emission                           Minimum passing margin
                                                             is -2.46dB at 27.12MHz

                                                             Meet the requirement of
      15.225(a)           Field Strength             PASS
                                                             limit.

                                                             Meet the requirement of
                                                             limit.
      15.225(d)           Radiated Emission          PASS
                                                             Minimum passing margin
                                                             is -1.99dB at 230.55MHz
                                                             Meet the requirement of
      15.225(e)           Frequency Stability        PASS
                                                             limit.


2.1 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated
for tests performed on the EUT as specified in CISPR 16-4-2:

This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.

                            Measurement                      Value
                     Conducted emissions                     2.55 dB
                          Radiated emissions                 3.99 dB




Report No.: 080913FIA01                         5                       Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


3       GENERAL INFORMATION

3.1 GENERAL DESCRIPTION OF EUT

EUT                                  OmniXpress/OmniFare
MODEL NO.                            IDCA-3620
FCC ID                               WQJ- IDCA36-0119
POWER SUPPLY                         120Vac, 60Hz
MODULATION TYPE                      ASK
FREQUENCY RANGE                      13.56MHz
NUMBER OF CHANNEL                    1
ANTENNA TYPE                         Soldered on PCB
                                     1m shielded RS232 cable with one core,
DATA CABLE
                                     undetachable
I/O PORTS                            Refer to user’s manual
ASSOCIATED DEVICES                   Adapter

NOTE:
 1. The EUT is powered by the following adapter.
                                     ADAPTER
        BRAND                     ID TECH
        MODEL                     MW41-0500500R
        INPUT POWER               120Vac, 60Hz, 5W
        OUTPUT POWER              5Vdc, 500mA
        POWER LINE                1.8m non-shielded cable with one core

    2. The above EUT information was declared by the manufacturer and for more detailed features
       description, please refer to the manufacturer's specifications or User's Manual.




Report No.: 080913FIA01                            6                          Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



3.2 DESCRIPTION OF TEST MODES

 The EUT only has one channel.
                  TRANSMITTER
      CHANNEL             FREQUENCY (MHz)
            1                  13.56




3.2.1 CONFIGURATION OF SYSTEM UNDER TEST




Report No.: 080913FIA01                     7   Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



3.2.2 TEST MODE APPLICABILITY
         EUT                     APPLICABLE TO
      CONFIGURE                                                           DESCRIPTION
        MODE               PLC            RE       FS

            1               √             √         √             Continuous card reading station

    Where       PLC: Power Line Conducted Emission
                RE: Radiated Emission
                FS: Frequency Stability


 POWER LINE CONDUCTED EMISSION TEST:

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
      between available modulations, data rates and antenna ports (if EUT with antenna diversity
      architecture).
     Following channel(s) was (were) selected for the final test as listed below.

                AVAILABLE                                TESTED                   MODULATION
                 CHANNEL                                CHANNEL                      TYPE

                       1                                   1                            ASK


 RADIATED EMISSION TEST:

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
      between available modulations, data rates, XYZ Axis and antenna ports (if EUT with antenna
      diversity architecture).
     Following channel(s) was (were) selected for the final test as listed below.

            AVAILABLE                      TESTED              MODULATION
                                                                                            AXIS
             CHANNEL                      CHANNEL                 TYPE

                  1                            1                  ASK                         Y


 FREQUENCY STABILITY:

     Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
      between available modulations, data rates and antenna ports (if EUT with antenna diversity
      architecture).
     Following channel(s) was (were) selected for the final test as listed below.

                AVAILABLE                                TESTED                   MODULATION
                 CHANNEL                                CHANNEL                      TYPE

                       1                                   1                            ASK




Report No.: 080913FIA01                                    8                             Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



3.3      GENERAL DESCRIPTION OF APPLIED STANDARDS

 The EUT is a RF Product. According to the specifications of the manufacturer, it
 must comply with the requirements of the following standards:

 FCC Part 15, Subpart C (15.225)
 ANSI C63.4-2003

 All test items have been performed and recorded as per the above standards.

 NOTE: The EUT is also considered as a kind of computer peripheral, because the connection to
         computer is necessary for typical use. It has been verified to comply with the requirements of
         FCC Part 15, Subpart B, Class B (DoC). The test report has been issued separately.


3.4 FOR EMISSION TEST

 The EUT has been tested as an independent unit together with other necessary
 accessories or support units. The following support units or accessories were used
 to form a representative test configuration during the tests.

  NO. PRODUCT               BRAND        MODEL NO. SERIAL NO.                        FCC ID
    1           PC           DELL            DCSM            E1P2012          FCC DoC Approved
    2        Monitor       Samsung            743N           E1M2004          FCC DoC Approved
    3       Keyboard       Logitech         Y-UR83           E1K2033          FCC DoC Approved
    4        Mouse         Logitech        M-BZ96C               N/A          FCC DoC Approved

        NO. SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
        A    1.2m shielded VGA cable with one core
        B    1.5m shielded USB cable without core
        C    1.5m shielded USB cable without core
        D    1m shielded RS232 cable with one core




Report No.: 080913FIA01                             9                            Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




4 TEST TYPES AND RESULTS

4.1 CONDUCTED EMISSION MEASUREMENT

4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT

     FREQUENCY OF EMISSION (MHz)                            CONDUCTED LIMIT (dBµV)

                                                         Quasi-peak                  Average
                     0.15 ~ 0.5                            66 to 56                  56 to 46
                      0.5 ~ 5                                56                        46
                       5 ~ 30                                60                        50
 NOTE: 1. The lower limit shall apply at the transition frequencies.
        2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to
            0.50MHz.
        3. All emanations from a class A/B digital device or system, including any network of
           conductors and apparatus connected thereto, shall not exceed the level of field
           strengths specified above.

4.1.2 TEST INSTRUMENTS
        DESCRIPTION &                                                                 CALIBRATED
                                          MODEL NO.               SERIAL NO.
        MANUFACTURER                                                                     UNTIL
          Test Receiver
                                            ESCS30                  E1R1002            Oct. 31, 2009
       ROHDE & SCHWARZ
              LISN
                                           NSLK8127                    E1L1001         Jul. 31, 2009
       ROHDE & SCHWARZ
              LISN
                                           NSLK8126                    E1L1002         Oct. 31, 2009
       ROHDE & SCHWARZ
            Software
                                      ADT_Cond_V7.3.0                    N/A                 N/A
               ADT




Report No.: 080913FIA01                            10                             Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


4.1.3 TEST PROCEDURE


 a. The EUT was placed 0.4 meters from the conducting wall of the shielded room
    with EUT being connected to the power mains through a line impedance
    stabilization network (LISN). Other support units were connected to the power
    mains through another LISN. The two LISNs provide 50 ohm/ 50uH of coupling
    impedance for the measuring instrument.

 b. Both lines of the power mains connected to the EUT were checked for maximum
    conducted interference.

 c. The frequency range from 150kHz to 30MHz was searched. Emission levels
    under (Limit - 20dB) was not recorded.



4.1.4 DEVIATION FROM TEST STANDARD
No deviation




Report No.: 080913FIA01                 11                       Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




4.1.5 TEST SETUP

                          V e r tic a l G r o u n d
                          R e fe r e n c e P la n e                                           Te s t R e c e iv e r


                          EUT
     40cm




                                                        80cm
      L IS N




                                                                         H o r iz o n ta l G r o u n d
                                                                         R e fe r e n c e P la n e

       N o t e : 1 . S u p p o r t u n i ts w e r e c o n n e c t e d t o s e c o n d L I S N .
                 2 . B o t h o f L IS N s ( A M N ) a r e 8 0 c m f r o m E U T a n d a t l e a s t 8 0 c m
                    f r o m o t h e r u n i ts a n d o t h e r m e ta l p l a n e s




For the actual test configuration, please refer to the attached file (Test Setup
Photo).


4.1.6 EUT OPERATING CONDITIONS

a. Set up PC as the usual using configuration.
b. Link EUT to PC by RS232 cable, then plug in power.
c. Run manufactory’s test software to make sure EUT continues emission
   station.
d. Take away the mouse, keyboard and monitor while test.




Report No.: 080913FIA01                                  12                                Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


4.1.7 TEST RESULTS

   INPUT POWER              120Vac, 60Hz                PHASE                 Line 1

   MODULATION                                           ENVIRONMENTAL         23deg. C, 65%RH,
                            ASK
   TYPE                                                 CONDITIONS            1006hPa
   TESTED BY                Ray Xue


                                                    Emission
            Freq.         Corr.    Reading Value                      Limit              Margin
                                                      Level
    No                    Factor     [dB (uV)]      [dB (uV)]       [dB (uV)]                 (dB)
            [MHz]          (dB)     Q.P.    AV.    Q.P.    AV.     Q.P.    AV.         Q.P.          AV.
     1    0.15            1.87     41.87   11.65   43.74   13.52   66.00   56.00    -22.26       -42.48
     2    0.45            0.61     34.38   6.04    34.99   6.65    56.95   46.95    -21.96       -40.30
     3    0.88            0.55     29.45   -1.06   30.00   -0.51   56.00   46.00    -26.00       -46.51
     4    6.71            0.88     22.32   16.81   23.20   17.69   60.00   50.00    -36.80       -32.31
     5    9.50            0.94     21.35   0.14    22.29   1.08    60.00   50.00    -37.71       -48.92
     6    27.13           1.54     42.01   42.01   43.55   43.55   60.00   50.00    -16.45       -6.45

REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
        2. "-": The Quasi-peak reading value also meets average limit and
            measurement with the average detector is unnecessary.
        3. The emission levels of other frequencies were very low against the limit.
        4. Margin value = Emission level - Limit value
        5. Correction factor = Insertion loss + Cable loss
        6. Emission Level = Correction Factor + Reading Value.




Report No.: 080913FIA01                            13                            Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




   INPUT POWER              120Vac, 60Hz                PHASE                 Line 2

   MODULATION                                           ENVIRONMENTAL         23deg. C, 65%RH,
                            ASK
   TYPE                                                 CONDITIONS            1006hPa
   TESTED BY                Ray Xue


                                                    Emission
            Freq.         Corr.    Reading Value                      Limit              Margin
                                                      Level
    No                    Factor     [dB (uV)]      [dB (uV)]       [dB (uV)]                 (dB)
            [MHz]          (dB)     Q.P.    AV.    Q.P.    AV.     Q.P.    AV.         Q.P.          AV.
     1    0.15            1.83     41.89   11.80   43.72   13.63   65.93   55.93    -22.21       -42.30
     2    0.47            0.60     35.34   4.81    35.94   5.41    56.58   46.58    -20.64       -41.17
     3    0.87            0.64     29.53   -0.23   30.17   0.41    56.00   46.00    -25.83       -45.59
     4    6.66            0.80     24.47   18.78   25.27   19.58   60.00   50.00    -34.73       -30.42
     5    9.33            0.89     27.46   13.73   28.35   14.62   60.00   50.00    -31.65       -35.38
     6    27.12           1.48     46.00   46.06   47.48   47.54   60.00   50.00    -12.52       -2.46

REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
        2. "-": The Quasi-peak reading value also meets average limit and
            measurement with the average detector is unnecessary.
        3. The emission levels of other frequencies were very low against the limit.
        4. Margin value = Emission level - Limit value
        5. Correction factor = Insertion loss + Cable loss
        6. Emission Level = Correction Factor + Reading Value.




Report No.: 080913FIA01                            14                            Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



4.2 RADIATED EMISSION MEASUREMENT

4.2.1 LIMIT OF RADIATED EMISSION MEASUREMEN

  According to 15.225 the field strength of Emissions from intentional radiators
  operated under these frequencies bands shall not exceed the following:
     Fundamental Frequency
                                              Field Strength of Fundamental (dBuV/m)
            (MHz)
                                                                    Quasi-Peak
           13.110 – 14.010
                                                                       124

  Field strength limits are at the distance of 3 meters, Emissions radiated outside of
  the specified bands, shall be according to the general radiated limits in 15.209 as
  following:

           FREQUENCIES                  FIELD STRENGTH                MEASUREMENT DISTANCE
              (MHz)                     (microvolts/meter)                  (meters)

            0.009 ~ 0.490                   2400/F(kHz)                          300
            0.490 ~ 1.705                  24000/F(kHz)                          30
             1.705 ~ 30.0                         30                             30
                30 ~ 88                          100                             3
               88 ~ 216                          150                             3
              216 ~ 960                          200                             3
              Above 960                          500                             3
  NOTE:
    1. The lower limit shall apply at the transition frequencies.
    2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
    3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
       average detector, however, the peak field strength of any emission shall not exceed the
       maximum permitted average limits, specified above by more than 20dB under any condition of
       modulation.




Report No.: 080913FIA01                             15                           Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



4.2.2 TEST INSTRUMENTS

         DESCRIPTION &                                                CALIBRATED
                                   MODEL NO.        SERIAL NO.
         MANUFACTURER                                                   UNTIL
              Spectrum
                                     E4403B          E1S1001           Jul. 31, 2009
               Agilent
              Receiver
                                    ESCS30           E1R1001           Oct. 31, 2009
                R&S
     Trilog Broadband Antenna
                                   VULB 9168         E1A1001           Aug. 31, 2009
            Schwarzbeck
        Active Loop Antenna
                                     AL-130          E1A1010           Aug. 31, 2009
             Com-power
            Horn Antenna
                                   BBHA 9120D        E1A1002           Sep. 30, 2009
            Schwarzbeck
             Preamplifier
                                     8447D           E1A2001           Oct. 01, 2010
               Agilent
             Preamplifier
                                     8449B           E1A2002           Aug. 01, 2009
               Agilent
              Software
                                ADT_Radiated_V7.5      N/A                   N/A
                ADT




Report No.: 080913FIA01                  16                      Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




4.2.3 TEST PROCEDURE


 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground
    at a 3 meter semi-anechoic camber. The table was rotated 360 degrees to
    determine the position of the highest radiation.
 b. The EUT was set 3 meters away from the interference-receiving antenna, which
    was mounted on the top of a variable-height antenna tower.
 c. The antenna is a broadband antenna, and its height is varied from one meter to
    four meters above the ground to determine the maximum value of the field
    strength. Both horizontal and vertical polarizations of the antenna are set to make
    the measurement. For test below 30MHz, we use loop antenna and its height
    fixed by 1m above the ground.
 d. For each suspected emission, the EUT was arranged to its worst case and then
    the antenna was tuned to heights from 1 meter to 4 meters and the rotatable
    table was turned from 0 degrees to 360 degrees to find the maximum reading.
 e. The test-receiver system was set to Peak Detect Function and Specified
    Bandwidth with Maximum Hold Mode.
 f. If the emission level of the EUT in peak mode was 10dB lower than the limit
    specified, then testing could be stopped and the peak values of the EUT would
    be reported. Otherwise the emissions that did not have 10dB margin would be
    re-tested one by one using peak, quasi-peak or average method as specified and
    then reported in a data sheet.


 NOTE:
     The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
     Peak detection (PK) and Quasi-peak detection (QP) at frequency below 1GHz.And 9kHz and
     30kHz for Peak detection (PK) and Quasi-peak detection (QP) at frequency below 30MHz




4.2.4 DEVIATION FROM TEST STANDARD
  No deviation




Report No.: 080913FIA01                          17                            Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




4.2.5 TEST SETUP




 For the actual test configuration, please refer to the attached file (Test Setup Photo).



4.2.6 EUT OPERATING CONDITIONS

Same as item 4.1.6.




Report No.: 080913FIA01                    18                        Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


4.2.7 TEST RESULTS
                                                            FREQUENCY
INPUT POWER                   120Vac, 60 Hz                                  Below 1000MHz
                                                            RANGE
ENVIRONMENTAL                 26deg. C, 68%RH,              DETECTOR
                                                                             Peak
CONDITIONS                    1006hPa                       FUNCTION
TESTED BY                     Ray Xue


      ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA 0 DEGREE OPEN AT 3 M
                       Reading Emission                     Antenna   Table
        Freq.  Factor                        Limit   Margin
    No.                  Value     Level                     Height  Angle
        [MHz]    (dB)  [dB (uV)] [dB (uV)] [dB (uV)]  (dB)    (m)   (Degree)
     1  13.56   11.59    67.55     79.14      124    -44.86    99       0

     ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA 90 DEGREE OPEN AT 3 M
                      Reading Emission                     Antenna   Table
        Freq.  Factor                       Limit   Margin
    No.                 Value     Level                     Height  Angle
        [MHz]   (dB)  [dB (uV)] [dB (uV)] [dB (uV)]  (dB)    (m)   (Degree)
     1  13.56  11.59    67.86     79.45      124    -44.55    99       0


REMARKS:          1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                  2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                  3. The other emission levels were very low against the limit.
                  4. Margin value = Emission level – Limit value.
                  5. ”∗”= Fundamental frequency.
                  6. Loop Antenna was used for all frequency below 30MHz.




Report No.: 080913FIA01                           19                           Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




INPUT POWER               120Vac, 60Hz             FREQUENCY RANGE 9kHz – 30MHz

ENVIRONMENTAL             26deg. C, 68%RH,         DETECTOR
                                                                           Quasi-Peak
CONDITIONS                1006hPa                  FUNCTION

TESTED BY                 Ray Xue



      ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA 0 DEGREE OPEN AT 3 M
                       Reading Emission                     Antenna   Table
        Freq.  Factor                        Limit   Margin
    No.                  Value     Level                     Height  Angle
        [MHz]    (dB)  [dB (uV)] [dB (uV)] [dB (uV)]  (dB)    (m)   (Degree)
     1  15.42   11.30    9.36      20.66     69.54   -48.89    99      327
     2  27.12    9.88    29.50     39.37     69.54   -30.17    99      352

    ANTENNA POLARITY & TEST DISTANCE: LOOP ANTENNA 90 DEGREE CLOSE AT 3 M
                      Reading Emission                     Antenna   Table
       Freq.  Factor                        Limit   Margin
   No.                  Value     Level                     Height  Angle
       [MHz]   (dB)   [dB (uV)] [dB (uV)] [dB (uV)]  (dB)    (m)   (Degree)
    1  22.86  10.73     14.56     25.29     69.54   -44.25    99      346
    2  27.12   9.88     34.57     44.44     69.54   -25.10    99      19

 REMARKS:         1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                  2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                  3. The other emission levels were very low against the limit.
                  4. Margin value = Emission level – Limit value.
                  5. Loop Antenna was used for all frequency below 30MHz.




Report No.: 080913FIA01                           20                           Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



                                                      FREQUENCY
  TEST MODE                  Mode 1                                           30-1000 MHz
                                                      RANGE
                                                      DETECTOR
  INPUT POWER                120Vac, 60 Hz            FUNCTION &              Quasi-Peak, 120kHz
                                                      BANDWIDTH
  ENVIRONMENTAL              32 deg. C, 57% RH,
                                                TESTED BY: Brain Chen
  CONDITIONS                 998hPa


           ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
            Freq.         Factor      Reading Emission    Limit      Margin      Tower         Table
  No.
           (MHz)           (dB)       (dbuv/m) (dbuv/m) (dbuv/m)      (dB)        cm            deg
   1      203.43          13.01        28.33     41.34     43.50      -2.16       99            107
   2      230.55          14.54        29.47     44.01     46.00      -1.99       100           335
   3      244.10          14.77        27.95     42.73     46.00      -3.27       100           352
   4      284.80          16.01        26.65     42.67     46.00      -3.33       100            3
   5      311.90          16.94        25.48     42.42     46.00      -3.58       100            6
   6      553.80          22.15        0.84      22.98     46.00     -23.02       100           192

          REMARKS:         1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                           2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                           3. The other emission levels were very low against the limit.
                          4. Margin value = Emission level – Limit value.




Report No.: 080913FIA01                             21                            Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



                                                      FREQUENCY
  TEST MODE                  Mode 1                                           30-1000 MHz
                                                      RANGE
                                                      DETECTOR
  INPUT POWER                120Vac, 60 Hz            FUNCTION &              Quasi-Peak, 120kHz
                                                      BANDWIDTH
  ENVIRONMENTAL              32 deg. C, 57% RH,
                                                      TESTED BY: Brain Chen
  CONDITIONS                 998hPa


             ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
            Freq.         Factor      Reading Emission    Limit      Margin      Tower         Table
  No.
           (MHz)           (dB)       (dbuv/m) (dbuv/m) (dbuv/m)      (dB)        cm            deg
   1       67.80          13.38        19.79     33.16     40.00      -6.84        99           287
   2      176.30          15.18        25.41     40.60     43.50      -2.90        99           207
   3      203.43          13.01        20.41     33.42     43.50     -10.08        99           248
   4      230.55          14.54        23.26     37.80     46.00      -8.20         0            0
   5      311.90          16.94        22.84     39.78     46.00      -6.22        99           233
   6      553.80          22.15        -4.62     17.52     46.00     -28.48        99           327

         REMARKS:          1. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
                           2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                           3. The other emission levels were very low against the limit.
                          4. Margin value = Emission level – Limit value.




Report No.: 080913FIA01                             22                            Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



4.3 FREQUENCY STABILITY


4.3.1 LIMITS OF FREQUENCY STABILITY MEASUREMENT
 The frequency tolerance of the carrier signal shall be maintained within +/- 0.01%
 of the operating frequency over a temperature variation of -20 degrees to 50
 degrees C at normal supply voltage, and for a variation in the primary supply voltage
 from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C.
 For battery operated equipment, the equipment tests shall be performed using a
 new battery.




4.3.2 TEST INSTRUMENTS

          DESCRIPTION &                                                   CALIBRATED
                                    MODEL NO.          SERIAL NO.
          MANUFACTURER                                                      UNTIL
             Spectrum
                                        FSP              E1S1002           Jul. 31, 2009
               R&S
           Digital Meter
                                        15B             E2M7003            Jul. 02, 2009
              FLUKE
  Temperature & humidity Chamber
                                   KTHC-715TBS            E3004            Jul. 21, 2009
            KING SON




Report No.: 080913FIA01                  23                         Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



4.3.3 TEST PROCEDURE

a.    The EUT was placed inside the environmental test chamber and powered by
      nominal DC voltage.
b.    Turn the EUT on and couple its output to a spectrum analyzer.
c.    Turn the EUT off and set the chamber to the highest temperature specified.
d.    Allow sufficient time (approximately 30 min) for the temperature of the chamber
      to stabilize, turn the EUT on and measure the operating frequency after 2, 5, and
      10 minutes.
e.    Repeat step 2 and 3 with the temperature chamber set to the following
      temperatures in the under table until to the lowest.
f.    The test chamber was allowed to stabilize at +20 degree C for a minimum of 30
      minutes. The supply voltage was then adjusted on the EUT from 85% to 115%
      and the frequency record.



4.3.4 DEVIATION FROM TEST STANDARD
No deviation




Report No.: 080913FIA01                    24                       Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




4.3.5 TEST SETUP




4.3.6 EUT OPERATING CONDITIONS

Same as item 4.1.6.




Report No.: 080913FIA01    25    Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


4.3.7 TEST RESULTS

         OPERATING FREQUENCY: 13.5616MHz                              LIMIT: ± 0.01%

                          0 MINUTE           2 MINUTE           5 MINUTE               10 MINUTE
      POWER
TEMP.
      SUPPLY
 (℃)
       (Vdc)       (MHz)         (%)     (MHz)      (%)     (MHz)       (%)        (MHz)         (%)


  50      120      13.5616           0   13.5616        0   13.5618    0.0015      13.5618      0.0015

  40      120      13.5616           0   13.5616        0   13.5618    0.0015      13.5618      0.0015

  30      120      13.5618      0.0015   13.5618   0.0015   13.5616        0       13.5618      0.0015

  20      120      13.5616           0   13.5616        0   13.5616        0       13.5616         0

  10      120      13.5616           0   13.5616        0   13.5616        0       13.5618      0.0015

  0       120      13.5618      0.0015   13.5618   0.0015   13.5618    0.0015      13.5618      0.0015

 -10      120      13.5618      0.0015   13.5618   0.0015   13.5622    0.0044      13.5618      0.0015

 -20      120      13.5622      0.0044   13.5622   0.0044   13.5622    0.0044      13.5622      0.0044



                          0 MINUTE
      POWER
TEMP.
      SUPPLY
 (℃)
       (Vdc)       (MHz)         (%)


  20      138      13.5616           0

  20      120      13.5616           0

  20      102      13.5616           0




Report No.: 080913FIA01                            26                           Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


4.4 BANDEDGE

4.4.1 LIMIT OF THE FIELD STRENGTH IN THE SPECIAL BAND FOR
     THE PRODUCTS OPERATION WITHIN THE BAND
     13.110-14.010MHZ
According to 15.225
(a) The field strength of any emissions within the band 13.553-13.567 MHz shall not
    exceed 15,848 microvolts/meter at 30 meters.
(b) Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength
    of any emissions shall not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of
    any emissions shall not exceed 106 microvolts/meter at 30 meters.
The limit of the field strength in the special band at the test distance of 3 meters shall
not exceed the following:


                          FREQUENCIES
                                                     FIELD STRENGTH (dBuV/m)
                             (MHz)

                 13.11-13.41,13.71-14.01                      80.5
               13.41-13.553,13.567-13.71                      90.5
                          13.553-13.567                        124



4.4.2 TEST INSTRUMENTS

       DESCRIPTION &                                                  CALIBRATED
                                    MODEL NO.            SERIAL NO.
       MANUFACTURER                                                      UNTIL

            Spectrum
                                          FSP             E1S1002     Jul. 31, 2009
               R&S
           Active Loop
            Antenna                   AL-130              E1A1010     Aug. 31, 2009
           Com-power
            Software
                                ADT_Radiated_V7.5           N/A              N/A
               ADT




Report No.: 080913FIA01                         27                    Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



4.4.3 TEST PROCEDURE

 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground
    at a 3 meter semi-anechoic camber. The table was rotated 360 degrees to
    determine the position of the highest radiation.

 b. The EUT was set 3 meters away from the interference-receiving antenna.
 c. The antenna is a loop antenna, with the antenna height 1 meter from the ground.
    Both 0 and 90 degrees of the antenna are set to make the measurement.

 d. For each suspected emission, the EUT was arranged to its worst case, and the
    rotatable table was turned from 0 degrees to 360 degrees to find the maximum
    reading.
 e. The test-receiver system was set to Peak Detect Function and Specified
    Bandwidth with Maximum Hold Mode.
 f. If the emission level of the EUT in peak mode was 10dB lower than the limit
    specified, then testing could be stopped and the peak values of the EUT would
    be reported. Otherwise the emissions that did not have 10dB margin would be
    re-tested one by one using peak, quasi-peak or average method as specified and
    then reported in a data sheet.


NOTE:
  The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer
   is 9 kHz and 30kHz for Peak detection (PK) and Quasi-peak detection (QP) at
   frequency below 30MHz.



4.4.4 DEVIATION FROM TEST STANDARD

   No deviation




Report No.: 080913FIA01                 28                       Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




4.4.5 TSET SETUP




For the actual test configuration, please refer to the attached file (Test Setup Photo).



4.4.6 EUT OPERATING CONDITIONS

Same as item 4.1.6.

4.4.7 TEST RESULTS
The following two plots show the emission in the special band.

Loop antenna: 0 degree




Report No.: 080913FIA01                    29                        Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


                                                       * RBW 10 kHz   Marker 1 [T1 ]
                                                       * VBW 30 kHz             77.78 dBµV
        Ref   137 dBµV         * Att    70 dB           SWT 10 ms         13.561800000 MHz


        130
                                                                                                   A

1 PK
        120
VIEW


        110
                                                                                                 TDF

        100

                                                                                                 PRN
        90


        Limit_1
        80                                         1



        70



        60



        50



        40

        Start 13.11 MHz                         90 kHz/                     Stop 14.01 MHz



Date:          16.JAN.2009   13:15:00


Loop antenna: 90 degree




Report No.: 080913FIA01                          30                        Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119


                                                       * RBW 10 kHz   Marker 1 [T1 ]
                                                       * VBW 30 kHz             80.14 dBµV
        Ref   137 dBµV         * Att    70 dB           SWT 10 ms         13.563058000 MHz


        130
                                                                                                   A

1 PK
        120
VIEW


        110
                                                                                                 TDF

        100

                                                                                                 PRN
        90


        Limit_1                                    1
        80



        70



        60



        50



        40

        Start 13.11 MHz                         90 kHz/                     Stop 14.01 MHz



Date:          16.JAN.2009   13:09:55




Report No.: 080913FIA01                          31                        Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




5 PHOTOGRAPHS OF THE TEST CONFIGURATION
                           CONDUCTED EMISSION TEST




Report No.: 080913FIA01              32              Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119



                           RADIATED EMISSION TEST




Report No.: 080913FIA01             33              Report Format Version 3.0.0


FCC ID: WQJ- IDCA36-0119




6 APPENDIX - INFORMATION ON THE TESTING LABORATORIES

We, ADT (Shanghai) Corporation, were founded in 2004 to provide our best service
in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited
and approved by the following approval agencies according to ISO/IEC 17025.

   USA                    FCC, A2LA
   Japan                  VCCI
   Canada                 INDUSTRY CANADA
   P.O.C.                 CNAS

Copies of accreditation certificates of our laboratories obtained from approval
agencies can be downloaded from our web site: www.cnadt.com. If you have
any comments, please feel free to contact us at the following:

   Shanghai EMC / RF / Auto Lab:
   Tel: +86-21-64659091
   Fax:+86-21-64659092




   Email: service@adt-sh.com
   Web Site: www.cnadt.com

The address and road map of all our labs can be found in our web site also.




--- END ---




Report No.: 080913FIA01                   34                        Report Format Version 3.0.0



Document Created: 2009-02-06 20:04:48
Document Modified: 2009-02-06 20:04:48

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC