user manual

FCC ID: WP5TWN4F1

Users Manual

Download: PDF
FCCID_1946838

Transponder Reader
      TWN4
Technical Handbook
      Rev. 2.1


                                                Elatec GmbH




Content
Content ............................................................................................... 2
1.         Introduction ............................................................................. 3
2.         Getting Started ......................................................................... 3
     2.1      Cable Connection ......................................................................... 3
     2.2      Enumeration ................................................................................. 3
     2.3      Initialization.................................................................................. 3
     2.4      Normal Operation ........................................................................ 4
     Detection of a Transponder ................................................................... 4
     2.5      Suspend Mode .............................................................................. 4
3.         Firmware and App programming ........................................... 6
     3.1      How to Blast ................................................................................. 7
     3.2      System Requirements ................................................................ 15
4.         Service Address ...................................................................... 16
5.         Regulatory Information ......................................................... 17
     5.1      CE Declaration of Conformity.................................................. 17
     5.2      FCC Statement ........................................................................... 18
     5.3      IC (Industry Canada) Statement .............................................. 19
6.         Trademarks ............................................................................ 20




                                                                                                Page 2 of 20


                                Elatec GmbH




1. Introduction
The transponder reader TWN4 is a device for reading and writing RFID
transponders. There are different versions of TWN4 devices available,
which cover a large range of transponder types both in the frequency range
of 125kHz and 13.56MHz.




2. Getting Started


2.1 Cable Connection
In order to start operating a TWN4 transponder reader, it simply has to be
connected to a host.




2.2 Enumeration
Once the device has been powered up, it is waiting for completion of the
enumeration by the USB host. As long as the device is not enumerated, it is
entering a minimum power consumption mode, where both LEDs are
turned off.




2.3 Initialization
After powering up and enumeration, the device is turning on the built-in
transponder reader logic. The green LED is turned on permanently. Some
transponder readers need some kind of initialization, which is performed in
                                                                 Page 3 of 20


                                 Elatec GmbH

this step. After successful initialization, the device sounds a short sequence,
which consists of a lower tone followed by a higher tone.




2.4 Normal Operation
As soon as the device has completed the initialization, it is entering normal
operation. During normal operation the device is searching for a
transponder continuously.




Detection of a Transponder
If a transponder is detected by the reader, following actions are performed

       Send the ID to the host. By default, the USB device sends by
        emulating keystrokes of a keyboard.

       Sound a beep

       Turn off the green LED

       Blink the red LED for two seconds

       Turn on the green LED
Within the two seconds timeout, where the red LED is blinking, the
transponder, which just has been recognized will not be accepted again.
This prevents the reader from sending identical IDs more than one time to
the host.
If during the two seconds timeout of the red LED a different transponder is
detected, the complete sequence restarts immediately.




2.5 Suspend Mode
The transponder reader supports the USB suspend mode. If the USB host
is signaling suspend via the USB bus, the transponder reader is turning off

                                                                   Page 4 of 20


                                Elatec GmbH

most of its power consuming peripherals. During this operation mode, no
detection of transponders is possible and all LEDs are turned off.
Once the host is resuming to normal operation mode, this is also signaled
via the USB bus. Therefore, the transponder reader will resume to normal
operation, too.




                                                                Page 5 of 20


                               Elatec GmbH




3. Firmware and App programming

AppBlaster provides many features to configure the multi-frequency reader
TWN4 for your own special application. This is done in an easy and fast
way: Easy and fast = Blast
The developer pack contains sample source codes (App), Windows driver
for serial communication (CDC Driver), firmware for serial communication
and for keyboard communication.




                                                               Page 6 of 20


                              Elatec GmbH




3.1 How to Blast

   Unpack the developer pack into an empty directory on your hard
    disk
   Connect a TWN4 to the PC
   Start program AppBlaster.exe
   At the beginning you might have to do a firmware update. You
    achieve this in the tab sheet “Program Apps & Firmware Images”.
    Choose the ‘Kx’ version for keyboard emulation and ‘Cx’ version for
    virtual COM port (CDC).
   Connecting first time to TWN4 requires installation of drivers. This is
    done automatically as long as you use keyboard emulation. CDC
    requires installation of drivers, which are part of the developer pack.




                                                                Page 7 of 20


                                 Elatec GmbH

Now you are ready to configure your first application:

    1) Select transponder type:




                                                         Page 8 of 20


                          Elatec GmbH

2) Change output format (binary, decimal, hexadecimal):




                                                          Page 9 of 20


           Read U
we®
TessCas
                     Bc teatrtiie



          Read UID
we®
 ToCas
                     Eestesttine
                                    ELATEC


Gat Garigant ce five
                |GeaeGion Fegan Sfrmeas hope |Setrgs
                                            Aesutet1D Langh   B Bre0de
                      Faca
                      t SoreeiaR/liee       [¥ Ryrntwabe —
                      w sorace              ces




Pegennca nage eces iescoaientaen
Dairing UsBdeven Feund USG ADnpoorteniuce
      cofsrnionnote OK




                                                                         + uge ie wiew


                               Elatec GmbH

Only 3 steps to create custom App: Take sample source codes or create
your own!




Select Source  choose an App (example: app_tracer.c)  select Make
App  select Program App




                                                             Page 12 of 20


                              Elatec GmbH

Difference sample “app_standard” and “app_tracer”:




Sample “app_dump“:




                                                     Page 13 of 20


                               Elatec GmbH

Only 2 steps to program apps (.app) and firmware images (.bix).




Select Image  choose Firmware  select Program image.




                                                                  Page 14 of 20


                               Elatec GmbH




3.2 System Requirements

Operating System: Windows XP, Vista, 7 (32-/64-bit).
Processor (CPU): 2 GHz (Minimum)
Hard Disk: Up to 200 MB of available space may be require.
RAM: 2 GB (Minimum)




                                                             Page 15 of 20


                                Elatec GmbH




4. Service Address




In case of any technical questions, please contact:
Elatec GmbH
Lilienthalstr. 3
82178 Puchheim
Germany

Phone: +49 (0) 89 5529961 0
Fax: +49 (0) 89 5529961 29
Email: info-rfid@elatec.com




                                                      Page 16 of 20


                                Elatec GmbH




5. Regulatory Information



5.1 CE Declaration of Conformity

This product conforms to the following standards:

RF:                    EN 300 330-2 V1.5.1
                       EN 302 291-2 V1.1.1
EMC:                   EN 301 489-1 V1.8.1
                       EN 301 489-3 V1.4.1

Human exposure:        EN 50371:2002

Safety:                EN 60950-1:2006 + A11:2009 + A1:2010




                                                          Page 17 of 20


                                 Elatec GmbH




5.2 FCC Statement
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

Section 15.21 Information to user
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment

Section 15.105 (b)
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.

If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:

       Reorient or relocate the receiving antenna.
       Increase the separation between the equipment and receiver.
       Connect the equipment into an outlet on a circuit different from that
        to which the receiver is connected.
       Consult the dealer or an experienced radio/TV technician for help.




                                                                  Page 18 of 20


                                  Elatec GmbH




5.3 IC (Industry Canada) Statement

“This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of
the device.“


“Le présent appareil est conforme aux CNR d'Industrie Canada applicables
aux appareils radio exempts de licence. L'exploitation est autorisée aux
deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage,
et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le
fonctionnement.”




                                                                    Page 19 of 20


                                Elatec GmbH




6. Trademarks
All referenced brands, product names, service names and trademarks
mentioned in this document are the property of their respective owners.




                                                                Page 20 of 20



Document Created: 2013-03-25 14:31:35
Document Modified: 2013-03-25 14:31:35

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC