manual

FCC ID: WP3NEXTCAMPG2

Users Manual

Download: PDF
FCCID_1416860

 NEXT CAM PG2,
 NEXT CAM-K9 PG2                                                                                 Installation Instructions
 Wireless, PowerG, PIR / Pet Immune Detectors with
 Integrated Camera

1. INTRODUCTION
The Next CAM PG2 is a 2-way, microprocessor-controlled,                   Camera operation modes:
wireless digital PIR detector with integrated camera and                     o Post alarm – pictures are taken after detection by
microphone for alarm verification.                                              detector.
The PIR detector's features are as follows:                                  o On demand – pictures are taken after a command from
 Combined Fresnel and cylindrical optics, up to 12 meters (40 ft).            the monitoring station.
 The Next CAM PG2 includes wall creep zone protection.
 For pet immune version - Target Specific Imaging™ (TSI)
   technology is used for distinction between human beings and
   pets weighing up to 38 kg (85lb).
 Includes a fully supervised PowerG transceiver.
 The advanced True Motion Recognition™ algorithm (patented)
                                                                                                                                 B
   allows distinguishing between the true motion of an intruder and                                                               C
   any other disturbances which may cause false alarms.
                                                                                                                                  D
 No vertical adjustment is needed.
 Motion event counter determines whether 1 or 2 consecutive                                                                     E
   motion events will trigger an alarm.
                                                                                             A
 Automatic termination of walk-test after 15 minutes.
 Microprocessor-controlled temperature compensation.
 Sealed chamber protects the optical system.
 Front cover and back tamper, for improved tamper protection.            A. Microphone
 White light protection.                                                 B. Camera lens
 Battery compartment                                                     C. IR LED
The camera's features are as follows:                                      D. Light sensor
 Day and night CMOS camera, with IR illumination. This allows            E. LEDs
   taking pictures in full darkness without letting the intruder know.
                                                                                                      Fig. 1. External View
 Camera range: 12 m (40ft). With IR illumination 10m (33 ft).
 Picture format and resolution: JPEG, QVGA (320x240 pixels).
 Frame rate: up to 3 fps (for user).
 Audio format: ADPCM, 4bit / 2bit.


2. SPECIFICATIONS
GENERAL
Detector Type: Dual element low-noise pyroelectric sensor                                        9 (30ft)

Lens Data: No. of Curtain Beams / curtains:
                                                                                                 6 (20ft)       90°
Next CAM PG2: 18 far, 18 mid, 10 close.                                                A
Next CAM-K9 PG2: 18 far, 18 mid, 18 close.                                                       3 (10ft)
Max. Coverage: 12 x 12 m, (40 x 40 ft) / 90°
Pet Immunity (Next CAM-K9 PG2 only): Up to 38 kg (85 lb).                                              0
ELECTRICAL
Internal Battery: 6V Lithium battery (two CR-123A 3V batteries                                   3 (10ft)
or two CR17450 3V batteries, in series) or equivalent.
                                                                                                 6 (20ft)
Note: For UL installations use Panasonic, Sanyo, GP or Varta
only. Use only the above battery. Dispose of used battery
according to the manufacturer's instructions.                                                    9 (30ft)
                                                                                                            0     3   6    9    12 m
Nominal Battery Capacity: 6V 1450 mA/h (2xCR123A), 2200                                                          10   20   30   40 ft
mA/h (2xCR17450)
Battery Life (for typical use): 3 or 5 years depending on battery
                                                                                       B          2.4 m
                                                                                                  (8 ft)
pack type (and camera version)
Optional MAINS supply: Additional to batteries, 7.5 V DC.                                        C
                                                                                                            0     3   6    9    12 m
Power Supply: Type C                                                                                             10   20   30   40 ft
FUNCTIONAL                                                               A. TOP VIEW
True Motion Event Verification: 2 remote selections - 1 (OFF)            B. SIDE VIEW
or 2 (ON) motion events                                                  C. Next CAM PG2: 0.5-4m, Next CAM -K9 PG2: 2-4m
Alarm Period: 2 seconds                                                             Fig. 2. Coverage Pattern & Walk-test

D-302893                                                                                                                                1


WIRELESS                                                              RFI Protection: >20 V/m up to 2000 MHz, excluding inband
Frequency Band (MHz): Europe: 433, 868, USA: 915                      frequencies
Modulation: GFSK                                                      Operating Temperatures: -10°C to 50°C (14°F to 122°F) indoor
Antenna: Built-in helical antenna                                     Storage Temperatures: -20°C to 60°C (-4°F to 140°F).
Communication Protocol: PowerG                                        Humidity: Average relative humidity of approximate 75% non-
                                                                      condensing. For 30 days per year relative humidity may vary
Supervision: Signaling at 4-min. intervals
                                                                      between 85 % and 95 % non-condensing.
Tamper Alert: Reported when a tamper event occurs and in any          Compliance with Standards:
subsequent message, until the tamper switch is restored
                                                                      USA: Designed to meet FCC Part 15
MOUNTING
                                                                      Europe: Directive 1999/5/EC of the European Parliament. EN
Height: 1.8 - 2.4 m (6 - 8 ft). For Next CAM-K9 PG2, the              50131-1 Grade 2 Class II. EN 50131-2-2, EN 50131-6
recommended height is up to 2.1 m (7 ft)
Installation Options: Surface or corner                               PHYSICAL
                                                                      Size (H x W x D): 125 x 63 x 60 mm (4-15/16 x 2-1/2 x 2-3/8”).
ACCESSORIES
                                                                      Weight (with battery): 200 g (7 oz).
BR-1: Surface mounted swivel bracket, adjustable 30° down and         Color: White
45° left/45° right.
                                                                      PATENTS
BR-2: BR-1 with a corner adapter
                                                                      U.S. Patents 5,693,943  6,211,522  D445,709 (another patent
BR-3: BR-1 with a ceiling adapter
                                                                      pending)
ENVIRONMENTAL


3. ENROLLMENT
Refer to the PowerMaster-10 Installer Guide for the device enrollment procedure.


4. MODIFY DEVICE SETTINGS
This section describes how to configure the parameters of the PIR detector from the PowerMaster-10 control panel.
To Modify the PIR Detector Device Settings

Refer to the PowerMaster-10 Installer Guide and perform the procedure for Adding A Wireless Device (section 4.5.2), or, Modifying a
Device (section 4.5.5). Then continue below to modify the device settings.
                DEV SETTINGS

1.
                  Alarm LED                  Here you determine whether or not the alarm LED indication will be activated.

2.
                   LED ON     
3.                       or                  Select between "LED ON" and "LED OFF".
4.
                  Alarm LED

5.
                Event Counter                Here you determine whether an alarm will be activated upon continued motion (low
                                             sensitivity) or upon a single alarm event (high sensitivity).
6.
              LED Sensitive       
7.                       or                  Select between "LOW sensitive" and "HIGH sensitive".
8.
                Event Counter

9.
              DISARM Activity                Here you set the activity time during disarm.

10.
               NOT Active         
11.                      or                  Select between "NOT Active", "YES – no delay", "YES + 5s delay", "YES + 15s
                                             delay", "YES + 30s delay", "YES + 1m delay", "YES + 2m delay", "YES + 5m
                                             delay", "YES + 10m delay", "YES + 20m delay" and "YES + 60m delay".
12.
              DISARM Activity

13.
              AC POWER CONNECT               Here you determine whether or not to report power failure and restore.

2                                                                                                                            D-302893


14.
           NOT connected   
15.                  or        Select between "NOT connected" and "Connected to AC".
16.
           AC POWER CONNECT

17.
             IMAGE COLOR       Here you determine whether the image will be in black & white or color.

18.
           Black & White   
19.                  or        Select between "Black & White" and "Color".
20.
             IMAGE COLOR

21.
           IMAGE RESOLUTION    Here you set the pixel quality of the image. Select 160 x 120 for lower quality or 320 x 240
                               for higher quality.
22.
           Resol. 160 x120

23.                  or        Select between "Resol. 160 x 120" and "Resol. 320 x 240".
24.
           IMAGE RESOLUTION

25.
           IMAGE BRIGHTNESS    Here you set the brightness of the image.

26.
            Normal        
27.                  or        Select between "-3", "-2", "-1", "Normal", "+1", "+2" and "+3".
28.
           IMAGE BRIGHTNESS

29.
            IMAGE CONTRAST     Here you set the contrast of the image.

30.
            Normal        
31.                  or        Select between "-3", "-2", "-1", "Normal", "+1", "+2" and "+3".
32.
            IMAGE CONTRAST

33.
            MIC. SETTINGS      Here you determine whether or not to activate the microphone.

34.
            Enable        
35.                  or        Select between "Enable" and "Disable".
36.
            MIC. SETTINGS




                               When exiting "ZONES / DEVICES" menu, the PowerMaster-10 system displays the
                               number of devices that need to be updated, as follows: DEV UPDATING NNN.
                               For detailed instructions on Adding Devices, Deleting Devices, Replacing Devices and
                               Defining Defaults see the PowerMaster-10 Installer Guide.




D-302893                                                                                                                 3


5. LOCAL DIAGNOSTICS TEST
A. Separate the base from the cover (see Fig. 5).                    IMPORTANT!          Reliable
B. Put back the cover to return the tamper switch to its normal
                                                                     reception must be assured.
    (undisturbed) position, and then secure the front cover to the
    base with the case closure screw.                                Therefore, "poor" signal
C. Walk-test the coverage area - see fig. 2. Walk across the far     strength is not acceptable.
    end of coverage pattern in both directions, The red LED lights   If you receive a "poor"
    each time your motion is detected followed by 3 LED blinks.      signal from the detector, re-
   The following table indicates received signal strength            locate it and re-test until a
   indication.                                                       "good" or "strong" signal
         LED response                            Reception           strength is received.
       Green LED blinks                            Strong
                                                                     Note: For detailed Diagnostics                    A
                                                                     Test instructions refer to
       Orange LED blinks                            Good             PowerMaster-10        Installer       A. Enroll button
                                                                     Guide.
        Red LED blinks                             Poor                                                      Figure 3. Device enroll button
          No blinks                          No communication



6. INSTALLATION
                                                                                    1                        2                         3
6.1 General Guidance (see fig. 4)
 1. Keep away from heat                5. Keep wiring away from
    sources.                              power cables.
 2. Do not expose to air               6. Do not install behind
    drafts.                               partitions.                               4                        5                         6
 3. Do not install outdoors.           7. Mount on solid stable
 4. Avoid direct sunshine.                surface.

WARNING! To comply with FCC RF exposure compliance
requirements, the PIR detector should be located at a distance of
at least 20 cm from all persons during normal operation. The                        7
antennas used for this product must not be co-located or
operated in conjunction with any other antenna or transmitter



                                                                                           Figure 4. General Guidelines
                                                                                        Important! The Next CAM-K9 PG2 detector is immune to 38 kg
                                                                                        (85 lb) animals moving on the floor or climbing on furniture as
                                                                                        long as the activity takes place below 1 m (3 ft). Above the 1 m
                                                                                        (3 ft) height limit, the detector is immune to 19 kg (42 lb) pets,
                                                                                        but the pet immunity will decrease as the pet gets closer to the
                                                                                        detector. It is therefore recommended to select a mounting
                                                                                        location that minimizes potential close proximity of animals.

6.2 Mounting
                                   2                                            3




                               1

                                                                                                                     A




4


                                                                                  5
                                          B




                                          4
                                                                                                   6




                   C
                                                                            7




               F                              D


                                                                                               G
                       E


    *CAUTION! THE BACK TAMPER SWITCH WILL NOT
    PROTECT THE UNIT UNLESS THE BREAK-AWAY BASE
    SEGMENT IS SECURED TO THE WALL WITH AT LEAST ONE
    SCREW.
                                     Figure 5a. Mounting on Wall

                                                     1. Release screw.
                                    8                2. Remove cover from base.
                                                     3. Position the battery in the battery holder and insert the battery
                                                        connector terminal into the battery connector.
                                                     4. For optional mains power supply: Break the cable entry
                                                        knockout and insert the mains cable.
                                                     5. Press the base against the wall at the selected mounting
                                                        position and mark the drilling points through the mounting
                                                        holes.
                                                     6. Drill 2 holes or 3 holes (for back tamper) and attach the base to
                                                        the wall using the screws.
                                                     7. Slide the external power adaptor circuit into its connector.
                                                     8. Align the cover with the base.
                                                     9. Secure with screw.
                                                     A. Battery connector.
                                                     B. Cable entry knockout.
                               9                     C. BR-1 Knockout
                                                     D. Mounting knockouts (for surface mounting)
                                                     E. Break-away base segment (shaded)
                                                        CAUTION! THE BACK TAMPER SWITCH WILL NOT
                                                        PROTECT THE UNIT UNLESS THE BREAK-AWAY BASE
                                                        SEGMENT IS SECURED TO THE WALL WITH AT LEAST
                                                        ONE SCREW.
                                                     F. Mounting knockouts (3 of 6 – for corner mounting).
               Figure 5b. Final Closure              G. Power adaptor circuit connector.


D-302893                                                                                                                5


7. SPECIAL COMMENTS
Even the most sophisticated detectors can sometimes be defeated                                                          particular installation. If this device does cause such interference,
or may fail to warn due to: DC power failure / improper connection,                                                      which can be verified by turning the device off and on, the user is
malicious masking of the lens, tampering with the optical system,                                                        encouraged to eliminate the interference by one or more of the
decreased sensitivity in ambient temperatures close to that of the                                                       following measures:
human body and unexpected failure of a component part.                                                                   – Re-orient or re-locate the receiving antenna.
The above list includes the most common reasons for failure to                                                           – Increase the distance between the device and the receiver.
detect intrusion, but is by no means comprehensive. It is therefore                                                      – Connect the device to an outlet on a circuit different from the one
recommended that the detector and the entire alarm system be                                                               that supplies power to the receiver.
checked weekly, to ensure proper performance.                                                                            – Consult the dealer or an experienced radio/TV technician.
An alarm system should not be regarded as a substitute for                                                                WARNING! Changes or modifications to this unit not expressly
insurance. Home and property owners or renters should be                                                                  approved by the party responsible for compliance could void the
prudent enough to continue insuring their lives and property, even                                                        user’s authority to operate the equipment..
though they are protected by an alarm system.
This device has been tested and found to comply with the limits for                                                       This device complies with FCC Rules Part 15. Operation is
a Class B digital device, pursuant to Part 15 of the FCC Rules.                                                           subject to two conditions: (1) This device may not cause harmful
These limits are designed to provide reasonable protection against                                                        interference, and (2) this device must accept any interference
harmful interference in residential installations. This equipment                                                         that may be received or that may cause undesired operation.
generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio and television reception.
However, there is no guarantee that interference will not occur in a


 WARRANTY
 Visonic Limited (the “Manufacturer") warrants this product only (the "Product") to the original purchaser only (the   However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or damage arising under this
 “Purchaser”) against defective workmanship and materials under normal use of the Product for a period of twelve       limited warranty, THE MANUFACTURER'S MAXIMUM LIABILITY (IF ANY) SHALL NOT IN ANY CASE
 (12) months from the date of shipment by the Manufacturer.                                                            EXCEED THE PURCHASE PRICE OF THE PRODUCT, which shall be fixed as liquidated damages and not as a
 This Warranty is absolutely conditional upon the Product having been properly installed, maintained and operated      penalty, and shall be the complete and exclusive remedy against the Manufacturer.
 under conditions of normal use in accordance with the Manufacturers recommended installation and operation            When accepting the delivery of the Product, the Purchaser agrees to the said conditions of sale and warranty and
 instructions. Products which have become defective for any other reason, according to the Manufacturers               he recognizes having been informed of.
 discretion, such as improper installation, failure to follow recommended installation and operational instructions,   Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so these
 neglect, willful damage, misuse or vandalism, accidental damage, alteration or tampering, or repair by anyone         limitations may not apply under certain circumstances.
 other than the manufacturer, are not covered by this Warranty.                                                        The Manufacturer shall be under no liability whatsoever arising out of the corruption and/or malfunctioning of any
 The Manufacturer does not represent that this Product may not be compromised and/or circumvented or that the          telecommunication or electronic equipment or any programs.
 Product will prevent any death and/or personal injury and/or damage to property resulting from burglary, robbery,     The Manufacturers obligations under this Warranty are limited solely to repair and/or replace at the
 fire or otherwise, or that the Product will in all cases provide adequate warning or protection. The Product,         Manufacturer’s discretion any Product or part thereof that may prove defective. Any repair and/or replacement
 properly installed and maintained, only reduces the risk of such events without warning and it is not a guarantee     shall not extend the original Warranty period. The Manufacturer shall not be responsible for dismantling and/or
 or insurance that such events will not occur.                                                                         reinstallation costs. To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid
 THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS                                 and insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this
 OR LIABILITIES, WHETHER WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF                                  Warranty.
 MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE. IN NO CASE SHALL                                   This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to
 THE MANUFACTURER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES                                      act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the
 FOR BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES WHATSOEVER, AS AFORESAID.                                         Product only. All products, accessories or attachments of others used in conjunction with the Product, including
 THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL,                                   batteries, shall be covered solely by their own warranty, if any. The Manufacturer shall not be liable for any
 CONSEQUENTIAL OR PUNITIVE DAMAGES OR FOR LOSS, DAMAGE, OR EXPENSE, INCLUDING LOSS                                     damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, caused by the
                                                                                                                       malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in
 OF USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY OR INDIRECTLY ARISING FROM
                                                                                                                       conjunction with the Products. This Warranty is exclusive to the original Purchaser and is not assignable.
 PURCHASER’S USE OR INABILITY TO USE THE PRODUCT, OR FOR LOSS OR DESTRUCTION OF                                        This Warranty is in addition to and does not affect your legal rights. Any provision in this warranty which is
 OTHER PROPERTY OR FROM ANY OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN ADVISED OF                                      contrary to the Law in the state or country were the Product is supplied shall not apply.
 THE POSSIBILITY OF SUCH DAMAGE.                                                                                       Warning: The user must follow the Manufacturer’s installation and operational instructions including testing the
 THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH, PERSONAL AND/OR BODILY                                        Product and its whole system at least once a week and to take all necessary precautions for his/her safety and
 INJURY AND/OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT, INDIRECT, INCIDENTAL,                                  the protection of his/her property.
 CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION.                                                                                                                                                      1/08




                     W.E.E.E. Product Recycling Declaration
                     For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not
                     returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
                     Directive 2002/96/EC Waste Electrical and Electronic Equipment.




VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): 65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT. 06002-1376. PHONE: (860) 243-0833, (800) 223-0020.
FAX: (860) 242-8094
VISONIC LTD. (UK): UNIT 6 MADINGLEY COURT CHIPPENHAM DRIVE KINGSTON MILTON KEYNES MK10 0BZ. TEL: (0870) 7300800
FAX: (0870) 7300801. TEL: (0870) 7300800 FAX: (0870) 7300801 PRODUCT SUPPORT: (0870) 7300830
VISONIC GmbH (D-A-CH): KIRCHFELDSTR. 118, D-40215 DÜSSELDORF, TEL.: +49 (0)211 600696-0, FAX: +49 (0)211 600696-19
VISONIC IBERICA: ISLA DE PALMA, 32 NAVE 7, POLÍGONO INDUSTRIAL NORTE, 28700 SAN SEBASTIÁN DE LOS REYES, (MADRID), ESPAÑA.
TEL (34) 91659-3120, FAX (34) 91663-8468. www.visonic-iberica.es
INTERNET: www.visonic.com
VISONIC LTD. 2010 NEXT CAM PG2, NEXT CAM-K9 PG2 D-302893 (preparation for revision 1, 10/10)




6                                                                                                                                                                                                                         D-302893



Document Created: 2011-01-24 11:14:29
Document Modified: 2011-01-24 11:14:29

© 2024 FCC.report