Test Report

FCC ID: WNG-WCP-21

Test Report

Download: PDF
FCCID_4269928

                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21




                    FCC PART 15C TEST REPORT FOR CERTIFICATION
                                     On Behalf of

                                Rondish Company Limited

                               Wireless Call Point Transmitter

                                          WCP-21

                                   FCC ID: WNG-WCP-21




                           Prepared for : Rondish Company Limited
                                          Unit G&H, 4/F, Block 1, Kwai Tak Ind. Ctr. 15-33 Kwai
                                          Tak St., Kwai Chung, N.T., Hong Kong




                           Prepared By : Audix Technology (Shenzhen) Co., Ltd.
                                         No. 6, Kefeng Road, Science & Technology Park,
                                         Nanshan District , Shenzhen, Guangdong, China

                                         Tel: (0755) 26639496




                           Report Number :        ACS-F19044
                           Date of Test   :       Feb.12~Apr.15,2019
                           Date of Report :       May.05,2019




                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 1 of 28


                                                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21


                                                     TABLE OF CONTENTS

    Description                                                                                                                                       Page
   1.    SUMMARY OF STANDARDS AND RESULTS............................................................. 4
         1.1.     Description of Standards and Results...................................................................................... 4
   2.    GENERAL INFORMATION ............................................................................................ 5
         2.1.     Description of Device (EUT) .................................................................................................. 5
         2.1.     EUT Configuration and operation conditions for test ............................................................. 6
         2.2.     Test Facility ............................................................................................................................. 6
         2.3.     Measurement Uncertainty (95% confidence levels, k=2) ....................................................... 6
   3.    POWER LINE CONDUCTED EMISSION TEST .......................................................... 7
   4.    RADIATED EMISSION TEST ......................................................................................... 8
         4.1.     Test Equipment ........................................................................................................................ 8
         4.2.     Block Diagram of Test Setup .................................................................................................. 9
         4.3.     Radiated Emission Limit ....................................................................................................... 10
         4.4.     EUT Configuration on Test ................................................................................................... 10
         4.5.     Operating Condition of EUT ................................................................................................. 10
         4.6.     Test Procedure ....................................................................................................................... 10
         4.7.     Radiated Emission Test Results ............................................................................................ 10
   5.    STOP TRANSMITTING TIME TEST........................................................................... 15
         5.1.     Test Equipment ...................................................................................................................... 15
         5.2.     Limit ...................................................................................................................................... 15
         5.3.     Test Results ........................................................................................................................... 15
   6.    CEASE TIME AFTER ACTIVATION TEST ............................................................... 16
         6.1.     Test Equipment ...................................................................................................................... 16
         6.2.     Limit ...................................................................................................................................... 16
         6.3.     Test Result ............................................................................................................................. 16
   7.    20 DB BANDWIDTH TEST ............................................................................................ 17
         7.1.     Test Equipment ...................................................................................................................... 17
         7.2.     Limit ...................................................................................................................................... 17
         7.3.     Test Results ........................................................................................................................... 17
   8.    ANTENNA REQUIREMENT ......................................................................................... 18
   9.    RADIO FRREQUENCY EXPOSURE COMPLIANCE ............................................... 19
   10.   DEVIATION TO TEST SPECIFICATIONS................................................................. 20
   11.   PHOTOGRAPH OF TEST .............................................................................................. 21
         11.1. Photos of Radiated Emission Test ......................................................................................... 21
   12.   PHOTOGRAPH OF EUT ................................................................................................ 22




                                                                      Audix Technology (Shenzhen) Co., Ltd.               Report No. ACS-F19044 page 2 of 28


                      ®
 A U D IX                                                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG—WCP—21



                               TEST REPORT CERTIFICATION
     Applicant             *   Rondish Company Limited
     Manufacturer          *   Rondish Company Limited

     Product               *   Wireless Call Point Transmitter

     FCC ID                :   WNG—WCP—21
                               (A)Model No.              : WCP—21
                               (B)Power Supply       :     DC3V
                               (C)Fest Voltage       :     DC 3V.
     Tested for comply with:
     FCC CFR47 Part 15 Subpart C

     Test procedure used:
     ANSI C63.10: 2013

     The device described above is tested by AUDIX TECHNOLOGY (SHENZHEN) CO., LTD. to
     confirm comply with all the FCC Part 15 Subpart C requirements.

     The test results are contained in this test report and AUDIX TECHNOLOGY (SHENZHEN) CO.,
     LTD. is assumed full responsibility for the accuracy and completeness of these tests. This report
     contains data that are not covered by the NVLAP accreditation. Also, this report shows that the
     Equipment Under Test (EUT) is to be technically compliant with the FCC requirements.

     This report applies to above tested sample only. This report shall not be reproduced in part without
     written approval of AUDIX TECHNOLOGY (SHENZHEN) CO., LTD.

     The report must not be used by the client to claim product certification, approval, or endorsement by
     NVLAP, NIST, or any agency of the federal government.

     Date of Test :        Feb.12~Apr.15,2019            Report of date:                    May.05,2019




     Prepared by :        __/?7onza L\,q )DoJ            Reviewed by :              4W‘4 m
                          Brave Zhang / Afi{stant                                  Sunny Lu /\j)uty Manager

                                           ap e          ® 4# ffi&            4 4
                                                                     (Kk#) &RA
                                                            Audix Technology (Shenzhen) Co., Ltd.
                                                           EMC # N # 4 % A ¥
                                                  Stamp only for EMC Xept. Report

     Approved & Authorized Signer :               Signature:          A(          in


                                                   Audix Technology (Shenthen) Co., Ltd.    Report No. ACS—F19044 page 3 of 28


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



       1. SUMMARY OF STANDARDS AND RESULTS
           1.1.Description of Standards and Results
               The EUT has been tested according to the applicable standards as referenced below.
                                             EMISSION
             Description of Test Item                   Standard                          Results
                                                 FCC Part 15C: 15.207
        Conducted Emission Test                                                             N/A
                                                  ANSI C63.10: 2013
                                               FCC Part 15C: 15.231(b)
        Radiated Emission Test                                                             PASS
                                                 ANSI C63.10: 2013

        Stop Transmitting Time Test           FCC Part 15C: 15.231(a)(1)                   PASS


        Cease Time After Activation           FCC Part 15C: 15.231(a)(2)                   PASS

                                                 FCC Part 15C: 15.207
        20 dB Bandwidth Test                                                               PASS
                                                  ANSI C63.10: 2013

        N/A is an abbreviation for Not Applicable.




                                              Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 4 of 28


                                                   AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



       2. GENERAL INFORMATION
           2.1.Description of Device (EUT)
               Product            : Wireless Call Point Transmitter

               Model No.          : WCP-21

               FCC ID             : WNG-WCP-21

               Operation frequency : 922.5MHz

               Applicant          : Rondish Company Limited
                                    Unit G&H, 4/F, Block 1, Kwai Tak Ind. Ctr. 15-33 Kwai Tak
                                    St., Kwai Chung, N.T., Hong Kong

               Manufacturer       : Rondish Company Limited
                                    Unit G&H, 4/F, Block 1, Kwai Tak Ind. Ctr. 15-33 Kwai Tak
                                    St., Kwai Chung, N.T., Hong Kong

               Antenna Type &Gain : Antenna Type: Wire Antenna, -3dBi gain;

               Date of Test       : Feb.12~Apr.15,2019

               Date of Receipt    : Feb.01,2019

               Sample Type        : Prototype production




                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 5 of 28


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



        2.1. EUT Configuration and operation conditions for test

                            EUT



             (EUT: Wireless Call Point Transmitter)

        2.2.Test Facility
            Site Description
                                                    Audix Technology (Shenzhen) Co., Ltd.
            Name of Firm                        :   No. 6, Kefeng Road, Science & Technology Park,
                                                    Nanshan District , Shenzhen, Guangdong, China

                                                    Certificated by Industry Canada
            EMC Lab.                            :   Registration Number: IC 5183A-1
                                                    Valid Date: May.07, 2020

                                                    Certificated by DAkkS, Germany
                                                :   Registration No: D-PL-12151-01-00
                                                    Valid Date: Dec.07, 2021

                                                    Accredited by NVLAP, USA
                                                :   NVLAP Code: 200372-0
                                                    Valid Date: Mar.31, 2020

                                                    Certificated by FCC USA.
                                                :   Designation No.: CN5022
                                                    Valid Date: Mar.31, 2020
        2.3.Measurement Uncertainty (95% confidence levels, k=2)
                               Test Item                                   Uncertainty
                                                               4.0dB(30~200MHz, Polarization: H)
              Uncertainty for Radiation Emission test          4.0dB(30~200MHz, Polarization: V)
                          in 3m chamber                        4.4dB(200M~1GHz, Polarization: H)
                                                               4.4dB(200M~1GHz, Polarization: V)
                                                                  5.0dB (1~6GHz, Distance: 3m)
             Uncertainty for Radiation Emission test in
                                                                 5.4dB (6~18GHz, Distance: 3m)
                            3m chamber
                                                               5.4dB (Above 18GHz, Distance: 3m)
                Uncertainty for Radiated Spurious
                                                                                      3.6dB
                  Emission test in RF chamber
               Uncertainty for Conduction Spurious
                                                                                      2.0dB
                           emission test
                Uncertainty for Output power test                                 0.8dB
                 Uncertainty for Bandwidth test                                   83kHz
                  Uncertainty for DC power test                                   0.1 %
              Uncertainty for test site temperature and                           0.6℃
                              humidity                                             3%


                                              Audix Technology (Shenzhen) Co., Ltd.    Report No. ACS-F19044 page 6 of 28


                                                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21


   3. POWER LINE CONDUCTED EMISSION TEST
       According to Paragraph (c) of FCC Part 15 section 15.231, Tests to demonstrate compliance with
       the conducted limits are not required for devices which only employ battery power for operation
       and which do not operate from the AC power lines or contain provisions for operation while
       connected to the AC power lines.




                                             Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 7 of 28


                                                    AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



       4. RADIATED EMISSION TEST
           4.1.Test Equipment
               Frequency range: 30~1000MHz
                                                                                                            Cal.
Item      Equipment         Manufacturer          Model No.              Serial No.         Last Cal.
                                                                                                          Interval
 1.        3#Chamber             AUDIX         N/A         N/A                              Jun.19,18      1 Year
 2.     Signal Analyzer     Rohde & Schwarz  FSV30        104050                            Apr.23,18      1 Year
 3.    EMI Test Receiver    Rohde & Schwarz   ESR7        101547                            Apr.23,18      1 Year
 4.         Amplifier              HP         8447D     2648A04738                          Apr.23,18      1 Year
       Tri-log-Broadband
 5.                            Schwarzbeck  VULB 9168       710                             Aug.22,18 1 Year
            Antenna
 6.        NSA Cable       HUBER+SUHNER CFD400NL-LW        No.3                             Dec.01,18      1 Year
 7.      Coaxial Switch          Anritsu     MP59B      6201397222                          Apr.23,18      1 Year
 8.      Test Software           AUDIX          e3    6.2009-5-21a(n)                         N/A           N/A
Note: N/A means Not applicable.

             Frequency range: above 1000MHz
                                                                                                            Cal.
Item      Equipment        Manufacturer           Model No.             Serial No.          Last Cal.
                                                                                                          Interval
 1.       3#Chamber             AUDIX           N/A         N/A                            May.17,18       1 Year
 2.     Signal Analyzer    Rohde & Schwarz    FSV30        104050                          Apr.23,18       1 Year
 3.      Horn Antenna            ETC        MCTD 1209  DRH15F03007                         May.30,18       1 Year
 4.        Amplifier            Agilent       83017A    MY53270084                         Oct.14,18       1 Year
 5.        RF Cable           Hubersuhner  SUCOFLEX106    505239/6                         Apr.23,18       1 Year
 6.      Test Software          AUDIX            e3    6.2009-5-21a(n)                       N/A            N/A
Note: N/A means Not applicable.




                                           Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 8 of 28


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



           4.2.Block Diagram of Test Setup
             For frequency range 30MHz-1000MHz


                                            Semi-anechoic 3m Chamber

                           ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                                           3m


                                                            EUT


                                                                                               0.8m
                                                                  TURN TABLE
                            2.0m(L)*1.0m(W)*0.8m(H)              (FIBRE GLASS)




         Coaxial Switch      AMP       Spectrum Analyzer            PC System


             Receiver


             For frequency range above 1GHz


                                     Semi-anechoic 3m Chamber
                            ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS




                                         3m                  EUT
                                   (Reference Point)


                              1.0m(L)*1.0m(W)*1.5m(H)              TURN TABLE
                                                                                              1.5m
                                 ABSORBER                            (Styrene)
                                 (30cm maximum)

                                                       (30cm)

                             AMP        Spectrum Analyzer            PC System




                                            Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 9 of 28


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21


           4.3.Radiated Emission Limit
               All emanations from a Class B computing devices or system, including any network of
               conductors and apparatus connected thereto, shall not exceed the level of field strengths
               specified below:
                      Fundamental                Field Strength of     Field Strength of Spurious
                    Frequency(MHz)                 Fundamental                  emissions
                          922.5             QP:81.94dBuV/m at 3m AV:61.94dBuV/m at 3m
                                            distance                   distance (Above 1GHz)
                                                                       PK:81.94dBuV/m at 3m
                                                                       distance (Above 1GHz)
                                                                       QP:61.94dBuV/m at 3m
                                                                       distance (Below 1GHz)
              Note: The spurious emissions appearing within the frequency band listed in 15.205
                   Shall also comply with limits shown in section 15.209
            4.4.EUT Configuration on Test
                The following equipment are installed on Radiated Emission Test to meet the
                commission requirements and operating regulations in a manner which tends to
                maximize its emission characteristics in normal application.
            4.5.Operating Condition of EUT
                4.5.1.Setup the EUT and simulator as shown as Section 4.2.
                4.5.2.Turn on the power of all equipments.
                4.5.3.Let EUT work in Tx mode.
            4.6.Test Procedure
                The EUT and its simulators are placed on a turn table, which is 0.8 meter high above
                ground. The turn table can rotate 360 degrees to determine the position of the maximum
                emission level. The EUT is set 3 meters away from the receiving antenna, which is
                mounted on a antenna tower. The antenna can be moved up and down between 1 meter
                and 4 meters to find out the maximum emission level. Broadband antenna (calibrated
                bilog antenna) is used as receiving antenna. Both horizontal and vertical polarization of
                the antenna is set on Test. In order to find the maximum emission levels, all of the
                interface cables must be manipulated according to ANSI C63.10-2013 on radiated
                emission Test.
                During the pretest the EUT was rotated through three orthogonal axes to determine the
                attitude that maximizes the emissions.
                After that the EUT was manually handled to find the orientation that has the maximum
                emission, which is the orientation show in the test setup photos.
                The bandwidth of the EMI test receiver (R&S ESR7) is set at 120kHz for frequency
                range from 30MHz to 1000MHz.
                The bandwidth of the Spectrum’s RBW is set at 1MHz and VBW is set at 3MHz for
                peak emissions measurement above 1GHz
            4.7.Radiated Emission Test Results
                PASS.




                                            Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 10 of 28


bate: 13       Fie: 2010 Report DataRiRondshiacsmoniozis (15)
 100 Level uim                                                                 bate: z00osar




                                                                          rec as2sh 2500




  *                  ze             ns               on                 sos.             on
                                        Frequency Oy
       size no.       3m Chanber                   bata no.      13
       Dis. / Ans.    am cors vuusszss—710         Ane. po.      nontzoumit
       pamie          ree as.2s1 sze.s or
       Env. / o.      2s.3r0/s5%                   Enginees      Andy
       zur            Wiretess Cali Point transmitters
       Pover rating : Do 3¥
       Test moge      Tx noas
                      wnucrezs

                    ane. canie         Ensssion
 wo.       Peeq.   Pactor Loss Reading Level    Limito:       Margin    Remark
         gre       (ab/m (a) (dowt) (abaw/ag (abuw/a)          (a9)
 10      anlaso     zo.so  o.ss  ouor anlas     40.00         anler     or
 20     assleso    anao   css    suerl erles    an uo         anler     o
 3      ava.seo     2s.so ales    aso eelss      as.oo        anlor     o
 a      see.3z0    elas   aure    oura anuar    as.oo         dsuss     o
 s      srzur00     reles ouas    ouse s2.00    as.co         r.00      or
 6      sze.s00    rouze   a.39 seuze mlso      onloe         a0.04     or
       Revazks: 1. Emiasion Level= Antenna Factor + Cable Loss + Reading«
                2. The eniasion levels that are 204 belov the official
                   Aimit are not reported.


                               AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21




                    Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 12 of 28


Datea          Fie: E22010 Report DataRRonashacsrconotoncems (0)
 100 Level utm



                                                                                  rcopnrt ispent
                                                                                              se

                                              i                                    rcopni1se av
 so           I            1                          I       I       1       I         |—ap
                                                                   rrranthranpsnmntcaomenie




      ooo             zom.                  zo.               sun.           sen.            Toomo
                                                 Frequency ts
       site no.       :        9m Chamber                   bata no. : 4
       pis. / ame.             on 2018 nerai209—2007        Ane. or. : norfzoumit
       kamic                   ree rart iso reas
       Eav. / me.     on       assarc/sse                   Enginess o+ anay
       sor                     Wizeless Call Poine transnitters
       Pover rasing   :        bo 2y
       Test itode     :        Tx tode
                               whnsucr—21


                     Ane. capie           Emiasion
 No.      Preq.     Factor loss Reading Level      Linite          Margin     Resark
         gite)      (db/m)  (ab) (dbuw) (dBw/ (cowW/               (dB)
 1.    ases.000     as.so  a.se os.26 92.70.       $4.00.          21.30      Average
 2.    rsa8.000     recso  2.54.. a5.99.. An277..74.00..           92.230..   Peak
 3.    seer.000     s0.07  s.s% 49.96.50.93        5400.             3.07     Average
 a.    sser.000     so.or  susn woues Se.de        74.00           21270      Peak
 5.    4508.000     sz.sr  3.99 q4.05 50.6%..      5400.             3.99     Average
 s     asos.000     secer  s.90 aav Seude          74.00            23.08     Peak
                  1. Enission Level= Antenna Factor + Cable Loss + Reading.
                  2. The emission levels that are 2040 below the official
                     Aimit are not reported.


Date:s         He: E22010 Report DataFRonashacsroononeems (@)
 100 Level uim



                                                                                  reopart ispenic
                                                                                              sn

                                                                                    recpaitr 1se av
 so           ;            }          }               lbog—1             |        ;       k con
                                                                             ronatincomcaprinces




      ooo             zom.                  zo.               sun.           sen.              Toomo
                                                 Frequency ts
       site no.       :        9m Chamber                   bata no. : 3
       pis. / ame.             on 2018 nerai209—2007        Ane. por. : vermicat
       eo                      ree rart isreas
       Env. / me.     on       assarc/sse                   Enginess o+ anay
       sor                     Wizeless Call Poine transnitters
       Pover rasing   i        bo o
       Test itode     :        Tx tode
                               whnsucr—21


                     Ane. capie         Emiasion
 No.      Preq.     Factor loss Reading Level                Linite    Margin   Resark
         gite)      (db/m) (ab) (dbuw) (dBw/                (cowW/     (dB)
 1.    sesn000      so.ar  s.sr s9.3n 4188                   $4.00      4242    Average
 2.    seer.000     so.or  susr as.3% a7.68                  74.00..   26202    Peak
 3.    «s08.000     sz.sr  3.99 44.98 50.43                  5400.       3.07   Average
 a.    4s08.000     szuer  3.99. asu90 Si274                 74.00..   22.25    Peak
 5.    sese.000     ae.sr  4200 20.59 30.32..                5400.      45.60   Average
 s     sess.000     sacer  «se 90.59 a7.32..                 74.00      2660    Peak
                  1. Enission Level= Antenna Factor + Cable Loss + Reading.
                  2. The emission levels that are 2040 below the official
                     Aimit are not reported.


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



       5. STOP TRANSMITTING TIME TEST
           5.1. Test Equipment
     Item  Equipment   Manufacturer            Model No.          Serial No. Last Cal. Cal. Interval
       1. EMC Analyzer   Agilent               N9030A            MY51380221 Sep.08,18    1 Year
           5.2. Limit
                  Per Part 15.231(a)(1): A manually operated transmitter shall employ a switch that will
                  automatically deactivate the transmitter within not more than 5 seconds of being
                  released.
           5.3. Test Results
      EUT: Wireless Call Point Transmitter
      M/N: WCP-21
      Test Date: 2019-04-15      Pressure: 101.2±1.0 kpa               Humidity: 52.1±3.0%
      Tested By: Lynn            Test Site: RF site                    Temperature:22.9±0.6℃

        Frequency             Test          Stop Transmitting Time                         Limit
          (MHz)               Mode                    (s)                                   (s)
          922.5                Tx                       3.96                                <5
      Conclusion:PASS




                                             Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 15 of 28


                                                         AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



       6. CEASE TIME AFTER ACTIVATION TEST
           6.1. Test Equipment
     Item  Equipment   Manufacturer            Model No.           Serial No. Last Cal. Cal. Interval
       1. EMC Analyzer   Agilent               N9030A             MY51380221 Sep.08,18    1 Year
           6.2. Limit
                  Per Part 15.231(a)(2): A transmitter activated automatically shall cease transmission
                  within 5 seconds after activation.
           6.3. Test Result
      EUT: Wireless Call Point Transmitter
      M/N: WCP-21
      Test Date: 2019-04-15      Pressure: 101.2±1.0 kpa                Humidity: 52.1±3.0%
      Tested By: Lynn            Test Site: RF site                     Temperature:22.9±0.6℃

                                                   Cease Time After
        Frequency             Test                                                             Limit
                                                      Activation
          (MHz)               Mode                                                              (s)
                                                          (s)
          922.5                Tx                          4.43                                 <5
      Conclusion:PASS




                                              Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 16 of 28


                                                          AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21


         7.   20 DB BANDWIDTH TEST
         7.1. Test Equipment
  Item        Equipment      Manufacturer       Model No.             Serial No.           Last Cal.     Cal. Interval
              PXA Signal
  1.                            Agilent          N9030A             MY51380221            Sep.08,18         1Year
               Analyzer
  2.          Attenuator        Agilent           8491B             MY39269170            Oct.14,18         1 Year
  3.           RF Cable      Hubersuhner     SUCOFLEX106               505239/6           Apr.23,18         1 Year
         7.2. Limit
              The bandwidth of the emission shall be no wider than 0.5% of the center frequency.
         7.3. Test Results
       EUT: Wireless Call Point Transmitter
       M/N: WCP-21
       Test Date: 2019-03-11         Pressure: 101.2±1.0 kpa                  Humidity: 52.1±3.0%
       Tested By: Lynn               Test Site: RF site                       Temperature:22.9±0.6℃

         Frequency              Test               -20dB Bandwith                             Limit
           (MHz)                Mode                   (kHz)                                 (MHz)
            922.5                Tx                     49.55                               <4.6125
       Conclusion:PASS




                                               Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 17 of 28


                                                          AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



  8. ANTENNA REQUIREMENT

      RESULT           :      PASS

      Test Date       :       Feb.12~Apr.15,2019

      Test standard   :       FCC Part 15.231

      Limit               :   the use of antennas with directional gains that do not exceed 6 dBi


      According to the manufacturer declared, the EUT has an Wire antenna, the directional gain
      of antenna is -3dBi, and the antenna connector is designed with permanent attachment and no
      consideration of replacement. Therefore the EUT is considered sufficient to comply the provision.




                                               Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 18 of 28


                                                    AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



  9. RADIO FRREQUENCY EXPOSURE COMPLIANCE

      RESULT          : PASS

      Test standard   : FCC KDB Publication 447498 D01 V06

      Since maximum peak output power of the transmitter is<16mW, i.e.0.000007432780mW<16mW,
      hence the EUT is excluded from SAR evaluation according to FCC KDB Publication 447498 D01:
      General RF Exposure Guidance V06.




                                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 19 of 28


                                    AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-WCP-21



  10. DEVIATION TO TEST SPECIFICATIONS
      [NONE]




                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19044 page 20 of 28