Test Report

FCC ID: WNG-TXP-11

Test Report

Download: PDF
FCCID_4381292

                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11




                    FCC PART 15C TEST REPORT FOR CERTIFICATION
                                     On Behalf of

                                Rondish Company Limited

                                    Pendent Transmitter

                                           TXP-11

                                   FCC ID: WNG-TXP-11




                           Prepared for : Rondish Company Limited
                                          Unit G&H, 4/F, Block 1, Kwai Tak Ind. Ctr. 15-33 Kwai
                                          Tak St., Kwai Chung, N.T., Hong Kong




                           Prepared By : Audix Technology (Shenzhen) Co., Ltd.
                                         No. 6, Kefeng Road, Science & Technology Park,
                                         Nanshan District , Shenzhen, Guangdong, China

                                         Tel: (0755) 26639496




                           Report Number :        ACS-F19093
                           Date of Test   :       May.10~Jun.05,2019
                           Date of Report :       Jun.24,2019




                                           Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 1 of 28


                                                                                      AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11


                                                      TABLE OF CONTENTS

    Description                                                                                                                                        Page

   1.    SUMMARY OF STANDARDS AND RESULTS ............................................................. 4
         1.1.      Description of Standards and Results ...................................................................................... 4
   2.    GENERAL INFORMATION ............................................................................................ 5
         2.1.      Description of Device (EUT)................................................................................................... 5
         2.1.      EUT Configuration and operation conditions for test ............................................................. 6
         2.2.      Test Facility ............................................................................................................................. 6
         2.3.      Measurement Uncertainty (95% confidence levels, k=2) ........................................................ 6
   3.    POWER LINE CONDUCTED EMISSION TEST .......................................................... 7
   4.    RADIATED EMISSION TEST ......................................................................................... 8
         4.1.      Test Equipment ........................................................................................................................ 8
         4.2.      Block Diagram of Test Setup .................................................................................................. 9
         4.3.      Radiated Emission Limit ....................................................................................................... 10
         4.4.      EUT Configuration on Test ................................................................................................... 10
         4.5.      Operating Condition of EUT ................................................................................................. 10
         4.6.      Test Procedure ....................................................................................................................... 10
         4.7.      Radiated Emission Test Results............................................................................................. 10
   5.    STOP TRANSMITTING TIME TEST ........................................................................... 15
         5.1.      Test Equipment ...................................................................................................................... 15
         5.2.      Limit ...................................................................................................................................... 15
         5.3.      Test Results............................................................................................................................ 15
   6.    CEASE TIME AFTER ACTIVATION TEST ............................................................... 16
         6.1.      Test Equipment ...................................................................................................................... 16
         6.2.      Limit ...................................................................................................................................... 16
         6.3.      Test Result ............................................................................................................................. 16
   7.    20 DB BANDWIDTH TEST ............................................................................................ 17
         7.1. Test Equipment ...................................................................................................................... 17
         7.2. Limit ...................................................................................................................................... 17
         The bandwidth of the emission shall be no wider than 0.25% of the center frequency. .................. 17
         7.3. Test Results............................................................................................................................ 17
   8.    ANTENNA REQUIREMENT ......................................................................................... 18
   9.    RADIO FRREQUENCY EXPOSURE COMPLIANCE ............................................... 19
   10.   DEVIATION TO TEST SPECIFICATIONS ................................................................. 20
   11.   PHOTOGRAPH OF TEST .............................................................................................. 21
         11.1. Photos of Radiated Emission Test ......................................................................................... 21
   12.   PHOTOGRAPH OF EUT ................................................................................................ 22




                                                                         Audix Technology (Shenzhen) Co., Ltd.              Report No. ACS-F19093 page 2 of 28


                      ®
 AU D IX                                                       AUDIX Technology(Shenzhen) Co., Ltd.
FCC ID:WNG—TXP—11



                              TEST REPORT CERTIFICATION
     Applicant            :   Rondish Company Limited

     Manufacturer         *   Rondish Company Limited
     Product              *   Pendent Transmitter
     FCCID                _   WNG—TXP—11
                              (A)Model No.               : TXP—11
                              (B)Power Supply       _:     DC3V
                              (C)Test Voltage       _:     DC3V
     Tested for comply with:
     FCC CFR47 Part 15 Subpart C

     Test procedure used:
     ANSI C63.10: 2013

     The device described above is tested by AUDIX TECHNOLOGY (SHENZHEN) CO., LTD. to
     confirm comply with all the FCC Part 15 Subpart C requirements.

     The test results are contained in this test report and AUDIX TECHNOLOGY (SHENZHEN) CO.,
     LTD. is assumed full responsibility for the accuracy and completeness of these tests. This report
     contains data that are not covered by the NVLAP accreditation. Also, this report shows that the
     Equipment Under Test (EUT) is to be technically compliant with the FCC requirements.

     This report applies to above tested sample only. This report shall not be reproduced in part without
     written approval of AUDIX TECHNOLOGY (SHENZHEN) CO., LTD.

     The report must not be used by the client to claim product certification, approval, or endorsement by
     NVLAP, NIST, or any agency of the federal government.

     Date of Test :       May.10~Jun.05,2019             Report of date:                    Jun.24,2019




     Prepared by :        B V(M/CZ                       Reviewed by :
                      Brave Zhang / Asgistant

                                                  mo f*##& (K#®) 4#1ma :
                                         AUD‘#             Audix Technology (SLcuzhen) Co., Ltd.
                                                           EMC # M # c q nor
                                                Stamp only for EMC Dept. Report

     Approved & Authorized Signer :             Signature:                   L

                                                  Audix Technology (Shenthen) Co., Ltd.    Report No. ACS—F19093 page 3 of 28


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



       1. SUMMARY OF STANDARDS AND RESULTS
           1.1.Description of Standards and Results
               The EUT has been tested according to the applicable standards as referenced below.
                                             EMISSION
             Description of Test Item                   Standard                           Results
                                                 FCC Part 15C: 15.207
        Conducted Emission Test                                                              N/A
                                                  ANSI C63.10: 2013
                                               FCC Part 15C: 15.231(b)
        Radiated Emission Test                                                              PASS
                                                 ANSI C63.10: 2013
                                                     FCC Part 15C:
        Stop Transmitting Time Test                                                         PASS
                                                      15.231(a)(1)
                                                     FCC Part 15C:
        Cease Time After Activation                                                         PASS
                                                      15.231(a)(2)

        20 dB Bandwidth Test                   FCC Part 15C: 15.231(c)                      PASS


        N/A is an abbreviation for Not Applicable.




                                               Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 4 of 28


                                                  AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



       2. GENERAL INFORMATION
           2.1.Description of Device (EUT)
               Product           : Pendent Transmitter

               Model No.         : TXP-11

               FCC ID            : WNG-TXP-11

               Operation frequency : 433.92MHz

               Applicant         : Rondish Company Limited
                                   Unit G&H, 4/F, Block 1, Kwai Tak Ind. Ctr. 15-33 Kwai Tak
                                   St., Kwai Chung, N.T., Hong Kong

               Manufacturer      : Rondish Company Limited
                                   Unit G&H, 4/F, Block 1, Kwai Tak Ind. Ctr. 15-33 Kwai Tak
                                   St., Kwai Chung, N.T., Hong Kong

               Antenna Type      : Antenna Type: PCB Antenna, 0dBi gain.
               &Gain

               Date of Test      : May.10~Jun.05,2019

               Date of Receipt   : Apr.12,2019

               Sample Type       : Prototype production




                                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 5 of 28


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



         2.1. EUT Configuration and operation conditions for test

                             EUT



              (EUT: Pendent Transmitter)

         2.2.Test Facility
             Site Description
                                                     Audix Technology (Shenzhen) Co., Ltd.
             Name of Firm                       :    No. 6, Kefeng Road, Science & Technology Park,
                                                     Nanshan District , Shenzhen, Guangdong, China

                                                     Certificated by Industry Canada
             EMC Lab.                           :    Registration Number: IC 5183A-1
                                                     Valid Date: May.07, 2020

                                                     Certificated by DAkkS, Germany
                                                :    Registration No: D-PL-12151-01-00
                                                     Valid Date: Dec.07, 2021

                                                     Accredited by NVLAP, USA
                                                :    NVLAP Code: 200372-0
                                                     Valid Date: Mar.31, 2020

                                                     Certificated by FCC USA.
                                                :    Designation No.: CN5022
                                                     Valid Date: Mar.31, 2020
         2.3.Measurement Uncertainty (95% confidence levels, k=2)
                                Test Item                                  Uncertainty
                                                               4.0dB(30~200MHz, Polarization: H)
              Uncertainty for Radiation Emission test          4.0dB(30~200MHz, Polarization: V)
                          in 3m chamber                        4.4dB(200M~1GHz, Polarization: H)
                                                               4.4dB(200M~1GHz, Polarization: V)
                                                                  5.0dB (1~6GHz, Distance: 3m)
             Uncertainty for Radiation Emission test in
                                                                 5.4dB (6~18GHz, Distance: 3m)
                            3m chamber
                                                               5.4dB (Above 18GHz, Distance: 3m)
                Uncertainty for Radiated Spurious
                                                                                   3.6dB
                   Emission test in RF chamber
               Uncertainty for Conduction Spurious
                                                                                   2.0dB
                           emission test
                Uncertainty for Output power test                                  0.8dB
                 Uncertainty for Bandwidth test                                    83kHz
                  Uncertainty for DC power test                                    0.1 %
              Uncertainty for test site temperature and                            0.6℃
                              humidity                                              3%


                                               Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 6 of 28


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11


   3. POWER LINE CONDUCTED EMISSION TEST
       According to Paragraph (c) of FCC Part 15 section 15.231, Tests to demonstrate compliance with
       the conducted limits are not required for devices which only employ battery power for operation
       and which do not operate from the AC power lines or contain provisions for operation while
       connected to the AC power lines.




                                              Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 7 of 28


                                                    AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



        4. RADIATED EMISSION TEST
           4.1.Test Equipment
               Frequency range: 30~1000MHz
                                                                                                           Cal.
 Item     Equipment         Manufacturer        Model No.              Serial No.          Last Cal.
                                                                                                         Interval
  1.       3#Chamber             AUDIX        N/A          N/A                             Jun.19,18      1 Year
  2.    Signal Analyzer    Rohde & Schwarz  FSV30        104050                            Apr.14,19      1 Year
  3.   EMI Test Receiver Rohde & Schwarz     ESR7        101547                            Apr.14,19      1 Year
  4.        Amplifier             HP         8447D     2648A04738                          Apr.14,19      1 Year
       Tri-log-Broadband
  5.                       SCHWARZBECK     VULB 9168       710                            Aug.22,18 1 Year
            Antenna
  6.       NSA Cable       HUBER+SUHNER CFD400NL-LW       No.3                             Dec.01,18 1 Year
  7.     Coaxial Switch          Anritsu    MP59B      6201397222                          Apr.14,19 1 Year
  8.     Test Software           AUDIX         e3    6.2009-5-21a(n)                         N/A      N/A
 Note: N/A means Not applicable.

              Frequency range: above 1000MHz
                                                                                                           Cal.
 Item      Equipment        Manufacturer        Model No.              Serial No.          Last Cal.
                                                                                                         Interval
 1.        3#Chamber             AUDIX           N/A         N/A                          May.17,18       1 Year
 2.      Signal Analyzer    Rohde & Schwarz    FSV30        104050                        Apr.14,19       1 Year
 3.       Horn Antenna            ETC        MCTD 1209  DRH15F03007                       May.30,18       1 Year
 4.         Amplifier            Agilent       83017A    MY53270084                       Oct.14,18       1 Year
 5.         RF Cable          Hubersuhner   SUCOFLEX106    505238/6                       Apr.13,19       1 Year
 6.       Test Software          AUDIX            e3    6.2009-5-21a(n)                     N/A            N/A
 Note: N/A means Not applicable.




                                           Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 8 of 28


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



           4.2.Block Diagram of Test Setup
              For frequency range 30MHz-1000MHz


                                              Semi-anechoic 3m Chamber

                            ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
                                             3m


                                                             EUT


                                                                                                0.8m
                                                                   TURN TABLE
                             2.0m(L)*1.0m(W)*0.8m(H)              (FIBRE GLASS)




          Coaxial Switch      AMP       Spectrum Analyzer            PC System


             Receiver


              For frequency range above 1GHz


                                      Semi-anechoic 3m Chamber
                             ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS




                                          3m                 EUT
                                    (Reference Point)


                              1.0m(L)*1.0m(W)*1.5m(H)              TURN TABLE
                                                                                               1.5m
                                 ABSORBER                            (Styrene)
                                 (30cm maximum)

                                                        (30cm)

                              AMP        Spectrum Analyzer           PC System




                                              Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 9 of 28


                                                       AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11


           4.3.Radiated Emission Limit
               All emanations from a Class B computing devices or system, including any network of
               conductors and apparatus connected thereto, shall not exceed the level of field strengths
               specified below:
                      Fundamental                Field Strength of     Field Strength of Spurious
                    Frequency(MHz)                 Fundamental                  emissions
                         433.92             QP:80.83dBuV/m at 3m AV:60.83dBuV/m at 3m
                                            distance                   distance (Above 1GHz)
                                                                       PK:80.83dBuV/m at 3m
                                                                       distance (Above 1GHz)
                                                                       QP:60.83dBuV/m at 3m
                                                                       distance (Below 1GHz)
              Note: The spurious emissions appearing within the frequency band listed in 15.205
                   Shall also comply with limits shown in section 15.209
            4.4.EUT Configuration on Test
                The following equipment are installed on Radiated Emission Test to meet the
                commission requirements and operating regulations in a manner which tends to
                maximize its emission characteristics in normal application.
            4.5.Operating Condition of EUT
                4.5.1.Setup the EUT and simulator as shown as Section 4.2.
                4.5.2.Turn on the power of all equipments.
                4.5.3.Let EUT work in Tx mode.
            4.6.Test Procedure
                The EUT and its simulators are placed on a turn table, which is 0.8 meter high above
                ground. The turn table can rotate 360 degrees to determine the position of the maximum
                emission level. The EUT is set 3 meters away from the receiving antenna, which is
                mounted on a antenna tower. The antenna can be moved up and down between 1 meter
                and 4 meters to find out the maximum emission level. Broadband antenna (calibrated
                bilog antenna) is used as receiving antenna. Both horizontal and vertical polarization of
                the antenna is set on Test. In order to find the maximum emission levels, all of the
                interface cables must be manipulated according to ANSI C63.10-2013 on radiated
                emission Test.
                During the pretest the EUT was rotated through three orthogonal axes to determine the
                attitude that maximizes the emissions.
                After that the EUT was manually handled to find the orientation that has the maximum
                emission, which is the orientation show in the test setup photos.
                The bandwidth of the EMI test receiver (R&S ESR7) is set at 120kHz for frequency
                range from 30MHz to 1000MHz.
                The bandwidth of the Spectrum’s RBW is set at 1MHz and VBW is set at 3MHz for
                peak emissions measurement above 1GHz
                This device is pulse modulated; a duty cycle factor was used to calculate average level
                based measured peak level.
            4.7.Radiated Emission Test Results
                PASS.


                                             Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 10 of 28


Dates      He: E22010 Report DataFfRonashcsmokie.re.emo ()
 .Loz anim                                                                     pateczoroosm




 is                                                                     too stzmiiszaz on
                                                                                       m

                                             [

  ®%                   ze              vs.              on           Ca                 on
                                        Frequency (itio
       size no.       3m Chanber                     baza no. i s
       Dis. / Ans.    on 2010 vtsorse—70             Ane. po. nontzoumit
       pamie          ree as.ess aso.se or
       Emv. / ms.     as.ono/s5+                     Enginee    Andy
       zur            Pendent Teansnister      MiiTiPoi1
       Pover rating : Do 37
       Test moge      Tx noas

                      ane. canie         Emssion
 wo.       Preq.     Fector loss Reading Level   Limito: Margin        Renark
         grre .      (abe (ab) (duw) (deu/ag (abww/a) (a9)
 10     ass.seo       as.eo alas ~ouer couae     asuso 2o.00           or
 a      ass.seo       melss  s.e0 asuso mds      soues     Suso        or
 3      eee.370      re.ss  auon couse     seurr asuoo    aoues        or
                   1. Entssion Level: Antemna Factor + Cable Loss + Reading.
                   2. The emission levels that are 204 belov the official
                      Aimit are not reported.


                              AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11




                    Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 12 of 28


                            He:F:2019 ReporttEMbiincstoomoot.cis (2)
                       m                                                                parerzot.0s.10
      son
      sea                                                                          ce pai15c PeRK
      700                                                                                         in
      se0                          :                                                   Ece pait 15c A
      soo
                        i
      ano
      soo
      200
      100
            oo               To:               To:              To               sov.              sove
                                                  Frequency (itle
       site no.        an Chasber              basa no.    2
       pss. / Ane. oc am 2or8 mem1209—3007      ame. pou. : nontzonmat
       bimie           ree rant is reax         rre
       Bav. / ms. c 2sne/snn                    Enginess : carey
       m               rendent Transmscter Mirtiz—i1
       Pover: rating : bo 1050
       Tess toas       T% toae



                          Ane. canie m              Ensssson
No.          Freq.       astor: Loss tector Reading Level Limits: argin Resark
             gre         (abe (ae)    (ab) (abw) (abww/ag (abww/a) (a9)
 10         anas.0o     gecas          uts    aouso    4650         Anuen    74.00.      92249    Peak
 a          eave.oo      av.sa         o.es   ozltr    39.35        94.92.   54.00.—     19.08.   Average
 3          eave.oo      av.sa         oes    orltr    soas         ssu76    74.00       18.24.   Peak
 a          asos.00     ee.as           o9r   orlss    as.0e        41275    74.00       32.25.   Peak
       renazks           Eniasion Level= Antenna Factor + Cable Loss + Reading
                         ~Amp Factor
                      2« The emission levels that are 204 belov the official
                         Aimit are not reported.


  Datect          rie:Fr2oto Report iiibiincstoonoo.ems (2)
    .otevet @ewim                                                          parerzot.0s.10
       son
       seol                                                             iccomer jsc perw
       700                                                                           sn
       se0                                                                reemgr ise ay
       soo                                                                         —san
       anol
       s0o
       200
       100
              oo             To:      To:              To             sov.            sove
                                         Frequency tittn
         site no.        an Chasber                   baea no.     1
         pss. / Ane.     am 2or8 mem1209—3007           ame. pou. : vertican
         bimie           ree rant is reax               rre
         Bav. / ms. c 2sne/snn                          Enginess : carey
         m               Pendnt Transmstter      Mintiz—i
         Pover: rating : bo 1050
         Tess toas       T% toae



                           Ane.    canie m             Ensssson
wo.            Freq.      Fector   Loss fector meading Level Linits: Margin Resark
               gre        (abe     (ae)   (ab) (abw) (abww/ag (abww/a) (a9)
 10—          as00.00     2s.os    ouse an.so   asls8 am.ee 24.00 asla2 reak
 a            eanoloo      aviss    oles arlor  aecee anuer 26.00 30.39. reak
                           Eniasion Level Anterna Factor + Cable Loss + Reading
                           ~Amp Factor
                        2« The emission levels that are 204 belov the official
                           Aimit are not reported.


                                                             AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



      5.      STOP TRANSMITTING TIME TEST
              5.1. Test Equipment
                                                                                                              Cal.
     Item       Equipment        Manufacturer      Model No.            Serial No.         Last Cal.
                                                                                                            Interval
       1.     EMC Analyzer          Agilent         N9030A           MY51380221 Sep.08,18                    1 Year
              5.2. Limit
                      Per Part 15.231(a)(1): A manually operated transmitter shall employ a switch that will
                      automatically deactivate the transmitter within not more than 5 seconds of being
                      released.
              5.3. Test Results
      EUT: Wireless Call Point transmitters
      M/N: WCP-11
      Test Date: 2019-06-05      Pressure: 101.2±1.0 kpa                   Humidity: 52.1±3.0%
      Tested By: Lynn            Test Site: RF site                        Temperature:22.9±0.6℃

            Frequency             Test           Stop Transmitting Time                         Limit
              (MHz)               Mode                     (s)                                   (s)

             433.92                 Tx                      2.490                                 <5

      Conclusion:PASS




                                                  Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 15 of 28


                                                            AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



      6.     CEASE TIME AFTER ACTIVATION TEST
             6.1. Test Equipment
                                                                                                             Cal.
     Item      Equipment        Manufacturer      Model No.            Serial No.         Last Cal.
                                                                                                           Interval
       1.    EMC Analyzer          Agilent         N9030A            MY51380221 Sep.08,18                   1 Year
             6.2. Limit
                     Per Part 15.231(a)(2): A transmitter activated automatically shall cease transmission
                     within 5 seconds after activation.
             6.3. Test Result
      EUT: Wireless Call Point Transmitter
      M/N: WCP-11
      Test Date: 2019-06-05      Pressure: 101.4±1.0 kpa                  Humidity: 52.7±3.0%
      Tested By: Lynn            Test Site: RF site                       Temperature:22.3±0.6℃

                                                     Cease Time After
        Frequency                Test                                                            Limit
                                                        Activation
          (MHz)                  Mode                                                             (s)
                                                            (s)
            433.92                Tx                         2.150                                 <5
      Conclusion:PASS




                                                 Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 16 of 28


                                                        AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



         7.   20 DB BANDWIDTH TEST
         7.1. Test Equipment
  Item        Equipment      Manufacturer     Model No.             Serial No.          Last Cal.     Cal. Interval
              PXA Signal
  1.                           Agilent         N9030A            MY51380221            Sep.08,18          1Year
               Analyzer
  2.          Attenuator       Agilent          8491B            MY39269170             Oct.14,18         1 Year
  3.           RF Cable      Hubersuhner    SUCOFLEX106             505239/6           Apr.13,19          1 Year
         7.2. Limit
              The bandwidth of the emission shall be no wider than 0.25% of the center
              frequency.
         7.3. Test Results
       EUT: Wireless Call Point Transmitter
       M/N: WCP-11
       Test Date: 2019-05-10         Pressure: 101.2±1.0 kpa                Humidity: 52.1±3.0%
       Tested By: Lynn               Test Site: RF site                     Temperature:22.9±0.6℃

         Frequency             Test             -20dB Bandwith                              Limit
           (MHz)               Mode                 (kHz)                                  (MHz)
           433.92               Tx                   49.99                                <1.0848
       Conclusion:PASS




                                             Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 17 of 28


                                                           AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



  8. ANTENNA REQUIREMENT
      RESULT           :      PASS

      Test Date       :       May.10~Jun.05,2019

      Test standard   :       FCC Part 15.231

      Limit               :   the use of antennas with directional gains that do not exceed 6 dBi


      According to the manufacturer declared, the EUT has an PCB antenna, the directional gain
      of antenna is 0dBi, and the antenna connector is designed with permanent attachment and no
      consideration of replacement. Therefore the EUT is considered sufficient to comply the provision.




                                                Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 18 of 28


                                                     AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11



  9. RADIO FRREQUENCY EXPOSURE COMPLIANCE
      RESULT          :   PASS

      Test standard   :   FCC KDB Publication 447498 D01 V06

      Since maximum peak output power of the transmitter is<10mW, i.e.0.0042mW<10mW, hence the
      EUT is excluded from SAR evaluation according to FCC KDB Publication 447498 D01: General
      RF Exposure Guidance V06.




                                          Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 19 of 28


                                    AUDIX Technology (Shenzhen) Co., Ltd.
FCC ID:WNG-TXP-11


  10. DEVIATION TO TEST SPECIFICATIONS
      [NONE]




                         Audix Technology (Shenzhen) Co., Ltd.   Report No. ACS-F19093 page 20 of 28



Document Created: 2019-07-23 14:04:47
Document Modified: 2019-07-23 14:04:47

© 2024 FCC.report