RF Exposure Report

FCC ID: WIGDT9660TBT

RF Exposure Info

Download: PDF
FCCID_3483726

                 Test Report No.: FS170608N004



                                    RF EXPOSURE REPORT
Applicant                        Shenzhen Everbest Machinery Industry Co., Ltd

                                 19th Building, 5th Region, Baiwangxin Industrial Park, SongBai Rd.,Baimang, Xili,
Address
                                 Nanshan, Shenzhen China


Manufacturer or
                                 Shenzhen Everbest Machinery Industry Co., Ltd
Supplier
                                 19th Building, 5th Region, Baiwangxin Industrial Park, SongBai Rd.,Baimang, Xili,
Address
                                 Nanshan, Shenzhen China

Product                          Digital Multimeter

Brand Name                       CEM

Model                            DT-9660T-BT

Additional Model &
                                 DT-9660, DT-9660B, DT-9660D, DT-9660T, DT-9661, DT-9662, DT-9663, DT-9664
Model Difference

Date of tests                    Jun. 09, 2017 ~ Jul. 08, 2017

     FCC Part 2 (Section 2.1093)
     KDB 447498 D01
     IEEE C95.1

CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                      Tested by Tom Chen                                                               Approved by Glyn He
              Project Engineer / EMC Department                                                     Supervisor/ EMC Department




                                                                                                             Date: Jul. 12, 2017
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or
identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the
information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our
negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue
within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the
report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or
non-compliance to the specification



                                                     No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                                     Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch
                                                     Guangdong 523942, China                                      Email: customerservice.dg@cn.bureauveritas.com
                                                                            Page 1 of 6                                                              Report Version 1


             Test Report No.: FS170608N004


                                          Table of Contents
   RELEASE CONTROL RECORD ................................................................................ 3
   1.       CERTIFICATION .............................................................................................. 4
   2.       RF EXPOSURE DEFINE ................................................................................. 5
   3.       CLASSIFICATION ........................................................................................... 5
   4.       SAR TEST EXCLUSION THRESHOLDS ........................................................ 6




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                         Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                           Page 2 of 6                                                   Report Version 1


             Test Report No.: FS170608N004



                               RELEASE CONTROL RECORD

    ISSUE NO.                REASON FOR CHANGE                                                      DATE ISSUED
    FS170608N004             Original release                                                       Jul. 12, 2017




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 3 of 6                                                    Report Version 1


             Test Report No.: FS170608N004



   1. CERTIFICATION

                       FCC ID:      WIGDT9660TBT
                  PRODUCT:          Digital Multimeter
             BRAND NAME:            CEM
                MODEL NO.:          DT-9660T-BT
                                    DT-9660, DT-9660B, DT-9660D, DT-9660T, DT-9661,
        ADDITIONAL NO.:
                                    DT-9662, DT-9663, DT-9664
                APPLICANT:          Shenzhen Everbest Machinery Industry Co., Ltd

              STANDARDS:            FCC Part 2 (Section 2.1093)

                                    KDB 447498 D01

                                    IEEE C95.1




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 4 of 6                                                    Report Version 1


             Test Report No.: FS170608N004


   2. RF EXPOSURE DEFINE
   The corresponding SAR Exclusion Threshold condition, listed below:

   1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
     mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
          f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation
          The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.
   2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold
     is determined according to the following:
     a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at
       100MHz to 1500 MHz
     b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤
       6 GHz
   3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
     a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by
       [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
     b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
       separation distances ≤ 50 mm.
     c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion
       cannot be applied, a KDB inquiry is required to determine SAR evaluation requirements for any
       test results to be acceptable.


   3. CLASSIFICATION
   The antenna of this product, under normal use condition, is at less than 20cm away
   from the body of the user. So, this device is classified as Portable Device.




                                     No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                     Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                     Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                      Page 5 of 6                                                    Report Version 1


             Test Report No.: FS170608N004


   4. SAR TEST EXCLUSION THRESHOLDS

   The tuned conducted Average Power (declared by client)

                                    Target                                  Lower                Upper
               Frequency                             Tolerance
                                    Power                                 Tolerance            Tolerance
                 (MHz)                                 (dBm)
                                    (dBm)                                   (dBm)                (dBm)
              2402-2480               -7                +-2                   -9                      -5


   The measured conducted Average Power

                                                Frequency                              Averaged Power
                Mode
                                                  (MHz)                                     (dBm)

           BT-LE (GFSK)                              2402                                      -6.21




   SAR Test Exclusion Thresholds


                          Maximum
                       source-based           Minimum                                      Limit for
      Frequency        time averaged         separation       Result       Limit for         10-g               Verdic
        (MHz)            conducted            distance        of Eq. 1     1-g SAR         extremity              t
                        output power            (mm)                                         SAR
                           (dBm)
                                                                                                               Exempt
      2402-2480                -5                5            0.0996           3.0              7.5             from
                                                                                                                SAR


   Conclusion

   Therefore this device complies with FCC’s RF radiation exposure limits for general population without
   SAR evaluation.




                                       No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8593 5656
Bureau Veritas Shenzhen Co., Ltd.
                                       Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch
                                       Guangdong 523942, China                         Email: customerservice.dg@cn.bureauveritas.com
                                                        Page 6 of 6                                                    Report Version 1



Document Created: 2017-07-14 14:06:53
Document Modified: 2017-07-14 14:06:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC