User manual.pdf

FCC ID: WIGDT-989

Users Manual

Download: PDF
FCCID_2858098

                         True RMS Digital
                              Multimeter
                              User Manual




Please read this manual before switching the unit on.
        Important safety information inside.


True RMS Digital Multimeter User Manual


                                                    True RMS Digital Multimeter User Manual


Contents                                                                                                    Page

1. Introduction............................................................................................ 4
2. Safety..................................................................................................... 4
3. Safety Instructions.................................................................................. 6
4. Feature................................................................................................... 7
5. Measure Function................................................................................... 10
6. Default Display........................................................................................ 18
7. Setup Options......................................................................................... 23
8. Specifications......................................................................................... 29




                                                                                                                   3


True RMS Digital Multimeter User Manual


1. Introduction
    Professional True RMS Industrial Digital Multimeter and TFT color LCD display,
providing fast A/D converting sampling time, high accuracy , built-in datalogging
and Trend Capture feactures. It can trace any interrupted problems of the equipments
and watch on without person. It is easy to find and solve the problems of the
production equipments, providing Bluetooth technology and memory the datasheets.
It is much more safe measurements.
    This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance,
Frequency(electrical & electronic), Duty Cycle, Diode Test, Insulation Test, and
Continuity plus Thermocouple Temperature. It can store and recall data. It features
a waterproof, rugged design for heavy duty use. Proper use and care of this meter
will provide many years of reliable service

2. Safety
               This symbol adjacent to another symbol, terminal or operating
               device indicates that the operator must refer to an explanation in
               the Operating Instructions to avoid personal injury or damage to
               the meter.

 WARNING       This WARNING symbol indicates a potentially hazardous situation,
               which if not avoided, could result in death or serious injury.

 CAUTION       This CAUTION symbol indicates a potentially hazardous situation,
               which if not avoided, may result damage to the product.

     MAX       This symbol advises the user that the terminal(s) so marked must
               not be connected to a circuit point at which the voltage with respect
               to earth ground exceeds (in this case) 1000 VAC or VDC.

               This symbol adjacent to one or more terminals identifies them as
               being associated with ranges that may, in normal use, be subjected
               to particularly hazardous voltages. For maximum safety, the meter
               and its test leads should not be handled when these terminals are
               energized.


4


                                     True RMS Digital Multimeter User Manual


                This symbol indicates that a device is protected throughout by double
                insulation or reinforced insulation.

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
   Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits
in which measures are taken to limit the transient overvoltages to an appropriate low
level.
   Note- Examples include protected electronic circuits.

OVERVOLTAGE CATEGORY II
  Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to
be supplied from the fixed installation.
  Note- Examples include household, office, and laboratory appliances.

OVERVOLTAGE CATEGORY III
   Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.
   Note- Examples include switches in the fixed installation and some equipment for
industrial use with permanent connection to the fixed installation.

OVERVOLTAGE CATEGORY IV
  Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.
  Note- Examples include electricity meters and primary over-current protection
equipment




                                                                                  5


True RMS Digital Multimeter User Manual


3. Safety Instructions
   This meter has been designed for safe use, but must be operated with caution.
The rules listed below must be carefully followed for safe operation.
1-NEVER apply voltage or current to the meter that exceeds the specified maximum:
    Input Protection Limits
    Function                             Maximum Input
    V DC or V AC                         1000VDC/AC rms
    mA AC/DC                             500mA 1000V fast acting fuse
    A AC/DC                              10A 1000V fast acting fuse
                                         (20A for 30 seconds max every
                                         15 minutes)
    Frequency, Resistance, Capacitance, 1000VDC/AC rms
    Duty Cycle, Diode Test, Continuity
    Temperature                          1000VDC/AC rms
    Surge Protection: 8kV peak per IEC 61010

2-USE EXTREME CAUTION when working with high voltages.
3-DO NOT measure voltage if the voltage on the "COM" input jack exceeds 1000V
3-above earth ground.
4-NEVER connect the meter leads across a voltage source while the function switch
3-is in the current, resistance, or diode mode. Doing so can damage the meter.
5-ALWAYS discharge filter capacitors in power supplies and disconnect the power
3-when making resistance or diode tests.
6-ALWAYS turn off the power and disconnect the test leads before opening the covers
3-to replace the fuse or batteries.
7-NEVER operate the meter unless the back cover and the battery and fuse covers
3-are in place and fastened securely.
   If the equipment is used in a manner not specified by the manufacturer, the
3-protection provided by the equipment may be impaired.




6


                                   True RMS Digital Multimeter User Manual


4. Feature
4-1. Understanding the Push Buttons                   GRAPH   MODE   SAVE    MAX
   The 6 push buttons on the front of the Meter
activate features that augment the function             F1      F2   F3      F4

selected using the rotary switch, navigate menus      RANGE
                                                                           HOLD
                                                                            REL
or control power to Meter circuits.
F1 Software key. Default switch to Graph measure.
F2 Software key. Default modes related to the rotary switch function
F3 Software key. Default into save mode default Display. And wake up for APO.
F4 Software key. Default modes MINMAX starts and stops MINMAX recording.
RANGE Into manual range and select range of the measure. If Pressing the Range
RANGE button for greater that 1 second will return Auto Range.
HOLD/REL Freezes the present reading in the display and allows the display to be
HOLD/REL saved. If Pressing the HOLD/REL button for greater that 1 second will
HOLD/REL switch relative mode.




                                                                                  7


True RMS Digital Multimeter User Manual


4-2. Understanding the Display

                                            6               10 8 7




        5             Auto range           06:32pm
                                                                          9


                                    -0.04
        4
        3

        2
                     -500    -300   -100    0        100    300    500

        1               GRAPH       MODE             SAVE         MAX


1-Soft key labels Indicates the function of the button just below the displayed label.
2-Bar graph Analog display of the input signal.
3-Minus sign Indicates a negative reading.
4-Displays measurement information about the input signal.
5-Indicates the range the Meter is in and the ranging mode (auto or manual)
6-Time Indicates the time set in the internal clock.
7-Battery level Indicates the charge level batteries.
8-Beeper Indicates the Meter’s beeper is enabled (not associated with the continuity
8-beeper).
9-Units Indicates the units of measure.
10-Bluetooth indicates




8


                                    True RMS Digital Multimeter User Manual


4-3. Understanding the Rotary Switch
   Select a primary measurement function by positioning the rotary switch to one
of the icons around its perimeter. For each function, the Meter presents a standard
display for that function (range, measurement units, and modifiers). Button choices
made in one function do not carry over into another function.
 V~       AC voltage measurements
 V–       DC and AC+DC voltage
          measurements.                                   4~2 0

 mV       DC(AC) milli-volts measurements.                     %



 Ω    CAP Resistance, Diode test,
          capacitance and CONTINUITY
 Hz%      measurements.                                                                   TEM P
                                                                                         °C °F


 Temp     Frequency measurements.
 A        Temperature measurements .
 mA       AC, dc amps measurements.
 4-20 mA% AC, dc milliamps measurements.
 uA       % 4-20MA measurements.
          AC, dc microampere
          measurements up to 5,000 uA.

4-4. Using the Input Terminals
  All functions except current use the VOHMS and COM input terminals. The two
current input terminals
            Input for 0 A to 10.00 A current
                                                                             Bluetooth

            (20VA overload for 30 seconds
                                                                             CAP

            on, 10 minutes off),                          20A fo r
                                                                             TEMP



                                                          30 sec



            Input for 0 A to 500 mA current               MAX
                                                          every
                                                          15 min


                                                                      10A


            measurements.                                            800mA




            Return terminal for all
            measurements.
            Input for voltage, continuity,
 CAP Temp
            resistance, diode test,
            conductance, capacitance.


                                                                                                  9


True RMS Digital Multimeter User Manual


5. Measure Function
5-1. AC Voltage Measurements
  WARNING: Risk of Electrocution. The probe tips may not be long enough to
  WARNING: contact the live parts inside some 240V outlets for appliances
  WARNING: because the contacts are recessed deep in the outlets. As a
  WARNING: result, the reading may show 0 volts when the outlet actually has
  WARNING: voltage on it. Make sure the probe tips are touching the metal
  WARNING: contacts inside the outlet before assuming that no voltage is
  WARNING: present.

   CAUTION: Do not measure AC voltages if a motor on the circuit is being
   CAUTION: switched ON or OFF. Large voltage surges may occur that can
   CAUTION: damage the meter.
1.Set the function switch to the VAC position.
2.Insert the black test lead banana plug into the
2.negative COM jack. Insert red test lead banana                  Auto range              00:00
                                                                                                    V~


2.plug into the positive V jack.                            120.00
                                                                  0         1         2       3      4          5V~




3.Read the voltage in the main display                            RANGE          SETUP
                                                                            True RMS Multimeter
                                                                                                  SAVE   HOLD




                                                           F1                    F2                 F3                 F4



                                                                                                                      HOLD
                                                          RANGE                                                        REL




                                                             4~20
                                                                  %




                                                                                                           TEMP
                                                                                                          °C °F



                                                                                                         Bluetooth



                                                                                                         CAP
                                                                                                         TEMP


                                                                      20A fo r
                                                                      30 sec
                                                                      MAX
                                                                      every
                                                                      15 min


                                                                                           10A
                                                                                          800mA




10


                                   True RMS Digital Multimeter User Manual


5-2. DC Voltage Measurements
   CAUTION: Do not measure DC voltages if a motor on the circuit is being
   CAUTION: switched ON or OFF. Large voltage surges may occur that can
   CAUTION: damage the meter.
1.Set the function switch to the VDC position.
2.Insert the black test lead banana plug into the                     Auto range              00:00
                                                                                                        V

2.negative COM jack. Insert the red test lead banana     100.00
2.plug into the positive V jack.                                      0



                                                                      RANGE
                                                                                 1        2



                                                                                      SETUP
                                                                                                  3




                                                                                 True RMS Multimeter
                                                                                                         4



                                                                                                      SAVE   HOLD
                                                                                                                 5V




3.Read the voltage in the display.                             F1                    F2                 F3                F4



                                                                                                                         HOLD
                                                              RANGE                                                       REL




                                                                 4~20
                                                                      %




                                                                                                               TEMP
                                                                                                              °C °F



                                                                                                             Bluetooth



                                                                                                             CAP
                                                                                                             TEMPCAP




                                                                          20A fo r
                                                                          30 sec
                                                                          MAX
                                                                          every
                                                                          15 min


                                                                                               10A
                                                                                              800mA




5-3. AC+DC
1.Set the function switch to the VDC position.   Auto range                          08:12pm
2.Insert the black test lead banana plug into
                                                                                                                                VAC+DC




                                                      0.0276
1.the negative COM jack. Insert the red test
 lead bananaplug into the positive jack
3.Press the MODE button to indicate “AC+DC”
                                                                          0.0000                                                V~
 on the display.
                                                                          0.0276                                                V
4.Read AC+DC measurement value in the
                                                 GRAPH        MODE                                             SAVE                  MAX
 display.


                                                                                                                                         11


True RMS Digital Multimeter User Manual


5-4. mV Voltage Measurements
   CAUTION: Do not measure mV voltages if a motor on the circuit is being
   CAUTION: switched ON or OFF. Large voltage surges may occur that can
   CAUTION: damage the meter.
1.Set the function switch to the mV
  position.                                                      Auto range              00:00


2.Press the softkey labeled Mode. switch
                                                          100.00
  mVDC (mVAC).                                                   0          1        2       3      4       5



                                                                 RANGE          SETUP            SAVE   HOLD

3.Insert the black test lead banana plug into the                           True RMS Multimeter


                                                          F1                    F2                 F3                F4


3.negative COM jack. Insert the red test lead banana     RANGE
                                                                                                                    HOLD
                                                                                                                     REL



3.plug into the positive V jack.                            4~20
                                                                 %


4.Read the mV voltage in the display
                                                                                                          TEMP
                                                                                                         °C °F



                                                                                                        Bluetooth



                                                                                                        CAP
                                                                                                        TEMPCAP




                                                                     20A fo r
                                                                     30 sec
                                                                     MAX
                                                                     every
                                                                     15 min


                                                                                          10A
                                                                                         800mA




12


                                    True RMS Digital Multimeter User Manual


5-5. Frequency Measurements                                             Auto range                     00:00



1.Set the function switch to the Hz% position.                                 0.0000
                                                                                                                      Hz




2.Insert the black test lead banana plug into the                       RANGE                  SETUP               SAVE      HOLD
                                                                                     True RMS Multimeter


2.negative COM jack. Insert the red test lead banana               F1                         F2                      F3                 F4




2.plug into the positive V jack.                               RANGE
                                                                                                                                       HOLD
                                                                                                                                        REL




3.Read the Frequency in the display                                 4~20
                                                                        %




                                                                                                                               TEMP
                                                                                                                              °C °F



                                                                                                                             Bluetooth



                                                                                                                             CAP
                                                                                                                             TEMP


                                                                               20A fo r
                                                                               30 sec
                                                                               MAX
                                                                               every
                                                                               15 min


                                                                                                        10A
                                                                                                       800mA




5-6. Resistance Measurements
   To avoid electric shock, disconnect power to
the unit under test and discharge all capacitors
                                                                 Auto range                   00:00
                                                                                                          Ω

                                                                    100.00
before taking any resistance measurements.                     0



                                                                 RANGE
                                                                          1



                                                                                     SETUP
                                                                                          2        3



                                                                                                       SAVE
                                                                                                               4



                                                                                                                    HOLD
                                                                                                                        5Ω




   Remove the batteries and unplug the line cords.
                                                                          True RMS Multimeter


                                                          F1                       F2                     F3                     F4




1.Set the function switch to the Ω CAP                   RANGE
                                                                                                                                HOLD
                                                                                                                                 REL




           position.
                                                            4~20
                                                               %




2.Insert the black test lead banana plug into the                                                                     TEMP
                                                                                                                     °C °F




2.negative COM jack. Insert the red test lead
                                                                                                                    Bluetooth



                                                                                                                    CAP
                                                                                                                    TEMP


                                                                    20A fo r




2.banana plug into the positive Ω Jack.
                                                                    30 sec
                                                                    MAX
                                                                    every
                                                                    15 min


                                                                                               10A
                                                                                              800mA




3.Read the resistance in the display.




                                                                                                                                              13


True RMS Digital Multimeter User Manual


5-7. Continuity Check
   WARNING: To avoid electric shock, disconnect power to the unit under test
   WARNING: and discharge all capacitors before taking any resistance
   WARNING: measurements. Remove the batteries and unplug the line cords.
1.Set the function switch to the Ω CAP
  Ω CAP position.                                             010.00
                                                                       Auto range                00:00
                                                                                                             Ω




2.Press the softkey labeled Mode. Switch to                         0



                                                                       RANGE
                                                                               1



                                                                                    SETUP
                                                                                         2




                                                                               True RMS Multimeter
                                                                                                     3



                                                                                                         SAVE
                                                                                                              4



                                                                                                                   HOLD
                                                                                                                           5Ω




2.Conductace                                                  F1




                                                            RANGE
                                                                                    F2                       F3



                                                                                                                                  HOLD
                                                                                                                                   REL
                                                                                                                                      F4




3.Insert the black test lead banana plug into the                 4~20
                                                                    %




3.negative COM jack. Insert the red test lead                                                                           TEMP
                                                                                                                       °C °F




3.banana plug into the positive jack.                                    20A fo r
                                                                                                                   Bluetooth



                                                                                                                   CAP
                                                                                                                       TEMP




4.If the resistance is less than approximately
                                                                         30 sec
                                                                         MAX
                                                                         every
                                                                         15 min


                                                                                                  10A
                                                                                                 800mA




3.25Ω, the audible signal will sound. If the circuit
3.is open, the display will indicate “OL”.




                                                                                                                                                 19



5-8. Diode Test
1.Set the function switch to the Ω CAP                              Auto range                     00:00
                                                                                                                       V

                                                                         0.5000
            position.                                              0            1            2           3         4             5    V



                                                                    RANGE            SETUP                   SAVE         HOLD


2.Press the softkey labeled Mode. Switch to                  F1
                                                                                True RMS Multimeter


                                                                                    F2                            F3                       F4




2.Diode.                                                    RANGE
                                                                                                                                          HOLD
                                                                                                                                           REL




3.Insert the black test lead banana plug into the              4~20
                                                                    %




3.negative COM jack and the red test lead banana                                                                               TEMP
                                                                                                                              °C °F




3.plug into the positive V jack.
                                                                                                                         Bluetooth



                                                                                                                          CAP
                                                                                                                           TEMP


                                                                         20A fo r
                                                                         30 sec




4.Forward voltage will typically indicate 0.400 to
                                                                         MAX
                                                                         every
                                                                         15 min


                                                                                                   10A
                                                                                                  800mA




3.3.200V. Reverse voltage will indicate “OL”.
3.Shorted devices will indicate near 0V and an
3.open device will indicate “OL” in both polarities.




14


                                     True RMS Digital Multimeter User Manual


5-9. Capacitance Measurements
   WARNING: To avoid electric shock, disconnect power to the unit under test
   WARNING: and discharge all capacitors before taking any capacitance
   WARNING: measurements. Remove the batteries and unplug the line cords.
1.Set the rotary function switch to the Ω CAP
  Ω CAP position.                                                                                     Auto range             00:00
                                                                                                                                      μF

                                                               020.00
2. Press the softkey labeled Mode. Switch to CAP                                                      RANGE               SETUP     SAVE   HOLD



3.Insert the black test lead banana plug into the
                                                                                                                True RMS Multimeter


                                                                                                F1                    F2              F3                F4




3.negative COM jack. Insert the red test lead banana                                        RANGE
                                                                                                                                                       HOLD
                                                                                                                                                        REL




3.plug into the positive V jack.
                                                                                                 4~20
                                                                                                      %




4.Read the capacitance value in the Display                                                                                                  TEMP
                                                                                                                                            °C °F



                                                                                                                                           Bluetooth



                                                                                                                                           CAP
                                                                                                                                           TEMP


                                                                                                          20A fo r
                                                                                                          30 sec
                                                                                                          MAX
                                                                                                          every
                                                                                                          15 min

                                                                                                                             10A
                                                                                                                            800mA




5-10. Temperature Measurements
1.Set the function switch to the TEMP(°C                       Auto range        00:00
                                                                                           °F

1.or °F) position.                                               0078.0
2.Press the softkey labeled Mode. Switch TEMP                  RANGE        SETUP        SAVE
                                                                       True RMS Multimeter
                                                                                                 HOLD




1.(°C or °F ).                                          F1                  F2             F3                        F4




3.Insert the Temperature Probe into the input jacks,
                                                                                                                 HOLD
                                                       RANGE                                                      REL




1.making sure to observe the correct polarity.
                                                         4~20
                                                             %




4.Read the temperature in the display                                                                 TEMP
                                                                                                     °C °F



                                                                                                 Bluetooth



                                                                                                 CAP
                                                                                                 TEMP


                                                                 20A fo r
                                                                 30 sec
                                                                 MAX
                                                                 every
                                                                 15 min

                                                                                  10A
                                                                                 800mA




                                                                                                                                                              15


True RMS Digital Multimeter User Manual


5-11. DC Current Measurements
   CAUTION: Do not make 20A current measurements for longer than 30
   CAUTION: seconds.
   Exceeding 30 seconds may cause damage to the meter and/or the test leads.
1.Insert the black test lead banana plug into the
1.negative COM jack.                                             Auto range            00:00


2.For current measurements up to 5000μA DC,                                                      A~

                                                         10.000
1set.the function switch to the μA position                    0         1         2       3      4       5 A~



                                                                 RANGE        SETUP            SAVE   HOLD

1.and insert the red test lead banana plug into the                      True RMS Multimeter




1.μA/mA jack.
                                                          F1                  F2                 F3                F4



                                                                                                                  HOLD
                                                         RANGE                                                     REL



3.For current measurements up to500mA DC,                   4~20
                                                               %


1.set the function switch to the mA position
1.and insert the red test lead banana plug into the                                                     TEMP
                                                                                                       °C °F




1.μA/mA jack.                                                                                         Bluetooth



                                                                                                      CAP
                                                                                                      TEMP




4.For current measurements up to 10A DC, set                       20A fo r
                                                                   30 sec
                                                                   MAX
                                                                   every
                                                                   15 min




1.the function switch to the 10A position
                                                                                        10A
                                                                                       800mA




1.and insert the red test lead banana plug into the
1.10A jack.
5.Press the MODE button to indicate “DC” on the
1.display.
6.Read the current in the display.




16


                                  True RMS Digital Multimeter User Manual


5-12. AC Current Measurements
   CAUTION: Do not make 10A current measurements for longer than 30
   CAUTION: seconds.
   Exceeding 30 seconds may cause damage to the meter and/or the test leads.
1.Insert the black test lead banana plug into the
1.negative COM jack.                                             Auto range              00:00
                                                                                                   A

2.For current measurements up to 5000μA AC,set            10.000
1.the function switch to the μA position and                     0



                                                                 RANGE
                                                                           1



                                                                                SETUP
                                                                                     2       3      4



                                                                                                 SAVE   HOLD
                                                                                                            5A




                                                                           True RMS Multimeter

1.insert the red test lead banana plug into the           F1                    F2                 F3                F4



1.μA/mA jack.                                            RANGE
                                                                                                                    HOLD
                                                                                                                     REL




3.For current measurements up to 500mA AC,set               4~20
                                                                 %




1.the function switch to the mA position
1.and insert the red test lead banana plug into the                                                       TEMP
                                                                                                         °C °F



                                                                                                        Bluetooth



1.μA/mA jack.                                                                                           CAP
                                                                                                        TEMP




4.For current measurements up to 10A AC,set the
                                                                     20A fo r
                                                                     30 sec
                                                                     MAX
                                                                     every
                                                                     15 min


                                                                                          10A
                                                                                         800mA




1.function switch to the 10A position and
1.insert the red test lead banana plug into the 10A
1.jack.
5.Press the MODE button to indicate “AC” on
5.the display.
6.Read the current in the display.




5-13. % 4 – 20mA MEASUREMENTS
1.Set up and connect as described for DC mA measurements.
2.Set the rotary function switch to the 4-20mA% position.
3.The meter will display loop current as a % with 0mA=-25%, 4mA=0%, 20mA=100%,
3.and 24mA=125%.



                                                                                                                           17


True RMS Digital Multimeter User Manual


6. Default Display
                      Auto range         06:32pm

                                                       V~
                             0 . 000 0
                         0         1     2         3          4              5V

                         GRAPH         MODE            SAVE               MAX



6-1. Graph Measure
   Press Software key lable Graph (F1), Meter                     Auto range               06:32pm

will switch to Graph measure.

   Press soft key START button. Press FAST or
SLOW soft keys to adjust sampling
                                                                  0
rate. Press CANCEL soft key to exit Graph and
return to normal measurement mode                                     Rate: 0.2 s
                                                                      Range: 0.01              0.0000 V~
                                                                      START         FAST        SLOW    CANNEL




  Press STOP soft key.                                            Auto range               06:32pm




                                                                  0




                                                                      Rate: 0.2 s
                                                                      Range: 500               -2.6000 mV DC
                                                                                                        STOP




18


                                     True RMS Digital Multimeter User Manual


  Press SAVE soft key to save Graph. Press         Auto range            06:32pm

BACK soft key to return.



                                                   0

                                                        Rate: 0.2 s
                                                        Range: 0.01               0.0000 V~
                                                        SAVE                                   BACK




6-2. Capturing Minimum and Maximum Values
                                                       Auto range        08:12pm
   To activate the MAXMIN mode, Press
Software key labled MAX(F4), at measure                               MAX MIN            V~
mode . As shown in Figure, the Meter displays
eat the top of the measurement page, and the
MAXMIN start date and time along the bottom
                                                            0.2660
                                                              MAX               0.3493    V~
                                                             Average            0.2636    V~
of the page. In addition, the recorded maximum,                MIN              0.2548    V~
average, and minimum values appear in the                              STOP                   PMAX
secondary display with their respective elapsed
 times.

   To stop a MINMAX recording session, press the Softkey labeled Stop. The summary
information in the display freezes, and the softkeys change function to allow saving
the collected data. Pressing the softkey labeled Close exits the MIN MAX record
session without saving the collected data.

   To save the MIN MAX screen data, the MIN MAX session must be ended by
pressing the softkey labeled Stop. Next, press the softkey labeled Save.




                                                                                                 19


True RMS Digital Multimeter User Manual


6-3. Capturing Peak Values                        Auto range             08:12pm

  To activate the peak mode, at AC measure                         PEAK                  V~
                                                         0.2676
MINMAX mode , Press Software key labled
PMAX(F4).
                                                          PMAX               0.6354               V~
                                                         Average              0.263               V~
                                                          PMIN               -0.5894              V~
                                                                    STOP                           MAX



6-4. Relative Values
                                                  Auto range             08:20pm
  To activate the relative mode, Press the
HOLD/REL button for greater that 1 second.                         REL                   V~
                                                  - 0 .0430
                                                         Reference           0.3079               V~
                                                                             0.2649               V~

                                                  GRAPH             MODE               SAVE            MAX




6-5. Hold Mode
  To freeze the display for any function, press   Auto range             06:32pm


key HOLD.                                                          HOLD
                                                                                       V~
   Press key save to memory. And press close
return measure.
                                                         0.2823
                                                     0         1         2         3          4          5V


                                                                                   SAVE            CLOSE




20


                                   True RMS Digital Multimeter User Manual


6-6. Save Function
  Then pressing the labeled SAVE(F3), into save
menu.




6-7. Storing Individual Measurement Data
   For common measurement functions, a snapshot of the screen data is saved by
pressing the softkey labeled Save. Then pressing the labeled DOWN(F3) to the Save
select Item, pressing the softkey labeled ENTER(F1)

6-8. Viewing Memory Data
                                                  06/02/14              06:32pm
   Viewing data stored in the Meter’s memory
is performed through the save menu. Press the
                                                           View Men                   V~
softkey labeled DOWN (F3). Position the menu
selector next to the menu item labeled ViewM.
And pressing the softkey labeled ENTER(F1)
                                                           0.3078
                                                       0        1        2        3          4     5V


                                                      DELETE          PREV            NEXT       BACK


6-9. Viewing Graph Data
   Viewing data stored in the Meter’s memory      06/02/14          06:32pm   ViewGrap

is performed through the save menu. Press the
softkey labeled DOWN (F3). Position the menu
selector next to the menu item labeled Graph.

                                                  0
 Pressing the softkey labeled ENTER(F1)
                                                      Rate: 0.2 s
                                                      Range: 50M                  31.788 MΩ
                                                      ENTER          PREV         NEXT           CLOSE




                                                                                                    21


True RMS Digital Multimeter User Manual


  Press the << and >> soft keys to move             06/02/14           06:32pm    ViewGrap

cursor



                                                    0

                                                        Rate: 0.2 s
                                                        Range: 50M                    30.823 MΩ
                                                        DELETE            «              »    BACK




6-10. Recording Measurement Data
   Press the softkey labeled Save. Then             Auto range              06:32pm

pressing the labeled DOWN (F3) to the Record
select Item, pressing the softkey labeled
ENTER(F1). Press the softkey labeled Start to
start records. The recording session will
                                                           366.55 Set Duration: 00Days 00Hrs 01Min
                                                                  Set Sample Interval: 00Min 01Sec
continue until the allocated memory is used,                      Start Record
the batteries expire, the rotary switch is moved.       ENTER             UP          DOWN   CLOSER
or the session is terminated by pressing the
softkey labeled Stop

6-11. Viewing Trend Data                            Auto range              08:27pm

   Viewing data stored in the Meter’s memory                          Recording



                                                           351.44
is performed through the save menu. Press
the softkey labeled DOWN (F3). Position the
menu selector next to the menu item labeled                  Star t Times: 06/02/14 08:26:09pm
ViewR and pressing the softkey labeled                       Duration: 00days 00hrs 00min 37sec
                                                             Samples: 37 Rlog0002
ENTER(F1)
                                                        TREND            PREV         NEXT    CLOSER

  Press the softkey labeled TREND (F1)




22


                                   True RMS Digital Multimeter User Manual


   Press the + soft key to increase Graph          Auto range            08:27pm

resolution. Press the >> soft keys to move        400
                                                                     06/02/14           08:26:09pm


cursor.                                           320

                                                  240

                                                  160

                                                  80

                                                  0.0
                                                    00:00        00:10      00:20      00:30     00:40
                                                                              331.99 Mv 08:26:25pm
                                                    DELETE          +              »         BACK




6-12. Info
   Viewing data stored in the Meter’s memory       Auto range         08:20pm
                                                    Fno. Graph- According to graphically display
is performed through the save menu. Press the       Fno. measurement information
softkey labeled DOWN (F3). Position the menu        Fno. Mode-Releted to the rotary switch
selector next to the menu item labeled INFO         Fno. function.

and pressing the softkey labeled ENTER(F1)          Fno. Save- Accesses the memory management
                                                    Fno. menu for saving measurement, setting
                                                    Fno. up recording sessions, or viewing and
                                                    Fno. deleting stored measurements from memory.

                                                                    UP          DOWN         CLOSE




7. Setup Options
   Viewing data stored in the Meter’s memory
is performed through the save menu. Press the
softkey labeled DOWN (F3). Position the menu
selector next to the menu item labeled SETUP
and pressing the softkey labeled ENTER(F1)




7-1. Resetting Meter
   The Meter’s setup options can be reset to default values through the setup menu.
Open the setup menu. Position the menu selector next to the menu item labeled
RESET and press the key Enter. Then Position the menu selector next to the menu
item labeled SETUP and press the key OK. Then A message will appear asking to
confirm the reset action. Press the softkey labeled OK to perform the reset.
                                                                                                   23


True RMS Digital Multimeter User Manual


7-2. Meter Info
  The Meter Info selection lists the serial number, firmware version, are displayed.
Open the setup menu. Position the menu selector next to the menu item labeled
METER INFO and press the key Enter.

7-3. Setting Format                                    Auto range       08:32pm
   Open the setup menu. Position the menu                                Format

selector next to the menu item labeled FORMAT                Beeper
                                                             Numeric Format
and press the key Enter. Using the cursor buttons,           Date Format
move the menu selector next to the menu item                 Time Format
labeled Numeric(Date\Time) format, press the key
EDIT to edit, select 0.0000(0,0000) and
MM/DD/YY(DD/MM/YY) and 24 HOUR(12 HOUR)                  EDIT        UP            DOWN    CLOSER

format.

7-4. Setting Display
  Open the setup menu. Position the menu selector      Auto range       08:32pm
next to the menu item labeled DISPLAY and press                          Display

the key Enter.                                               Set Date: 06/02/14 dd/mm/yy
                                                             Set Time: 08:29:00 pm
                                                             Auto Power Off: 00
                                                             Foreground:         Background:
                                                             Select Font: 0


                                                         EDIT        UP            DOWN    CLOSER



7-5. Setting Date and Time
  Open the setup menu. Position the menu selector next to the menu item labeled
Display and press the key Enter.
   Next, position the menu selector next to either the Set Date item or Set Time item and
press the softkey labeled Edit.




24


                                    True RMS Digital Multimeter User Manual


7-6. Auto Power Off
   Open the setup menu. Position the menu selector next to the menu item labeled
Display and press the key Enter. Then Position the menu selector next to the menu
item labeled POWER OFF and press the key EDIT.
   To set Auto Power Off. Use UP and DOWN to adjust the time to one of the preset
values. 0 is disable the timeout feature. Press the softkey labeled OK to set the
selected time. Press the softkey labeled Close to return.

7-7. Foreground and Background
   Open the setup menu. Position the menu selector next to the menu item labeled
Display and press the key Enter. Then Position the menu selector next to the menu
item labeled Foreground and Background and press the key OK. Use UP and DOWN
to adjust.

7-8. Set Font
   Open the setup menu. Position the menu selector next to the menu item labeled
Display and press the key Enter. Then Position the menu selector next to the menu
item labeled select font and press the key EDIT. Use UP and DOWN to adjust.

7-9. Bluetooth
   You can use the Bluetooth communication
                                                   Auto range    08:32pm
link and transfer the contents of a meter’s
memory to a PC.
   Open the setup menu. Position the menu
selector next to the menu item labeled Bluetooth
and press the key Enter. “Turn on Bluetooth”
                                                            Turn on Bluetooth?
and press OK ,”Turn off Bluetooth” and press
OK.                                                  OK                          CANCEL




                                                                                   25


True RMS Digital Multimeter User Manual


7-10. Replacing the Batteries
   Refer to Figure and replace the batteries as follows:
1.Turn the Meter off and remove the test leads from the terminals.
2.Remove the battery door assembly by using a standardblade screwdriver to turn
2.the battery door screw one-half turn counterclockwise.
3. Replace the batteries with 7.4 volt charge batteries Observe proper polarity.
4. Reinstall the battery door assembly and secure it by turning the screw one-half
2.turn clockwise.

7-11. Replacing the Fuses
   Referring to Figure , examine or replace the Meter's fuses as follows:
1.Turn the Meter off and remove the test leads from the
terminals.
2.Remove the battery door assembly by using a standardblade screwdriver to turn
2.the battery door screw one-half turn counterclockwise.
3.Remove the fuse by gently prying one end loose, then
sliding the fuse out of its bracket.
4.Install only specified replacement fuses.
5.Reinstall the battery door assembly and secure it by turning the screw one-half
2.turn clockwise




26


                                     True RMS Digital Multimeter User Manual


7-12 Li-ion Battery Charge
1.Set the function switch to the OFF/CHG position.
2.Insert the socket into the Meter Input port. And the Adapter connected to the switch
2.socket.
2.Then Insert the Adapter into Power socket.
3.Display charge symbol in TFT color LCD display


                   Adapter
                                                                                                        Tru e
                                                                                                                RM S
                                                                                                                       Mu ltim
                                                                                  F1                                             ete r
                                                                                                   F2
                                                                                                                   F3
                                                                      RAN
                                                                            GE
                                                                                                                                         F4



                                                                                                                                 HOL D
                                                                                                                                 REL




                                                                                   Blu etoo
                                                                                              th
                                                       20A fo
                                                      30 sec
                                                              r                  CAP
                                                     MAX
                                                                                 TEM P
                                                   every
                                                  15 min




                                                                  5




Enclosure                    Double molded, waterproof
Shock (Drop Test)            6.5 feet (2 meters)
Diode Test                   Test current of 0.9mA maximum, open circuit
                             voltage 3.2V DC typical
Continuity Check             Audible signal will sound if the resistance is less
                             than 25Ω (approx.), test current <0.35mA
PEAK                         Captures peaks >1ms
Temperature Sensor           Requires type K thermocouple
Input Impedance              >10MΩ VDC & >9MΩ VAC
AC Response                  True rms


                                                                                                                                              27


True RMS Digital Multimeter User Manual


AC True RMS              The term stands for “Root-Mean-Square,” which
                         represents the method of calculation of the voltage
                         or current value. Average responding multimeters
                         are calibrated to read correctly only on sine waves
                         and they will read inaccurately on non-sine wave or
                         distorted signals. True rms meters read accurately
                         on either type of signal.
ACV Bandwidth            50Hz to 20000Hz
Display                  50,000 count TFTLCD
Overrange indication     “OL” is displayed
Auto Power Off           5-30minutes (approximately) with disable feature
Polarity                 Automatic (no indication for positive); Minus (-)
                         sign for negative
Measurement Rate         20 times per second, nominal
Low Battery Indication   “ ” is displayed if battery voltage drops below
                         operating voltage
Battery                  One 7.2 volt (NEDA 1604) battery
Fuses                    mA, μA ranges; 0.8A/1000V ceramic fast blow A
                         range; 10A/1000V ceramic fast blow
Operating Temperature    5ºC to 40ºC (41ºF to 104ºF)
Storage Temperature      -20ºC to 60ºC (-4 F to 140 F)
Operating Humidity       Max 80% up to 87ºF (31ºC) decreasing linearly to
Storage Humidity         50% at 40ºC (104ºF)
Operating Altitude       <80% 7000ft. (2000meters) maximum.
Safety                   This meter is intended for origin of installation use
                         and protected, against the
                         users, by double insulation per EN61010-1
                         and IEC61010-1 2nd Edition (2001) to
                         Category IV 600V and Category III 1000V; Pollution
                         Degree 2. The meter also meets UL 61010-1, 2nd
                         Edition (2004), CAN/CSA C22.2 No. 61010-1 2nd
                         Edition (2004),and UL 61010B-2-031, 1st Edition (2003)




28


                                   True RMS Digital Multimeter User Manual


8. Specifications
 AC      Range Resolution 50/60HZ <1KHZ             <5kHZ        <20KHZ[1]
 Voltage 500mV 0.01mV     ±0.5% ±1.0%               ±3.0%        ±5.5%
         5V    0.0001V +5         +5                +5           +20
         50V   0.001V
         500V  0.01V              ±1.5%             ±3.5%       unspecified
                                  +10               +10
         1000V 0.1V                                 unspecified unspecified
[1] upper 10 % of range,

Function         Range           Resolution     Accuracy
DC Voltage       500mV[1]        0.01mV         (0.1% + 5digits)
                 5V              0.0001V        (0.05% + 5digits)
                 50V             0.001V         (0.05% + 5digits)
                 500V            0.01V          (0.05% + 5digits)
                 1000V           0.1V           (0.1% + 5)
[1] When using the relative mode (REL Q) to compensate for offsets.

(AC+DC)                           <1KHZ       <5KHZ
              5V      0.0001V     (1.2% + 20) (3.0% + 20)
              50V     0.001V
              500V    0.01V
              1000V   0.1V

 Function         Range           Resolution     Accuracy
 Resistance       500Ω[1]         0.01Ω          0.20%+10
                  5kΩ             0.0001kΩ       0.20%+5
                  50kΩ            0.001kΩ        0.20%+5
                  500kΩ           0.01kΩ         0.50%+5
                  5MΩ             0.0001MΩ       0.50%+5
                  50MΩ            0.001MΩ        2.0%+10
 [1] When using the relative mode (REL Q) to compensate for offsets.
                                                                         29


True RMS Digital Multimeter User Manual


Function        Range             Resolution Accuracy
Temp            -200 to 1350˚C 0.1˚C             ±(1.0% reading + 3.0°C)
(type-K)                                         ±(1.0% reading +5.4°F)
                                                 (probe accuracy not included)
                1. Does not include error of the thermocouple probe.
                2. Accuracy specification assumes ambient temperature
                stable to ±1˚C.
                3. Use a long time, reading will increase 2 ˚C.
DC Current      500μA             0.01μA         ±0.2%+5
                5000μA            0.1μA          ±0.2%+5
                50mA              0.001mA        ±0.2%+5
                500mA             0.01mA         ±0.3%+8
                10A               0.001A         ±0.5%+8
AC Current                                       <1KHZ             <5KHZ
                500μA             0.01μA         ±(0.8% + 5) ±(3% + 5)
                5000μA            0.1μA
                50mA              0.001mA
                500mA             0.01mA
                10A               0.001A
                (20A: 30 sec max with reduced accuracy)
                All AC current ranges are specified from 5% of range to
                100% of range
Capacitance     5nF[1]            0.001nF        ±(1.5% + 20)
                50nF              0.01nF         ±(1.5% + 8)
                500nF             0.1nF          ±(1.0% + 8)
                5μF               0.001μF        ±(1.5% + 8)
                50μF              0.01μF         ±(1.0% + 8)
                500μF             0.1μF          ±(1.5% + 8)
                10mF              0.01mF         ±(2.5% + 20)
                [1] With a film capacitor or better, using relative mode
                (REL Δ) to zero residual.


30


                                       True RMS Digital Multimeter User Manual


 Function           Range               Resolution        Accuracy
 Frequency          50Hz                0.001Hz           ±(0.01% + 5)
 (electronic)       500Hz               0.01Hz            ±(0.01% + 5)
                    5kHz                0.0001kHz         ±(0.01% + 5)
                    50kHz               0.001kHz          ±(0.01% + 5)
                    500kHz              0.01kHz           ±(0.01% + 5)
                    5MHz                0.0001MHz         ±(0.01% + 5)
                    10MHz               0.001MHz          unspecified
                    Sensitivity: 2V rms min. @ 20% to 80% duty cycle and
                    <100kHz; 5Vrms min @ 20% to 80% duty cycle and
                    > 100kHz.
 Frequency          10.00Hz-10KHz 0.01Hz - 0.001KHz ±(0.5% reading)
 (electrical)       Sensitivity:2Vrms
 Duty Cycle         0.1 to 99.90%       0.01%              ±(1.2% reading
                                                          + 2 digits)
                    Pulse width: 100μs - 100ms, Frequency: 5Hz to 150kHz

FCC and IC warning:
   This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions : (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
   Warning: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
                                                                                    31


                  True RMS Digital Multimeter User Manual


                   Reorient or relocate the receiving antenna.
                   Increase the separation between the equipment and receiver.
                   Connect the equipment into an outlet on a circuit different from that to which the
                   receiver is connected.
                   Consult the dealer or an experienced radio/TV technician for help

                      This device complies with Industry Canada licence-exempt RSS standard(s).
                   Operation is subject to the following two conditions: (1) this device may not cause
                   interference, and (2) this device must accept any interference, including interference
                   that may cause undesired operation of the device.
                      Under Industry Canada regulations, this radio transmitter may only operate using
                   an antenna of a type and maximum (or lesser) gain approved for the transmitter by
                   Industry Canada. To reduce potential radio interference to other users, the antenna
                   type and its gain should be so chosen that the equivalent isotropically radiated power
                   (e.i.r.p.) is not more than that necessary for successful communication.
                      Conformémentà la réglementationd'Industrie Canada, le présent émetteur
                   radiopeutfonctionner avec uneantenne d'un type et d'un gain maximal (ouinf érieur)
                   approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques
                   de brouillage radioélectriqueàl'intention des autresutilisateurs, il fautchoisir le type
                   d'antenne et son gain de sorteque la puissance isotroperayonn ée équivalente
                   (p.i.r.e.) ne dépasse pas l'intensité nécessaireà l'établissement d'une communication
                   satisfaisante.
                      Le présent appareilestconforme aux CNR d'Industrie Canada applicables aux
                   appareils radio exempts de licence. L'exploitationestautorisé e aux deux
                   conditionssuivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur
                   de l'appareildoit accepter tout brouillage radioélectriquesubi,même si le brouillageest
                   susceptible d'encompromettre le fonctionnement

This device complies with FCC and Industry Canada RF radiation exposure limits set forth for general population (uncontrolled exposure).
This device must not be collocated or operating in conjunction with any other antenna or transmitter.
                   Rev.151027



Document Created: 2015-10-31 11:16:43
Document Modified: 2015-10-31 11:16:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC