Radar Test Report

FCC ID: WHBMBDASHCAMF

Test Report

Download: PDF
FCCID_4268157

L41CT
  HCTCO.,LTD.
               74, Seoicheon—ro 578beon—gil, Majang—myeon, Icheon—si, Gyeonggi—do, 17383.Rep. of KOREA
                                  TEL: +82—31—645—6300                       FAX: +82—31—645—6401




                                 FCC 24 GHz Radar Report
                                                              Certification

     o                                                                      Date of Issue:
Applicant Name:                                                             May 08, 2019
Mobile Appliance, Inc.
                                                                            Test Site/Location:
Address:                                                                    HCT CO., LTD., 74,Seoicheon—ro 578beon—gil, Majang—
Gwanyang—dong—1701~1706, Daerung Techno #15, 401,                           myeo,Icheon—si, Gyeonggi—do, 17383, Rep. of KOREA
Simin—daero, Dongan—gu, Anyang—si, Gyeonggi—do, Korea                       Report No.: HCT—RF—1905—FCO06—R1



FCC ID:                          WHBMBDASHCAMF

APPLICANT:                       Mobile Appliance, Inc.

Model:                           Mercedes—Benz Dashcam Front
EUT Type:                        Mercedes—Benz Dashcam Front
Max. RF Output Power:            106.88 dBuV/m @3 m

Operating Frequency              24194.822 MHz ~ 24215.578 MHz

Modulation type                  CW
FCC Classification:              Low Power communication Device Transmitter(DXX)
FCC Rule Part(s):                Part 15.249


    Engineering Statement:

    The measurements shown in this report were made in accordance with the procedures indicated, and the emissions from this

    equipment were found to be within the limits applicable. | assume full responsibility for the accuracy and completeness of these

    measurements, and for the qualifications of all persons taking them.

    HCT CO., LTD. Certifies that no party to this application has subject to a denial of Federal benefits that includes FCC benefits pursuant

    to section 5301 of the Anti—Drug Abuse Act of 1998,21 U.S. C.853(a)




    Report prepared by : Kwang II Yoon                                     Approved by : Kwon Jeong
    Engineer of Telecommunication testing center                           Manager of Telecommunication testing center
     This report only responds to the tested sample and may not be reproduced, exceptin full, without written approval of the HCT Co., Ltd.



         F—TP22—03 (Rev.00)            '                       1 /28                                             HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                           FCC ID: WHBMBDASHCAMF



                                          Version
     TEST REPORT NO.               DATE                             DESCRIPTION

   HCT-RF-1905-FC006      May 07, 2019         - First Approval Report

   HCT-RF-1905-FC006-R1   May 08, 2019         - The frequency range has changed.




    F-TP22-03 (Rev.00)                     2 / 28                             HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                                                             FCC ID: WHBMBDASHCAMF



                                                 Table of Contents
   1.     EUT DESCRIPTION .................................................................................................................................. 4
   2. TEST METHODOLOGY ................................................................................................................................ 5
         2.1 EUT CONFIGURATION ....................................................................................................................... 5
         2.2 EUT EXERCISE ................................................................................................................................... 5
         2.3 GENERAL TEST PROCEDURES ....................................................................................................... 5
         2.4 DESCRIPTION OF TEST MODES ...................................................................................................... 5
   3. INSTRUMENT CALIBRATION...................................................................................................................... 6
   4. FACILITIES AND ACCREDITATIONS .......................................................................................................... 6
         4.1 FACILITIES .......................................................................................................................................... 6
         4.2 EQUIPMENT ........................................................................................................................................ 6
   5. ANTENNA REQUIREMENTS ....................................................................................................................... 6
   6. MEASUREMENT UNCERTAINTY ................................................................................................................ 7
   7. SUMMARY TEST OF RESULTS .................................................................................................................. 8
   8. TEST RESULT .............................................................................................................................................. 9
         8.1 OCCUPIED BANDWIDTH MEASUREMENT ...................................................................................... 9
         8.2 RADIATED MEASUREMENT............................................................................................................ 12
   9. LIST OF TEST EQUIPMENT ...................................................................................................................... 27
   10. ANNEX A_TEST SETUP PHOTO ............................................................................................................. 28




    F-TP22-03 (Rev.00)                                                   3 / 28                                                    HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                FCC ID: WHBMBDASHCAMF


   1. EUT DESCRIPTION
   Model                       Mercedes-Benz Dashcam Front
   EUT Type                    Mercedes-Benz Dashcam Front
   Power Supply                DC 12.0 V
   Frequency Range             24150 MHz -24250 MHz
   Operating Frequency         24194.822 MHz ~ 24215.578 MHz
   Fundamental                 Peak        106.88 dBuV/m @3 m
   Field Strength Level        Average     105.58 dBuV/m @3 m
   Modulation Type             CW
                               Antenna type: PCB antenna
   Antenna Specification       Peak Gain : 7 dBi
                               Maximum Dimension : 24.1 mm
   Date(s) of Tests            April 08, 2019 ~ May 07 2019




    F-TP22-03 (Rev.00)                        4 / 28              HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                  FCC ID: WHBMBDASHCAMF




   2. TEST METHODOLOGY
   The measurement procedure described in the American National Standard of Procedures for
   Compliance Testing of Unlicensed Wireless Devices (ANSI C63.10-2013) Operating Under
   §15.245” were used in the measurement.


   2.1 EUT CONFIGURATION
   The EUT configuration for testing is installed on RF field strength measurement to meet the
   Commissions requirement and operating in a manner that intends to maximize its emission
   characteristics in a continuous normal application.


   2.2 EUT EXERCISE
   The EUT was operated in the engineering mode to fix the Tx frequency that was for the purpose of
   the measurements. According to its specifications, the EUT must comply with the requirements of
   the Section 15.249 under the FCC Rules Part 15 Subpart C.


   2.3 GENERAL TEST PROCEDURES
   Conducted Emissions
   The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
   requirements in Section 6.2 of ANSI C63.10. (Version :2013) Conducted emissions from the EUT
   measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-peak and
   average detector modes.
   Radiated Emissions
   The EUT is placed on a turn table, which is 0.8 m above ground plane below 1GHz. Above 1GHz
   with 1.5m using absorbers between the EUT and receive antenna. The turntable shall rotate 360
   degrees to determine the position of maximum emission level. EUT is set far-field distance away
   from the receiving antenna, which varied from 1 m to 4 m to find out the highest emission. And also,
   each emission was to be maximized by changing the polarization of receiving antenna both
   horizontal and vertical. In order to find out the max. emission, the relative positions of this hand-
   held transmitter (EUT) was rotated through three orthogonal axes according to the requirements in
   Section 8 of ANSI C63.10. (Version: 2013)


   2.4 DESCRIPTION OF TEST MODES
   The EUT has been tested under operating condition. Test program used to control the EUT for
   staying in continuous transmitting and receiving mode is programmed.




    F-TP22-03 (Rev.00)                           5 / 28                               HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                               FCC ID: WHBMBDASHCAMF


   3. INSTRUMENT CALIBRATION
   The measuring equipment, which was utilized in performing the tests documented herein, has
   been calibrated in accordance with the manufacturer's recommendations for utilizing calibration
   equipment’s, which is traceable to recognized national standards.
   Especially, all antenna for measurement is calibrated in accordance with the requirements of C63.5
   (Version : 2006).


   4. FACILITIES AND ACCREDITATIONS

   4.1 FACILITIES
   The SAC(Semi-Anechoic Chamber) and conducted measurement facility used to collect the
   radiated data are located at the 74, Seoicheon-ro 578beon-gil, Majang-myeon, Icheon-si,
   Gyeonggi-do, Korea. The site is constructed in conformance with the requirements of ANSI C63.4.
   (Version :2014) and CISPR Publication 22. Detailed description of test facility was submitted to the
   Commission and accepted dated April 02, 2018 (Registration Number: KR0032)


   4.2 EQUIPMENT
   Radiated emissions are measured with one or more of the following types of Linearly polarized
   antennas: tuned dipole, bi-conical, log periodic, bi-log, and/or ridged waveguide, horn. Spectrum
   analyzers with pre-selectors and quasi-peak detectors are used to perform radiated measurements.
   Conducted emissions are measured with Line Impedance Stabilization Networks and EMI Test
   Receivers. Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also
   used for making measurements.
   All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring
   Apparatus and Measurement Methods.”


   5. ANTENNA REQUIREMENTS

   According to FCC 47 CFR §15.203:
    “An intentional radiator antenna shall be designed to ensure that no antenna other than that
   furnished by the responsible party can be used with the device. The use of a permanently attached
   antenna or of an antenna that uses a unique coupling to the intentional radiator shall be
   considered sufficient to comply with the provisions of this section.”


   * The antennas of this E.U.T are permanently attached.


   *The E.U.T Complies with the requirement of §15.203


    F-TP22-03 (Rev.00)                          6 / 28                             HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                   FCC ID: WHBMBDASHCAMF


   6. MEASUREMENT UNCERTAINTY
   The measurement uncertainties shown below were calculated in accordance with the requirements
   of ANSI C63.4:2014.
   All measurement uncertainty values are shown with a coverage factor of k = 2 to indicate a 95 %
   level of confidence.
                                     Parameter                   Expanded Uncertainty (±dB)

                    Conducted Disturbance (150 kHz ~ 30 MHz)                1.82

                         Radiated Disturbance (9 kHz ~ 30 MHz)              3.40

                         Radiated Disturbance (30 MHz ~ 1 GHz)              4.80

                         Radiated Disturbance (1 GHz ~ 18 GHz)              5.70

                     Radiated Disturbance (18 GHz ~ 40 GHz)                 5.44

                     Radiated Disturbance (40 GHz ~ 60 GHz)                 5.29

                     Radiated Disturbance (60 GHz ~ 90 GHz)                 5.31

                     Radiated Disturbance (90 GHz ~ 100 GHz)                5.29




    F-TP22-03 (Rev.00)                                  7 / 28                         HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                                 FCC ID: WHBMBDASHCAMF


   7. SUMMARY TEST OF RESULTS

                                               FCC Part                                                         Test
              Test Description                                           Test Limit           Test Condition
                                              Section(s)                                                       Result


             Occupied Bandwidth                 §2.1049                      N/A                               PASS




       Fundamental Field Strength Level        §15.249(a)                < 250 mV/m                            PASS


                                                                                                RADIATED

         Harmonic Field Strength Level         §15.249(a)               < 2500 mV/m                            PASS


         General Field Strength Limits                              < 15.209 limits or 50dB
                                            §15.205, 15.209,
            (Restricted Bands and                                   below the level of the                     PASS
                                               15.249(d)
           Radiated Emission Limits)                                     fundamental



                             Measurement Result of 24 GHz Radar Transmit On/Off Timing




   - The EUT duty cycle is calculated according to ANSI C63.26 - 5.2.4.3.4.

                        Duty Cycle = On-time / Transmitter period = 1.29 us / 24.57 us = 0.0525

                        Duty Correction = 10 log (1/duty cycle) = 10 log (1/0.0525) = 12.8 dB



    F-TP22-03 (Rev.00)                                     8 / 28                                    HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                           FCC ID: WHBMBDASHCAMF


   8. TEST RESULT
   8.1 OCCUPIED BANDWIDTH MEASUREMENT
   Test Requirements and limit, §2.1049
   The occupied bandwidth, that is the frequency bandwidth such that, below its lower and above its
   upper frequency limits, the mean powers radiated are each equal to 0.5 percent of the total mean
   power radiated by a given emission shall be measured.


   ▣ TEST CONFIGURATION




   ▣ TEST PROCEDURE
   The transmitter output is connected to the Spectrum Analyzer.
     RBW = 1% to 3% of the 99% bandwidth.
     VBW ≥ 3 x RBW
     Detector = Peak
     Trace mode = max hold
     Sweep = auto couple
     Allow the trace to stabilize


   Note : 1. We tested Occupied Bandwidth using the automatic bandwidth measurement capability of
            a spectrum analyzer.
          2. Measured distance : 1 m




    F-TP22-03 (Rev.00)                        9 / 28                           HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                     FCC ID: WHBMBDASHCAMF



   ▣ RESULT PLOTS
                            Occupied Bandwidth plot (Low Channel)




                             Occupied Bandwidth plot (Mid Channel)




    F-TP22-03 (Rev.00)                    10 / 28                      HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                     FCC ID: WHBMBDASHCAMF

                            Occupied Bandwidth plot (High Channel)




    F-TP22-03 (Rev.00)                   11 / 28                       HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                  FCC ID: WHBMBDASHCAMF



   8.2 RADIATED MEASUREMENT.

   Test Requirements and limit, §15.249 (d)
   Operation within the bands 902–928 MHz, 2400–2483.5 MHz, 5725–5875 MHZ, and 24.0–24.25
   GHz.
   (a) Except as provided in paragraph (b) of this section, the field strength of emissions from intentional
   radiators operated within these frequency bands shall comply with the following:


                                       Field strength of fundamental       Field strength of harmonics
     Fundamental frequency
                                              (millivolts/meter)                (microvolts/meter)
            902-928 MHz                               50                                500
          2400-2483.5 MHz                             50                                500
           5725-5875 MHz                              50                                500
           24.0-24.25 GHz                             250                               2500



   (c) Field strength limits are specified at a distance of 3 meters.


   (d) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be
   attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission
   limits in §15.209, whichever is the lesser attenuation.


   (e) As shown in §15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)
   and (b) of this section are based on average limits. However, the peak field strength of any emission
   shall not exceed the maximum permitted average limits specified above by more than 20 dB under any
   condition of modulation. For point-to-point operation under paragraph (b) of this section, the peak field
   strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth




    F-TP22-03 (Rev.00)                             12 / 28                            HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                               FCC ID: WHBMBDASHCAMF


   Test Procedure
   1. The EUT is placed on a turntable, which is 1.5 m above ground plane.
   2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
     level.
   3. In case from 9 kHz to 18 GHz, EUT is set 3 m away from the receiving antenna, which is varied
      from 1m to 4m to find out the highest emissions.
     In case from 18 GHz to 60 GHz, EUT is set 1 m away from the receiving antenna, which is
     varied from 1m to 4m to find out the highest emissions.
     In case above 60 GHz, EUT is set 1.5 m away from the receiving antenna, which is varied from
      1m to 4m to find out the highest emissions.
   4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
   5. And also, each emission was to be maximized by changing the polarization of receiving
     antenna both horizontal and vertical.
   6. Repeat above procedures until the measurements for all frequencies are complete.
   7. Measured Distance
              Frequency      Frequency                             Far Field        Measured
                                             Antenna Size(m)
          Range(GHz)           (MHz)                             Distance(m)       Distance(m)
        24.000 ~ 24.250        24125                              0.0732736              1
               18 ~ 40         40000                             0.122122667             1
               40 ~ 60         60000                0.0214         0.183184              1
               60 ~ 90         90000                               0.274776              1
              90 ~ 100         100000                            0.305306667             1




    F-TP22-03 (Rev.00)                        13 / 28                            HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1             FCC ID: WHBMBDASHCAMF


   Test Configuration


   Below 30 MHz




   30 MHz - 1 GHz




    F-TP22-03 (Rev.00)             14 / 28     HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1             FCC ID: WHBMBDASHCAMF


   1 GHz – 18 GHz




   18 GHz – 40 GHz




    F-TP22-03 (Rev.00)             15 / 28     HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1             FCC ID: WHBMBDASHCAMF


   40 GHz – 100 GHz




    F-TP22-03 (Rev.00)             16 / 28     HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                                 FCC ID: WHBMBDASHCAMF



    ▣ FIELD STRENGTH OF FUNDAMENTAL TEST RESULTS

    Low Channel
Frequency       Reading     A.F.+C.L.     Ant. Pol.       D.E.F          Duty           Total       Limit     Margin   Measurement

  [GHz]        [dBuV/m]         [dB]      경기도
                                           [H/V]      여주군[dB]      Cycle Factor (dB)   [dBuV/m]    [dBuV/m]    [dB]       Type

24.194822        71.52       44.82 가남면 V상활리 584-9.54                      -             106.80      127.96    21.16       PK
24.194822        57.50       44.82 번지 우)469-880
                                       V                  -9.54        12.80            105.58      107.96     2.38       AV
                                                       Tel:

    Mid Channel                        0337-885-0072,3    /

Frequency       Reading     A.F.+C.L.Fax:Ant.
                                         0337-885-0074
                                              Pol.   D.E.F               Duty           Total       Limit     Margin   Measurement

  [GHz]        [dBuV/m]         [dB]  경기도
                                        [H/V] 여주군[dB]              Cycle Factor (dB)   [dBuV/m]    [dBuV/m]    [dB]       Type

24.203371        71.20             E-mail
                             44.82 가남면 V상활리 584-9.54:                     -             106.48      127.96    21.48       PK
                                   koces@kornet.net
24.203371        57.48       44.82 번지 우)469-880
                                          V         -9.54              12.80            105.56      107.96     2.40       AV
                                                       Tel:

    High Channel                       0337-885-0072,3    /

Frequency       Reading     A.F.+C.L.Fax:Ant.
                                         0337-885-0074
                                              Pol.   D.E.F               Duty           Total       Limit     Margin   Measurement

  [GHz]        [dBuV/m]         [dB]  경기도
                                        [H/V] 여주군[dB]              Cycle Factor (dB)   [dBuV/m]    [dBuV/m]    [dB]       Type

24.215578        71.60             E-mail
                             44.82 가남면 V상활리 584-9.54:                     -             106.88      127.96    21.08       PK
                                   koces@kornet.net
24.215578        57.50       44.82 번지 우)469-880
                                          V         -9.54              12.80            105.58      107.96     2.38       AV
    ※     A∙F: ANTENNA FACTOR                          Tel:

          C∙L: CABLE LOSS              0337-885-0072,3    /
    Note :                             Fax: 0337-885-0074
    1. Total = Reading Value + Antenna Factor + Cable Loss + Distance Factor + Duty Cycle Factor
    2. Distance extrapolation factor
                               E-mail= 20 log (test :distance / specific distance) (dB)
    3. Measured Distance : 1 mkoces@kornet.net
    4. We have done x, y, z planes in EUT and horizontal and vertical polarization in detecting antenna.




     F-TP22-03 (Rev.00)                                  17 / 28                                   HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                        FCC ID: WHBMBDASHCAMF


   ▣ RESULT PLOTS


                   Fundamental Field Strength plot (Peak - Vertical)_Low Channel




                 Fundamental Field Strength plot (Average - Vertical)_Low Channel




    F-TP22-03 (Rev.00)                     18 / 28                         HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                        FCC ID: WHBMBDASHCAMF



                   Fundamental Field Strength plot (Peak - Vertical)_Mid Channel




                 Fundamental Field Strength plot (Average - Vertical)_Mid Channel




    F-TP22-03 (Rev.00)                     19 / 28                          HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                        FCC ID: WHBMBDASHCAMF



                  Fundamental Field Strength plot (Peak - Vertical)_High Channel




                 Fundamental Field Strength plot (Average - Vertical)_High Channel




    F-TP22-03 (Rev.00)                     20 / 28                          HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                 FCC ID: WHBMBDASHCAMF


   ▣ FIELD STRENGTH OF HARMONICS and RADIATED SPURIOUS EMISSIONS TEST RESULTS
   9 kHz – 30MHz
   Operation Mode: Continuous TX Mode
    Frequency     Reading     Ant. factor   Cable loss    Ant. POL       Total          Limit   Margin
       MHz        dBuV/m        dBm/m         dBm          (H/V)      dBuV/m       dBuV/m        dB
                                            No Critical peaks found


   Notes:
   1. Measuring frequencies from 9 kHz to the 30MHz.
   2. The reading of emissions are attenuated more than 20 dB below the permissible
     limits or the field strength is too small to be measured.
   3. Distance extrapolation factor = 40 log (specific distance / test distance) (dB)
   4. Limit line = specific Limits (dBuV) + Distance extrapolation factor
   5. We have done x, y, z planes in EUT and horizontal and vertical polarization in detecting antenna.
   6. The test results for below 30 MHz is correlated to an open site.
     The result on OATS is about 2 dB higher than semi-anechoic chamber(10 m chamber)




    F-TP22-03 (Rev.00)                          21 / 28                                 HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                              FCC ID: WHBMBDASHCAMF


   TEST RESULTS


   Below 1 GHz
   Operation Mode: Continuous TX Mode
    Frequency    Reading    Ant. factor   Cable loss    Ant. POL    Total        Limit       Margin
      MHz         dBuV/m      dBm/m         dBm          (H/V)      dBuV/m      dBuV/m         dB
                                          No Critical peaks found


   Notes:
   1. Measuring frequencies from 30 MHz to the 1 GHz.
   2. Radiated emissions measured in frequency range from 30 MHz to 1000 MHz were made
     with an instrument using Quasi peak detector mode.
   3. We have done x, y, z planes in EUT and horizontal and vertical polarization in detecting antenna.




    F-TP22-03 (Rev.00)                        22 / 28                             HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                     FCC ID: WHBMBDASHCAMF


   1 GHz – 18 GHz
   Operation Frequency: Continuous TX Mode
                                A.F.+C.L.-AMP G

       Frequency     Reading         +D.F.        ANT. POL        Total      Limit      Margin   Measurement

         [MHz]      [dBuV/m]        [dBm]    경기도 [H/V]
                                                    여주군          [dBuV/m]   [dBuV/m]     [dB]       Type

                                         가남면
                                           No 상활리       584 found
                                              Critical peaks
   ※    A∙F: ANTENNA FACTOR              번지 우)469-880
        C∙L: CABLE LOSS                                 Tel:
        AMP G: AMPLIFIER GAIN
                                         0337-885-0072,3     /
                                         Fax: 0337-885-0074
   Notes:
   1. Measuring frequencies from 1 GHz to the 10th harmonic of highest fundamental frequency.
                                         E-mail              :
   2. Measurements above show only up to 6 maximum emissions noted, or would be lesser if
                                         koces@kornet.net
       no specific emissions from the EUT are recorded (ie: margin > 20 dB from the applicable
       limit) and considered that's already beyond the background noise floor.
   3. Radiated emissions measured in frequency above 1000MHz were made with an
       instrument using Peak detector mode and average detector mode of the emission shown
       in Actual FS column.
   4. Total = Reading Value + Antenna Factor + Cable Loss – Amplifier Gain + Distance Factor
   5. We have done x, y, z planes in EUT and horizontal and vertical polarization in detecting antenna.
   6. Measurement distance : 1 m




    F-TP22-03 (Rev.00)                            23 / 28                              HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                    FCC ID: WHBMBDASHCAMF


   18 GHz – 40 GHz
   Operation Frequency: Continuous TX Mode
   Front
    Frequency       Reading   A.F.+C.L.     Ant. Pol.          D.E.F    Total      Limit     Margin   Measurement

        [GHz]      [dBuV/m]      [dB]      경기도
                                            [H/V]       여주군[dB]        [dBuV/m]   [dBuV/m]    [dB]       Type

       *24.000       35.19      44.82 가남면 V상활리 584-9.54                 70.47       74        3.53       PK
       *24.000        6.73      44.82 번지 우)469-880
                                          V                    -9.54    42.01       54       11.99       AV
       *24.250       34.35      44.82            V       Tel:-9.54      69.63       74        4.37       PK
       *24.250        8.94      44.82 0337-885-0072,3
                                             V          /
                                                        -9.54           44.22       54        9.78       AV
   ※    A∙F: ANTENNA FACTOR
                                      Fax: 0337-885-0074

        C∙L: CABLE LOSS
                                        E-mail                 :
   Note :                               koces@kornet.net

   1. Total = Reading Value + Antenna Factor + Cable Loss + Distance Factor
   2. Distance extrapolation factor = 20 log (test distance / specific distance) (dB)
   3. Measured Distance : 1 m
   4. We have done x, y, z planes in EUT and horizontal and vertical polarization in detecting antenna.
       Worst case is y plane and vertical polarization.
   5. ‘*’ is band edge frequency.




    F-TP22-03 (Rev.00)                               24 / 28                               HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                   FCC ID: WHBMBDASHCAMF


   40 GHz – 100 GHz
   Operation Frequency: Continuous TX Mode
                                                        Conversion
                                                                                                     Measurement
    Frequency     Reading      AFCL        Ant. Pol.         Factor    Total      Limit     Margin
                                                                                                        Type
      [GHz]        [dBm]        [dB]      경기도
                                           [H/V]       여주군[dB]        [dBuV/m]   [dBuV/m]    [dB]
                                       가남면 No
                                            상활리
                                              Critical584
                                                       peaks found
                                       번지 우)469-880

   Note :                                               Tel:
                                 0337-885-0072,3
   1. Total(dBuV/m) = Reading Value(dBm)         / + Conversion Factor(dB)
                                         + AFCL(dB)
     (cf. ANSI C63.10_2013 sectionFax:
                                   9.5)0337-885-0074
   2. Distance extrapolation factor = 20 log (test distance / specific distance) (dB)
                                     – 60 GHz), 1 m(60
                                  E-mail
   3. Measured Distance : 1 m(40 GHz              :    GHz – 100 GHz)
   4. We have done x, y, z planes inkoces@kornet.net
                                     EUT and horizontal and vertical polarization in detecting antenna.
     Worst case is y plane and horizontal polarization.
   5. In this test, AFCL factor consists of antenna factor, cable loss, mixer loss, amplifier gain
   6. Conversion Factor = 20 log(D)-104.77 = 95.2 dB(where, distance is 3 m.)
   7. Because of no critical emissions are detected in the test, only peak value is recorded in this
   report.




    F-TP22-03 (Rev.00)                             25 / 28                                HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                       FCC ID: WHBMBDASHCAMF


   ▣ RESULT PLOTS
                                      Band Edge Plot(peak, x-V)




                                    Band Edge Plot(average, x-V)




   Note : Only the worst case plots for Radiated Spurious Emissions.



    F-TP22-03 (Rev.00)                        26 / 28                    HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                                  FCC ID: WHBMBDASHCAMF



   9. LIST OF TEST EQUIPMENT
                                                                           Calibration   Calibration
                     Manufacturer                  Model / Equipment                                        Serial No.
                                                                              Date        Interval

           Agilent                  N9030B / PXA Signal Analyzer           08/29/2018     Annual          MY55480167

           Schwarzbeck              BBHA 9170 / Horn Antenna               12/04/2017     Biennial        BBHA9170541

           Innco system             CO3000 / Controller(Antenna mast)         N/A           N/A            CO3000-4p
                                    MA4640/800-XP-EP /
           Innco system                                                       N/A           N/A                N/A
                                    Antenna Position Tower
           Rohde&Schwarz            FSW / Spectrum Analyzer                09/27/2018     Annual             101256

           Rohde&Schwarz            FSP / Spectrum Analyzer                09/19/2018     Annual           836650/016

           Emco                     2090 / Controller                         N/A           N/A              060520

           Ets                      Turn Table                                N/A           N/A                N/A

           Rohde & Schwarz          Loop Antenna                           01/18/2019     Biennial          1513-175

           Schwarzbeck              VULB 9168 / Hybrid Antenna             08/31/2020     Biennial         9168-0895

           Schwarzbeck              BBHA 9120D / Horn Antenna              06/30/2017     Biennial         9120D-1300

           OML INC.                 WR-19 Horn Antenna / Horn Antenna         N/A           N/A            18042301

           OML INC.                 WR-19 Horn Antenna / Horn Antenna         N/A           N/A            18042302

           OML INC.                 WR-12 Horn Antenna / Horn Antenna         N/A           N/A            18042301

           OML INC.                 WR-12 Horn Antenna / Horn Antenna         N/A           N/A            18042302

           OML INC.                 WR-08 Horn Antenna / Horn Antenna         N/A           N/A            18050101

           OML INC.                 WR-08 Horn Antenna / Horn Antenna         N/A           N/A            18050102

           OML INC.                 OML WR19 / Harmonic Mixer              09/26/2017     Annual           W19HWD

           OML INC.                 OML WR12 / Harmonic Mixer              09/26/2017     Annual           W12HWD

           OML INC.                 OML WR08 / Harmonic Mixer              09/26/2017     Annual           W08HWD

           OML INC.                 WR-19 / Source Module                  09/26/2017     Annual        S19MS-A-160516-1

           OML INC.                 WR-12 / Source Module                  09/26/2017     Annual        S12MS-A-160419-1

           OML INC.                 WR-08 / Source Module                  09/26/2017     Annual        S08MS-A-160419-1

           OML INC.                 Diplexer L.O / Diplexer                07/24/2018     Annual        DPL518-160419-1

           CERNEX                   CBLU1183540 / Power Amplifier          07/10/2018     Annual             22964

           CERNEX                   CBL26405040 / Power Amplifier          06/29/2018     Annual             25956


   Note:

   1. Equipment listed above that calibrated during the testing period was set for test after the calibration.
   2. Equipment listed above that has a calibration due date during the testing period, the testing is completed
   before equipment expiration date.




    F-TP22-03 (Rev.00)                                           27 / 28                               HCT CO.,LTD.


Report No.: HCT-RF-1905-FC006-R1                                                 FCC ID: WHBMBDASHCAMF




   10. ANNEX A_TEST SETUP PHOTO

   Please refer to test setup photo file no. as follows;

         No.                                                    Description

           1                                               HCT-RF-1905-FC006-P




    F-TP22-03 (Rev.00)                               28 / 28                       HCT CO.,LTD.



Document Created: 2019-05-08 22:25:16
Document Modified: 2019-05-08 22:25:16

© 2024 FCC.report