Test Report

FCC ID: WHBARUTR

Test Report

Download: PDF
FCCID_3214175

                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP




             FCC RADIO TEST REPORT
                  FCC 47 CFR PART 15 SUBPART C
 Test Standard                     FCC Part 15.249(a)
 FCC ID                            WHBARUTR
 Trade name                        AUDI
 Product name                      UTR (Universal Traffic Recorder)
 Model No.                         UTR (Universal Traffic Recorder)
 Test Result                       Pass


The test Result was tested by Compliance Certification Services Inc. The test data, data
evaluation, test procedures, and equipment configurations shown in this report were
given in ANSI C63.10: 2013 and compliance standards.
The test results of this report relate only to the tested sample (EUT) identified in this
report.
The test Report of full or partial shall not copy. Without written approval of CCS. lnc.

The sample selected for test was production product and was provided by manufacturer.




Approved by:                                                     Reviewed by:




Sam Chuang                                                       Zeus Chen
Manager                                                          Supervisor




                                                         Page 1 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                             Report No.: T160920D22-RP




                                       Revision History
Rev.           Issue Date                                       Revisions                              Revised By
 00         November 24, 2016                                  Initial Issue                          Angel Cheng




                                                        Page 2 / 30                                                Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                    Compliance Certification Services Inc.
                                                                                                       Report No.: T160920D22-RP




                                           Table of contents
1. GENERAL INFORMATION .................................................................................................. 4

      1.1    EUT INFORMATION .................................................................................................. 4

      1.2    EUT CHANNEL INFORMATION ................................................................................ 5

      1.3    ANTENNA INFORMATION ........................................................................................ 5

      1.4    MEASUREMENT UNCERTAINTY.............................................................................. 6

      1.5    FACILITIES AND TEST LOCATION .......................................................................... 7

      1.6    INSTRUMENT CALIBRATION ................................................................................... 7

      1.7    SUPPORT AND EUT ACCESSORIES EQUIPMENT ................................................. 8

2. TEST SUMMERY ................................................................................................................. 9

3. DESCRIPTION OF TEST MODES ..................................................................................... 10

      3.1    THE WORST MODE OF OPERATING CONDITION ................................................ 10

      3.2    THE WORST MODE OF MEASUREMENT .............................................................. 10

4. TEST RESULT ................................................................................................................... 11

4.1 FIELD STRENGTH OF FUNDAMENTAL AND SPURIOUS EMISSION ............................ 11
APPENDIX 1 - PHOTOGRAPHS OF EUT




                                                          Page 3 / 30                                                Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP



1. GENERAL INFORMATION
1.1 EUT INFORMATION
                                 Mobile Appliance, Inc.
                                 401, simin-daero, Dongan-gu, #1701-1706, Daerung Techno
Applicant
                                 Town 15, Gwanyang-dong, Anyang-si, Gyeonggi-do, 14057,
                                 South Korea
Equipment                        UTR (Universal Traffic Recorder)

Model Name                       UTR (Universal Traffic Recorder)

Model Discrepancy                N/A

EUT Functions                    24G Radar

Received Date                    September 20, 2016

Date of Test                     Nov. 22, 2016 ~ Nov. 24, 2016
                                 Peak : 120.29 dBuV/m
Output Power
                                 Average : 109.12 dBuV/m

                                      AC
                                      DC Type :
Power Operation                          Battery
                                         DC Power Supply : 12V
                                         External DC adapter

Remark:
All listed models are using an identical RF module with the only differences on number of
key buttons mounted for additional functions.
Due to similarity of RF product constructions of given model series, only dedicated
model as described in test report with the most complexity constructions was selected
for testing and record.




                                                         Page 4 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                             Report No.: T160920D22-RP



1.2 EUT CHANNEL INFORMATION
Frequency Range                          24.00GHz-24.25GHz


Modulation Type                          CW


Number of channel                        1

1.3 ANTENNA INFORMATION
                                                                 Integral: antenna permanently attached
Antenna Category                                                 External dedicated antennas
                                                                 External Unique antenna connector

                                                                 PIFA
                                                                 PCB
Antenna Type                                                     Dipole
                                                                 Printed
                                                                 Coils

Antenna Gain                                                9.5 dBi




                                                        Page 5 / 30                                                Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP



1.4 MEASUREMENT UNCERTAINTY
                    PARAMETER                                      UNCERTAINTY
AC Powerline Conducted Emission                                         +/- 1.2575
Emission bandwidth, 20dB bandwidth                                      +/- 1.4003
RF output power, conducted                                              +/- 1.1372
Power density, conducted                                                +/- 1.4003
3M Semi Anechoic Chamber / 30M~200M                                     +/- 4.0138
3M Semi Anechoic Chamber / 200M~1000M                                   +/- 3.9483
3M Semi Anechoic Chamber / 1G~8G                                        +/- 2.5975
3M Semi Anechoic Chamber / 8G~18G                                       +/- 2.6112
3M Semi Anechoic Chamber / 18G~26G                                      +/- 2.7389
3M Semi Anechoic Chamber / 26G~40G                                      +/- 2.9683
3M Semi Anechoic Chamber / 40G~60G                                      +/- 1.8509
3M Semi Anechoic Chamber / 60G~75G                                      +/- 1.9869
3M Semi Anechoic Chamber / 75G~110G                                     +/- 2.9651
3M Semi Anechoic Chamber / 110G~170G                                    +/- 2.7807
3M Semi Anechoic Chamber / 170G~220G                                    +/- 3.6437
3M Semi Anechoic Chamber / 220G~325G                        +/- 4.2982
Remark:
1.This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2
2. ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the
emissions test results be included in the report.




                                                         Page 6 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                  Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP



1.5 FACILITIES AND TEST LOCATION
All measurement facilities used to collect the measurement data are located at
No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.)

               Test site                                     Test Engineer                        Remark
          AC Conduction Room                                      -                                 -
               Radiation                                      Kevin Kuo                             -
             RF Conducted                                         -                                 -
Remark: The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and
CISPR Publication 22.

1.6 INSTRUMENT CALIBRATION
                                            3M 966 Chamber Test Site

   Equipment               Manufacturer                     Model                       S/N                Cal Due

Spectrum Analyzer               Agilent                    E4446A                 US42510252              12/07/2016

    Loop Ant               COM-POWER                        AL-130                    121051              02/24/2017

  Bilog Antenna            Sunol Sciences                     JB3                    A030105              07/02/2017

  Pre-Amplifier                 EMEC                        EM330                     60609               06/07/2017

  Horn Antenna                   ETC                     MCTD 1209               DRH13M02003              09/01/2017

  Pre-Amplifier                MITEQ              AMF-6F-260400-40-8P                 985646              01/13/2017

   Horn Antenna                 EMCO                         3116                     26370               01/14/2017
  Harmonic Mixer           A-INFO /                                               J202020872 /
                                                    LB-19-20-A / FS-Z60                                   04/16/2017
 40GHz - 60GHz         ROHDE&SCHWARZ                                                 100142
  Harmonic Mixer
                       ROHDE&SCHWARZ                FH-PP-75 / FS-Z75            10001 / 100162           04/21/2017
 50GHz - 75GHz
  Harmonic Mixer
                       ROHDE&SCHWARZ               FH-PP-110 / FS-Z110           10003 / 100096           04/23/2017
 75GHz - 110GHz
  Harmonic Mixer
                       ROHDE&SCHWARZ               FH-PP-170 / SAM-170            10003 / 20011           04/26/2017
110GHz - 170GHz
  Harmonic Mixer
                       ROHDE&SCHWARZ               FH-PP-220 / SAM-220            10003 / 20013           04/29/2017
140GHz - 220GHz
  Harmonic Mixer        Radiometer Physics
                                                   FH-PP-325 / SAM-325            10007 / 20048           05/04/2017
220GHz - 325GHz               Gmbn
 Antenna Tower                   CCS                       CC-A-1F                      N/A                  N.C.R

    Controller                   CCS                       CC-C-1F                      N/A                  N.C.R
   Turn Table                    CCS                       CC-T-1F                      N/A                  N.C.R
Remark: Each piece of equipment is scheduled for calibration once a year and harmonic mixer twice a
year.




                                                         Page 7 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP



1.7 SUPPORT AND EUT ACCESSORIES EQUIPMENT
                                          EUT Accessories Equipment
 No.            Equipment                 Brand            Model                Series No.                 FCC ID
                     N/A

                                                Support Equipment
 No.            Equipment                 Brand             Model               Series No.                 FCC ID
  1         DC Power Source            GWINSTEK           SPS-3610                  N/A                       N/A

1.8 Test methodology and applied standards
The test methodology, setups and results comply with all requirements in accordance
with ANSI C63.10:2013, FCC Part 15.249.
1.9 Table of accreditations and listings
 Country Agency Scope of Accreditation                                                           Logo

                           3M Semi Anechoic Chamber (FCC MRA: TW1039) to perform
 USA          FCC
                           FCC Part 15 measurements
                                                                                                 FCC MRA: TW1039

              Industry     3M Semi Anechoic Chamber (IC 2324G-1 / IC 2324G-2) to
 Canada                                                                                          IC 2324G-1
              Canada       perform
                                                                                                 IC 2324G-2



        .




                                                         Page 8 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                             Report No.: T160920D22-RP



2. TEST SUMMERY
FCC Standard               Report
                                                                   Test Item                                Result
   Section                 Section
   15.203                    1.2                         Antenna Requirement                                  Pass
  15.249(a)                  4.1                     Filed strength of fundamental                            Pass
  15.249(a)                  4.1                     Radiation Spurious Emission                              Pass




                                                        Page 9 / 30                                                Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP



3. DESCRIPTION OF TEST MODES
3.1 THE WORST MODE OF OPERATING CONDITION

Operation mode                                              24 GHz




Test Channel Frequencies                                    24.08GHz



3.2 THE WORST MODE OF MEASUREMENT
                                 AC Power Line Conducted Emission
  Test Condition                  AC Power line conducted emission for line and neutral
     Voltage/Hz                                                     120V/60Hz
      Test Mode                     N/A
    Worst Mode                      Mode 1            Mode 2           Mode 3            Mode 4

                           Radiated Emission Measurement Above 1G
  Test Condition                   Band edge, Emission for Unwanted and Fundamental
     Voltage/Hz                                                     120V/60Hz
      Test Mode                     Mode 1:EUT power by DC Source.
    Worst Mode                      Mode 1       Mode 2     Mode 3       Mode 4
                                    Placed in fixed position.
                                    Placed in fixed position at X-Plane (E2-Plane)
  Worst Position
                                    Placed in fixed position at Y-Plane (E1-Plane)
                                    Placed in fixed position at Z-Plane (H-Plane)
   Worst Polarity                   Horizontal     Vertical

                            Radiated Emission Measurement Below 1G
  Test Condition                                      Radiated Emission Below 1G
     Voltage/Hz                                                     120V/60Hz
      Test Mode                     Mode 1:EUT power by DC Source.
    Worst Mode                      Mode 1            Mode 2           Mode 3            Mode 4

Remark:
1. The worst mode was record in this test report.
2. EUT pre-scanned in three axis ,X,Y, Z and two polarity, Horizontal and Vertical for
radiated measurement. The worst case(X-Plane and Horizontal) were recorded in this
report
                                                         Page 10 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP



4. TEST RESULT
4.1 FIELD STRENGTH OF FUNDAMENTAL AND SPURIOUS
    EMISSION
4.1.1 Test Limit
According to §15.249(a)
(1) The field strength of emissions from intentional radiators operated within these
frequency bands shall comply with the following:
          Fundamental                            Field strength of                        Field strength of
           frequency                               fundamental                               harmonics
             (MHz)                               (millivolts/meter)                      (microvolts/meter)
         2400-2483.5                                      50                                       500
          5725-5875                                       50                                       500
         24000-24250                                     250                                      2500
* Field strength limits are specified at a distance of 3 meters

                                      Fundamental Limit Conversion
       Average                       Average              Average                                    Peak
       (mV/m)                       (dBuV/m)             (dBuV/m)                                  (dBuV/m)
        at 3M                         at 3M                at 1M                                     at 1M
         250                        107.9588              117.50                                    137.50
*(Limit=107.9588+20LOG(3/1)=117.50 dBuV/m)

                                        Harmonic Limit Conversion
       Average                       Average              Average                                    Peak
        (uV/m)                      (dBuV/m)             (dBuV/m)                                  (dBuV/m)
         at 3M                        at 3M                at 1M                                     at 1M
         2500                        67.9588               77.50                                     97.50
*(Limit=67.9588+20LOG(3/1)=77.50 dBuV/m)




                                                         Page 11 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                               Report No.: T160920D22—RP




(2) Emissions radiated outside of the specified frequency bands, except for harmonics,
shall be attenuated by at least 50 dB below the level of the fundamental or to the general
radiated emission limits in §15.209(follow the table}, whichever is the lesser attenuation
Below 30 MHz


     Frequency                     Reuswengn                           ‘hiky
                                                                {microamperes/m)
                                                                                                    "aeure"
                                                                                                       ({metres)
     9—490 kHz                 2,400/F (F in kHz)                2,400/F (F in kHz)                       300
   490—1,705 kHz              24,000/F (F in kHz)                24,000/F (F in kHz)                       30
   1.705—30 MHz                          30                                N/A                             30

30
                                                                    Field Strength
       Frequency                                  microvolts/m at 3 metres (watts, e.i.r.p.)
           (MHz)                                Transmitters                                   Receivers
           30—88                                 100 (3 nw)                                    100 (3 nw)
          88—216                                150 (6.8 nW)                                  150 (6.8 nW)
         216—960                                200 (12 nW)                                   200 (12 nW)
        Above 960                               500 (75 nW)                                   500 (75 nW)

4.1.2 Test Procedure
1. The EUT is placed on a turntable, Above 1 GHz is 1.5m, below 1 GHz and above 40G
is 0.8m above ground plane. The EUT Configured un accordance with ANSI C63.10, and
the EUT set in a continuous mode.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
emission level. And EUT is set 3m away from the receiving antenna, which is scanned
from 1m to 4m above the ground plane to find out the highest emissions. Measurement
are made polarized in both the vertical and the horizontal positions with antenna.
3. The SA setting following :
  (1) Below 1G : RBW = 100kHz, VBW z> 3 RBW, Sweep = Auto, Detector = Peak,

  (2) Above 1G :
      (2.1) For Peak measurement : RBW = 1MHz, VBW > 3 RBW.
      (2.2) For Average measurement : RBW = 1MHz, VBW =10Hz.




                                                        Page 127 30                                                Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22-RP


4.1.3 Test Setup
9kHz ~ 30MHz




                              3m
                                                                                       Loop antenna
       EUT

                                                                                    Spectrum /
                                                                                     Receiver


              Turntable                   1m
                            0.8m




   Reference ground plane

30MHz ~ 1GHz

                                                                                     Antenna
                                                                                      tower


                              3m                                                     Bi-log
                                                                                    antenna
       EUT
                                     4m
                                                                                   Spectrum
                                                                                   analyzer


              Turntable                   1m
                            0.8m




   Reference ground plane




                                                        Page 13 / 30                                               Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                               Report No.: T160920D22—RP



Above 1 GHz

                                                                             Antenna
                                                              .               tower




                                                           ————              I-iom
  EUT _\                                                                    antenna




                                                                             Spectrum
                                                                             analyzer


       Turntable                                                  S
                                                                                                 ©o

                                                                                   Pre—amp   -\Q % E
                                                                     1         L                        1




Above 40 GHz



                                   Fundamental or
                                   Harmonic Mixer

          Input from Test                                                Spectrum
              Fixture                                                    Analyser




                                         Local
                                       Oscillator
                                        Source
                                                                         Data Store




                                                      ma                                                         ma
                                                        Page 14 / 30                                               Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf              2 Compliance Certification Services Inc.
                                                                                                  Report No.: T160920D22—RP



4.1.4 Test Result
   Fre                   Peak            Average                    Peak                Average
   (GH‘i')               Value            Value                     Limit                 Limit                 Result
                        (dBuV/m)         (dBuV/m)             (dBuV/m)                  (dBuV/m)
   24.04                 120.29           109.12                137.50                   117.50                  Pass

Test Data
{1) Filed strength of fundamental :
    Test Mode:                           TX—24GHz                           Temp/Hum               27(°C)/ 53%RH
     Test Item                         Fundamental                       Test Date                  Nov 24, 2016
       Axis                              X—Plane                       Test Engineer                 Kevin Kuo
     Detector                             Peak                         Test Voltage:                   12Vde

      Spectrum                                                                                                       (€)
       RefLevel 150.38 dBpV        Offset 23.38 db @ RBW    1 MHz
    e Att                  30 de @ SWT     500 ms @ VBW 3 MHz         Mode Auto Sweep
     @ 1?k View
                                                                            Miji]                       120.29 dBu¥y
                                                                                                     24.0851740 GHz
      140 dBpy

      130 dBpy

      120 dBpy

      110 dbpy

      100



     90 dBpy


     80 dBpy


     70 dBpy

     60 dBpy


     CF 24.0861 C Hz                                    691 pts                                       Span 20.0 MHz

                   ]|                                                  Measuring...                       24102018
                                                                                                           seurit     //

    Date: 24.NOV . 2016     O6:11:11




                                                       me                                                             me
                                                         Page 15 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                             Report No.: T160920D22—RP




   Test Mode:                          TX—24GHz                      Temp/Hum                  27(‘C)/ 53%RH
    Test Item                        Fundamental                      Test Date                  Nov 24, 2016
     Polarize                          Vertical                     Test Engineer                    Kevin Kuo
    Detector                           Average                       Test Voltage:                      12Vde

     Spectrum                                                                                                      &
      RefLevel 150.38 dBpV      Offset 23.3 db @ RBW        1 MHz
   e Att                 30 de @ SWT     500 ms @ VBW 3 MHz         Mode Auto Sweep
    (@ 12m View
                                                                      Miji]                             109.12 dBuy
                                                                                                     24.0846530 GHz
     140 dBpy

     130 dBpy

     120 dBpy

                                                  M1
     110 dBpy

     100 dbpy

    90 dBpy
    __———

    80 dBpy


    70 dapy

    60 dBpy


    CF 24.0861 CHz                                      691 pts                                      Span 20.0 MHz
                                                                                                         PiLzols
                  J\                                                Neasuring...   OW        dipth        oodiar   %
   Date:   24.NOV.2016    O6:11:42




                                                       me                                                            me
                                                        Page 16 / 30                                               Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                          Report No.: T160920D22—RP




(2) Below 1G :
    Test Mode:                        TX—24GHz                                 Temp/Hum                    27(°C)/ 53%RH
     Test Item                       3O0MHz—1GHz                                Test Date                   Nov 22, 2016
      Polarize                           Vertical                           Test Engineer                     Kevin Kuo
      Detector                     Peak and Qusi—peak                       Test Voltage:                       12Vde

     80.0   dBu¥/m
                                                                                                            Limi]:       —
                                                                                                            Margin:      —




      4I]_|
                I—lz                                                                 5
                1                    3                       4                                        6




     0.0
       30.000   127.00    224.00      321.00          418.00     515.00     612.00   709.00      806.00               1000.00 MHz




                               :           Correct                                        Inai                 .
   Frequency             Reading                                   Result                Limit            Margin
      (MH2)              (dBuy)                (';aé’/‘:")        (dBuV/m)           (dBuV/m)              (dB)            Remark
    95.9600              52.04                 —20.03               32.01                43.50            —11.49             peak

    161.9200             50.09                 —16.45               33.64                43.50            —9.86              peak
    288.0200             46.16                 —14.46               31.70                46.00            —14.30             peak
    431.5800             40.06                 —10.75               29.31                46.00            —16.69             peak

    683.7800             41.02                  —6.23               34.79                46.00            411.21             peak
    828.3100             35.10                  —4.09               31.01                46.00            —14.99             peak




                                                                 Page 177 30                                                    Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                               Report No.: T160920D22—RP




   Test Mode:                             TX—24GHz                                Temp/Hum                      27(°C)/ 53%RH
    Test Item                            3O0MHz—1GHz                               Test Date                     Nov 22, 2016
     Polarize                              Horizontal                          Test Engineer                        Kevin Kuo
     Detector                          Peak and Qusi—peak                      Test Voltage:                          12Vde

    80.0   dBu¥/m
                                                                                                                 Limit]       —
                                                                                                                 Margin:      —




     4l]_|

               1        23                     4                                                  6




    0.0
      30.000   127.00         224.00      321.00          418.00   515.00      €12.00   709.00        806.00               1000.00 MHz




                                   :           Correct                                     Inai                     .
  Frequency                  Reading                                  Result             Limit                 Margin
     (MH2)                   (dBuy)                (';a;/‘:‘r)      (dBuV/m)            (dBuV/m)                (dB)            Remark
   95.9600                   51.13                 —20.03             31.10              43.50                 1240               peak

   150.2800                  48.92                 —16.08             32.84              43.50                 —10.66             peak
   161.9200                  48.87                 16.45              32.42              43.50                 11.08              peak
   342.3400                  44.93                 13.10              31.83              46.00                 14.17              peak
   393.7500                  36.94                 —11.85             25.09              46.00                 —20.91             peak

   745.8600                  37.85                  —5.02             32.83              46.00                 13.17              peak




                                                                   Page 18 7 30                                                      Revoo
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESF            2 Compliance Certification Services Inc.
                                                                                                               Report No.: T160920D22—RP




(2) Above 1G :
    Test Mode:                       TX—24GHz                               Temp/Hum                            27(°C)/ 53%RH
     Test Item                      1GHz—18GHz                               Test Date                           Nov 22, 2016
      Polarize                         Vertical                           Test Engineer                             Kevin Kuo
      Detector                    Peak and Average                        Test Voltage:                               12Vde

    110.0   dBu¥/m
                                                                                                                 Limi]:       —
                                                                                                                 Limit2:      —




      70




                                                                                                3


            2




    30.0
       1000.000.2700.00             6100.00      7600.00                  17200.00   12900.00       14600.00               18000.00 MHz




                              :          Correct                                        Inai                        .
   Frequency              Reading                                Result               Limit                    Margin
      (MH2)                               (';aé’/‘:")           (dBuV/m)             (dBuV/m)                   (dB)             Remark
    1448.000                               —6.37                 43.45                97.50                    —54.05             peak

    1553.000                               —5.92                 46.33                97.50                    —51.17             peak
   14060.000                              22.19                  57.16                97.50                    ~40.34             peak




                                                           me                                                                         me
                                                         Page 19 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                            Report No.: T160920D22—RP




   Test Mode:                        TX—24GHz                              Temp/Hum                         27(°C)/ 53%RH
    Test Item                       1GHz—18GHz                             Test Date                          Nov 22, 2016
     Polarize                         Horizontal                        Test Engineer                           Kevin Kuo
     Detector                     Peak and Average                       Test Voltage:                                 12Vde

   110.0   dBu¥/m
                                                                                                              Limit:       —
                                                                                                              Limit®:      —




    70




                                                                                             3



                                              2


           1

   30.0    T
     1000.000 2700.00   4400.00    €100.00        7800.00   9500.00    17200.00   12900.00       14600.00               18000.00 MHz




                             :          Correct                                      Imat                        .
  Frequency             Reading                               Result               Limit                Margin
     (MH2z)             (dBuy)           Factor
                                         (dB/m)             (dBuV/m)              (dBuV/m)                  (dB)             Remark
   1553.000             45.32                —5.92            39.40                97.50                —58.10                 peak
   6971.000             35.66                11.87            47.53                97.50                ~49.97                 peak

  14030.000             34.95            22.20                57.15                97.50                ~40.35                 peak




                                                            Page 20 7 30                                                               Revoo
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                               Report No.: T160920D22—RP




    Test Mode:                           TX—24GHz                             Temp/Hum                             27(°C)/ 53%RH
     Test Item                          18GHz—40GHz                            Test Date                            Nov 22, 2016
      Polarize                            Vertical                          Test Engineer                              Kevin Kuo
      Detector                       Peak and Average                       Test Voltage:                                12Vde

    110.0   dBu¥/m
                                                                                                                    Limit]       —
                                                                                                                    Limit2:      —




                                                                                                               5




                                                   q           4
      70                                               3
                     1




    30.0
       18000.000—20200.00    22400.00   24600.00   26800.00   29000.00      31200.00    33400.00—   35600.00                  40000.00 MHz




                                 i           Correct                                       Inai                        .
   Frequency                Reading                                Result                Limit                 Margin
      (MH2)                 (dBuy)            Factor
                                              (dB/m)           (dBuV/m)                (dBuV/m)                    (dB)             Remark
   20156.000                35.32             30.87                66.19                97.50                  —31.31                peak
   26180.000                36.66             34.11                70.77                97.50                  —26.73                peak

   27487.000                34.29             35.71                70.00                97.50                  —27.50                peak
   29219.000                34.86             36.50                71.36                97.50                  —26.14                peak

   37300.000                49.55             39.00                88.55                97.50                  —8.95                 peak



Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                              Page 217 30                                                                Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                                 Report No.: T160920D22—RP




    Test Mode:                           TX—24GHz                               Temp/Hum                          27(°C)/ 53%RH
     Test Item                          18GHz—40GHz                              Test Date                         Nov 22, 2016
      Polarize                            Horizontal                         Test Engineer                            Kevin Kuo
      Detector                       Peak and Average                         Test Voltage:                                 12Vde

    110.0   dBu¥/m
                                                                                                                   Limit]       —
                                                                                                                   Limit2:      —




                                                                                                             5




                                                                     4
      70                                           2        3

                     1




    30.0
       18000.000—20200.00    22400.00   24600.00       26800.00   29000.00    31200.00    33400.00—   35600.00               40000.00 MHz




                                 i           Correct                                         Inai                     .
   Frequency                Reading                                 Result                 Limit                 Margin
      (MH2)                 (dBuy)            Factor
                                              (dB/m)               (dBuV/m)              (dBuV/m)                 (dB)             Remark
   20076.000                33.63             30.87                  64.50                97.50                  —33.00             peak
   26004.000                35.99             33.90                  69.89                97.50                  —27.61             peak

   27228.000                35.05             34.98                  70.03                97.50                  —27 A7             peak

   28978.000                34.71             36.52                  71.23                97.50                  —26.27             peak
   36500.000                47.27             39.35                  86.62                97.50                  —10.88             peak



Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                                  Page 227 30                                                           Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                Report No.: T160920D22—RP




    Test Mode:                             TX—24GHz                       Temp/Hum               27(°C)/ 53%RH
     Test Item                           40GHz—60GHz                       Test Date              Nov 24, 2016
      Polarize                      Vertical/Horizontal                Test Engineer                  Kevin Kuo
      Detector                      Peak and Average                   Test Voltage:                    12Vde

      Spectrum                                                                                                       mvz
      ReflLevel 107.50 dbu¥        Offset 10.50 db @ RBW   1 MHz
                                   SWT      80 ms @ VBW 3 MHz        Mode Auto Swaap
      Exthix U
     @ 19k View
                                                                          Miji]                          54.94 dBuV
      100 dbpy                                                                                          47.2500 GHz
                         D2 96.500 dey
     20 dgpy

     80 dBpy
                  D1 76.500 dap

     70 dBpy


     60 dBpy
                                              M1

     VW«AWWMWWW                                                            fysvolfnsteashcl—n
     so dBpy

     40 dBpy

     30 dapy

     20 dBpy

     10 depy
     Start 40.0 GHz                                        691 pts                                    Stop 60.0 GHz

                                                                       Neasuring...   OW        dZh      24,112018
                   ] [                                                                                    osir0s       /

    Date: 24.N0V.2016         O5:11:07



Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
           fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                           Page 23 7 30                                                Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf              2 Compliance Certification Services Inc.
                                                                                                                  Report No.: T160920D22—RP




    Test Mode:                                TX—24GHz                                 Temp/Hum                    27(°C)/ 53%RH
     Test Item                              60GHz—75GHz                                 Test Date                   Nov 24, 2016
      Polarize                         Vertical/Horizontal                           Test Engineer                      Kevin Kuo
      Detector                         Peak and Average                              Test Voltage:                        12Vde

      Spectrum                                                                                                                      &
      RefLevel 111.50 dBu¥           Offset 10.50 dB @ RBW              1 MHz
                                     SWT        60 ms @ VBW 3 MHz                  Mode Auto Sweap
      ExtMix V
     @ 19k View
                                                                                       Miji]                               62.58 dBuy
                                                                                                                          67.5000 GHz
      100 dBpy
                        D2 97,500 dBy

     20 dBpy

     80 dBpy
                  D1 77.500 dap

     70 dBpy

     fendopy«      puodbkigls       on ut    inaststy lt h.   Legtave    audaine                     Mbatp   inssc in


     5o dBpy

     40 dBpy

     30 dBpy

     20 dBpy

     Start 60.0 CHz                                                     691 pts                                         Stop 75.0 GHz

                   J\                                                                Measuring...               B Wt       24112016
                                                                                                                             n6:37i14   /
    Date: 24.NOV . 2016         06:37:13




Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
           fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                                        me                                                              me
                                                                        Page 24 / 30                                                    Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                               Report No.: T160920D22—RP




    Test Mode:                          TX—24GHz                        Temp/Hum                 27(°C)/ 53%RH
     Test Item                      75GHz—110GHz                       Test Date                  Nov 24, 2016
      Polarize                     Vertical/Horizontal               Test Engineer                 Kevin Kuo
     Detector                      Peak and Average                  Test Voltage:                   12Vde

      Spectrum                                                                                                      mvz
      ReflLevel 119.50 dbu¥       Offset 11.50 db @ RBW   1 MHz
                                  SWT    140 ms @ VBW 3 MHz         Mode Auto Sweep
      ExtMix W
     @ 19k View
                                                                        Miji]                            68.19 dBpy
                                                                                                       99.0850 GHz
      110 dBp¥


      100 dBpV
                        D2 97.500 dBy

     20 dBpy

     so dgpy
                  D1 77.500 dap

     70 dBpy                                                                         M
     MWWMW«MWWNMWWWWM                                                                         rirtindcariousnalcunl
     60 dBpy


     so dBpy

     40 dBpy

     30 dBpy


     Start 75.0 GHz                                       691 pts                                   Stop 110.0 CHz
                   J(                                                NMeasuring...
                                                                             i       f@      D wG         im
                                                                                                         24112018     /
    Date:   24.NOV.2016     O5:13:13




Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
        fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                          Page 257 30                                                 Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf              2 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22—RP




    Test Mode:                              TX—24GHz                        Temp/Hum            27(°C)/ 53%RH
     Test Item                         110GHz—170GHz                         Test Date            Nov 24, 2016
      Polarize                        Vertical/Horizontal                 Test Engineer             Kevin Kuo
      Detector                        Peak and Average                    Test Voltage:               12Vde

      Spectrum                                                                                                     &
      RefLevel 119.50 dBu¥           Offset 11.50 db @ RBW    1 MHz
                                     SWT     240 ms @ VBW 3 MHz         Mode Auto Sweap
      ExtMix D
     @ 19k View
                                                                            Miji]                      69.71 dBpy
                                                                                                     115.5140 GHz
      110 dBp¥


      100 dBpV
                           D2 97.500 dBy

     20 dBpy

     so dgpy
                     D1 77.500 dap
                MJ

     WWMMMMMW                                        fAdmotinetomail          smyAraninonBsclt

     60 dBpy‘

     5o dBpy

     40 dBpy‘

     30 dBpy


     Start 110.0 GHz                                          691 pts                              Stop 170.0 CHz
                      J\                                                  Neasuring...   @              24112016
                                                                                                         onians     //

    Date:   24.NOV.2016        O5: 14 :23




Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                             me                                                     me
                                                         Page 26 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf              2 Compliance Certification Services Inc.
                                                                                               Report No.: T160920D22—RP




    Test Mode:                          TX—24GHz                         Temp/Hum                27(°C)/ 53%RH
     Test Item                      170GHz—220GHz                       Test Date                 Nov 24, 2016
      Polarize                     Vertical/Horizontal                Test Engineer                Kevin Kuo
     Detector                      Peak and Average                   Test Voltage:                  12Vde
      Spectrum                                                                                                       (€)
      RefLevel 122.50 dBu¥        Offset 11.50 dB @ RBW   1 MHz
                                  SWT    200 ms @ VBW 3 MHz         Mode Auto Sweep
      Exthiix G
     (@12k View
      120 dBpV                                                           mifi]                          75.02 dBuy
                                                                                                      173.9440 GHz
      110 dBuV


      100 dbpy
                       D2 97,500 dBy

     20 dBgpy

     80 dBpYry
                  D1 77.500 dap
                  wnbtanteied..
     70 dBpy

     60 dBpy

     5o dBpy

     40 dBpyr

     30 dBpy

     Start 170.0 GHz                                      691 pts                                   Stop 220.0 GHz

                   J                                                  Measuring...   @@                  24.112016
                                                                                                          oi.         %

    Date:   24.NOV.2016    06: 42: 40


Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                          me    m                                                     me
                                                          Page 27 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf               2 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D22—RP




    Test Mode:                          TX—24GHz                            Temp/Hum            27(°C)/ 53%RH
     Test Item                       220GHz—250GHz                           Test Date           Nov 24, 2016
      Polarize                      Vertical/Horizontal                   Test Engineer             Kevin Kuo
      Detector                      Peak and Average                      Test Voltage:               12Vde
      Spectrum                                                                                                      (@)
      RefLevel 151.50 dBu¥         Offset   11.50 dB @ RBW    1 MHz
                                   SwT       120 ms @ VBW 3 MHz         Mode Auto Sweep
      Exthix J
     (@ 19k View
                                                                            Miji]                      98.69 dBpy
                                                                                                     225.9260 GHz
      140 dBpy

      130 dBpy

      120 dBpy

      110 dapy

                             NML
      100 dBpy
                   o1 97.500 dap
     90 dapy

     so dgpy
                         D2 77.500 dBu

     70 dBpy

     60 dgpy

     Start 220.0 GHz                                          691 pts                              Stop 250.0 GHz

                    J\                                                    Measuring...                  24.1.2016
                                                                                                         uns         /

    Date:   24.NOV.2016      21:27:34


Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit
       3. Above 220G, noise floor is higher than EUT signal..




                                                             me                                                      me
                                                         Page 28 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.



Document Created: 2016-11-28 11:51:18
Document Modified: 2016-11-28 11:51:18

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC