Test Report_DXX

FCC ID: WHBAFUTR

Test Report

Download: PDF
FCCID_3214143

                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP




             FCC RADIO TEST REPORT
                  FCC 47 CFR PART 15 SUBPART C
 Test Standard                     FCC Part 15.249(a)
 FCC ID                            WHBAFUTR
 Trade name                        AUDI
 Product name                      UTR (Universal Traffic Recorder)
 Model No.                         UTR (Universal Traffic Recorder)
 Test Result                       Pass


The test Result was tested by Compliance Certification Services Inc. The test data, data
evaluation, test procedures, and equipment configurations shown in this report were
given in ANSI C63.10: 2013 and compliance standards.
The test results of this report relate only to the tested sample (EUT) identified in this
report.

The test Report of full or partial shall not copy. Without written approval of CCS. lnc.

The sample selected for test was production product and was provided by manufacturer.




Approved by:                                                     Reviewed by:




Sam Chuang                                                       Zeus Chen
Manager                                                          Supervisor




                                                         Page 1 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                             Report No.: T160920D21-RP




                                       Revision History
Rev.           Issue Date                                       Revisions                              Revised By
 00         November 24, 2016                                  Initial Issue                          Angel Cheng




                                                        Page 2 / 30                                                Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                    Compliance Certification Services Inc.
                                                                                                       Report No.: T160920D21-RP




                                           Table of contents
1. GENERAL INFORMATION .................................................................................................. 4

      1.1    EUT INFORMATION .................................................................................................. 4

      1.2    EUT CHANNEL INFORMATION ................................................................................ 5

      1.3    ANTENNA INFORMATION ........................................................................................ 5

      1.4    MEASUREMENT UNCERTAINTY.............................................................................. 6

      1.5    FACILITIES AND TEST LOCATION .......................................................................... 7

      1.6    INSTRUMENT CALIBRATION ................................................................................... 7

      1.7    SUPPORT AND EUT ACCESSORIES EQUIPMENT ................................................. 8

2. TEST SUMMERY ................................................................................................................. 9

3. DESCRIPTION OF TEST MODES ..................................................................................... 10

      3.1    THE WORST MODE OF OPERATING CONDITION ................................................ 10

      3.2    THE WORST MODE OF MEASUREMENT .............................................................. 10

4. TEST RESULT ................................................................................................................... 11

4.1 FIELD STRENGTH OF FUNDAMENTAL AND SPURIOUS EMISSION ............................ 11
APPENDIX 1 - PHOTOGRAPHS OF EUT




                                                          Page 3 / 30                                                Rev.00
   This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP



1. GENERAL INFORMATION
1.1 EUT INFORMATION
                                 Mobile Appliance, Inc.
                                 401, simin-daero, Dongan-gu, #1701-1706, Daerung Techno
Applicant
                                 Town 15, Gwanyang-dong, Anyang-si, Gyeonggi-do, 14057,
                                 South Korea
Equipment                        UTR (Universal Traffic Recorder)

Model Name                       UTR (Universal Traffic Recorder)

Model Discrepancy                N/A

EUT Functions                    24G Radar

Received Date                    September 20, 2016

Date of Test                     Nov. 22, 2016
                                 Peak : 121.96 dBuV/m
Output Power
                                 Average : 100.68 dBuV/m

                                      AC
                                      DC Type :
Power Operation                          Battery
                                         DC Power Supply : 12V
                                         External DC adapter

Remark:
All listed models are using an identical RF module with the only differences on number of
key buttons mounted for additional functions.
Due to similarity of RF product constructions of given model series, only dedicated
model as described in test report with the most complexity constructions was selected
for testing and record
.




                                                         Page 4 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                             Report No.: T160920D21-RP



1.2 EUT CHANNEL INFORMATION
Frequency Range                          24.00GHz-24.25GHz


Modulation Type                          CW


Number of channel                        1

1.3 ANTENNA INFORMATION
                                                                 Integral: antenna permanently attached
Antenna Category                                                 External dedicated antennas
                                                                 External Unique antenna connector

                                                                 PIFA
                                                                 PCB
Antenna Type                                                     Dipole
                                                                 Printed
                                                                 Coils

Antenna Gain                                                9.5 dBi




                                                        Page 5 / 30                                                Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP



1.4 MEASUREMENT UNCERTAINTY
                    PARAMETER                                      UNCERTAINTY
AC Powerline Conducted Emission                                         +/- 1.2575
Emission bandwidth, 20dB bandwidth                                      +/- 1.4003
RF output power, conducted                                              +/- 1.1372
Power density, conducted                                                +/- 1.4003
3M Semi Anechoic Chamber / 30M~200M                                     +/- 4.0138
3M Semi Anechoic Chamber / 200M~1000M                                   +/- 3.9483
3M Semi Anechoic Chamber / 1G~8G                                        +/- 2.5975
3M Semi Anechoic Chamber / 8G~18G                                       +/- 2.6112
3M Semi Anechoic Chamber / 18G~26G                                      +/- 2.7389
3M Semi Anechoic Chamber / 26G~40G                                      +/- 2.9683
3M Semi Anechoic Chamber / 40G~60G                                      +/- 1.8509
3M Semi Anechoic Chamber / 60G~75G                                      +/- 1.9869
3M Semi Anechoic Chamber / 75G~110G                                     +/- 2.9651
3M Semi Anechoic Chamber / 110G~170G                                    +/- 2.7807
3M Semi Anechoic Chamber / 170G~220G                                    +/- 3.6437
3M Semi Anechoic Chamber / 220G~325G                        +/- 4.2982
Remark:
1.This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2
2. ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the
emissions test results be included in the report.




                                                         Page 6 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                  Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP



1.5 FACILITIES AND TEST LOCATION
All measurement facilities used to collect the measurement data are located at
No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.)

               Test site                                     Test Engineer                        Remark
          AC Conduction Room                                      -                                 -
               Radiation                                      Kevin Kuo                             -
             RF Conducted                                         -                                 -
Remark: The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and
CISPR Publication 22.

1.6 INSTRUMENT CALIBRATION
                                            3M 966 Chamber Test Site

    Equipment               Manufacturer                    Model                       S/N                Cal Due

Spectrum Analyzer               Agilent                    E4446A                 US42510252              12/07/2016

     Loop Ant               COM-POWER                       AL-130                    121051              02/24/2017

   Bilog Antenna           Sunol Sciences                     JB3                    A030105              07/02/2017

   Pre-Amplifier                 EMEC                       EM330                     60609               06/07/2017

   Horn Antenna                   ETC                    MCTD 1209               DRH13M02003              09/01/2017

   Pre-Amplifier                MITEQ             AMF-6F-260400-40-8P                 985646              01/13/2017

   Horn Antenna                 EMCO                         3116                     26370               01/14/2017
  Harmonic Mixer            A-INFO /                                              J202020872 /
                                                    LB-19-20-A / FS-Z60                                   04/16/2017
 40GHz - 60GHz          ROHDE&SCHWARZ                                                100142
  Harmonic Mixer
                        ROHDE&SCHWARZ               FH-PP-75 / FS-Z75            10001 / 100162           04/21/2017
 50GHz - 75GHz
  Harmonic Mixer
                        ROHDE&SCHWARZ              FH-PP-110 / FS-Z110           10003 / 100096           04/23/2017
 75GHz - 110GHz
  Harmonic Mixer
                        ROHDE&SCHWARZ FH-PP-170 / SAM-170                         10003 / 20011           04/26/2017
110GHz - 170GHz
  Harmonic Mixer
                        ROHDE&SCHWARZ FH-PP-220 / SAM-220                         10003 / 20013           04/29/2017
140GHz - 220GHz
  Harmonic Mixer         Radiometer Physics
                                                   FH-PP-325 / SAM-325            10007 / 20048           05/04/2017
220GHz - 325GHz                Gmbn
  Antenna Tower                   CCS                      CC-A-1F                      N/A                  N.C.R

     Controller                   CCS                      CC-C-1F                      N/A                  N.C.R
    Turn Table                    CCS                      CC-T-1F                      N/A                  N.C.R
Remark: Each piece of equipment is scheduled for calibration once a year and harmonic mixer twice a
year.




                                                         Page 7 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP



1.7 SUPPORT AND EUT ACCESSORIES EQUIPMENT
                                          EUT Accessories Equipment
 No.            Equipment                 Brand            Model                Series No.                 FCC ID
                     N/A

                                                Support Equipment
 No.            Equipment                 Brand             Model               Series No.                 FCC ID
  1         DC Power Source            GWINSTEK           SPS-3610                  N/A                       N/A

1.8 Test methodology and applied standards
The test methodology, setups and results comply with all requirements in accordance
with ANSI C63.10:2013, FCC Part 15.249.
1.9 Table of accreditations and listings
 Country Agency Scope of Accreditation                                                           Logo

                           3M Semi Anechoic Chamber (FCC MRA: TW1039) to perform
 USA          FCC
                           FCC Part 15 measurements
                                                                                                 FCC MRA: TW1039

              Industry     3M Semi Anechoic Chamber (IC 2324G-1 / IC 2324G-2) to
 Canada                                                                                          IC 2324G-1
              Canada       perform
                                                                                                 IC 2324G-2



        .




                                                         Page 8 / 30                                                Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                             Report No.: T160920D21-RP



2. TEST SUMMERY
FCC Standard               Report
                                                                   Test Item                                Result
   Section                 Section
   15.203                    1.2                         Antenna Requirement                                  Pass
  15.249(a)                  4.1                     Filed strength of fundamental                            Pass
  15.249(a)                  4.1                     Radiation Spurious Emission                              Pass




                                                        Page 9 / 30                                                Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP



3. DESCRIPTION OF TEST MODES
3.1 THE WORST MODE OF OPERATING CONDITION

Operation mode                                              24 GHz




Test Channel Frequencies                                    24.04GHz



3.2 THE WORST MODE OF MEASUREMENT
                                 AC Power Line Conducted Emission
  Test Condition                  AC Power line conducted emission for line and neutral
     Voltage/Hz                                                     120V/60Hz
      Test Mode                     N/A
    Worst Mode                      Mode 1            Mode 2           Mode 3            Mode 4

                           Radiated Emission Measurement Above 1G
  Test Condition                   Band edge, Emission for Unwanted and Fundamental
     Voltage/Hz                                                     120V/60Hz
      Test Mode                     Mode 1:EUT power by DC Source.
    Worst Mode                      Mode 1       Mode 2     Mode 3       Mode 4
                                    Placed in fixed position.
                                    Placed in fixed position at X-Plane (E2-Plane)
  Worst Position
                                    Placed in fixed position at Y-Plane (E1-Plane)
                                    Placed in fixed position at Z-Plane (H-Plane)
   Worst Polarity                   Horizontal     Vertical

                            Radiated Emission Measurement Below 1G
  Test Condition                                      Radiated Emission Below 1G
     Voltage/Hz                                                     120V/60Hz
      Test Mode                     Mode 1:EUT power by DC Source.
    Worst Mode            Mode 1       Mode 2      Mode 3        Mode 4
Remark:
1. The worst mode was record in this test report.
2. EUT pre-scanned in three axis ,X,Y, Z and two polarity, Horizontal and Vertical for
radiated measurement. The worst case(X-Plane and Vertical) were recorded in this
report.

                                                         Page 10 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP



4. TEST RESULT
4.1 FIELD STRENGTH OF FUNDAMENTAL AND SPURIOUS
    EMISSION
4.1.1 Test Limit
According to §15.249(a)
(1) The field strength of emissions from intentional radiators operated within these
frequency bands shall comply with the following:
          Fundamental                            Field strength of                        Field strength of
           frequency                               fundamental                               harmonics
             (MHz)                               (millivolts/meter)                      (microvolts/meter)
         2400-2483.5                                      50                                       500
          5725-5875                                       50                                       500
         24000-24250                                     250                                      2500
* Field strength limits are specified at a distance of 3 meters

                                      Fundamental Limit Conversion
       Average                       Average              Average                                    Peak
       (mV/m)                       (dBuV/m)             (dBuV/m)                                  (dBuV/m)
        at 3M                         at 3M                at 1M                                     at 1M
         250                        107.9588              117.50                                    137.50
*(Limit=107.9588+20LOG(3/1)=117.50 dBuV/m)

                                        Harmonic Limit Conversion
       Average                       Average              Average                                    Peak
        (uV/m)                      (dBuV/m)             (dBuV/m)                                  (dBuV/m)
         at 3M                        at 3M                at 1M                                     at 1M
         2500                        67.9588               77.50                                     97.50
*(Limit=67.9588+20LOG(3/1)=77.50 dBuV/m)




                                                         Page 11 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                               Report No.: T160920D21—RP




(2) Emissions radiated outside of the specified frequency bands, except for harmonics,
shall be attenuated by at least 50 dB below the level of the fundamental or to the general
radiated emission limits in §15.209(follow the table}, whichever is the lesser attenuation
Below 30 MHz


     Frequency                     Reuswengn                           ‘hiky
                                                                {microamperes/m)
                                                                                                    "aeure"
                                                                                                       ({metres)
     9—490 kHz                 2,400/F (F in kHz)                2,400/F (F in kHz)                       300
   490—1,705 kHz              24,000/F (F in kHz)                24,000/F (F in kHz)                       30
   1.705—30 MHz                          30                                N/A                             30

30
                                                                    Field Strength
       Frequency                                  microvolts/m at 3 metres (watts, e.i.r.p.)
           (MHz)                                Transmitters                                   Receivers
           30—88                                 100 (3 nw)                                    100 (3 nw)
          88—216                                150 (6.8 nW)                                  150 (6.8 nW)
         216—960                                200 (12 nW)                                   200 (12 nW)
        Above 960                               500 (75 nW)                                   500 (75 nW)

4.1.2 Test Procedure
1. The EUT is placed on a turntable, Above 1 GHz is 1.5m, below 1 GHz and above 40G
is 0.8m above ground plane. The EUT Configured un accordance with ANSI C63.10, and
the EUT set in a continuous mode.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
emission level. And EUT is set 3m away from the receiving antenna, which is scanned
from 1m to 4m above the ground plane to find out the highest emissions. Measurement
are made polarized in both the vertical and the horizontal positions with antenna.
3. The SA setting following :
  (1) Below 1G : RBW = 100kHz, VBW z> 3 RBW, Sweep = Auto, Detector = Peak,
  (2) Above 1G :
      (2.1) For Peak measurement : RBW = 1MHz, VBW > 3 RBW.
      (2.2) For Average measurement : RBW = 1MHz, VBW =10Hz.




                                                        Page 127 30                                                Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


                Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21-RP


4.1.3 Test Setup
9kHz ~ 30MHz




                              3m
                                                                                       Loop antenna
       EUT

                                                                                    Spectrum /
                                                                                     Receiver


              Turntable                   1m
                            0.8m




   Reference ground plane

30MHz ~ 1GHz

                                                                                     Antenna
                                                                                      tower


                              3m                                                     Bi-log
                                                                                    antenna
       EUT
                                     4m
                                                                                   Spectrum
                                                                                   analyzer


              Turntable                   1m
                            0.8m




   Reference ground plane




                                                        Page 13 / 30                                               Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                             Report No.: T160920D21—RP



Above 1 GHz

                                                                            Antenna
                                                                .            tower




              > 3m          <€                                              Horn
  EUT _\                                   /
                                                           ud              antenna




                                                                            Spectrum
                                                                            analyzer

                        v
       Turntable
                                                                                                oo

                                                                                 Pre—amp -\Q % E
                                              I                     1        L                          1




Above 40 GHz



                                   Fundamental or
                                   Harmonic Mixer

          Input from Test                                               Spectrum
              Fixture                                                   Analyser




                                         Local
                                       Oscillator
                                        Source
                                                                        Data Store




                                                      ma                                                         ma
                                                        Page 14 / 30                                               Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                               Report No.: T160920D21—RP




4.1.4 Test Result
                        Peak            Average                    Peak                  Average
   Freq.
                        Value            Value                     Limit                   Limit                Result
   (GHz)
                       (dBuV/m)         (dBuV/m)             (dBuV/m)                    (dBuV/m)
   24.04                121.96           100.68                137.50                     117.50                  Pass

Test Data
{1) Filed strength of fundamental:
    Test Mode:                          TX—24GHz                        Temp/Hum                   27(°C)/ 53%RH
     Test Item                        Fundamental                       Test Date                   Nov 22, 2016
      Polarize                         Horizontal                     Test Engineer                  Kevin Kuo
     Detector                             Peak                        Test Voltage:                    12Vde
      Spectrum                                                                                                        ué?
       RefLevel 150.15 dBpV       Offset 23.15 dB @ RBW    1 MHz
    e Att                 30 d8 @ SWT     500 ms @ VBW 3 MHz         Mode Auto Sweep
     (@12k View
                                                                           Mmifi]                       121.96 dBuy
                                                                                                     24.0547400 GHz
      140 dBpV


      120 dbpy
                                                                                         h1
      120 dBpy

      110 dBpy


     douv—
     20 dBgpy

     80 dBpy


     70 dBpy


     60 dapy


     CF 24.049675 GHz                                    691 pts                                     Span 20.0 MHz

                                                                      Measuring...   @        D Wt       24&;:&%::;    %
                  ][

    Date:   24.NOV.2016    06:04:12




                                                        Page 157 30                                                     Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf            2 Compliance Certification Services Inc.
                                                                                             Report No.: T160920D21—RP




   Test Mode:                       TX—24GHz                       Temp/Hum                    27(‘C)/ 53%RH
    Test Item                       Fundamental                     Test Date                    Nov 22, 2016
     Polarize                         Vertical                    Test Engineer                    Kevin Kuo
    Detector                          Average                      Test Voltage:                     12Vde
     Spectrum                                                                                                      (€)
     RefLevel 150.15 dBpV   Offset 23.15 dB @ RBW 1 MHz
   e Att            30 d8 @ SWT      500 ms @ VBW 3 MHz          Mode Auto Sweep
    @12m View
                                                                    mifi]                            110.93 dBuy
                                                                                                  24.0547400 GHz
     140 dBpV


     130 dBuv


     120 dbpy
                                                                                      M1
     110 dBpy

     100 dBpy

    20 dgpy

    so dapy

    70 dBpy


    60 dBpy



    CF 24.049675 GHz                                                                              Span 20.0 MHz

                 J                                                 Measuring...                        24.012016
                                                                                                        sssmazno    %

   Date:   24.NOV.2016   06:04:39




                                                      me                                                            me
                                                        Page 16 / 30                                               Rev.00
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                            Report No.: T160920D21—RP




(2) Below 1G:
    Test Mode:                             TX—24GHz                                 Temp/Hum                 27(°C)/ 53%RH
     Test Item                            3O0MHz—1GHz                                Test Date                Nov 22, 2016
      Polarize                                Vertical                         Test Engineer                     Kevin Kuo
      Detector                          Peak and Qusi—peak                     Test Voltage:                       12Vde
     80.0       dBu¥/m
                                                                                                              Limit]             —
                                                                                                              Margin:            —




      4l]_|

                                                                                                                 5           6


                                                                                4
            1    2        3
                                                                                                                       IMJ




     0.0
       30.000        127.00    224.00      321.00          418.00   515.00     €12.00    709.00    806.00                    1000.00 MHz



                                    :           Correct                                     hes                  .
   Frequency                  Reading                                 Result              Limit             Margin
      (MH2)                   (dBuy)                (';aé’/‘:")      (dBuV/m)           (dBuV/m)             (dB)                 Remark
    46.4900                   43.13                 —19.06             24.07              40.00             —15.93                   peak

    71.7100                   44.49                 —20.81             23.68              40.00             16.32                    peak
    146.4000                  38.81                 15.97              22.84              43.50             —20.66                   peak
    600.3600                  34.25                  —7.75             26.50              46.00             —19.50                   peak

    900.0900                  34.94                  —3.19             31.75              46.00             —14.25                   peak

    935.9800                  36.17                  —2.62             33.55              46.00             1245                     peak




                                                                    Page 177 30                                                        Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                      Report No.: T160920D21—RP




   Test Mode:                            TX—24GHz                             Temp/Hum                 27(°C)/ 53%RH
    Test Item                           3O0MHz—1GHz                            Test Date                Nov 22, 2016
     Polarize                             Horizontal                      Test Engineer                   Kevin Kuo
     Detector                         Peak and Qusi—peak                  Test Voltage:                     12Vde
    80.0         dBu¥/m
                                                                                                        Limi:        —
                                                                                                        Margin:      —




     40




    U‘;’fl.flfll]      127.00   224.00      321.00       418.00   515.00     612.00   709.00    806.00               1000.00 MHz




  mus®                       ols                  ts            dil                o6lle              OE nevene
                                  i           Correct                                 Inai                 .



   120.2100                  31.54                —15.50          16.04             43.50             —27 46             peak

   177.4400                  43.19                —17.21          25.98             43.50             17.52              peak
   250.1900                  33.87                16.27           17.60             46.00             —28.40             peak

   419.9400                  28.19                —11.10          17.09             46.00             —28.91             peak

   640.1300                  26.49                —6.80           19.69             46.00             —26.31             peak
   878.7500                  26.51                —3.44           23.07             46.00             —22.93             peak




                                                               Page 18 7 30                                                 Revoo
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                                  Report No.: T160920D21—RP




(3) Above 1G:
    Test Mode:                              TX—24GHz                              Temp/Hum                         27(°C)/ 53%RH
     Test Item                             1GHz—18GHz                              Test Date                        Nov 22, 2016
      Polarize                                Vertical                       Test Engineer                             Kevin Kuo
      Detector                           Peak and Average                    Test Voltage:                               12Vde
    110.0   dBu¥/m
                                                                                                                    Limit]       —
                                                                                                                    Limit2:      —




      70




                                                                                                   3
                                                               2



                          1



    30.0
       1000.000 2700.00        4400.00     €100.00      7800.00    9500.00   17200.00   12900.00       14600.00               18000.00 MHz



                                   :            Correct                                    hes                         .
   Frequency                  Reading                                                    Limit                    Margin
      (MH2)                   (dBuy)             (';aé’/‘:")        (dBuV/m)            (dBuV/m)                   (dB)             Remark
    3247.000                  39.50               —0.02                                  97.50                    —58.02             peak

    7762.000                  35.79              14.03                                   97.50                    ~47.68             peak

   13860.000                  33.75              21.73                                   97.50                    ~42.02             peak




                                                                   Page 19 7 30                                                          Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                     Report No.: T160920D21—RP




   Test Mode:                        TX—24GHz                            Temp/Hum                    27(°C)/ 53%RH
    Test Item                       1GHz—18GHz                           Test Date                     Nov 22, 2016
     Polarize                         Horizontal                      Test Engineer                      Kevin Kuo
     Detector                     Peak and Average                     Test Voltage:                         12Vde
   110.0   dBu¥/m




    70




                    1


   30.0             T
     1000.000 2700.00   4400.00    6100.00      7800.00   9500.00    11200.00   12900.00   1460000           18000.00 MHz



                             :          Correct                                    m                     .
  Frequency             Reading                             Result               Limit           Margin
     (MH2z)             (dBuy)           Factor
                                         (dB/m)           (dBuV/m)              (dBuV/m)             (dB)         Remark
   2855.000             39.08                —0.96          38.12                97.50           —59.38             peak
   6999.000             35.89                12.00          47.89                97.50           —49.61             peak

  13990.000             34.66            22.19              56.85                97.50           ~40.65             peak




                                                          Page 20 7 30                                                      Revoo
 This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                               Report No.: T160920D21—RP




    Test Mode:                           TX—24GHz                             Temp/Hum                             27(°C)/ 53%RH
     Test Item                          18GHz—40GHz                            Test Date                            Nov 22, 2016
      Polarize                            Vertical                          Test Engineer                               Kevin Kuo
      Detector                       Peak and Average                       Test Voltage:                                 12Vde
    110.0   dBu¥/m
                                                                                                                     Limit]       —
                                                                                                                     Limit2:      —




                                                                                                               5




                                                               4
                                                   2
      70                                               3
                     1




    30.0
       18000.000—20200.00    22400.00   24600.00   26800.00   29000.00      31200.00    33400.00—   35600.00                   40000.00 MHz



                                 :           Correct                                       Inai                         .
   Frequency                Reading           Factor               Result                Limit                 Margin                Remark
      (MH2z)                (dBuV)            (dB/m)           (dBuV/m)                (dBuV/m)                    (dB)

    20292.000                33.76            30.88                64.64                 97.50                 —32.86                  peak
    26060.000                36.90            33.97                70.87                 97.50                 —26.63                  peak
    27116.000                35.12            34.67                69.179                97.50                 —27.71                  peak
    28680.500                35.81            36.55                72.36                 97.50                 —25.14                  peak
    36540.000                48.26            39.33                87.59                 97.50                     —9.91               peak



Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                              Page 217 30                                                                 Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                             Report No.: T160920D21—RP




    Test Mode:                           TX—24GHz                            Temp/Hum                         27(°C)/ 53%RH
     Test Item                          18GHz—40GHz                           Test Date                        Nov 22, 2016
      Polarize                          Horizontal                         Test Engineer                         Kevin Kuo
      Detector                       Peak and Average                      Test Voltage:                           12Vde
    110.0   dBu¥/m




                                                              4
      70




    30.0
       18000.000—20200.00    22400.00   24600.00   26800.00   29000.00     31200.00    33400.00   35600.00            40000.00 MHz


   Frequency                Reading          fi:::rticrt           Result                Limit                Margin         Remark
      (MH2)                 (dBuVv)           (dB/m)           (dBuV/m)               (dBuV/m)                (dB)

    20252.000                33.94            30.88               64.82                97.50                 —32.68           peak
    26188.000                37.18             34.11              71.29                97.50                 —26.21           peak
    27298.000                3441             35.18               69.59                97.50                 —27.91           peak
    28439.000                34.65            36.54               71.19                97.50                 —26.31           peak
    35620.000                43.96            42.02               85.98                97.50                 —11.52           peak



Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                              Page 227 30                                                        Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf              2 Compliance Certification Services Inc.
                                                                                              Report No.: T160920D21—RP




    Test Mode:                            TX—24GHz                         Temp/Hum             27(°C)/ 53%RH
     Test Item                          40GHz—60GHz                         Test Date            Nov 22, 2016
      Polarize                     Vertical/Horizontal                   Test Engineer              Kevin Kuo
      Detector                     Peak and Average                      Test Voltage:                12Vde
      Spectrum                                                                                                     (€)
      RefLevel 107.50 dBu¥        Offset   10.50 dB @ RBW    1 MHz
                                  SwT        80 ms @ VBW 3 MHz         Mode Auto Sweep
      Exthiix U
     (@12k View
                                                                           mifi]                        57.52 dBuy
      100 dbpy                                                                                         49.5660 GHz
                        D2 96.500 dBy

     20 dBpy

     0 dBpy
                  D1 76.500 dap

     70 dBpy

     60 dgpy                                                 MJ



     so dBpy

     40 dBpy

     30 dBpy

     20 dBpy

      10 depy
     Start 40.0 GHz                                          691 pts                                Stop 60.0 GHz

                   J\                                                    Measuring...                   24112016
                                                                                                          osores    /

    Date:   24.NOV.2016     05:07: 43


Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                            me                                                      me
                                                         Page 23 / 30                                               Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


EESf              2 Compliance Certification Services Inc.
                                                                                                   Report No.: T160920D21—RP




    Test Mode:                            TX—24GHz                               Temp/Hum           27(°C)/ 53%RH
     Test Item                          60GHz—75GHz                               Test Date          Nov 22, 2016
      Polarize                     Vertical/Horizontal                         Test Engineer           Kevin Kuo
      Detector                     Peak and Average                            Test Voltage:             12Vde
      Spectrum                                                                                                        (€)
      RefLevel 111.50 dBu¥        Offset   10.50 dB @ RBW          1 MHz
                                  SwT         60 ms @ VBW 3 MHz              Mode Auto Sweep
      Exthiix V
     (@12k View
                                                                                 mifi]                     62.11 dBuy
                                                                                                          71.0850 GHz
      100 dBpy
                        D2 97.500 dBy

     20 dapy

     80 dBpy
                  D1 77.500 dap

     70 dBpy


     |codonk—s                      bogl} s     by   dn   alipagtcatlag


     so dBpy

     40 dBp


     20 dapy

     20 dBpy

     Start 60.0 GHz                                                691 pts                              Stop 75.0 GHz

                   J\                                                          Measuring...   @K           24112016
                                                                                                             sussi      //

    Date:   24.NOV.2016     06:35:51


Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                                  me                                                    me
                                                                  Page 24 / 30                                          Rev.00
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                 Report No.: T160920D21—RP




    Test Mode:                         TX—24GHz                           Temp/Hum                 27(°C)/ 53%RH
     Test Item                       75GHz—110GHz                          Test Date                Nov 22, 2016
      Polarize                     Vertical/Horizontal                 Test Engineer                    Kevin Kuo
      Detector                     Peak and Average                    Test Voltage:                      12Vde
      Spectrum                                                                                                       ué?
      RefLevel 119.50 dBu¥        Offset   11.50 dB @ RBW   1 MHz
                                  SWT       140 ms @ VBW 3 MHz        Mode Auto Sweep
      Exthiix W
     @12k View
                                                                          M1if1]                            67.70 dBuy
                                                                                                          102.5800 GHz
      110 dBpy


      100 dBp¥
                       D2 97.500 dBy

     90 dBpy


     80 dBpy
                  D1 77.500 dap

     70 dBpy                                                                                Mu
                             MMWWWWW                                                                         fubthcarhee.
     60 dBpy


     so dBpy


     40 dBpV


     30 dBpy



     Start 75.0 GHz                                         691 pts                                     Stop 110.0 GHz

                   J                                                   Measuring...   AK         dyth       is         ;
    Date:   24.NOV.2016    05:05:01



Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                            Page 257 30                                                  Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                                                  Report No.: T160920D21—RP




    Test Mode:                                TX—24GHz                                Temp/Hum                      27(°C)/ 53%RH
     Test Item                          110GHz—170GHz                                  Test Date                        Nov 22, 2016
      Polarize                         Vertical/Horizontal                       Test Engineer                           Kevin Kuo
      Detector                         Peak and Average                           Test Voltage:                            12Vde
      Spectrum                                                                                                                          ué?
      RefLevel 122.50 dBu¥v          Offset   11.50 dB @ RBW       1 MHz
                                     SWT       240 ms @ VBW 3 MHz             Mode Auto Swaap
      Exthiix D
     (@12k View
      120 dBuV                                                                        M1i[1i]                               73.04 dBuy
                                                                                                                          154.5880 GHz
      110 dbpy

      100 dBp¥
                          D2 97.500 dBy

     90 dBpy


     #0 dapy
                  D1 77.500 dap


     90081         ibrnt—A—rif                4       i   i    i           M   i
                                     itirantriinpimantrontinookpenponsietslnminrodt             T       in   soauch—1             4




     60 dBpy


     5o dapy

     40 dBpV


     30 dBpy


     Start 110.0 GHz                                               691 pts                                              Stop 170.0 GHz
                                                                                 Measuring...       @          D w          24,112016
                   ][                                                                                                        ososie       /

    Date: 24.N0V.2016            05:03:18

Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                                  Page 20 7 30                                                            Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                               Report No.: T160920D21—RP




    Test Mode:                             TX—24GHz                        Temp/Hum              27(°C)/ 53%RH
     Test Item                      170GHz—220GHz                         Test Date               Nov 22, 2016
      Polarize                     Vertical/Horizontal                  Test Engineer              Kevin Kuo
     Detector                      Peak and Average                     Test Voltage:                12Vde
      Spectrum                                                                                                       ué?
      RefLevel 122.50 dBu¥v       Offset   11.50 dB @ RBW   1 MHz
                                  SwT       200 ms @ VBW 3 MHz        Mode Auto Swaap
      Exthiix G
     (@12k View
      120 dBuV                                                             mi[1i]                        75.59 dBuy
                                                                                                      189.4150 GHz

      110 dbpy

      100 dBp¥
                        D2 97.500 dBy

     90 dBpy


     #0 dapy                                    im
                  D1 77.500 dap
     [DVnipestustAastlhe                   M—»\WWM                           Busecprrasnteadithy,dnnse
     70 dBpy

     60 dBpy


     5o dapy

     40 dBpV


     30 dBpy


     Start 170.0 GHz                                        691 pts                                 Stop 220.0 GHz
                                                                        Measuring...   @     D w         24,112018
                   ][                                                                                     assasie      ./

    Date:   24.NOV.2016     06:43:27


Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit




                                                            Page 27 7 30                                               Revoo
  This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.


|ZIZ2JS Compliance Certification Services Inc.
                                                                                               Report No.: T160920D21—RP




    Test Mode:                        TX—24GHz                           Temp/Hum                27(°C)/ 53%RH
     Test Item                     220GHz—250GHz                          Test Date               Nov 22, 2016
      Polarize                     Vertical/Horizontal                Test Engineer                  Kevin Kuo
      Detector                     Peak and Average                   Test Voltage:                    12Vde
      Spectrum                                                                                                   ué?
      RefLevel 151.50 d8pV        Offset 11.50 dB @ RBW   1 MHz
                                  SWT    120 ms @ VBW 3 MHz         Mode Auto Sweep
      Exthiix J
     @12k View
                                                                         M1i[1]                         100.95 dBu¥y
                                                                                                      249.9350 GHz

      140 dBpy

      130 dBp¥


      120 dBpV


      110 dBuV
                                                                                                                     4

                  P05 97500 cBy                   Mobmue                              mumuey rinrontnets

     90 dBpy


     80 dBpy
                  D1 77.500 dap

     70 dBpy


     60 dBpy


     Start 220.0 GHz                                      691 pts                                   Stop 250.0 GHz
                   J                                                  Measuring...          Do           hsn
    Date:   24.NOV.2016   04:59:01


Remark:
     1. Measuring frequencies from 1 GHz to the 10th harmonic of highest
            fundamental frequency.
      2. For above 1GHz,the EUT peak value was under average limit, therefore the
         Average value compliance with the average limit
       3. Above 220G, noise floor is higher than EUT signal..