MPE

FCC ID: WEF-WXC

RF Exposure Info

Download: PDF
FCCID_987840

                Prediction of MPE limit at a given distance

Equation from page 18 of OET Bulletin 65, Edition 97-01
                       PG
                S=
                      4πR 2
where:          S = power density
                P = power input to the antenna
                G = power gain of the antenna in the direction of interest relative to an isotropic radiator
                R = distance to the center of radiation of the antenna



                     Maximum peak output power --Conducted                    13.71    dBm
                                                                             0.0235    (W)
                                          Antenna gain(typical):                5.00   (dBi)
                                        Maximum antenna gain:                   3.16   (numeric)
                                            Prediction distance:              20.00    (cm)
                                          Prediction frequency:             2405.00    (MHz)
                                         Limit from table below:                   1   (mW/cm^2)

                         Power density at prediction frequency:                0.015 (mW/cm^2)

                                                                   EUT complies

FCC/LSGAC Local Official’s Guide to RF
A LOCAL GOVERNMENT OFFICIAL'S GUIDE TO TRANSMITTING ANTENNA RF
EMISSION SAFETY: RULES, PROCEDURES, AND PRACTICAL GUIDANCE


(B)       Limits for General P                    /Uncontrolled Exposure

Frequency                 ectric Field             Magnetic Field Strength          Power Density            Averaging Time
Rang                 Strength (E)                 (H)                               (S)         ,            |E]. |HP orS
(MHz)                (Vim)                        (A‘m)                             (mW/em‘)                (minutes)
0.3—1                614                          1.63                                      "               30
1.34                 82477                        2. 197                                                    30
30—300                                            0.073                                                     30
300—1500                                          —                                 £1500                   30
1500—100,000         ——                           —                                 1O                      30
T= frequency in MHz                                          *Planc—wave equivalent powerdensity
NOTE 1: Occupational—contr d limits apply in situations in which persons are exposed as a consequence of their employment
provided thase persons are fully aware of the potential for exposure and can exercise control over their exposure, Limits for
eccupationalicontralled exposure also apply in situations when an individual is transient through a location where
eccupationalicontrolled limits apply providedhe or she is made aware of the potential for exposure.

NOTE 2: General population tincontrolled exposures apply in situations in which the  gencral public may be exposed, or in which
persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot
exercise control over their exposure







Document Created: 2008-08-19 07:48:00
Document Modified: 2008-08-19 07:48:00

© 2024 FCC.report