Users Manual

FCC ID: WDQ-DW10345

Users Manual

Download: PDF
FCCID_1160961

Thin Door/Window Contact                                          2GIG-DW10-345
                                                                                                                       Battery Installation & Replacement
                                                                                                                       Under normal conditions the battery can last up to 5 years. If a sensor battery is low, a low battery notification will be indicated on
Operating Instructions                                                                                                 the 2GIG Alarm Control Panel’s screen. When the 2GIG alarm system indicates that there is a sensor with a low battery, replace the
                                                                                                                       battery immediately. Use only the recommended replacement batteries (see Specifications).
                                                                                                                       To install or replace the battery, do the following:
The 2GIG-DW10-345 is a Thin Door/Window Contact that can be installed on doors,                                        1.     To remove the sensor cover, use your finger to press the tab on the end of the case. This will disengage the clip holding the
windows, and many other objects that open and close. The sensor transmits signals                                             cover to the base.
to the control panel when a magnet mounted near the sensor is moved away from                                          2.     Place a small flathead screwdriver in the slot between the metal clip (see Figure 3) and the battery and twist the screwdriver
or closer to the sensor. The sensor has an external input that accepts N/C dry                                                slightly while holding back one of the black plastic edges holding the battery.
contact devices. The sensor is also equipped with a cover tamper for additional                                        3.     Insert the replacement battery with the + sign facing out. (see Figure 3)
                                                                                                                       4.     Verify programming and RF communication with the panel. (see Testing).
security.
                                                                            Figure 1                                   WARNING! The polarity of the battery must be observed, as shown (see Figure 3). Improper handling of lithium
                                                                                                                       batteries may result in heat generation, explosion or fire, which may lead to personal injuries. Replace only with the
Installation & Mounting Guidelines                                                                                     same or equivalent type of battery as recommended by the manufacturer. (see Specifications)
Use the following guidelines for internal switch usage:                                                                Batteries must not be recharged, disassembled or disposed of in fire. Disposal of used batteries must be made in accor-
                                                                                                                       dance with the waste recovery and recycling regulations in your area.
1.   Mount the sensor on the door frame and the magnet on the door. If the sensor is used on
                                                                                                                       Keep away from small children. If batteries are swallowed, promptly see a doctor.
     double doors, mount the sensor on the least-used door and the magnet on the most-used
     door.                                                                                                             California Only: This Perchlorate warning applies only to Manganese Dioxide Lithium cells sold or distributed ONLY in California,
2.   If possible, locate sensors within 100 ft. (30 m) of the panel. While a transmitter may have a                    USA. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate.
     range of 500 ft. (150 m) or more out in the open, the environment at the installation site can
     have a significant effect on transmitter range. Sometimes a change in sensor orientation can                      Specifications
     help overcome adverse wireless conditions.
                                                                                                                       Wireless Signal Range                    500 ft., open air, with 2GIG Wireless Alarm Control Panel
3.   Make sure the alignment arrow on the magnet points to the alignment mark on the sensor                            Code Outputs                             Alarm; Alarm Restore; External Alarm; External Restore; Tamper; Tamper Restore;
     (see Figure 1).                                                                                                                                            Supervisory; Low Battery
4.   Place sensors at least 4.7 in. (12 cm) above the floor to avoid damaging them.                                    Transmitter Frequency                    345.000 MHz (crystal controlled)
5.   Avoid mounting sensors in areas where they will be exposed to moisture or where the sensor                        Transmitter Frequency Tolerance          ± 10 kHz
     operating temperature range of 32 to 120°F (0 to 49°C) will be exceeded.                                          Transmitter Bandwidth                    24 kHz
                                                                                                                       Modulation Type                          Amplitude Shift Keying—On/Off Keying (ASK-OOK)
6.   Use spacers (not included) to keep sensors and magnets away from metal or metallic surfaces
                                                                                                                       Unique ID Codes                          Over one (1) million different code combinations
     such as foil wallpaper.                                                                                           Supervisory Interval                     70 minutes
7.   Avoid mounting sensors in areas with a large quantity of metal or electrical wiring, such as a         Figure 2
                                                                                                                       Peak Field Strength                      Typical 36,000 uV/m at 3m
     furnace or utility room.                                                                                          External Input Sampling Current          20 uA
                                                                                                                       External Input                           Accepts N/C dry contact devices
To mount the sensor, do the following:
                                                                                                                       Reed Switch Magnetic Sensitivity         10 to 20 amp turns
1.   Place the base of the sensor in the desired location and secure with included screws (see Figure 2).              Reed Sensitivity                         0.625 in. (1.59 cm) minimum gap, 0.85 in. (2.16 cm) typical
2.   When mounting the magnet, line up the arrow on the magnet with the middle line on one side of the                 Magnet Type                              Rare earth
     sensor (see Figure 1). Mount the magnet no more than 0.4 in. (1 cm) away from the sensor. Be sure to              Magnet Dimensions (LxWxH)                1.3 x 0.435 x 0.312 in. (3.3 x 1.1 x 0.79 cm)
                                                                                                                       Sensor Dimensions (LxWxH)                2.59 x 1.03 x 0.49 in. (6.58 x 2.62 x 1.24 cm)
     secure the magnet with provided adhesive.
                                                                                                                       Weight (including battery & magnet)      1.1 oz. (31.2 g)
To use the external input:                                                                                             Housing Material                         ABS plastic
                                                                                                                       Color                                    White
1.   Repeat above instructions for mounting.
                                                                                                                       Operating Temperature                    32° to 120°F (0° to 49°C)
2.   Drill hole through access hold, if needed (see Figure 2).                                                         Relative Humidity                        5-95% Non-Condensing
3.   Plug two-pin connector into J1 (see Figure 3).                                                                    Battery (included, not installed)        Two (2) Panasonic CR2032, 3 VDC, 225 mAh or equivalent Lithium coin batteries
4.   Connect wire to N/C dry contact device.                                                                           Battery Life                             5 years
                                                                                                                       Regulatory Listing(s)                    ETL, FCC Part 15, Industry Canada
                                                                                                                       Warranty*                                Two (2) years
Programming                                                                                                            Included Accessories                     Two (2) Phillip’s flat-head screws, one (1) two-pin connector with a 12” flying 2-wire
The following steps describe general guidelines for programming (learning) the sensor                                                                           lead, adhesive strip
into panel memory. Refer to the specific panel’s installation instructions for complete
programming details.                                                                                                   FCC COMPLIANCE STATEMENT*
1.   To remove the sensor cover, use your finger to press the tab on the end of the                                    This device complies with FCC Rules and Regulations as Part 15 devices, as well as Industry Canada Rules and Regulations.
                                                                                                                       Operation is subject to the following two conditions:
     case. This will disengage the clip holding the cover to the base.
2.   Set the panel to sensor learning mode.                                                                            1. This device may not cause harmful interference.
                                                                                                                       2. This device must accept any interference received, including interference that may cause undesired operation.
3.   Press and release the tamper switch (SW1) on the sensor until the panel responds
     (see Figure 3).                                                                                                   FCC ID: WDQ-DW10345
                                                                                                                       Industry Canada ID: 7794A-DW10345
4.   Replace the base of the sensor.
                                                                                                                       Note: Changes or modifications to the device may void FCC compliance.
5.   Exit program mode.                                                                               Figure 3         *For more warranty and compliance information, visit our website (www.2gig.com).

Testing
Before mounting the sensor, verify that the sensor mounting location provides good RF communication to the
panel. To verify, do the following:
1.   Put the control panel into sensor test mode.
2.   Hold the magnet next to the alignment mark on the side of the sensor and then pull the magnet away from                                                                                                                        Technical Support:
     the sensor.                                                                                                                                                                                                                      1-866-670-1591
3.   Listen for siren or keypad beeps to determine appropriate response (refer to the control panel installation                                                                                                                       www.2gig.com
     instructions).                                                                                                                                                                                                                                 05/19/09
4.   Exit sensor test mode.                                                                                                                                                                                                                           ©2009