RF Exposure Info

FCC ID: WBV-BR100

RF Exposure Info

Download: PDF
FCCID_1572202

                           RF EXPOSURE REPORT

                             REPORT NO.: SA110914C02
                              MODEL NO.: BR100
                                  FCC ID: WBV-BR100
                               RECEIVED: Sep. 13, 2011
                                  TESTED: Oct. 07 ~ Oct. 13, 2011
                                  ISSUED: Oct. 14, 2011



                            APPLICANT: Aerohive Networks, Inc.

                              ADDRESS: 330 Gibraltar Drive, Sunnyvale, CA 94089



                          ISSUED BY: Bureau Veritas Consumer Products Services
                                     (H.K.) Ltd., Taoyuan Branch

                 LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist.,
                              New Taipei City, Taiwan ( R.O.C )

               TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei
                              Shan Hsiang, Taoyuan Hsien 333, Taiwan,
                              R.O.C.




 This test report consists of 5 pages in total. It may be duplicated completely for legal use
 with the approval of the applicant. It should not be reproduced, except in full, without the
 written approval of our laboratory. The client should not use it to claim product, certification,
 approval, or endorsement by any government agency. The test results in the report only
 apply to the tested sample.




Report No.: SA110914C02                         1                        Report Format Version 4.0.0


                                         TABLE OF CONTENTS
RELEASE CONTROL RECORD ............................................................................................. 3
1.   CERTIFICATION .......................................................................................................... 4
2.   RF EXPOSURE............................................................................................................ 5
2.1  LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)...................................... 5
2.2  MPE CALCULATION FORMULA ................................................................................. 5
2.3  CLASSIFICATION ........................................................................................................ 5
2.4  CALCULATION RESULT OF MAXIMUM CONDUCTED POWER............................... 5




Report No.: SA110914C02                                        2                                Report Format Version 4.0.0


                               RELEASE CONTROL RECORD

 ISSUE NO.                REASON FOR CHANGE                     DATE ISSUED
 Original release         NA                                    Oct. 14, 2011




Report No.: SA110914C02                       3         Report Format Version 4.0.0


1. CERTIFICATION

                PRODUCT: AP Router
                    MODEL: BR100
                    BRAND: Aerohive
              APPLICANT: Aerohive Networks, Inc.
                   TESTED: Oct. 07 ~ Oct. 13, 2011
          TEST SAMPLE: ENGINEERING SAMPLE
            STANDARDS: FCC Part 2 (Section 2.1091)
                                 FCC OET Bulletin 65, Supplement C (01-01)
                                 IEEE C95.1



 The above equipment (Model: BR100) has been tested by Bureau Veritas Consumer
 Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the
 requirement of the above standards. The test record, data evaluation & Equipment
 Under Test (EUT) configurations represented herein are true and accurate accounts of
 the measurements of the sample’s EMC characteristics under the conditions specified
 in this report.




   PREPARED BY            :                                    ,   DATE:      Oct. 14, 2011
                                  Andrea Hsia / Specialist


   APPROVED BY            :                                    ,   DATE:      Oct. 14, 2011
                              Gary Chang / Technical Manager




Report No.: SA110914C02                             4                      Report Format Version 4.0.0


2. RF EXPOSURE
2.1    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
   FREQUENCY              ELECTRIC FIELD MAGNETIC FIELD POWER DENSITY             AVERAGE TIME
   RANGE (MHz)            STRENGTH (V/m) STRENGTH (A/m)   (mW/cm2)                  (minutes)
                 LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
      300-1500                    …             …              F/1500                      30
   1500-100,000                   …             …               1.0                        30

F = Frequency in MHz


2.2    MPE CALCULATION FORMULA
Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


2.3    CLASSIFICATION

The antenna of this product, under normal use condition, is at least 20cm away from the
body of the user. So, this device is classified as Mobile Device.




2.4    CALCULATION RESULT OF MAXIMUM CONDUCTED POWER


 FREQUENCY                            ANTENNA                     POWER
                    MAX POWER                       DISTANCE                              LIMIT
    BAND                                GAIN                      DENSITY
                      (dBm)                            (cm)                             (mW/cm2)
    (MHz)                               (dBi)                    (mW/ cm2)
   2412-2462               24.2         4.27           20             0.140                 1.00




Report No.: SA110914C02                         5                       Report Format Version 4.0.0



Document Created: 2011-10-24 10:54:38
Document Modified: 2011-10-24 10:54:38

© 2024 FCC.report