Test Report

FCC ID: WAZX1T530SKE11A03

Test Report

Download: PDF
FCCID_993082

                                                                                                                             Test report No.              : 28IE0193-HO-03-A
                                                                                                                             Page                         : 12 of 14
                                                                                                                             Issued date                  : July 18, 2008
                                                                                                                             FCC ID                       : WAZX1T530SKE11A03


APPENDIX 2: Data of EMI test
                                                                   Radiated Emission
               _



                                                   DATA OF RADIATED EMISSION TEST
                                                                                     UL Japan, Inc. Head Office EMC Lab. No.2 Semi Anechoic Chamber
                                                                                                                                Date : 2008/06/03
                         Company              :   Mitsubishi Electric Corporation Himeji Works                        Report No.           :   28IE0193-HO-03
                         Kind of EUT          :   SMART KEYLESS SYSTEM (Receiver)                                     Power                :   DC 3.0V
                         Model No.            :   SKE11A-03                                                           Temp./Humi.          :   22 deg.C. / 68 %
                         Serial No.           :   20080512-R1                                                          Engineer            :   Akio Hayashi
                         Mode / Remarks : Continuous Receiving 315MHz mode, Worst(Hor: Z / Ver: Z)
                         LIMIT : FCC15.109(a) 3m, below 1GHz:QP, above 1GHz:AV
                                 Except for the data below : adequate margin data below the limits.                                                     Horizontal
                                                                                                                                                        Vertical
                             [dBuV/m]             << QP DATA >>                                                                                         Horizontal
                        80                                                                                                                              Vertical


                        70

                        60

                        50

                        40

                        30

                        20

                        10

                         0
                          30M                 50M            70M          100M                     200M              300M                  500M       700M        1G
                                                                                                                                                      Frequency[Hz]



                                                               Antenna     Loss&
                              Frequency     Reading                                   Level      Angle    Height                Limit      Margin
                                                       DET      Factor      Gain                                    Polar.                           Comment
                                [MHz]       [dBuV]              [dB/m]      [dB]     [dBuV/m]    [Deg]     [cm]                [dBuV/m]     [dB]
                                   30.000      22.0     QP         18.9      -22.0        18.9        0       300   Hori.           40.0      21.1
                                   30.001      23.2     QP         18.9      -22.0        20.1      162       100   Vert.           40.0      19.9
                                   49.253      22.0     QP         10.4      -21.7        10.7        0       300   Hori.           40.0      29.3
                                   49.253      22.1     QP         10.4      -21.7        10.8        0       100   Vert.           40.0      29.2
                                   50.000      22.1     QP         10.2      -21.7        10.6        0       300   Hori.           40.0      29.4
                                   50.000      22.1     QP         10.2      -21.7        10.6        0       100   Vert.           40.0      29.4
                                  315.220      24.2     QP         14.9      -19.1        20.0      212       100   Hori.           46.0      26.0
                                  315.220      22.6     QP         14.9      -19.1        18.4      272       100   Vert.           46.0      27.6
                                  630.440      24.7     QP         19.7      -18.6        25.8      142       100   Hori.           46.0      20.2
                                  630.440      23.9     QP         19.7      -18.6        25.0       97       130   Vert.           46.0      21.0
                                  945.660      20.4     QP         22.4      -16.4        26.4      293       100   Hori.           46.0      19.6
                                  945.660      20.4     QP         22.4      -16.4        26.4        0       100   Vert.           46.0      19.6




                         CHART:WITH FACTOR ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN
                         CALCULATION:RESULT = READING + ANT FACTOR + LOSS(CABLE+ATTEN.) - GAIN(AMP)




           *The test result is rounded off to one or two decimal places, so some differences might be observed.

UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                                                        Test report No.              : 28IE0193-HO-03-A
                                                                                                                        Page                         : 13 of 14
                                                                                                                        Issued date                  : July 18, 2008
                                                                                                                        FCC ID                       : WAZX1T530SKE11A03




                                                                   Radiated Emission
              _




                                                  DATA OF RADIATED EMISSION TEST
                                                                               UL Japan, Inc. Head Office EMC Lab. No.2 Semi Anechoic Chamber
                                                                                                                        Date : 2008/06/03
                        Company              :   Mitsubishi Electric Corporation Himeji Works                    Report No.        :   28IE0193-HO-03
                        Kind of EUT          :   SMART KEYLESS SYSTEM (Receiver)                                 Power             :   DC 3.0V
                        Model No.            :   SKE11A-03                                                       Temp./Humi.       :   22 deg.C. / 68 %
                        Serial No.           :   20080512-R1                                                     Engineer          :   Akio Hayashi
                        Mode / Remarks : Continuous Receiving 315MHz mode, Worst(Hor: Z / Ver: Z)
                        LIMIT : FCC15.109(a) 3m, below 1GHz:QP, above 1GHz:PK
                                FCC15.109(a) 3m, below 1GHz:QP, above 1GHz:AV                                                                 Horizontal
                                                                                                                                              Vertical
                            [dBuV/m]             << AV/PEAK DATA >>                                                                           Horizontal
                                                                                                                                              Vertical
                       90

                       80

                       70

                       60

                       50

                       40

                       30

                       20

                       10

                       0
                        1G                                                                                                                              2G
                                                                                                                                            Frequency[Hz]


                                                            Antenna    Loss&
                             Frequency     Reading                               Level     Angle    Height             Limit      Margin
                                                      DET    Factor     Gain                                 Polar.                        Comment
                               [MHz]       [dBuV]            [dB/m]     [dB]   [dBuV/m]    [Deg]    [cm]              [dBuV/m]    [dB]
                                1260.880      43.0    PK        24.8     -31.2      36.6        0      100   Hori.         73.9     37.3
                                1260.880      31.0    AV        24.8     -31.2      24.6        0      100   Hori.         53.9     29.3
                                1260.880      41.9    PK        24.8     -31.2      35.5        0      100   Vert.         73.9     38.4
                                1260.880      31.4    AV        24.8     -31.2      25.0        0      100   Vert.         53.9     28.9
                                1576.100      29.9    AV        25.2     -30.6      24.5        0      100   Hori.         53.9     29.4
                                1576.100      40.1    PK        25.2     -30.6      34.7        0      100   Hori.         73.9     39.2
                                1576.100      40.4    PK        25.2     -30.6      35.0        0      100   Vert.         73.9     38.9
                                1576.100      30.3    AV        25.2     -30.6      24.9        0      100   Vert.         53.9     29.0
                                1891.320      29.7    AV        25.7     -30.1      25.3        0      100   Hori.         53.9     28.6
                                1891.320      40.6    PK        25.7     -30.1      36.2        0      100   Hori.         73.9     37.8
                                1891.320      43.4    PK        25.7     -30.1      39.0        0      100   Vert.         73.9     34.9
                                1891.320      30.1    AV        25.7     -30.1      25.7        0      100   Vert.         53.9     28.2




                        CHART:WITH FACTOR   ANT TYPE: -30MHz:LOOP, 30-300MHz:BICONICAL, 300MHz-1000MHz:LOGPERIODIC, 1000MHz-:HORN
                        CALCULATION:RESULT = READING + ANT FACTOR + LOSS(CABLE+ATTEN.) - GAIN(AMP)




           *The test result is rounded off to one or two decimal places, so some differences might be observed.


UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                              Test report No.       : 28IE0193-HO-03-A
                                                                              Page                  : 14 of 14
                                                                              Issued date           : July 18, 2008
                                                                              FCC ID                : WAZX1T530SKE11A03




APPENDIX 3: Test instruments
 Control No.        Instrument             Manufacturer        Model No         Test Item          Calibration Date *
                                                                                                    Interval(month)
  MAEC-02      Anechoic Chamber      TDK                  Semi Anechoic       RE                2008/04/17 * 12
                                                          Chamber 3m
   MOS-02      Digital Humidity      N.T                  NT-1800             RE                -
               Indicator
  MJM-05       Measure               PROMART              SEN1955             RE                -
  MSTW-14      EMI measurement       TSJ                  TEPTO-DV            RE                -
               program
 MRENT-62      Spectrum Analyzer     Agilent              E4448A              RE                2007/11/27 * 12
  MTR-03       Test Receiver         Rohde & Schwarz      ESCI                RE                2008/04/02 * 12
  MBA-02       Biconical Antenna     Schwarzbeck          BBA9106             RE                2007/10/21 * 12
  MLA-02       Logperiodic Antenna   Schwarzbeck          USLP9143            RE                2007/10/21 * 12
  MCC-12       Coaxial Cable         Fujikura/Agilent     -                   RE                2008/02/15 * 12
  MAT-07       Attenuator(6dB)       Weinschel Corp       2                   RE                2007/11/13 * 12
  MPA-09       Pre Amplifier         Agilent              8447D               RE                2007/09/13 * 12
  MHA-06       Horn Antenna          Schwarzbeck          BBHA9120D           RE                2008/01/19 * 12
  MCC-47       Microwave Cable       Suhner               SUCOFLEX104         RE                2008/05/12 * 12
               1G-26.5GHz
   MPA-10      Pre Amplifier         Agilent              8449B               RE                2007/09/27 * 12


The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with traceable calibrations. Each calibration is traceable to the national or international
standards.
As for some calibrations performed after the tested dates, those test equipment have been controlled by means of an
unbroken chains of calibrations.

Test Item:
  RE: Radiated emission