03 FCC Test Report_DCD

FCC ID: WAZSKESAD01

Test Report

Download: PDF
FCCID_4295049

                                                                                         Test report No.    : 12717479H-A
                                                                                         Page               : 1 of 19
                                                                                         Issued date        : March 14, 2019
                                                                                         FCC ID             : WAZSKESAD01




                              RADIO TEST REPORT
                               Test Report No. : 12717479H-A
        Applicant                            :     Mitsubishi Electric Corporation Himeji works

        Type of Equipment                    :     Smart Keyless System Smart Unit

        Model No.                            :     SKESAD-01

        FCC ID                               :     WAZSKESAD01

        Test regulation                      :     FCC Part 15 Subpart C: 2018

        Test Result                          :     Complied (Refer to SECTION 3.2)
          1.    This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
          2.    The results in this report apply only to the sample tested.
          3.    This sample tested is in compliance with above regulation.
          4.    The test results in this report are traceable to the national or international standards.
          5.    This test report covers Radio technical requirements. It does not cover administrative issues such as
                Manual or non-Radio test related Requirements. (if applicable)
          6.    The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
          7.    This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
          8.    The information provided from the customer for this report is identified in SECTION 1.

                         Date of test:                       February 6 and 17, 2019

                         Representative test
                         engineer:
                                                               Akihiko Maeda
                                                                  Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                               Motoya Imura
                                                                   Leader
                                                         Consumer Technology Division

                                                          This laboratory is accredited by the NVLAP LAB CODE
                                                          200572-0, U.S.A. The tests reported herein have been
                                                          performed in accordance with its terms of accreditation.
                                                          *As for the range of Accreditation in NVLAP, you may
                                                          refer to the WEB address,
                                                          http://japan.ul.com/resources/emc_accredited/

      NVLAP LAB CODE: 200572-0

   The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
   There is no testing item of "Non-accreditation".



UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124                                             Report Cover Page - 13-EM-F0429 Issue # 14.0


                                                                       Test report No.   : 12717479H-A
                                                                       Page              : 2 of 19
                                                                       Issued date       : March 14, 2019
                                                                       FCC ID            : WAZSKESAD01




                                   REVISION HISTORY
                               Original Test Report No.: 12717479H-A

Revision     Test report No.        Date              Page      Contents
                                                      revised
-            12717479H-A            March 14, 2019    -         -
(Original)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                        Test report No.        : 12717479H-A
                                                                                                        Page                   : 3 of 19
                                                                                                        Issued date            : March 14, 2019
                                                                                                        FCC ID                 : WAZSKESAD01


CONTENTS                                                                                                                                  PAGE

SECTION 1: Customer information ..................................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ........................................................................................ 4
SECTION 3: Test specification, procedures & results ........................................................................ 5
SECTION 4: Operation of E.U.T. during testing ................................................................................. 8
SECTION 5: Radiated emission (Fundamental and Spurious Emission) .......................................... 9
SECTION 6: -26dB Bandwidth ............................................................................................................ 12
SECTION 7: 99% Occupied Bandwidth ............................................................................................. 12
APPENDIX 1: Test data ....................................................................................................................... 13
  Radiated Emission below 30 MHz (Fundamental and Spurious Emission) ................................ 13
  Radiated Emission above 30 MHz (Spurious Emission) ................................................................ 15
  -26 dB Bandwidth and 99 % Occupied Bandwidth ....................................................................... 16
APPENDIX 2: Test instruments .......................................................................................................... 17
APPENDIX 3: Photographs of test setup ............................................................................................ 18
  Radiated Emission ............................................................................................................................. 18
  Worst Case Position (EUT: Z-axis) ................................................................................................. 19




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                  Test report No.   : 12717479H-A
                                                                                  Page              : 4 of 19
                                                                                  Issued date       : March 14, 2019
                                                                                  FCC ID            : WAZSKESAD01



SECTION 1: Customer information
Company Name                            :     Mitsubishi Electric Corporation Himeji works
Address                                 :     840 Chiyoda-machi, Himeji, Hyogo 670-8677, Japan
Telephone Number                        :     +81-79-298-9580
Facsimile Number                        :     +81-79-298-9929
Contact Person                          :     Shinichi Furuta

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the above information in SECTION 2 and 4.



SECTION 2: Equipment under test (E.U.T.)
2.1      Identification of E.U.T.

Type of Equipment                       :     Smart Keyless System Smart Unit
Model No.                               :     SKESAD-01
Serial No.                              :     Refer to Section 4, Clause 4.2
Rating                                  :     DC 12.0 V
Receipt Date of Sample                  :     February 4, 2019
(Information from test lab.)
Country of Mass-production              :     Japan
Condition of EUT                        :     Engineering prototype
                                              (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                     :     No Modification by the test lab


2.2      Product Description

Model No: SKESAD-01, (referred to as the EUT in this report), is the Smart Keyless System Smart Unit.

Radio Specification

LF Part
Equipment Type                      :         Transmitter
Type of modulation                  :         ASK
Frequency of operation              :         125 kHz
Other clock frequency               :         -
Antenna Type                        :         Inductive
Clock frequency                     :         8 MHz

RF Part *
Type of Receiver                    :         Receiver
Frequency of operation              :         315 MHz
Other clock frequency               :         30.32 MHz
Intermediate frequency              :         280 kHz
Antenna Type                        :         Bar Antenna

* The test of receiver part was performed separately from this test report, and the conformability is confirmed.
RF Part test report No. 12717479H-B (FCC15B).


UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                            Test report No.      : 12717479H-A
                                                                                            Page                 : 5 of 19
                                                                                            Issued date          : March 14, 2019
                                                                                            FCC ID               : WAZSKESAD01



 SECTION 3: Test specification, procedures & results

 3.1     Test Specification

 Test Specification             :       FCC Part 15 Subpart C
                                        FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

 Title                          :       FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                        Section 15.207 Conducted limits
                                        Section 15.209 Radiated emission limits; general requirements.

 * Also the EUT complies with FCC Part 15 Subpart B.


 3.2       Procedures and results

Item                        Test Procedure            Specification      Remarks       Deviation Worst margin                Results
                            <FCC>
                                                      <FCC>
                            ANSI C63.10:2013
                                                      Section 15.207
Conducted Emission          6 Standard test methods                      -             N/A           N/A *1)                 N/A
                                                      <IC>
                            <IC>
                                                      RSS-Gen 8.8
                            RSS-Gen 8.8
                            <FCC>                     <FCC>
                                                                                                     6.3 dB
                            ANSI C63.10:2013          Section 15.209
Electric Field Strength of                                                                           125 kHz                 Complied
                            6 Standard test methods <IC>                 Radiated      N/A
Fundamental Emission                                                                                 0 deg.                  a)
                            <IC>                      RSS-210 4.4
                                                                                                     PK with Duty Factor
                            RSS-Gen 6.5, 6.12         RSS-Gen 8.9
                            <FCC>                     <FCC>
                            ANSI C63.10:2013          Section 15.209                                 22.5 dB
Electric Field Strength of                                                                                                   Complied
                            6 Standard test methods <IC>                 Radiated      N/A           625 kHz, 0 deg.
Spurious Emission                                                                                                            a)
                            <IC>                      RSS-210 4.4                                    QP
                            RSS-Gen 6.5, 6.6, 6.13 RSS-Gen 8.9
                            <FCC>
                                                      <FCC>
                            ANSI C63.10:2013
                                                      Reference data                                                         Complied
-26dB Bandwidth             6 Standard test methods                      Radiated      N/A           N/A
                                                      <IC>                                                                   b)
                            <IC>
                                                      -
                            -
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT is not the device that is designed to be connected to the public utility (AC) power line.

a) Refer to APPENDIX 1 (data of Radiated emission)
b) Refer to APPENDIX 1 (data of -26 dB Bandwidth and 99 % Occupied Bandwidth)
Symbols:
 Complied        The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#       The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

 FCC 15.31 (e)
 The EUT provides stable voltage constantly to the wireless transmitter regardless of input voltage.
 Instead of a new battery, DC power supply was used for the test.
 That does not affect the test result, therefore the EUT complies with the requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone        : +81 596 24 8999
 Facsimile        : +81 596 24 8124


                                                                                          Test report No.     : 12717479H-A
                                                                                          Page                : 6 of 19
                                                                                          Issued date         : March 14, 2019
                                                                                          FCC ID              : WAZSKESAD01


3.3       Addition to standard

Item                            Test Procedure        Specification    Remarks       Deviation Worst margin        Results
99 % Occupied Band Width        RSS-Gen 6.7           -                Radiated      N/A       N/A                 -

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
Other than above, no addition, exclusion nor deviation has been made from the standard.


3.4       Uncertainty

There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived depending on whether or not
laboratory uncertainty is applied.

The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.


                                      Radiated emission
          Test distance                     (+/-)

                                       9 kHz to 30 MHz
  3m                                       3.3 dB
  10 m                                     3.2 dB
*Measurement distance

                                             Radiated emission (Below 1 GHz)
       Polarity                  (3 m*)(+/-)                                 (10 m*)(+/-)
                  30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
    Horizontal         4.8 dB                5.2 dB                  4.8 dB               5.0 dB
     Vertical          5.0 dB                6.3 dB                  4.9 dB               5.0 dB
* Measurement distance

      Bandwidth
      0.96 %




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                       Test report No.     : 12717479H-A
                                                                                       Page                : 7 of 19
                                                                                       Issued date         : March 14, 2019
                                                                                       FCC ID              : WAZSKESAD01


3.5         Test Location

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                   Maximum
                      IC Registration Width x Depth x     Size of reference ground plane (m)
Test site                                                                                    Other rooms           measuremen
                      Number          Height (m)          / horizontal conducting plane
                                                                                                                   t distance
No.1 semi-anechoic                                                                              No.1 Power
                       2973C-1         19.2 x 11.2 x 7.7   7.0 x 6.0                                               10 m
chamber                                                                                         source room
No.2 semi-anechoic
                       2973C-2         7.5 x 5.8 x 5.2     4.0 x 4.0                            -                  3m
chamber
No.3 semi-anechoic                                                                              No.3 Preparation
                       2973C-3         12.0 x 8.5 x 5.9    6.8 x 5.75                                              3m
chamber                                                                                         room
No.3 shielded room -                   4.0 x 6.0 x 2.7     N/A                                  -                  -
No.4 semi-anechoic                                                                              No.4 Preparation
                       2973C-4         12.0 x 8.5 x 5.9    6.8 x 5.75                                              3m
chamber                                                                                         room
No.4 shielded room -                   4.0 x 6.0 x 2.7     N/A                                  -                  -
No.5 semi-anechoic
                       -               6.0 x 6.0 x 3.9     6.0 x 6.0                            -                  -
chamber
No.6 shielded room -                   4.0 x 4.5 x 2.7     4.0 x 4.5                            -                  -
No.6 measurement
                       -               4.75 x 5.4 x 3.0    4.75 x 4.15                          -                  -
room
No.7 shielded room -                   4.7 x 7.5 x 2.7     4.7 x 7.5                            -                  -
No.8 measurement
                       -               3.1 x 5.0 x 2.7     3.1 x 5.0                            -                  -
room
No.9 measurement
                       -               8.8 x 4.6 x 2.8     2.4 x 2.4                            -                  -
room
No.11 measurement
                       -               6.2 x 4.7 x 3.0     4.8 x 4.6                            -                  -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0m for No.1, No.2, No.3, and No.4
semi-anechoic chambers and No.3 and No.4 shielded rooms.



3.6    Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                     Test report No.   : 12717479H-A
                                                                                     Page              : 8 of 19
                                                                                     Issued date       : March 14, 2019
                                                                                     FCC ID            : WAZSKESAD01



SECTION 4: Operation of E.U.T. during testing
4.1      Operating Modes

Test mode                                                                                Remarks
1) Tx 125 kHz Mod on                                                                     -

Justification     : The system was configured in typical fashion (as a user would normally use it) for testing.


4.2 Configuration and peripherals




                                                               A




                                                      1            2


                                                           B




                                                           DC 12.0 V



          * Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT and Support equipment
 No. Item                    Model number                 Serial number     Manufacturer                    Remarks
 A     Smart Keyless System SKESAD-01                     20190131-E1       Mitsubishi Electric             EUT
       Smart Unit                                         (No.1)            Corporation Himeji works
 B     SW BOX                SW BOX2                      No.16             Mitsubishi Electric             -
                                                                            Corporation Himeji works

List of cables used
 No. Name                         Length (m)                                Shield                        Remarks
                                                                 Cable               Connector
 1      DC and Signal Cable       1.0                          Unshielded            Unshielded        -
 2      DC Cable                  1.5                          Unshielded            Unshielded        (No.1)




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                  Test report No.   : 12717479H-A
                                                                                  Page              : 9 of 19
                                                                                  Issued date       : March 14, 2019
                                                                                  FCC ID            : WAZSKESAD01



SECTION 5: Radiated emission (Fundamental and Spurious Emission)
Test Procedure

EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

  Frequency : From 9 kHz to 30 MHz
    The EUT was rotated a full revolution in order to obtain the maximum value of the electric field intensity.
    The measurements were performed for vertical polarization (antenna angle: 0 deg., 45 deg., 90 deg., and 135 deg.)
    and horizontal polarization.
    *Refer to Figure 1 about Direction of the Loop Antenna.

  Frequency: From 30 MHz to 1 GHz
    The measuring antenna height varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain
    the maximum value of the electric field intensity.
    The measurements were performed for both vertical and horizontal antenna polarization.

The test was made with the detector (RBW / VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

Test Antennas are used as below;
Frequency             Below 30 MHz                          30 MHz to 200 MHz           200 MHz to 1 GHz
Antenna Type          Loop                                  Biconical                   Logperiodic

Frequency             From 9 kHz to        From 90 kHz to      From 150 kHz to   From 490 kHz to    From 30 MHz to
                         90 kHz               110 kHz             490 kHz           30 MHz              1 GHz
                           and
                     From 110 kHz to
                         150 kHz
Instrument used                                                 Test Receiver
Detector                  PK / AV                  QP            PK / AV               QP                 QP
IF Bandwidth               200 Hz                200 Hz            9 kHz              9 kHz             120 kHz
Test Distance              3 m *1)              3 m *1)           3 m *1)            3 m *2)              3m
*1) Distance Factor: 40 x log (3 m / 300 m) = -80 dB
*2) Distance Factor: 40 x log (3 m / 30 m) = -40 dB

Although these tests were performed other than open field test site, adequate comparison measurements were confirmed
against 30 m open field test site. Therefore sufficient tests were made to demonstrate that the alternative site produces
results that correlate with the ones of tests made in an open field based on KDB 414788.

These tests were performed in semi anechoic chamber. Therefore the measured level of emissions may be higher than if
measurements were made without a ground plane.
However test results were confirmed to pass against standard limit.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                 Test report No.   : 12717479H-A
                                                                                 Page              : 10 of 19
                                                                                 Issued date       : March 14, 2019
                                                                                 FCC ID            : WAZSKESAD01


[Test Setup]
 Below 1 GHz
                                                               Test Distance: 3 m / 10 m




                  3 m / 10 m




- The carrier level and noise levels were confirmed at each position of X, Y and Z axes of EUT to see the position of
maximum noise, and the test was made at the position that has the maximum noise.


The test results and limit are rounded off to one decimal place, so some differences might be observed.

Measurement range                   : 9 kHz - 1 GHz
Test data                           : APPENDIX 1
Test result                         : Pass

Date:          February 6, 2019              Test engineer:           Yuta Moriya
               February 17, 2019                                      Akihiko Maeda




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                        Test report No.   : 12717479H-A
                                                                        Page              : 11 of 19
                                                                        Issued date       : March 14, 2019
                                                                        FCC ID            : WAZSKESAD01


Figure 1: Direction of the Loop Antenna


  Side View (Vertical)


        EUT




  Top View (Horizontal)




        EUT




                                           Antenna was not rotated.


 Top View (Vertical)


                                            135deg

       EUT                                 90deg

                                             45deg
                                                      0deg


                                         Front side: 0 deg.
                                         Forward direction: clockwise




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                               Test report No.    : 12717479H-A
                                                                                               Page               : 12 of 19
                                                                                               Issued date        : March 14, 2019
                                                                                               FCC ID             : WAZSKESAD01



SECTION 6: -26dB Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test                      Span              RBW            VBW           Sweep              Detector      Trace        Instrument used
-26 dB Bandwidth          50 kHz            510 Hz         1.6 kHz       Auto               Peak          Max Hold     Spectrum Analyzer

Test data                                 : APPENDIX 1
Test result                               : Pass



SECTION 7: 99% Occupied Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test               Span                     RBW            VBW           Sweep              Detector      Trace        Instrument used
99 % Occupied     Enough width to display 1 to 5 %        Three times Auto                   Peak *1)     Max Hold     Spectrum Analyzer
Bandwidth         emission skirts           of OBW        of RBW                                          *1)
*1) The measurement was performed with Peak detector, Max Hold since the duty cycle was not 100 %.
Peak hold was applied as Worst-case measurement.


Test data                                 : APPENDIX 1
Test result                               : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                             Test report No.       : 12717479H-A
                                                                                                             Page                  : 13 of 19
                                                                                                             Issued date           : March 14, 2019
                                                                                                             FCC ID                : WAZSKESAD01


APPENDIX 1: Test data

                 Radiated Emission below 30 MHz (Fundamental and Spurious Emission)

                  Report No.                          12717479H
                  Test place                          Ise EMC Lab.
                  Semi Anechoic Chamber               No.1
                  Date                                February 6, 2019
                  Temperature / Humidity              22 deg. C / 42% RH
                  Engineer                            Yuta Moriya
                  Mode                                Tx 125kHz Mod on

PK or QP
   Ant Deg [deg]      Frequency Detector Reading        Ant        Loss     Gain       Duty         Result      Limit          Margin             Remark
          or           消すな                            Factor                          Factor
 Polarity [Hori/Vert]   [MHz]               [dBuV] [dB/m]          [dB]     [dB]       [dB]        [dBuV/m] [dBuV/m]            [dB]
                   0     0.12500 PK           105.9      19.7       -74.0     32.3            -          19.3   45.6                    26.3 Fundamental
                   0     0.25000 PK            68.0      19.7       -74.0     32.3            -         -18.6   39.6                    58.2
                   0     0.37500 PK            65.5      19.6       -73.9     32.3            -         -21.1   36.1                    57.2
                   0     0.50000 QP            36.1      19.6       -33.9     32.2            -         -10.4   33.6                    44.0
                   0     0.62500 QP            55.7      19.6       -33.9     32.2            -           9.2   31.7                    22.5
                   0     0.75000 QP            32.6      19.6       -33.9     32.2            -         -13.9   30.1                    44.0
                   0     0.87500 QP            49.4      19.6       -33.8     32.2            -           3.0   28.7                    25.7
                   0     1.00000 QP            31.6      19.6       -33.8     32.2            -         -14.8   27.6                    42.4
                   0     1.12500 QP            45.2      19.6       -33.8     32.2            -          -1.2   26.5                    27.7
                   0     1.25000 QP            30.9      19.6       -33.8     32.2            -         -15.5   25.6                    41.1
Result = Reading + Ant Factor + Loss (Cable + Attenuator + Filter + D.Factor) - Gain(Amprifier)

PK with Duty factor
   Ant Deg [deg]     Frequency Detector Reading          Ant        Loss     Gain         Duty        Result     Limit  Margin      Remark
      Ant Deg          消すな                             Factor                            Factor
      Ant Deg          [MHz]                [dBuV] [dB/m]           [dB]      [dB]        [dB]      [dBuV/m] [dBuV/m]    [dB]
                  0     0.12500 PK            105.9       19.7       -74.0      32.3          0.0           19.3   25.6         6.3
                  0     0.25000 PK             68.0       19.7       -74.0      32.3          0.0          -18.6   19.6        38.2
                  0     0.37500 PK             65.5       19.6       -73.9      32.3          0.0          -21.1   16.1        37.2
Result = Reading + Ant Factor + Loss (Cable + Attenuator + Filter + D.Factor) - Gain(Amprifier) + Duty factor *
                    * Since the peak emission result satisfied the average limit, duty factor was omitted. (PKのリザルトが、AVのLimitを満足する為、Duty factor測定




      Result of the fundamental emission at 3m without Distance factor
PK or QP
 Ant Deg [deg]     Frequency Detector Reading       Ant       Loss     Gain      Duty              Result      Limit           Margin             Remark
                    消すな                           Factor                         Factor
                     [MHz]               [dBuV] [dB/m]        [dB]     [dB]       [dB]            [dBuV/m] [dBuV/m]             [dB]
               0      0.12500 PK           105.9     19.7         6.0    32.3           -               99.3      -                        - Fundamental
Result = Reading + Ant Factor + Loss (Cable+Attenuator+Filter) - Gain(Amprifier)
     消すな


      * All spurious emissions lower than this result.


             *The test result is rounded off to one or two decimal places, so some differences might be observed.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                             Test report No.           : 12717479H-A
                                                                                             Page                      : 14 of 19
                                                                                             Issued date               : March 14, 2019
                                                                                             FCC ID                    : WAZSKESAD01


             Radiated Emission below 30 MHz (Fundamental and Spurious Emission)
                                    (Plot data, Worst case)

             Report No.                           12717479H
             Test place                           Ise EMC Lab.
             Semi Anechoic Chamber                No.1
             Date                                 February 6, 2019
             Temperature / Humidity               22 deg. C / 42% RH
             Engineer                             Yuta Moriya
             Mode                                 Tx 125kHz Mod on

                     [dBuV/m]         << QP/PEAK DATA >>                                                    0 deg      :A
               100
                90
                80
                70
                60
                50
                40
                30
                20
                10
                 0
               -10
               -20
               -30
               -40
               -50
               -60
               -70
                     .01M       .02M .03M   .05M .07M .1M   .2M   .3M   .5M .7M   1M   2M   3M    5M   7M   10M         20M 30M
                                                                                                                    Frequency[Hz]



           *These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                                                      Test report No.              : 12717479H-A
                                                                                                                      Page                         : 15 of 19
                                                                                                                      Issued date                  : March 14, 2019
                                                                                                                      FCC ID                       : WAZSKESAD01


                              Radiated Emission above 30 MHz (Spurious Emission)

             Report No.                                   12717479H
             Test place                                   Ise EMC Lab.
             Semi Anechoic Chamber                        No.1
             Date                                         February 17, 2019
             Temperature / Humidity                       20 deg. C / 51 % RH
             Engineer                                     Akihiko Maeda
                                                          (Below 1 GHz)
             Mode                                         Mode 1

                 LIMIT : FCC15.209 3m, below 1GHz:QP, above 1GHz:PK
                         All other spurious emissions were less than 20dB for the limit.                                                     Horizontal
                                                                                                                                             Vertical
                                                                                                                                             Horizontal
                     [dBuV/m]           << QP DATA >>                                                                                        Vertical
                80

                70

                60

                50

                40

                30

                20

                10

                 0
                  30M                 50M           70M          100M                     200M             300M                500M       700M        1G
                                                                                                                                          Frequency[Hz]



                                                      Antenna     Loss&
                      Frequency     Reading                                  Level      Angle    Height             Limit      Margin
                                              DET      Factor      Gain                                   Polar.                         Comment
                        [MHz]       [dBuV]             [dB/m]      [dB]     [dBuV/m]    [Deg]    [cm]              [dBuV/m]     [dB]
                           41.333      22.4   QP          14.2      -24.8        11.8      334      150   Hori.         40.0      28.2
                           41.333      24.4   QP          14.2      -24.8        13.8      234      232   Vert.         40.0      26.2
                           58.160      22.0   QP           8.3      -24.5         5.8      148      179   Hori.         40.0      34.2
                           58.160      22.1   QP           8.3      -24.5         5.9        1      118   Vert.         40.0      34.1
                           80.000      24.4   QP           6.9      -24.1         7.2      287      233   Hori.         40.0      32.8
                           80.000      29.6   QP           6.9      -24.1        12.4        0      205   Vert.         40.0      27.6
                          144.184      21.8   QP          14.7      -23.3        13.2      359      150   Hori.         43.5      30.3
                          144.184      21.7   QP          14.7      -23.3        13.1      226      150   Vert.         43.5      30.4
                          309.334      21.4   QP          13.9      -21.9        13.4      305      150   Hori.         46.0      32.6
                          309.334      21.4   QP          13.9      -21.9        13.4      215      100   Vert.         46.0      32.6
                          608.124      21.5   QP          19.5      -20.3        20.7      359      123   Hori.         46.0      25.3
                          608.124      21.6   QP          19.5      -20.3        20.8        0      100   Vert.         46.0      25.2




  CHART: WITH FACTOR
  ANT TYPE: - 30 MHz: LOOP, 30 MHz - 200 MHz: BICONICAL, 200 MHz - 1000 MHz: LOGPERIODIC, 1000 MHz -: HORN
  CALCULATION: RESULT = READING + ANT FACTOR + LOSS & GAIN (CABLE + ATT - GAIN(AMP))

          *The test result is rounded off to one or two decimal places, so some differences might be observed.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                       Test report No.   : 12717479H-A
                                                                       Page              : 16 of 19
                                                                       Issued date       : March 14, 2019
                                                                       FCC ID            : WAZSKESAD01


                           -26 dB Bandwidth and 99 % Occupied Bandwidth

             Report No.                12717479H
             Test place                Ise EMC Lab.
             Semi Anechoic Chamber     No.4
             Date                      February 17, 2019
             Temperature / Humidity    20 deg. C / 51 % RH
             Engineer                  Akihiko Maeda
             Mode                      Tx 125 kHz


                            -26 dB Bandwidth                 99 % Occupied Bandwidth
                                  [kHz]                               [kHz]
                                  24.170                             17.6155




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124


                                                                                       Test report No.       : 12717479H-A
                                                                                       Page                  : 17 of 19
                                                                                       Issued date           : March 14, 2019
                                                                                       FCC ID                : WAZSKESAD01


APPENDIX 2: Test instruments
Test Instruments
Test   LIMS ID   Description            Manufacturer          Model           Serial           Last            Calibration   Cal Int
item                                                                                           Calibration     Due Date
                                                                                               Date
RE     142226    Measure                KOMELON               KMC-36          -                -               -             -
RE     141998    AC1_Semi Anechoic      TDK                   Semi Anechoic   DA-06881         06/18/2018      06/30/2020    24
                 Chamber(NSA)                                 Chamber 10m
RE     141566    Thermo-Hygrometer      CUSTOM                CTH-201         A08Q26           01/11/2019      01/31/2020    12
RE     141254    Loop Antenna           Rohde & Schwarz       HFH2-Z2         100017           10/11/2018      10/31/2019    12
RE     141215    Coaxial Cable          Fujikura/Suhner/TSJ   5D-2W/3D-2W/    -/01068          06/04/2018      06/30/2019    12
                                                              RG400u/         (Switcher)
                                                              RFM-E421(SW)
RE     141582    Pre Amplifier          SONOMA                310             260834           02/08/2019      02/29/2020    12
                                        INSTRUMENT
RE     141213    Attenuator(6dB)        Weinschel Corp        2               BK7971           11/05/2018      11/30/2019    12
RE     141413    Coaxial Cable          UL Japan              -               -                06/12/2018      06/30/2019    12
RE     141530    Digital Tester         Fluke Corporation     FLUKE 26-3      78030621         08/21/2018      08/31/2019    12
RE     142011    AC4_Semi Anechoic      TDK                   Semi Anechoic   DA-10005         06/28/2018      06/30/2020    24
                 Chamber(NSA)                                 Chamber 3m
RE     141562    Thermo-Hygrometer      CUSTOM                CTH-201         0010             01/11/2019      01/31/2020    12
RE     141545    DIGITAL HiTESTER       HIOKI                 3805            51201148         01/29/2019      01/31/2020    12
RE     142227    Measure                KOMELON               KMC-36          -                -               -             -
RE     141901    Spectrum Analyzer      AGILENT               E4440A          MY48250080       10/04/2018      10/31/2019    12
RE     141397    Coaxial Cable          UL Japan              -               -                06/13/2018      06/30/2019    12
RE     141425    Biconical Antenna      Schwarzbeck           BBA9106         1302             06/01/2018      06/30/2019    12
RE     141267    Logperiodic            Schwarzbeck           VUSLP9111B      911B-192         06/01/2018      06/30/2019    12
                 Antenna(200-1000MHz)
RE     148898    Attenuator             KEYSIGHT              8491A           MY52462282       10/03/2018      10/31/2019    12
RE     141152    EMI measurement        TSJ                   TEPTO-DV        -                -               -             -
                 program
RE     141950    EMI Test Receiver      Rohde & Schwarz       ESU26           100412           06/15/2018      06/30/2019    12
RE     141949    Test Receiver          Rohde & Schwarz       ESCI            100767           08/06/2018      08/31/2019    12


*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration
is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test item:
         RE: Spurious emission




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone        : +81 596 24 8999
Facsimile        : +81 596 24 8124



Document Created: 2019-05-27 09:43:20
Document Modified: 2019-05-27 09:43:20

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC