03 FCC Test Report_DSC

FCC ID: WAZSKE13D03

Test Report

Download: PDF
FCCID_4160584

                                                                                 Test report No.        : 12589049H-A-R1
                                                                                 Page                   : 1 of 21
                                                                                 Issued date            : February 5, 2019
                                                                                 FCC ID                 : WAZSKE13D03



                              RADIO TEST REPORT
                                Test Report No. : 12589049H-A-R1
        Applicant                             :     Mitsubishi Electric Corporation Himeji works

        Type of Equipment                     :     Keyless System Hand Unit

        Model No.                             :     SKE13D-03

        FCC ID                                :     WAZSKE13D03

        Test regulation                       :     FCC Part 15 Subpart C: 2018

        Test Result                           :     Complied (Refer to Section 3.2)
           1.   This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
           2.   The results in this report apply only to the sample tested.
           3.   This sample tested is in compliance with the above regulation.
           4.   The test results in this report are traceable to the national or international standards.
           5.   This test report must not be used by the customer to claim product certification, approval, or
                endorsement by NVLAP, NIST, or any agency of the Federal Government.
           6.   This test report covers Radio technical requirements. It does not cover administrative issues
                such as Manual or non-Radio test related Requirements. (if applicable)
           7.   The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab.
           8.   The information provided from the customer for this report is identified in SECTION 1.
           9.   This report is a revised version of 12589049H-A. 12589049H-A is replaced with this report.

                         Date of test:                       December 2 and 11, 2018

                         Representative test
                         engineer:
                                                               Junki Nagatomi
                                                                  Engineer
                                                         Consumer Technology Division


                         Approved by:
                                                               Motoya Imura
                                                                   Leader
                                                         Consumer Technology Division

                                                            This laboratory is accredited by the NVLAP LAB CODE
                                                            200572-0, U.S.A. The tests reported herein have been
                                                            performed in accordance with its terms of accreditation.
                                                            *As for the range of Accreditation in NVLAP, you may
                                                            refer to the WEB address,
                                                            http://japan.ul.com/resources/emc_accredited/

       NVLAP LAB CODE: 200572-0

    The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan.
    There is no testing item of "Non-accreditation".

UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124                                                                             13-EM-F0429


                                                                       Test report No.   : 12589049H-A-R1
                                                                       Page              : 2 of 21
                                                                       Issued date       : February 5, 2019
                                                                       FCC ID            : WAZSKE13D03




                                  REVISION HISTORY
                             Original Test Report No.: 12589049H-A

Revision       Test report No.        Date               Page      Contents
                                                         revised
-              12589049H-A            January 30, 2019   -         -
(Original)
1              12589049H-A-R1         February 5, 2019   P.13      Correction of note sentences under “Radiated
                                                                   Emission (Electric Field Strength of
                                                                   Fundamental and Spurious Emission)” test
                                                                   data




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                Test report No.             : 12589049H-A-R1
                                                                                                Page                        : 3 of 21
                                                                                                Issued date                 : February 5, 2019
                                                                                                FCC ID                      : WAZSKE13D03


CONTENTS                                                                                                                                 PAGE

SECTION 1: Customer information........................................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ............................................................................................. 4
SECTION 3: Test specification, procedures & results.............................................................................. 5
SECTION 4: Operation of E.U.T. during testing ...................................................................................... 8
SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission) ... 9
SECTION 6: Automatically deactivate .................................................................................................... 11
SECTION 7: -20 dB and 99 % Occupied Bandwidth ............................................................................. 11
APPENDIX 1: Test data ............................................................................................................................ 12
    Automatically deactivate....................................................................................................................... 12
    Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) ......................... 13
    -20dB and 99% Occupied Bandwidth ................................................................................................... 15
    Duty Cycle ............................................................................................................................................ 16
APPENDIX 2: Test instruments ............................................................................................................... 18
APPENDIX 3: Photographs of test setup ................................................................................................. 19
    Radiated emission ................................................................................................................................. 19
    Worst case position ............................................................................................................................... 20




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                          Test report No.      : 12589049H-A-R1
                                                                          Page                 : 4 of 21
                                                                          Issued date          : February 5, 2019
                                                                          FCC ID               : WAZSKE13D03


SECTION 1:         Customer information
Company Name                            :    Mitsubishi Electric Corporation Himeji works
Address                                 :    840, Chiyoda-machi, Himeji, Hyogo 670-8677, Japan
Telephone Number                        :    +81-79-298-8994
Facsimile Number                        :    +81-79-298-9929
Contact Person                          :    Masashi Nojima

The information provided from the customer is as follows;
- Applicant, Type of Equipment, Model No. on the cover and other relevant pages
- SECTION 1: Customer information
- SECTION 2: Equipment under test (E.U.T.)
- SECTION 4: Operation of E.U.T. during testing
* The laboratory is exempted from liability of any test results affected from the information in SECTION 2 and 4.



SECTION 2:         Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

Type of Equipment                       :    Keyless System Hand Unit
Model No.                               :    SKE13D-03
Serial No.                              :    Refer to Section 4, Clause 4.2
Rating                                  :    DC 3.0 V
Receipt Date of Sample                  :    November 29, 2018
(Information from test lab.)
Country of Mass-production              :    Thailand
Condition of EUT                        :    Production prototype
                                             (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                     :    No Modification by the test lab


2.2       Product Description

Model: SKE13D-03 (referred to as the EUT in this report) is a Keyless System Hand Unit.

Radio Specification

RF Part
Equipment Type                          :    Transceiver
Type of modulation                      :    FSK
Frequency of operation                  :    315 MHz
Antenna Type                            :    Pattern antenna
Clock Frequency (maximum)               :    27.6 MHz

LF Part *
Type of Receiver                        :    Receiver
Frequency of operation                  :    125 kHz
Intermediate frequency                  :    -
Antenna Type                            :    Inductive

* The test of LF part was performed separately from this test report, and the conformability is confirmed.
LF Part test report No. 12589049H-B (FCC15B).




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                 Test report No.          : 12589049H-A-R1
                                                                                 Page                     : 5 of 21
                                                                                 Issued date              : February 5, 2019
                                                                                 FCC ID                   : WAZSKE13D03


 SECTION 3:               Test specification, procedures & results

 3.1        Test Specification

 Test Specification            :      FCC Part 15 Subpart C
                                      FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

 Title                         :      FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators
                                      Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.

 * Also the EUT complies with FCC Part 15 Subpart B.


 3.2        Procedures and results

Item                          Test Procedure          Specification               Worst margin Results              Remarks
                              FCC: ANSI C63.10:2013 FCC: Section 15.207
                              6 Standard test methods
Conducted emission                                                                N/A *1)           N/A             -
                              IC: RSS-Gen 8.8          IC: RSS-Gen 8.8


                              FCC: ANSI C63.10:2013 FCC: Section
                              6 Standard test methods 15.231(a)(1)                                  Complied
Automatically Deactivate                                                          N/A                               Radiated
                                                                                                    a)
                              IC: -                    IC: RSS-210 A1.1
                              FCC: ANSI C63.10:2013 FCC: Section 15.231(b)        1.2 dB
                              6 Standard test methods                             314.930 MHz
Electric Field Strength                                                                             Complied#
                                                                                  Horizontal                        Radiated
of Fundamental Emission                                                                             b)
                              IC: RSS-Gen 6.12         IC: RSS-210 A1.2           PK with Duty
                                                                                  factor
                              FCC: ANSI C63.10:2013 FCC: Section 15.205           10.7 dB
                              6 Standard test methods      Section 15.209         3150.000 MHz
Electric Field Strength                                                                             Complied
                                                           Section 15.231(b)      Horizontal                        Radiated
of Spurious Emission                                                                                c)
                              IC: RSS-Gen 6.13        IC: RSS-210 A1.2, 4.4       PK with Duty
                                                          RSS-Gen 8.9             factor
                              FCC: ANSI C63.10:2013 FCC: Section 15.231(c)
                              6 Standard test methods
                                                                                                    Complied
-20dB Bandwidth                                                                   N/A                               Radiated
                                                                                                    d)
                              IC: -                    IC: Reference data

Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.
*1) The test is not applicable since the EUT does not have AC Mains.

a) Refer to APPENDIX 1 (data of Automatically Deactivate)
b) Refer to APPENDIX 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission))
c) Refer to APPENDIX 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission))
d) Refer to APPENDIX 1 (data of -20dB and 99% Occupied Bandwidth)
Symbols:
 Complied           The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#          The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

 FCC 15.31 (e)
 This test was performed with the New Battery (DC 3.0 V) during the tests. Therefore, the EUT complies with the
 requirement.

 FCC Part 15.203 Antenna requirement
 It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the
 equipment complies with the antenna requirement of Section 15.203.


 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone : +81 596 24 8999
 Facsimile : +81 596 24 8124


                                                                                  Test report No.        : 12589049H-A-R1
                                                                                  Page                   : 6 of 21
                                                                                  Issued date            : February 5, 2019
                                                                                  FCC ID                 : WAZSKE13D03


 3.3         Addition to standard

Item                       Test Procedure    Specification        Worst margin               Results               Remarks
99 % Occupied                                                                                Complied
                           IC: RSS-Gen 6.7 IC: RSS-210 A1.3       N/A                                              Radiated
Bandwidth                                                                                    a)
Note: UL Japan, Inc.’s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422.

a) Refer to Appendix 1 (data of -20dB and 99% Occupied Bandwidth)
Symbols:
 Complied           The data of this test item has enough margin, more than the measurement uncertainty.
 Complied#          The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.
 Other than above, no addition, exclusion nor deviation has been made from the standard.


 3.4         Uncertainty

 There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived depending on
 whether or not laboratory uncertainty is applied.

 The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.


                                       Radiated emission
           Test distance                     (+/-)

                                        9 kHz to 30 MHz
   3m                                       3.8 dB
   10 m                                     3.6 dB
 *Measurement distance

                                                Radiated emission (Below 1 GHz)
       Polarity                     (3 m*)(+/-)                                 (10 m*)(+/-)
                     30 MHz to 200 MHz    200 MHz to 1000 MHz    30 MHz to 200 MHz    200 MHz to 1000 MHz
       Horizontal         4.8 dB                5.2 dB                  4.8 dB               5.0 dB
        Vertical          5.0 dB                6.3 dB                  4.9 dB               5.0 dB

                                              Radiated emission (Above 1 GHz)
                  (3 m*)(+/-)                                     (1 m*)(+/-)                             (10 m*)(+/-)
     1 GHz to 6 GHz      6 GHz to 18 GHz        10 GHz to 26.5 GHz      26.5 GHz to 40 GHz              1 GHz to 18 GHz
          5.2 dB              5.5 dB                   5.9 dB                 5.9 dB                         5.5 dB
 * Measurement distance

    Automatically Deactivate
    0.10 %

    Bandwidth
    0.96 %




 UL Japan, Inc.
 Ise EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone : +81 596 24 8999
 Facsimile : +81 596 24 8124


                                                                               Test report No.         : 12589049H-A-R1
                                                                               Page                    : 7 of 21
                                                                               Issued date             : February 5, 2019
                                                                               FCC ID                  : WAZSKE13D03


3.5         Test Location

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124
NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967
                                                                                                                    Maximum
                     IC Registration Width x Depth x      Size of reference ground plane (m)
Test site                                                                                    Other rooms            measuremen
                     Number          Height (m)           / horizontal conducting plane
                                                                                                                    t distance
No.1 semi-anechoic                                                                               No.1 Power
                     2973C-1         19.2 x 11.2 x 7.7    7.0 x 6.0                                                 10 m
chamber                                                                                          source room
No.2 semi-anechoic
                     2973C-2         7.5 x 5.8 x 5.2      4.0 x 4.0                              -                  3m
chamber
No.3 semi-anechoic                                                                               No.3 Preparation
                     2973C-3         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.3 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.4 semi-anechoic                                                                               No.4 Preparation
                     2973C-4         12.0 x 8.5 x 5.9     6.8 x 5.75                                                3m
chamber                                                                                          room
No.4 shielded room   -               4.0 x 6.0 x 2.7      N/A                                    -                  -
No.5 semi-anechoic
                     -               6.0 x 6.0 x 3.9      6.0 x 6.0                              -                  -
chamber
No.6 shielded room   -               4.0 x 4.5 x 2.7      4.0 x 4.5                              -                  -
No.6 measurement
                     -               4.75 x 5.4 x 3.0     4.75 x 4.15                            -                  -
room
No.7 shielded room   -               4.7 x 7.5 x 2.7      4.7 x 7.5                              -                  -
No.8 measurement
                     -               3.1 x 5.0 x 2.7      3.1 x 5.0                              -                  -
room
No.9 measurement
                     -               8.8 x 4.6 x 2.8      2.4 x 2.4                              -                  -
room
No.11 measurement
                     -               6.2 x 4.7 x 3.0      4.8 x 4.6                              -                  -
room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4
semi-anechoic chambers and No.3 and No.4 shielded rooms.



3.6         Test data, Test instruments, and Test set up

Refer to APPENDIX.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.        : 12589049H-A-R1
                                                                         Page                   : 8 of 21
                                                                         Issued date            : February 5, 2019
                                                                         FCC ID                 : WAZSKE13D03


SECTION 4:         Operation of E.U.T. during testing

4.1       Operating Mode(s)

Test Item*                                              Mode
Automatically Deactivate                                Normal use mode
-20 dB & 99 % Occupied Bandwidth
Duty Cycle
Electric Field Strength of Fundamental Emission         Transmitting mode (Tx) 315 MHz *1)
Electric Field Strength of Spurious Emission
* The system was configured in typical fashion (as a user would normally use it) for testing.
*1) End users cannot change the settings of the output power of the product.



4.2       Configuration and peripherals




                                                              A




                                   * Test data was taken under worse case conditions.

Description of EUT
 No. Item                         Model number        Serial number      Manufacturer                         Remarks
 A    Keyless System Hand         SKE13D-03           20181129-T1 (No.1) Mitsubishi Electric                  EUT
      Unit                                            *1)                Corporation Himeji works
                                                      20181129-T3 (No.3)
                                                      *2)
*1) Used for Transmitting mode.
*2) Used for Normal use mode.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                         Test report No.         : 12589049H-A-R1
                                                                         Page                    : 9 of 21
                                                                         Issued date             : February 5, 2019
                                                                         FCC ID                  : WAZSKE13D03


SECTION 5:          Radiated emission (Electric Field Strength of Fundamental and Spurious
Emission)
Test Procedure and conditions

[For below 30 MHz]
The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.

[For 30 MHz to 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground
plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz]
EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground
plane.
The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined on
a ground plane.

The measuring antenna height was varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field strength.
The measurements were performed for both vertical and horizontal antenna polarization.
The radiated emission measurements were made with the following detector function of the test receiver / spectrum
analyzer.

Test Antennas are used as below;
   Frequency            Below 30 MHz              30 MHz to 200 MHz      200 MHz to 1 GHz           Above 1 GHz
   Antenna Type         Loop                      Biconical              Logperiodic                Horn

                    From 9 kHz          From             From            From           From               Above 1 GHz
                   to 90 kHz and       90 kHz          150 kHz         490 kHz         30 MHz
                   From 110 kHz      to 110 kHz       to 490 kHz      to 30 MHz       to 1 GHz
                     to 150 kHz
  Detector              Peak            Peak             Peak           Peak          Peak and       Peak and
  Type                                                                               Peak with       Peak with Duty factor
                                                                                     Duty factor
  IF Bandwidth        200 Hz           200 Hz          9.0 kHz         9.0 kHz        120 kHz        PK: S/A: RBW 1 MHz,
                                                                                                            VBW: 3 MHz




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.        : 12589049H-A-R1
                                                                            Page                   : 10 of 21
                                                                            Issued date            : February 5, 2019
                                                                            FCC ID                 : WAZSKE13D03


[Test Setup]

Below 1 GHz
                                                               Test Distance: 3 m




1 GHz - 10 GHz
                                                               Distance Factor: 20 x log (3.75 m / 3.0 m) = 1.94 dB
                                                               * Test Distance: (3 + Test Volume /2) - r = 3.75 m

                                                               Test Volume : 1.5 m
                                                               (Test Volume has been calibrated based on CISPR 16-1-4.)
                                                                r = 0.0 m

                                                               * The test was performed with r = 0.0 m since EUT is small
                                                               and it was the rather conservative condition.




- The carrier level (or, noise levels) was (or were) measured at each position of all three axes X, Y and Z, and the
position that has the maximum noise was determined.
Noise levels of all the frequencies were measured at the position.

This EUT has two modes which mechanical key is inserted or not. The worst case was confirmed with and without
mechanical key, as a result, the test without mechanical key was the worst case. Therefore the test without mechanical
key was performed only.

*The result is rounded off to the second decimal place, so some differences might be observed.


Measurement range               : 9 kHz - 3.2 GHz
Test data                       : APPENDIX
Test result                     : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                      Test report No.       : 12589049H-A-R1
                                                                                      Page                  : 11 of 21
                                                                                      Issued date           : February 5, 2019
                                                                                      FCC ID                : WAZSKE13D03


SECTION 6:             Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data                           : APPENDIX
Test result                         : Pass



SECTION 7:             -20 dB and 99 % Occupied Bandwidth
Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test                Span                       RBW           VBW              Sweep           Detector    Trace       Instrument used
20 dB Bandwidth     2 MHz                     9.1 kHz       30 kHz            Auto             Peak       Max Hold    Spectrum Analyzer
99 % Occupied       Enough width to display   1 to 5 %      Three times       Auto             Peak *1)   Max Hold    Spectrum Analyzer
Bandwidth           emission skirts           of OBW        of RBW                                        *1)
*1) The measurement was performed with Peak detector, Max Hold since the duty cycle was not 100 %.
Peak hold was applied as Worst-case measurement.

Test data                           : APPENDIX
Test result                         : Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                       Test report No.          : 12589049H-A-R1
                                                                       Page                     : 12 of 21
                                                                       Issued date              : February 5, 2019
                                                                       FCC ID                   : WAZSKE13D03


APPENDIX 1: Test data

                                           Automatically deactivate

          Report No.                12589049H
          Test place                Ise EMC Lab.
          Semi Anechoic Chamber     No.3
          Date                      December 11, 2018
          Temperature / Humidity    24 deg. C / 38 % RH
          Engineer                  Junki Nagatomi
          Mode                      Normal use mode

                             Time of                       Limit                     Result
                           Transmitting
                              [sec]                        [sec]
                               0.35                        5.00                          Pass




* The EUT transmits UHF when LF signal is received from a car or a button on the EUT is pressed. In both cases, the
UHF transmission is stopped within 5 seconds. So the test was performed by a button-pressed operation as the worst
case.
Please refer to the “Theory of Operation” for details.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                               Test report No.           : 12589049H-A-R1
                                                                                               Page                      : 13 of 21
                                                                                               Issued date               : February 5, 2019
                                                                                               FCC ID                    : WAZSKE13D03


      Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)
                  Report No.                      12589049H
                  Test place                      Ise EMC Lab.
                  Semi Anechoic Chamber           No.2
                  Date                            December 2, 2018
                  Temperature / Humidity          23 deg. C / 41 % RH
                  Engineer                        Akihiko Maeda
                  Mode                            Transmitting mode (Tx) 315 MHz
  PK
    Frequency      Detector     Reading          Ant     Loss     Gain      Duty           Result       Limit       Margin                 Remark
                                [dBuV]         Factor                      Factor        [dBuV/m]                    [dB]             Inside or Outside
      [MHz]                   Hor     Ver      [dB/m]    [dB]     [dB]      [dB]        Hor       Ver [dBuV/m]   Hor      Ver       of Restricted Bands
        314.930   PK           85.8     82.2      13.9      9.0     29.3            -    79.4      75.8   95.6    16.2     19.8   Carrier
        315.070   PK           85.7     82.1      13.9      9.0     29.3            -    79.3      75.7   95.6    16.3     19.9   Carrier
        629.860   PK           44.5     47.1      19.3     10.3     29.5            -    44.6      47.2   75.6    31.0     28.4   Outside
        944.790   PK           34.6     36.7      21.9     11.5     27.8            -    40.2      42.3   75.6    35.4     33.3   Outside
       1260.000   PK           46.1     46.4      25.3      3.8     35.3            -    39.9      40.2   75.6    35.7     35.4   Outside
       1575.000   PK           45.0     45.2      25.4      4.0     35.0            -    39.4      39.6   73.9    34.5     34.3   Inside
       1890.000   PK           45.8     45.8      25.8      4.2     34.7            -    41.1      41.1   75.6    34.5     34.5   Outside
       2205.000   PK           44.5     44.0      27.9      4.4     34.5            -    42.3      41.8   73.9    31.6     32.1   Inside
       2520.000   PK           45.1     44.5      27.8      4.6     34.4            -    43.1      42.5   75.6    32.5     33.1   Outside
       2835.000   PK           44.1     43.8      28.4      4.7     34.4            -    42.8      42.5   73.9    31.1     31.4   Inside
       3150.000   PK           45.6     44.7      28.6      4.9     34.2            -    44.9      44.0   75.6    30.7     31.6   Outside



  AV (PK with Duty factor)
    Frequency    Detector       Reading          Ant     Loss     Gain      Duty           Result       Limit       Margin                  Remark
                                [dBuV]         Factor                      Factor        [dBuV/m]                    [dB]
      [MHz]                   Hor     Ver      [dB/m]    [dB]     [dB]      [dB]        Hor       Ver [dBuV/m]   Hor      Ver
        314.930   PK           85.8     82.2      13.9      9.0     29.3      -5.0       74.4      70.8   75.6     1.2      4.8   Carrier                 キ
        315.070   PK           85.7     82.1      13.9      9.0     29.3      -5.0       74.3      70.7   75.6     1.3      4.9   Carrier                 キ
        629.860   PK           44.5     47.1      19.3     10.3     29.5      -5.0       39.6      42.2   55.6    16.0     13.4   Outside                 キ
        944.790   PK           34.6     36.7      21.9     11.5     27.8      -5.0       35.2      37.3   55.6    20.4     18.3   Outside
       1260.000   PK           46.1     46.4      25.3      3.8     35.3       0.0       39.9      40.2   55.6    15.7     15.4   Outside
       1575.000   PK           45.0     45.2      25.4      4.0     35.0       0.0       39.4      39.6   53.9    14.5     14.3   Inside
       1890.000   PK           45.8     45.8      25.8      4.2     34.7       0.0       41.1      41.1   55.6    14.5     14.5   Outside
       2205.000   PK           44.5     44.0      27.9      4.4     34.5       0.0       42.3      41.8   53.9    11.6     12.1   Inside
       2520.000   PK           45.1     44.5      27.8      4.6     34.4       0.0       43.1      42.5   55.6    12.5     13.1   Outside
       2835.000   PK           44.1     43.8      28.4      4.7     34.4       0.0       42.8      42.5   53.9    11.1     11.4   Inside
       3150.000   PK           45.6     44.7      28.6      4.9     34.2       0.0       44.9      44.0   55.6    10.7     11.6   Outside


Sample calculation:
Result of PK = Reading + Ant Factor + Loss {Cable + Attenuator + Distance factor (above 1 GHz)} - Gain (Amplifier)
Result of PK with Duty factor = Reading + Ant Factor + Loss {Cable + Attenuator + Distance factor (above 1 GHz)} - Gain
(Amplifier) + Duty factor

For above 1GHz : Distance Factor: 20 x log (3.75 m/3.0 m) = 1.94 dB
*Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).


* As for the Average value, the measured duty factor was obtained by tuning to the peak level was applied since the
FSK modulation peak to peak bandwidth of the fundamental and harmonic (below 1GHz) are greater than 120 kHz
(RBW bandwidth).

Harmonic test (Above 1GHz) was applied to worst 100% (Duty factor = 0) although Duty Factor was applied in
harmonic test which peak to peak frequency bandwidth of FSK modulation is equal to or more than measurement
bandwidth (1MHz).




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                                      Test report No.          : 12589049H-A-R1
                                                                                                      Page                     : 14 of 21
                                                                                                      Issued date              : February 5, 2019
                                                                                                      FCC ID                   : WAZSKE13D03


                                                                     Radiated Spurious Emission
                                                                       (Plot data, Worst case)

             Report No.                                          12589049H
             Test place                                          Ise EMC Lab.
             Semi Anechoic Chamber                               No.2
             Date                                                December 2, 2018
             Temperature / Humidity                              23 deg. C / 41 % RH
             Engineer                                            Akihiko Maeda
             Mode                                                Transmitting mode (Tx) 315 MHz



                                                                               Horizontal
                                              100
                                              90
                                              80
                    Field strength [dBuV/m]




                                              70
                                              60
                                              50
                                              40
                                              30
                                              20
                                              10
                                               0
                                                    10                 100                    1000                10000
                                                                                   Frequency [MHz]

                                                         QP   Peak       Average       QP Limit      Peak Limit      Average Limit



                                                                                   Vertical
                                              100
                                              90
                                              80
                    Field strength [dBuV/m]




                                              70
                                              60
                                              50
                                              40
                                              30
                                              20
                                              10
                                               0
                                                    10                 100                    1000                10000
                                                                                   Frequency [MHz]

                                                         QP   Peak       Average       QP Limit      Peak Limit      Average Limit


           *These plots data contains sufficient number to show the trend of characteristic features for EUT.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                              Test report No.      : 12589049H-A-R1
                                                                              Page                 : 15 of 21
                                                                              Issued date          : February 5, 2019
                                                                              FCC ID               : WAZSKE13D03


                                     -20dB and 99% Occupied Bandwidth
          Report No.                  12589049H
          Test place                  Ise EMC Lab.
          Semi Anechoic Chamber       No.3
          Date                        December 11, 2018
          Temperature / Humidity      24 deg. C / 38 % RH
          Engineer                    Junki Nagatomi
          Mode                        Normal use mode


               Bandwidth Limit : Fundamental Frequency      315.00 MHz x 0.25% =         787.50   kHz
                 * The above limit was calculated from more stringent nominal frequency.

                   -20dB Bandwidth             Bandwidth Limit           Result
                        [kHz]                       [kHz]
                       199.410                     787.50                 Pass

               99% Occupied Bandwidth          Bandwidth Limit           Result
                       [kHz]                        [kHz]
                     210.4798                      787.50                 Pass




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                                   Test report No.       : 12589049H-A-R1
                                                                                   Page                  : 16 of 21
                                                                                   Issued date           : February 5, 2019
                                                                                   FCC ID                : WAZSKE13D03


                                                            Duty Cycle
          Report No.                   12589049H
          Test place                   Ise EMC Lab.
          Semi Anechoic Chamber        No.3
          Date                         December 11, 2018
          Temperature / Humidity       24 deg. C / 38 % RH
          Engineer                     Junki Nagatomi
          Mode                         Normal use mode



            Pulse   ON time(One pulse)              Pulse count (Sweep time : 4mS)               Pulse count    ON time(in 20ms)
            type          [ms]                1         2          3         4           5      sum (in 20ms)         [ms]
              A             0.276            4          0         2          0           3             9              2.484
              B             0.152            8          4         4          0          10            26              3.952
              C             0.400            0          4         3          5           0            12               4.8
                                                                                       Total on time in 20mS         11.236
          The train of pulses was exceeding 100msec, and that sampled 100msec was the worst case against the pulse train.


          (Total)
              ON time in 100mS *1)             Cycle                   Duty                    Duty
                      [ms]                      [ms]             (On time/Cycle)                [dB]
                     56.18                    100.00                  0.56                     -5.01
          *1)ON time in 100mS = Total on time in 20mS * 5




                                                   Pulse Train in 100ms




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                   Test report No.        : 12589049H-A-R1
                                                                   Page                   : 17 of 21
                                                                   Issued date            : February 5, 2019
                                                                   FCC ID                 : WAZSKE13D03


                                                      Duty Cycle

                    Pulse count       1                                     Pulse count       2
                            Type A                                 Type B            Type C




                    Pulse count       3                                     Pulse count       4




                    Pulse count       5




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124


                                                                            Test report No.          : 12589049H-A-R1
                                                                            Page                     : 18 of 21
                                                                            Issued date              : February 5, 2019
                                                                            FCC ID                   : WAZSKE13D03


APPENDIX 2: Test instruments
Test Instruments
Test   LIMS ID   Description         Manufacturer        Model        Serial              Last             Calibration    Cal
item                                                                                      Calibration      Due Date       Int
                                                                                          Date
RE     142004    AC2_Semi            TDK                 Semi         DA-06902            6/29/2018        6/30/2020      24
                 Anechoic                                Anechoic
                 Chamber(NSA)                            Chamber 3m
RE     141942    Test Receiver       Rohde & Schwarz     ESCI         100300              8/8/2018         8/31/2019      12
RE     141392    Microwave Cable     Junkosha            MWX221       1604S253(1 m) /     8/8/2018         8/31/2019      12
                                                                      1608S087(5 m)
RE     142228    Measure             KOMELON             KMC-36       -                   -                -              -
RE     141503    Horn Antenna        EMCO                22160        1265                6/6/2018         6/30/2019      12
                 18-26.5GHz
RE     141512    Horn Antenna        Schwarzbeck         BBHA9120D    254                 6/6/2018         6/30/2019      12
                 1-18GHz
RE     141152    EMI measurement     TSJ                 TEPTO-DV     -                   -                -              -
                 program
RE     141542    Digital Tester      Fluke Corporation   FLUKE 26-3   78030611            8/21/2018        8/31/2019      12
RE     142006    AC2_Semi            TDK                 Semi         DA-06902            4/1/2018         4/30/2019      12
                 Anechoic                                Anechoic
                 Chamber(SVSWR)                          Chamber 3m
RE     141556    Thermo-Hygrometer   CUSTOM              CTH-201      0003                12/5/2018        12/31/2019     12
RE     141317    Coaxial Cable       Fujikura/Agilent    -            -                   2/23/2018        2/28/2019      12
RE     141542    Digital Tester      Fluke Corporation   FLUKE 26-3   78030611            8/21/2018        8/31/2019      12
RE     141265    Logperiodic         Schwarzbeck         VUSLP9111B   911B-190            5/31/2018        5/31/2019      12
                 Antenna(200-1000
                 MHz)
RE     141578    Pre Amplifier       AGILENT             8447D        2944A10845          9/19/2018        9/30/2019      12
RE     141885    Spectrum Analyzer   AGILENT             E4448A       US44300523          11/7/2018        11/30/2019     12
RE     141203    Attenuator(6dB)     Weinschel Corp      2            BK7970              11/5/2018        11/30/2019     12
RE     141427    Biconical Antenna   Schwarzbeck         VHA9103B     8031                5/31/2018        5/31/2019      12
RE     141579    Pre Amplifier       AGILENT             8449B        3008A02142          1/23/2018        1/31/2019      12
RE     142645    Loop Antenna        UL Japan            -            -                   -                -              -

*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration
is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month.
All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

Test item:
RE: Radiated emission, 99 % Occupied Bandwidth, -20 dB bandwidth, Automatically deactivate and Duty cycle
tests




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone : +81 596 24 8999
Facsimile : +81 596 24 8124



Document Created: 2019-02-05 13:42:46
Document Modified: 2019-02-05 13:42:46

© 2024 FCC.report