RF Exposure Report

FCC ID: WAP2011

RF Exposure Info

Download: PDF
FCCID_3202271

          RF Exposure Evaluation Declaration


                    Product Name : EZ-BLE PRoC Module
                    Model No.               : CYBLE-012011-00,
                                               CYBLE-212019-00,
                                               CYBLE-212020-01
                    FCC ID                  : WAP2011



      Applicant : Cypress Semiconductor
      Address         : 198 Champion Ct, San Jose, California 95134 United
                          States




                     Date of Receipt : Oct. 21, 2016
                     Issued Date              : Nov. 14, 2016
                     Report No.               : 16A2077C-RF-US-P20V02
                     Report Version : V1.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by CNAS, TAF or any agency of the government.
The test report shall not be reproduced without the written approval of QuieTek Corporation.


                                                   Report No: 16A2077C-RF-US-P20V02



               Tes t R e p o r t C e r t i f i c a t i o n
                                                 Issued Date : Nov. 14, 2016
                                                 Report No. : 16A2077C-RF-US-P20V02




Product Name          :   EZ-BLE PRoC Module
Applicant             :   Cypress Semiconductor
Address               :   198 Champion Ct, San Jose, California 95134 United
                          States
Manufacturer          :   Wujiang Sigmatron Electronics Co., Ltd
Address               :   386 Huahong Rd, Wujiang, Suzhou, Jiangsu, China
Model No.             :   CYBLE-012011-00,
                          CYBLE-212019-00,
                          CYBLE-212020-01
FCC ID                :   WAP2011
EUT Voltage           :   DC 1.9V~5.5V
Applicable Standard   :   KDB 447498 D01v06
Test Result           :   Complied
Performed Location    :   Quietek Corporation - Suzhou EMC Laboratory
                          No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
                          215006, Jiangsu, China
                          TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                          FCC Registration Number: 800392;



Documented By         :

                                  ( Adm. Specialist: Kathy Feng )

Reviewed By           :

                                     (Senior Engineer: Frank He )

Approved By           :

                                (Engineering Manager: Harry Zhao )




                                 Page: 2 of 6


                                                                Report No: 16A2077C-RF-US-P20V02



Laboratory Information


We, QuieTek Corporation, are an independent EMC and safety consultancy that was
established the whole facility in our laboratories. The test facility has been
accredited/accepted(audited or listed) by the following related bodies in compliance with ISO
17025, EN 45001 and specified testing scope:


 Taiwan R.O.C.          :   BSMI, NCC, TAF
 USA                    :   FCC
 Japan                  :   VCCI
 China                  :   CNAS


The related certificate for our laboratories about the test site and management system can be downloaded
from QuieTek Corporation’s Web Site : http://www.quietek.com/english/about/certificates.aspx?bval=5
The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
http://www.quietek.com/index_en.aspx
If you have any comments, Please don’t hesitate to contact us. Our contact information is as below:

 HsinChu Testing Laboratory :
 No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C.
 TEL:+886-3-592-8858 / FAX:+886-3-592-8859              E-Mail : service@quietek.com

 LinKou Testing Laboratory :
 No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C.
 TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789            E-Mail : service@quietek.com


 Suzhou Testing Laboratory :
 No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China
 TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : service@quietek.com




                                             Page: 3 of 6


                                                                   Report No: 16A2077C-RF-US-P20V02


1. RF Exposure Evaluation

1.1. Limits

According to KDB 447498 D01 General RF Exposure Guidance v06
4.3.1 Standalone SAR test exclusion considerations
1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)]
≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where
• f(GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation
• The result is rounded to one decimal place for comparison
• 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
determined according to the following, and as illustrated in Appendix B:
a) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·( f(MHz)/150)] mW, at 100 MHz to 1500 MHz
b) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·10] mW at > 1500 MHz and ≤ 6 GHz


3) The 1-g and 10-g SAR test exclusion thresholds for below 100 MHz at test separation distances ≤ 50 mm
are determined by:
a) The power threshold at the corresponding test separation distance at 100 MHz in step 2) is
multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm
b) The power threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
separation distances ≤ 50 mm
c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be
applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be
acceptable. Note: when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
determine SAR test exclusion.




                                               Page: 4 of 6


                                                                 Report No: 16A2077C-RF-US-P20V02


1.2. Test Procedure

     Software provided by client enabled the EUT to transmit and receive data at lowest, middle
     and highest channel individually.
     The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

      Product           :   EZ-BLE PRoC Module
      Test Item         :   RF Exposure Evaluation
      Test Site         :   AC-6


         Antenna Gain:


Model No.                    N/A
Antenna manufacturer         N//A
Antenna Delivery                    1*TX+1*RX                  2*TX+2*RX           3*TX+3*RX
Antenna technology                  SISO
                                                      Basic
                                    MIMO              CDD
                                                      Beam-forming
Antenna Type                        External          Dipole
                                                      PIFA
                                                      PCB
                                    Internal
                                                      Ceramic Chip Antenna
                                                      Metal plate type F antenna
Antenna Gain                 -0.5dBi




Based on The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm and the formula below:




                                               Page: 5 of 6


                                                                  Report No: 16A2077C-RF-US-P20V02


                                                                     Stand-alone
                    Pmax Pmax      Distance
        Exposure                                       calculation      Test
 Band                                         f(GHz)                               SAR Test
        Condition                                        result       exclusion
                    (dBm)   (mw)    (mm)
                                                                      threshold
  BT      Body      0.46    1.11      5       2.402      0.344          3.00         No


Conclusion: 2400MHz-2480MHz SAR was not required.




                                                The End




                                              Page: 6 of 6



Document Created: 2019-07-02 12:16:38
Document Modified: 2019-07-02 12:16:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC