RF Exposure Report

FCC ID: WAP2005

RF Exposure Info

Download: PDF
FCCID_3202287

          RF Exposure Evaluation Declaration


         Product Name : EZ-BLE PRoC Module
         Model No.               : CYBLE-222014-01/CYBLE-222005-00
         FCC ID                  : WAP2005




      Applicant : Cypress Semiconductor
      Address         : 198 Champion Ct, San Jose, California 95134 United
                          States




                     Date of Receipt : Oct. 21, 2016
                     Issued Date              : Nov. 14, 2016
                     Report No.               : 16A2076C-RF-US-P20V02
                     Report Version : V1.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by CNAS, TAF or any agency of the government.
The test report shall not be reproduced without the written approval of QuieTek Corporation.


                                                    Report No: 16A2076C-RF-US-P20V02



               Tes t R e p o r t C e r t i f i c a t i o n
                                                 Issued Date : Nov. 14, 2016
                                                 Report No. : 16A2076C-RF-US-P20V02




Product Name          :   EZ-BLE PRoC Module
Applicant             :   Cypress Semiconductor
Address               :   198 Champion Ct, San Jose, California 95134 United
                          States
Manufacturer          :   Wujiang Sigmatron Electronics Co., Ltd
Address               :   386 Huahong Rd, Wujiang, Suzhou, Jiangsu, China
Model No.             :   CYBLE-222014-01/CYBLE-222005-00
FCC ID                :   WAP2005
EUT Voltage           :   DC 3.3V
Applicable Standard   :   KDB 447498 D01v06
Test Result           :   Complied
Performed Location    :   Quietek Corporation - Suzhou EMC Laboratory
                          No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
                          215006, Jiangsu, China
                          TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                          FCC Registration Number: 800392;



Documented By         :

                                    ( Adm. Specialist: Kathy Feng )

Reviewed By           :

                                     (Senior Engineer: Frank He )

Approved By           :

                                (Engineering Manager : Harry Zhao )




                                 Page: 2 of 5


                                                                Report No: 16A2076C-RF-US-P20V02



Laboratory Information


We, QuieTek Corporation, are an independent EMC and safety consultancy that was
established the whole facility in our laboratories. The test facility has been
accredited/accepted(audited or listed) by the following related bodies in compliance with ISO
17025, EN 45001 and specified testing scope:


 Taiwan R.O.C.          :   BSMI, NCC, TAF
 USA                    :   FCC
 Japan                  :   VCCI
 China                  :   CNAS


The related certificate for our laboratories about the test site and management system can be downloaded
from QuieTek Corporation’s Web Site : http://www.quietek.com/english/about/certificates.aspx?bval=5
The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
http://www.quietek.com/index_en.aspx
If you have any comments, Please don’t hesitate to contact us. Our contact information is as below:

 HsinChu Testing Laboratory :
 No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C.
 TEL:+886-3-592-8858 / FAX:+886-3-592-8859              E-Mail : service@quietek.com

 LinKou Testing Laboratory :
 No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C.
 TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789            E-Mail : service@quietek.com


 Suzhou Testing Laboratory :
 No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China
 TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : service@quietek.com




                                             Page: 3 of 5


                                                                   Report No: 16A2076C-RF-US-P20V02


1. RF Exposure Evaluation

1.1. Limits

According to KDB 447498 D01 General RF Exposure Guidance v06
4.3.1 Standalone SAR test exclusion considerations
1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√f(GHz)]
≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,where
• f(GHz) is the RF channel transmit frequency in GHz
• Power and distance are rounded to the nearest mW and mm before calculation
• The result is rounded to one decimal place for comparison
• 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
determined according to the following, and as illustrated in Appendix B:
a) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·( f(MHz)/150)] mW, at 100 MHz to 1500 MHz
b) [Power allowed at numeric threshold for 50 mm in step 1) + (test separation distance - 50
mm)·10] mW at > 1500 MHz and ≤ 6 GHz


3) The 1-g and 10-g SAR test exclusion thresholds for below 100 MHz at test separation distances ≤ 50 mm
are determined by:
a) The power threshold at the corresponding test separation distance at 100 MHz in step 2) is
multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm
b) The power threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
separation distances ≤ 50 mm
c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot be
applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to be
acceptable. Note: when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
determine SAR test exclusion.




                                               Page: 4 of 5


                                                                      Report No: 16A2076C-RF-US-P20V02


1.2. Test Procedure

       Software provided by client enabled the EUT to transmit and receive data at lowest, middle
       and highest channel individually.
       The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

       Product             :    EZ-BLE PRoC Module
       Test Item           :    RF Exposure Evaluation
       Test Site           :    AC-6


           Antenna Gain:


Antenna                        Manufacturer                Model No.                   Peak Gain
Ceramic Antenna                N/A                         N/A                         0.5dBi

Based on The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm and the formula below:




                                                                         Stand-alone
                       Pmax Pmax       Distance
           Exposure                                        calculation      Test
 Band                                             f(GHz)                               SAR Test
           Condition                                         result       exclusion
                       (dBm)   (mw)     (mm)
                                                                          threshold
  BT         Body      -1.19   0.76       5       2.480      0.239          3.00         No


Conclusion: 2400MHz-2480MHz SAR was not required.




                                                    The End




                                                  Page: 5 of 5



Document Created: 2017-12-18 03:00:16
Document Modified: 2017-12-18 03:00:16