RF Exposure report

FCC ID: WAP2005

RF Exposure Info

Download: PDF
FCCID_2945384

          RF Exposure Evaluation Declaration


                    Product Name : EZ-BLE PRoC Module
                    Model No.               : CYBLE-222014-01
                    FCC ID                  : WAP2005
                    IC                      : 7922A-2005




         Applicant : Cypress Semiconductor Corporation
         Address : 198 Champion Ct, San Jose, California 95134
                            United States




               Date of Receipt : Feb. 24, 2016
               Test Date               : Feb. 24, 2016 ~ Mar. 04, 2016
               Issued Date             : Mar. 24, 2016
               Report No.              : 1622078R-RF-US-P20V01
               Report Version : V2.0




The test results relate only to the samples tested.
The test results shown in the test report are traceable to the national/international standard through the
calibration of the equipment and evaluated measurement uncertainty herein.
This report must not be used to claim product endorsement by TAF or any agency of the government.
The test report shall not be reproduced without the written approval of QuieTek Corporation.


                                                          Report No: 1622078R-RF-US-P20V01



               Tes t R e p o r t C e r t i f i c a t i o n
                                                   Issued Date : Mar. 24, 2016
                                                   Report No. : 1622078R-RF-US-P20V01




Product Name          :   EZ-BLE PRoC Module
Applicant             :   Cypress Semiconductor Corporation
Address               :   198 Champion Ct, San Jose, California 95134 United
                          States
Manufacturer          :   Wujiang Sigmatron Electronics Co., Ltd
Address               :   386 Huahong Rd, Wujiang, Suzhou, Jiangsu, China
Model No.             :   CYBLE-222014-01
FCC ID                :   WAP2005
IC                    :   7922A-2005
EUT Voltage           :   DC 3.3V
Applicable Standard   :   KDB 447498D01V06
                          FCC Part1.1310(b)
Test Result           :   Complied
Performed Location    :   Suzhou EMC Laboratory
                          No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,
                          215006, Jiangsu, China
                          TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
                          FCC Registration Number: 800392


Documented By         :

                                   (Senior Adm. Specialist: Alice Ni )

Reviewed By           :

                                    (Senior Engineer: Jack Zhang )

Approved By           :

                              (Engineering Manager : Harry Zhao )




                                    Page: 2 of 7


                                                                   Report No: 1622078R-RF-US-P20V01



Laboratory Information


We, QuieTek Corporation, are an independent EMC and safety consultancy that was
established the whole facility in our laboratories. The test facility has been
accredited/accepted(audited or listed) by the following related bodies in compliance with ISO
17025, EN 45001 and specified testing scope:


 Taiwan R.O.C.          :   BSMI, NCC, TAF
 USA                    :   FCC
 Japan                  :   VCCI
 China                  :   CNAS


The related certificate for our laboratories about the test site and management system can be downloaded
from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm
The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site :
http://www.quietek.com/
If you have any comments, Please don’t hesitate to contact us. Our contact information is as below:

 HsinChu Testing Laboratory :
 No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C.
 TEL:+886-3-592-8858 / FAX:+886-3-592-8859              E-Mail : service@quietek.com

 LinKou Testing Laboratory :
 No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C.
 TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789            E-Mail : service@quietek.com


 Suzhou Testing Laboratory :
 No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China
 TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : service@quietek.com




                                             Page: 3 of 7


                                                    Report No: 1622078R-RF-US-P20V01


History of This Test Report
      REPORT NO.         VERSION               DESCRIPTION           ISSUED DATE


 1622078R-RF-US-P20V01   V1.0        Initial Issued Report          Mar. 04, 2016


 1622078R-RF-US-P20V01   V2.0        Modified model name            Mar. 24, 2016




                                Page: 4 of 7


                                                              Report No: 1622078R-RF-US-P20V01


1. RF Exposure Evaluation

1.1. Limits

    According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate
    the environment impact of human exposure to radio frequency (RF) radiation as specified in
    1.1307(b)
    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                              Electric           Magnetic
                                                                   Power             Average
         Frequency            Field              Field
                                                                   Density           Time
         Range (MHz)          Strength           Strength
                                                                   (mW/cm2)          (Minutes)
                              (V/m)              (A/m)
         (A) Limits for Occupational/ Control Exposures
         300-1500             --                 --                F/300             6
         1500-100,000         --                 --                5                 6
         (B) Limits for General Population/ Uncontrolled Exposures
         300-1500             --                 --                F/1500            6
         1500-100,000         --                 --                1                 30
    F= Frequency in MHz


    Friis Formula
    Friis transmission formula: Pd = (Pout*G)/(4*pi*r2)


    Where
    Pd = power density in mW/cm2
    Pout = output power to antenna in mW
    G = gain of antenna in linear scale
    Pi = 3.1416
    R = distance between observation point and center of the radiator in cm


    Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total
    power input to the antenna, through the calculation, we will know the distance r where the
    MPE limit is reached.




                                          Page: 5 of 7


                                                            Report No: 1622078R-RF-US-P20V01


1.2. Test Procedure

    Software provided by client enabled the EUT to transmit and receive data at lowest, middle
    and highest channel individually.
    The temperature and related humidity: 18℃and 78% RH.


1.3. Test Result of RF Exposure Evaluation

    Product           :   EZ-BLE PROC MODULE
    Test Item         :   RF Exposure Evaluation
    Test Site         :   AC-6


    z     Antenna Gain:
    No.                   Peak Gain
    ANT                   0.5dBi




                                        Page: 6 of 7


                                                          Report No: 1622078R-RF-US-P20V01


RF Exposure Evaluation
z   Output Power into Antenna & RF Exposure Evaluation Distance:
                                                    Maximum Output     Power Density at R =
       Test Mode           Frequency Band (MHz) Power to Antenna              20 cm
                                                          (mW)              (mW/cm2)
        Bluetooth             2402~2480MHz               0.6776             0.000151
Note: The standalone power density Pd (4th column) at a distance of 20 cm calculated from
the Friis transmission formula is below the limit of 1 mW/cm2.