Summary: Standalone MPE Calculations and Summary
                                                                                                                                                                           2               2                           2
     Band (MHZ)               Tx Duty Cycle (%)               Tx Frequeny (MHz)              Power Total (mW)                     Antenna Gain (dBi)         SL (W/m )             S20 (W/m )       RC (cm)     SC (W/m )
       902-928                        100                            917                            28                                    1                    2.771                  0.07            3.2          2.77

       Band (MHZ)                  Tx Duty Cycle (%)          Tx Frequeny (MHz)              Power Total (mW)                     Antenna Gain (dBi)        SL (W/m2)              S20 (W/m2)       RC (cm) SC (W/m2)
       2400-2483.5                       100                         2402                           4                                     5                   5.351                   0.03            1.4      5.35

Simlutaneous MPE Calculation
   Tx Frequeny (MHz)                                   917                     2402
        S20 (W/m2 )                                    0.07                     0.03
       SL (W/m2 )                                 2.771                       5.351
Power Ratio (SL / S20 )                           0.025                       0.005
           Sum of Power Ratios at 20cm (0.025 + 0.005)                        0.030
                        Requirement = Σ of MPE Ratio ≤ 1


                         Model: TDSPC0U3                                          Test Number:                  190530
MPE Calculator           RF Exposure uses EIRP for calculation. EIRP is based on TX power added to the antenna gain in dBi.
                         dBi = dB gain compared to an isotropic radiator.
                         S = power density in mW/cm^2
                   Transmitter maximum Output power operating at 100% (Watts)                0.0280                                       Antenna Gain (dBi)                                                    1
                            Output Power for 100% duty Cycle operation (Watts)               0.0280                                   Antenna Gain (Numeric)                                                  1.26
                                                              Calcualtion power
Tx Frequency (MHz)                                917                                        0.0280                      dBd + 2.17 = dBi         dBi to dBd                                                   2.2
                                                                          (Watts)
                                                                                                                                          Antenna Gain (dBd)                                                  -1.17
Cable Loss (dB)                                    0.0 Adjusted Power (dBm)                    14.47                                Antenna minus cable (dBi)                                                  1.00

                                          Calculated ERP (mw) 21.387                                                                                              EIRP = Po(dBM) + Gain (dB)
                                          Calculated EIRP (mw) 35.250                                                                                                    Radiated (EIRP) dBm    15.472
                                                                                                                                                                           ERP = EIRP - 2.17 dB
                                          EIRP
               Power density (S) mW/cm2 = -------                                                                                                                         Radiated (ERP) dBm    13.302
                                          4 p r^2

                 r (cm) EIRP (mW)


                                       Occupational Limit                          FCC radio frequency radiation exposure limits per 1.1310
                         3.06               mW/cm2                       Frequency (MHz)       Occupational Limit (mW/cm2 )       Public Limit (mW/cm2 )
                        30.57                W/m2                            30-300                                    1                                    0.2
                                       General Public Limit                 300-1,500                               f/300                                 f/1500
                         0.61               mW/cm2                        1,500-10,000                                 5                                     1
                         6.11                   W/m2


                                       Occupational Limit
                  0.6455ƒ0.5                    W/m2                                   IC radio frequency radiation exposure limits per RSS-102
                                                   2
                      24.33                  W/m                         Frequency (MHz)             Occupational Limit (W/m2 )                  Public Limit (W/m2 )
                                                                                                                            0.5
                                       General Public Limit                 100-6,000                        0.6455ƒ
                        0.6834                     2
             0.02619ƒ                           W/m                       6,000-15,000                           50
                         2.77                   W/m2                          48-300                                                                      1.291
                                                                                                                                                                  0.6834
                                                                            300-6,000                                                                  0.02619ƒ
                                                                          6,000-15,000                               50                                     10

f = Transmit Frequecny (MHz)                                                                                                                                  f (MHz) =                           917 MHz
PT = Power Input to Antenna (mW)                                                                                                                             PT (mW) =                             28 mW
Duty cycle (percentage of operation)                                                                                                                                %=                            100 %
PA = Adjusted Power due to Duty cycle or Cable Loss (mW)                                                                                                     PA (mW) =                             28 mW
GN = Numeric Gain of the Antenna                                                                                                                          GN (numeric) =                         1.26 numeric
                                                                                                                              2                                                2
S20 = Power Density of device at 20cm (W/m2 )                                                    S20 =(PAGN)/(4πR20 )                                       S20 (W/m ) =                         0.07 W/m2
SL = Power Density Limit (W/m )2
                                                                                                                                                             SL (W/m2 ) =                       2.771 W/m2
RC = Minimum distance to the Radiating Element for Compliance (cm)                               RC=√(P AGN/4πS )
                                                                                                                L                                                 RC (cm) =                       3.2 cm
                                                                                                                          2                                                    2
SC = Power Density of the device at the Compliance Distance RC (W/m2 )                           SC=(PAGN)/(4πRC)                                            SC (W/m ) =                         2.77 W/m2
R20 = 20cm                                                                                                                                                        R20 =                            20 cm

                                   For Complaince with Canada General Population Limits, User Manual must indicate a minimum seperation distance of                                               3.2 cm


             Rogers Labs, Inc.                                       SAF Tehnika AS               S/N’s: 306681 000005 / 306681 000006
             4405 W. 259th Terrace                                   Model: TDSPC0U3 (Aranet 4)          FCC ID: W9Z-ARANET4
             Louisburg, KS 66053                                     Test: 190530                               IC: 8855A-ARANET4
             Phone/Fax: (913) 837-3214                               Test to: CFR47 15C, RSS-Gen RSS-247        Date: August 28, 2019
             Revision 1                                              File: TDSPC0U3 RFExp                       Page 1 of 2


                       Model: TDSPC0U3                                          Test Number:                  190530
MPE Calculator         RF Exposure uses EIRP for calculation. EIRP is based on TX power added to the antenna gain in dBi.
                       dBi = dB gain compared to an isotropic radiator.
                       S = power density in mW/cm^2
                 Transmitter maximum Output power operating at 100% (Watts)                0.0040                                       Antenna Gain (dBi)                       5
                          Output Power for 100% duty Cycle operation (Watts)               0.0040                                   Antenna Gain (Numeric)                     3.16
                                                            Calcualtion power
Tx Frequency (MHz)                             2402                                        0.0040                      dBd + 2.17 = dBi         dBi to dBd                     2.2
                                                                        (Watts)
                                                                                                                                        Antenna Gain (dBd)                     2.83
Cable Loss (dB)                                  0.0 Adjusted Power (dBm)                    6.02                                 Antenna minus cable (dBi)                    5.00

                                       Calculated ERP (mw) 7.675                                                                              EIRP = Po(dBM) + Gain (dB)
                                       Calculated EIRP (mw) 12.649                                                                                   Radiated (EIRP) dBm    11.021
                                                                                                                                                       ERP = EIRP - 2.17 dB
                                         EIRP
              Power density (S) mW/cm2 = -------                                                                                                      Radiated (ERP) dBm     8.851
                                         4 p r^2

                r (cm) EIRP (mW)


                                   Occupational Limit                          FCC radio frequency radiation exposure limits per 1.1310
                       5.00               mW/cm2                     Frequency (MHz)       Occupational Limit (mW/cm2 )       Public Limit (mW/cm2 )
                                                 2
                      50.00              W/m                                30-300                              1                       0.2
                                   General Public Limit                    300-1,500                         f/300                    f/1500
                       1.00               mW/cm2                         1,500-10,000                           5                        1
                      10.00                W/m2


                                   Occupational Limit
                          0.5                    2
                0.6455ƒ                    W/m                                  IC radio frequency radiation exposure limits per RSS-102
                    39.38                W/m2                        Frequency (MHz)          Occupational Limit (W/m2 )       Public Limit (W/m2 )
                                                                                                                     0.5
                                   General Public Limit                   100-6,000                    0.6455ƒ
             0.02619ƒ0.6834                W/m2                          6,000-15,000                      50
                      5.35                 W/m2                            48-300                                                     1.291
                                                                           300-6,000                                              0.02619ƒ0.6834
                                                                         6,000-15,000                         50                       10

f = Transmit Frequecny (MHz)                                                                                                              f (MHz) =                2402 MHz
PT = Power Input to Antenna (mW)                                                                                                         PT (mW) =               4.0000 mW
Duty cycle (percentage of operation)                                                                                                            %=                   100 %
PA = Adjusted Power due to Duty cycle or Cable Loss (mW)                                                                                 PA (mW) =                  4.00 mW
GN = Numeric Gain of the Antenna                                                                                                      GN (numeric) =                3.16 numeric
                                                                                                                       2                           2
S20 = Power Density of device at 20cm (W/m2 )                                             S20 =(PAGN)/(4πR20 )                             S20 (W/m ) =           0.025 W/m2
SL = Power Density Limit (W/m2 )                                                                                                            SL (W/m2 )=           5.351 W/m2
RC = Minimum distance to the Radiating Element for Compliance (cm)                        RC=√(P AGN/4π S )
                                                                                                         L                                    RC (cm) =             1.4 cm
                                                                                                                   2                               2
SC = Power Density of the device at the Compliance Distance RC (W/m2 )                    SC=(PAGN)/(4πRC)                                 SC (W/m ) =             5.35 W/m2
R20 = 20cm                                                                                                                                       R20=                20 cm

                                For Complaince with Canada General Population Limits, User Manual must indicate a minimum seperation distance of                    1.4 cm




              Rogers Labs, Inc.                                      SAF Tehnika AS               S/N’s: 306681 000005 / 306681 000006
              4405 W. 259th Terrace                                  Model: TDSPC0U3 (Aranet 4)          FCC ID: W9Z-ARANET4
              Louisburg, KS 66053                                    Test: 190530                               IC: 8855A-ARANET4
              Phone/Fax: (913) 837-3214                              Test to: CFR47 15C, RSS-Gen RSS-247        Date: August 28, 2019
              Revision 1                                             File: TDSPC0U3 RFExp                       Page 2 of 2



Document Created: 2019-08-28 07:31:26
Document Modified: 2019-08-28 07:31:26

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC