Test Report_data record

FCC ID: W5388D2935000T

Test Report

Download: PDF
FCCID_4252466

                                            Test Report No.50238183 001




              Appendix D: Radiated and Mains Spurious Emission Data




                                         (File: 50238183 001AppendixD)



Contents
Emissions, Fundamental ................................................................................................................................. 2
Spurious Emissions, TX Mode, 9-150 kHz .................................................................................................... 5
Spurious Emissions, TX Mode, 150 kHz -30MHz ......................................................................................... 6
Spurious Emissions, TX Mode, 30MHz-1GHz .............................................................................................. 7
Spurious Emissions, Mains, 150kHz - 30MHz .............................................................................................. 9


Emissions, Fundamental


                                   TUV Rheinland Taiwan Ltd.
                                   11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105
                                   Tel:+886—2172—7000     fax:+886—2528—0018
     #           ®
TUVRheinland




130.0        dBu¥/m
                                                                   _                                               Limit]:     ———
                                                                   |                                               Margin:     ——




 70




                                                1                                            4




10.0
     13.00       13.12     13.24        13.36           13.48       13.60       13.72        13.84       13.96     14.08     14.20   MHz




Service No.:             238101198NCC                                           Test Distance:            3m
Test Standard:           NCC_13.56M_Fundamental 3m(QP)                          Ant. Polarization:

Test item:               Radiation Emission                                     Test Time:                2019/3/19 11:32:57

Applicant:               HiTi                                                   Test Rating:              AC 110v/60Hz
Product:                 Photo Printer                                          Temp.(°C )/Hum.(%):       19.5(C)/65.6%

Model No.:               P52XXX                                                 Test Engineer:            Curry Chen

Test Mode:               TX+RX 13.56MHz
Remark:                  TX+RX

                         Kigk


No.      Frequency       Factor    Reading           Level             Limit     Margin          Det.   Height   Azimuth       Remark

             (MHz)       (dB/m)     (dBuV)          (dBuV/m)       (dBuV/m)        (dB)                  (cm)      (+)
 1           13.3948     20.83        11.67          32.50             69.50      —37.00         QP      100       273
 2           13.5600     20.85       20.96           41.81             124.00     —82.19         peak    100       269
 3           13.5600     20.85       19.95           40.80             124.00     —83.20         QP      100       269
 4           13.8052     20.88       10.48           31.36             69.50      —38.14         QP      100       240


Spurious Emissions, TX Mode 150 kHz —30MHz


                                    TUV Rheinland Taiwan Ltd.
                                    11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105
                                    Tel:+886—2172—7000     fax:+886—2528—0018
     #           ®
TUVRheinland




130.0        dBu¥/m
                                                                    _                                             Limit]:     ———
                                                                    |                                             Margin:     ——




 70




                                1                                                                         4



10.0
     13.00       13.12     13.24         13.36           13.48       13.60       13.72        13.84     13.96     14.08     14.20    MHz




Service No.:             238101198NCC                                            Test Distance:          3m
Test Standard:           NCC_13.56M_Fundamental 3m(QP)                           Ant. Polarization:
Test item:               Radiation Emission                                      Test Time:              2019/3/19 11:36:27

Applicant:               HiTi                                                    Test Rating:            AC 110v/60Hz
Product:                 Photo Printer                                           Temp.(°C )/Hum.(%):     19.5(C)/65.6%

Model No.:               P52XXX                                                  Test Engineer:          Curry Chen

Test Mode:               TX+RX 13.56MHz
Remark:                  TX+RX

                         BRés


No.      Frequency       Factor     Reading          Level              Limit     Margin        Det.   Height   Azimuth       Remark

             (MHz)       (dB/m)      (dBuV)       (dBuV/m)          (dBuV/m)        (dB)                (cm)      (+)
 1           13.2388     20.82        10.98          31.80              69.50      —37.70       QP      100       302
 2           13.5592     20.85        22.90          43.75              124.00     —80.25       peak    100        98               TX
 3           13.5592     20.85        22.30          43.15              124.00     —80.85       QP      100        98               TX
 4           13.9480     20.90        10.84          31.74              69.50      —37.176      QP      100       191




Spurious Emissions, TX Mode 150 kHz —30MHz


                                   TUV Rheinland Taiwan Ltd.
                                   11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105
                                   Tel:+886—2172—7000     fax:+886—2528—0018
     #           ®
TUVRheinland




140.0        dBu¥/m
                                                                                                                  Limit]:
                                                                                                                  Margin:




 70




 0.0
     13.11       13.20     13.29        13.38           13.47       13.56      13.64      13.73       13.82       13.91     14.00    MHz




Service No.:             238101198NCC                                           Test Distance:           1.2m
Test Standard:           FCC 15.225_Fundamental_1.2m(dBuV/m)                    Ant. Polarization:

Test item:               Radiation Emission                                     Test Time:               2019/3/20 18:58:29

Applicant:               HiTi                                                   Test Rating:             AC 110v/60Hz
Product:                 Photo Printer                                          Temp.(°C )/Hum.(%):      20(CC)/65%

Model No.:               P52XXX                                                 Test Engineer:           Amy Hsu

Test Mode:               TX 13.56MHz
Remark:
                         lg 9K



No.      Frequency       Factor     Reading         Level             Limit     Margin       Det.    Height     Azimuth       Remark

             (MHz)       (dB/m)     (dBuV)       (dBuV/m)          (dBuV/m)       (dB)                (cm)        (+)
 1           13.4286     20.84        11.14         31.98             106.40     —74.42      QP       100         200
 2           13.4874     20.84        11.61         32.45             106.40     —73.95      QP       100         80
 3           13.5345     20.85        16.24         37.09             106.40     —69.31      QP       100         80
 4           13.5595     20.85       26.55          4740              139.90     —92.50      QP       100         97                TX
 5           13.6120     20.86        13.28         34.14             106.40     —72.26      QP       100         80
 6           13.6591     20.86        10.77         31.63             106.40     —74.77      QP       100         305
 7           13.6912     20.87        10.71         31.58             106.40     —74.82      QP       100         64


Spurious Emissions, TX Mode 150 kHz —30MHz


Spurious Emissions, TX Mode, 9—150 kHz
                                   TUV Rheinland Taiwan Ltd.
                                   11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105
                                   Tel:+886—2172—7000   fax:+886—2528—0018
     #           ®
TUVRheinland




130.0        dBu¥/m
                                                                                                               Limit]:     ———
                                                                                                               Margin:     ——




 70




         udMW
            2                                            4A
                                                                                     .                        5

                                                                                     nat ¥utemgee)
10.0
     9.00        23.10     37.20        51.30       65.40         79.50      93.60        107.70    121.80     135.90    150.00   kHz




Service No.:             238101198NCC                                        Test Distance:          3m
Test Standard:           NCC2.8_9k—1G_3m                                     Ant. Polarization:

Test item:               Radiation Emission                                  Test Time:              2019/3/19 11:36:59

Applicant:               HiTi                                                Test Rating:            AC 110v/60Hz
Product:                 Photo Printer                                       Temp.(°C )/Hum.(%):     19.5(°C)Y/65.6%

Model No.:               P52XXX                                              Test Engineer:          Curry Chen

Test Mode:               TX+RX 13.56MHz
Remark:                  TX+RX

                         BRés


No.         Frequency    Factor     Reading         Level           Limit      Margin       Det.   Height    Azimuth       Remark

             (MHz)       (dB/m)     (dBuV)       (dBuV/m)        (dBuV/m)       (dB)                (cm)       (+)
 1           0.0144      18.70       27.82          46.52           124.42     —77.90         QP    100           82
 2           0.0292      19.29       21.21          40.50           118.28     —77.178        QP    100           194
 3           0.0447      19.03        19.78         38.81           114.59     —75.178        QP    100           66
 4           0.0655      18.73       21.56          40.29           111.27     —70.98         QP    100        233
 5           0.0960      18.38        12.71         31.09           107.95     —76.86         QP    100           181
 6           0.1311      18.35        15.80         34.15           105.25     —71.10         QP    100        253
Spurious Emissions, TX Mode 150 kHz —30MHz


Spurious Emissions, TX Mode, 150 kHz —30MHz
                                 TUV Rheinland Taiwan Ltd.
                                 11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105
                                 Tel:+886—2172—7000     fax:+886—2528—0018
     #           ®
TUVRheinland



110.0        dBu¥/m
                                                                                                               Limit]:
                                                                                                               Margin:




     0.15        3.14     6.12        9.11            12.09       15.08      18.06        21.04     24.03      27.02      30.00    MHz




Service No.:            238101198NCC                                         Test Distance:          3m
Test Standard:          NCC2.8_9k—1G_3m                                      Ant. Polarization:

Test item:              Radiation Emission                                   Test Time:              2019/3/19 13:08:43

Applicant:              HiTi                                                 Test Rating:            AC 110v/60Hz
Product:                Photo Printer                                        Temp.(°C )/Hum.(%):     19.5(°C)Y/65.6%

Model No.:              P52XXX                                               Test Engineer:          Curry Chen

Test Mode:              TX+RX 13.56MHz
Remark:                 TX+RX

                        BRés


No.         Frequency   Factor    Reading         Level             Limit      Margin       Det.   Height   Azimuth         Remark

             (MHz)      (dB/m)    (dBuV)       (dBuV/m)          (dBuV/m)       (dB)                (cm)       (+)
 1           0.1799     18.37      36.31          54.68             102.50     —47.82         QP    100        336
 2           4.8961     19.42       12.39         31.81             69.50      —37.69         QP    100        52
 3           9.2244     20.29       11.99         32.28             69.50      —37.22         QP    100        312
 4           13.5600    20.85      20.27          41.12             69.50      —28.38         QP    100        82                 TX
 5           17.7914    21.35       10.97         32.32             69.50      —37.18         QP    100        280
 6           23.1942    21.73       10.43         32.16             69.50      —37.34         QP    100        39
 7           26.0598    21.82       9.26          31.08             69.50      —38 .42        QP    100        200


Spurious Emissions, TX Mode 150 kHz —30MHz


Spurious Emissions, TX Mode, 30MHz—1GHz
                                     TUV Rheinland Taiwan Ltd.
                                     11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105
                                     Tel:+886—2172—7000     fax:+886—2528—0018
     #              ®
TUVRheinland




 80.0        dBu¥/m
                                                                                                                      Limit]:
                                                                                                                      Margin:




 4l]_|—l

                                                                                             :               &
                1                              e                                             HJ bnnpoat— e £., quanat




 0.0
     30.00       127.00     224.00        321.00          418.00      515.00     612.00          709.00    806.00     903.00    —1000.00 MHz




Service No.:              238101198NCC                                           Test Distance:             3m
Test Standard:            NCC Class B 3M Radiation                               Ant. Polarization:         Horizontal
Test item:                Radiation Emission                                     Test Time:                 2019/3/19 11:09:13

Applicant:                HiTi                                                   Test Rating:               AC 110v/60Hz
Product:                  Photo Printer                                          Temp.(°C )/Hum.(%):        19.5(°C)Y/65.6%

Model No.:                P52XXX                                                 Test Engineer:             Curry Chen

Test Mode:                TX+RX 13.56MHz
Remark:                   TX+RX

                          BRés


No.      Frequency        Factor      Reading         Level             Limit      Margin         Det.    Height    Azimuth       Remark

              (MHz)       (dB/m)      (dBuV)       (dBuV/m)          (dBuV/m)       (dB)                   (cm)       (+)
 1           96.9300      —10.04       38.44          28.40             43.50      —15.10          QP      100        115
 2           167.7400     —8.76        42.05          33.29             43.50      —10.21          QP      100           98
 3           324.8800     —4.18        34.33          30.15             46.00      —15.85          QP      100        171
 4           398.6000     —2.37        32.70          30.33             46.00      —15.67          QP      100           66
 5           664.3800      0.99        33.05          34.04             46.00       —11.96         QP      100           95
 6           801.1500      3.12        30.03          33.15             46.00      —12.85          QP      100        154
Spurious Emissions, Mains, 150kHz — 30MHz


                                     TUV Rheinland Taiwan Ltd.
                                     11F., No.758, Sec.4 Bade Road. Songshan Dist, Taipei City 105
                                     Tel:+886—2172—7000     fax:+886—2528—0018
     #            ®
TUVRheinland




 80.0        dBu¥/m
                                                                                                                      Limit]:
                                                                                                                      Margin:




 4l]_|—l

                 1 %                                                4                       y               §
                                                   WWWM


 0.0
     30.00       127.00     224.00        321.00          418.00        515.00     612.00       709.00    806.00      903.00    —1000.00 MHz




Service No.:              238101198NCC                                             Test Distance:          3m
Test Standard:            NCC Class B 3M Radiation                                 Ant. Polarization:      Vertical
Test item:                Radiation Emission                                       Test Time:              2019/3/19 11:10:06

Applicant:                HiTi                                                     Test Rating:            AC 110v/60Hz
Product:                  Photo Printer                                            Temp.(°C )/Hum.(%):     19.5(°C)Y/65.6%

Model No.:                P52XXX                                                   Test Engineer:          Curry Chen

Test Mode:                TX+RX 13.56MHz
Remark:                   TX+RX

                          BRés


No.      Frequency        Factor      Reading         Level              Limit       Margin       Det.   Height    Azimuth        Remark

              (MHz)       (dB/m)      (dBuV)       (dBuV/m)             (dBuV/m)      (dB)                (cm)        (+)
 1           100.8100     —9.35        42.43          33.08              43.50       —10.42         QP    100          6
 2           126.0300     —7.20        41.71          34.51              43.50        —8.99         QP    100         167
 3           352.0400     —3.26        30.96          27.70              46.00       —18.30         QP    100         202
 4           474.2600     —1.59        31.15          29.56              46.00       —16.44         QP    100         186
 5           647.8900      0.79        33.00          33.79              46.00       —12.21         QP    100         81
 6           801.1500      3.12        29.08          32.20              46.00       —13.80         QP    100         88
Spurious Emissions, Mains, 150kHz — 30MHz


Spurious Emissions, Mains, 150kHz - 30MHz




Mains Spurious Emissions




Spurious Emissions, Mains, 150kHz - 30MHz
                                            9


                                  TUY Rhcinland Tebwan Ltd.
                                  1F., No. 798. Se.4 Bade Road. Songshan Dist, Taipei City 105
                                  Tel:+886—2172—7000 Fax:+880—2528—0018

TOViheintand
                    Fie:cietiCReportaotonimaserorroopson)— MiStsstortorpszet)_oooot.ci
            Level (aB                                                 Date: 2010.0.42 time: ooz
      &
      s s
      s s
      8 s
      8




         oas oz          as       1        2                        s       10        2o    30
                                     Frequency tuity
  Trace: 1
Site            : Conduction room
Condition         NCC Class B Conduction(QP) line1
Test Engineen: Joe Tien
Applicant         mits
Product           Photo printer
Model. No.        ps2sl
Test Rating       110Vac/60ftz
Tmp/Hum                : 19.6T/49%
Heno                    Normal operation—Long cable(USB connectsRFID Tagsprint)
                     Read              Limit Over
               Freq Level Factor Level Line: Linit Remark
                me       aow‘   ds    dbw      dow       db
 1            ©.200    35.s3 ces     as.ar    e3.61   —20.40   P
 2            0.200.   28.22 9.68    37.90—   53.61   —15.71   Average
  3           o.2s7    as.es 9.68.   37.76.   et.21   —23.45   0P
 a            ©.257.   19.81 9.68    29.49    S1.21   —21.72   Average
  s           ©.6e0    12.02 9.69.   22.11.   s6.00   —33.09   P
 s            ©.660     5.75 9.69°   15.44.   46.00   —30.56   Average
 7            o.93e    r6.17 9.70.   25.87.   s6.00   —30.13   P
 8            o.930     5.65 9.70.   15.35.   46.00   —30.65   Average
 9           an2as     por 9.83      so.ea    60.00   —20.16   0P
do           i1213     r4.80 9.83    24.63.   50.00   —25.37   Average
q1           2e.aso    rhe7 9.86     31.73.   60.00   28.27    QP
420          20.359    16.02.9.05.   25.88.   50.00   —24.12   Average


                                        TUY Rhcinland Tebwan Ltd.
                                        1F., No. 798. Se.4 Bade Road. Songshan Dist, Taipei City 105
                                        Tel:+886—2172—7000 Fax:+880—2528—0018

TOviheintan
                      Fie:c:etiCReportaotonimaserorroopson)— MiStsstortorpszet)_cm
              Level (aB                                                 Date: 2010.0.12 time:ocziect6
        &
        s s
        s s
        8 s
        8




         oas oz                   as            1           2              s     10        zo     30
                                                      Frequency tuity
  Trace: 1
Site            :        Conduction room
Condition                NCC Class B Conduction(QP) neutral
Test Engineen:           loe Tien
Applicant                mits
Product                  Photo printer
Model. No.               ps2sl
Test Rating              110Vac/60ftz
Tmp/Hum                  19.6¢C/a9%
Meno                     Normal operation—Long cable(US8 connect#RFID Tageprint)
                       Read              Limit Over
                 Freq Level Factor Level Line: Linit Remark
                  me       aow‘        ds    dbw      dow       db
   1            o.202.   ss.ea    ces       a3.32.   63.52   —20.20   P
   2            0.202.   27.98    9.68      37.62.   53.52   —15.90   Average
   3            o.2sr    26.7e    968.      se46.    61.21   —22.75   P
   a            ©.257.   20.60     9.68     30.36.   S1.21   —20.85   Average
   s            o.éea    22273    c.e8.     s2.a1.   s6.00   —23.59   P
   s            ©.603.   11.49    9.68.     21.17.   46.00   —24.83   Average
   7            muasnl   anse     o.        2nl2s    s6.00   —34.77   P
   8            1.a91     0.47    9.71.     10.18    46.00   —35.82   Average
   o            6.300.   15.a8    9.79.     25.27.   60.00   —34.73   P
 10             6.300     8.62.   9.79°     18.41.   50.00   —31.59   Average
 a1            asare     zoi      9.86      30.57.   60.00   —29.43   @P
 1200          as.aro    as.o5    9.86.     24.91.   50.00   —25.09   Average



Document Created: 2019-04-11 19:05:59