User Manual 3

FCC ID: W38CT1H00

Users Manual

Download: PDF
FCCID_1071336

Coulomb CT1000 Wall Mount Smartlet Installation Instructions

              Part Number: 75-001001-01

                      Revision 0.1


Copyright
Copyright© 2008 Coulomb Technologies, Inc. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It
may not be modified, reproduced or distributed without the prior, express written consent
of Coulomb Technologies, Inc.
Safety and Compliance
This manual only covers installation of Coulomb’s Smartlet™ Charging Station and should
not be used for any other product. Before installing the Smartlet Charging Station, you
should review this manual carefully and consult with a licensed contractor, licensed elec-
trician and trained installation expert to ensure compliance with local building practices,
climate conditions, safety standards, and state and local codes.

The Smartlet Charging Station should be installed only by a licensed contractor and a
licensed electrician and in accordance with the U.S. National Electric Code and the
National Fire Protection Association codes and standards. The Smartlet Charging Station
should be inspected by an authorized installer prior to the initial use.
Under no circumstances will compliance with the information in this manual relieve the
user of his/her responsibility for compliance with all applicable codes or safety standards.
No Guarantee as to Accuracy
Reasonable effort was made to ensure that the specifications and other information in this
manual were accurate and complete at the time of its publication. However, the specifica-
tions and other information in this manual are subject to change at any time without prior
notice.
Warranty Information and Disclaimer
Your use of or modification to the Smartlet Charging Station in a manner in which the
Smartlet Charging Station is not intended to be used or modified will void the limited
warranty. Other than any such limited warranty, the Coulomb products are provided “AS
IS,” and Coulomb and its distributors expressly disclaim all implied warranties, including
any warranty of design, merchantability, fitness for a particular purposes and non-
infringement, to the maximum extent permitted by law.
Limitation of Liability
IN NO EVENT SHALL COULOMB TECHNOLOGIES, INC. OR ITS AUTHORIZED DISTRIBUTORS
BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL, PUNITIVE, OR CONSEQUENTIAL
DAMAGES, INCLUDING WITHOUT LIMITATION LOST PROFITS, LOST DATA, LOSS OF USE,
COST OF COVER, OR LOSS OR DAMAGE TO THE SMARTLET CHARGING STATION, ARISING
OUT OF OR RELATING TO THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF COULOMB
TECHNOLOGIES, INC. OR ITS AUTHORIZED DISTRIBUTORS HAVE BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES.
Trademarks
COULOMB TECHNOLOGIES, SMARTLET, and CHARGEPOINT are trademarks or service
marks of Coulomb Technologies, Inc in the U.S. and other countries. All other trademarks
or service marks mentioned in this manual or on the Coulomb Technologies, Inc. website
are the property of their respective owners.




Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1   PRELIMINARY


    Documentation




                                                                               Front Panel




                                                                                    Body




          Ø7.00
          6 PLC           63.50




 139.70




                                               400.00




 139.70




                                                                                                            Wall Mount Bracket


                                  ADA Height 38”



Template for Wall Drill Holes


                                                        Bottom Plate




                                                        Components and Parts:
                                                         Body Installation Kit
                                                           (shipped to installer)




                  Coulomb CT1000 Wall Mount Smartlet Installation Instructions             Revision 0.1   PRELIMINARY


    CT1000 Wall Mount Smartlet Template



                                                                                          2.50"
                                                                                        63.50 mm
                                                Ø 0.28"
                                               7.00 mm
                                                  6 PLC




           5.50"
         139.70 mm
                                        NOT TO SCALE




                                                                                                                                      15.75"
                                                                                                                                    400.00 mm




           5.50"
         139.70 mm




                                                                                             Height to bottom of bracket 38” (965.20mm)
                                                                                                 (USA ADA height is 48” to display)
Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1   PRELIMINARY


                                             Head Module




             Security Screws




Caps for Security Screws




 Required Hardware: (installer supplied)

 Torx Driver T15 Torx 3" Blade Length 7-1/2", Tamper Resistant




                                     Components and Parts:
                                   Head Module Installation Kit




  Coulomb CT1000 Wall Mount Smartlet Installation Instructions    Revision 0.1   PRELIMINARY


                                                                    6 - 1/4" Lag Screw 1-1/2"
                                                                    McMaster P/N: 95526A125

                                                                    6 - Long Lag Screw Anchor
                                                                    McMaster P/N: 97039A029

                                                                    (Installer supplied)




                               Drill Holes for Inserts (6 places)
                                    see supplied template




Coulomb CT1000 Wall Mount Smartlet Installation Instructions    Revision 0.1     PRELIMINARY


                                                                  38” Max height above
                                                               surface for ADA compliance




                               Attach Wall Bracket (6 places)
                            (Installer supplied screws and inserts)




Coulomb CT1000 Wall Mount Smartlet Installation Instructions      Revision 0.1     PRELIMINARY


          Attach Body to Wall Bracket with 4 Supplied Screws and Washers




Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1   PRELIMINARY


              3/4” coupling
           (Installer supplied)


           Attach installer supplied coupler to the wall mounted body and connect conduit.




                                    Connect Conduit




Coulomb CT1000 Wall Mount Smartlet Installation Instructions    Revision 0.1     PRELIMINARY


                                                                                White

                                                                                Black

                                                                                Green




                                              Strip wires back 3/8".
                                              SOLID WIRES ONLY.




                               Feed Wire Through Conduit




Coulomb CT1000 Wall Mount Smartlet Installation Instructions     Revision 0.1    PRELIMINARY


                                                                    Use these 3 screws




                            White Black Green
                           Neutral Hot Ground
                                120VAC Input
        Requires 15A branch circuit and overcurrent protection on supply




                                 Wire Connection Label




Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1    PRELIMINARY


                                                                                     Green

                                                                                     Black

                                                                                     White




                   View after wires are connected and screwed in place.




                                      Connect Wire




Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1   PRELIMINARY


                                                                       Torx Driver T15 Torx
                                                                       3" Blade Length
                                                                       7-1/2", Tamper-Resistant




                                   Attach Bottom Plate




Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1    PRELIMINARY


                                                     1. Slide front panel into place.




                                                               2. Tighten set screws with included alan wrench,
                                                                 in two places.




                                                                         Inside view with panel in place.




                                 Slide Front Panel into Place




Coulomb CT1000 Wall Mount Smartlet Installation Instructions      Revision 0.1     PRELIMINARY


         Connect the attached cable from the head module with the connectors in the body.




                               Slide Head Module into Place




Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1     PRELIMINARY


  Torx Driver T15 Torx
    3" Blade Length
7-1/2", Tamper-Resistant




                                Secure Head Module (4 screws)




   Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1   PRELIMINARY


                                                                                Max height for
                                                                                 ADA is 48”




                             Secure Cover Plugs for 4 Screws




Coulomb CT1000 Wall Mount Smartlet Installation Instructions   Revision 0.1   PRELIMINARY


Note: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.

Caution: Changes or modifications not expressly approved by the party responsible for compliance
         could void the user's authority to operate the equipment.



Document Created: 2009-02-20 17:44:45