BT BLE RF test report FCC ID W38-28010077

FCC ID: W38-28010161

Test Report

Download: PDF
FCCID_4181215

RF TEST
REPORT

Report No.: FCC_RF_SL15060501-CPC-006-DTS
Supersede Report No.: None

Applicant                             :   ChargePoint, Inc.
Product Name                          :   Network Communication
Model No.                             :   28010077
                                          47 CFR 15.247
Test Standard                         :
                                          RSS 210 Issue8: 2010
                                          ANSI C63.10: 2013
Test Method                           :   RSS Gen issue4
                                          558074 D01 DTS Meas Guidance v03r02
FCC ID                              : W38-28010077
IC ID                               : 8854A-28010077
Dates of test                       : June 24, 2015 to July 20, 2015
Issue Date                          : July 23, 2015
Test Result                         : ☒ Pass            ☐ Fail
Equipment complied with the specification [X]
Equipment did not comply with the specification    [ ]




This Test Report is Issued Under the Authority of:




                  Teody Manansala                                              Nima Molaei
                    Test Engineer                                            Engineer Reviewer


                                                   Issued By:
                                              SIEMIC Laboratories
                                   775 Montague Expressway, Milpitas, 95035 CA




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                      Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                      Page              2 of 33




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
          Country/Region                 Accreditation Body                                      Scope
                USA                           FCC, A2LA                               EMC, RF/Wireless, Telecom
             Canada                        IC, A2LA, NIST                             EMC, RF/Wireless, Telecom
              Taiwan                      BSMI, NCC, NIST                              EMC, RF, Telecom, Safety
            Hong Kong                        OFTA, NIST                                   RF/Wireless, Telecom
             Australia                       NATA, NIST                                EMC, RF, Telecom, Safety
              Korea                        KCC/RRA, NIST                            EMI, EMS, RF, Telecom, Safety
              Japan                    VCCI, JATE, TELEC, RFT                          EMI, RF/Wireless, Telecom
              Mexico                   NOM, COFETEL, Caniety                       Safety, EMC, RF/Wireless, Telecom
              Europe                          A2LA, NIST                               EMC, RF, Telecom, Safety
               Israel                         MOC, NIST                                EMC, RF, Telecom, Safety

                                    Accreditations for Product Certifications
              Country                      Accreditation Body                                   Scope
                USA                          FCC TCB, NIST                                 EMC, RF, Telecom
              Canada                          IC FCB, NIST                                 EMC, RF, Telecom
             Singapore                          iDA, NIST                                  EMC, RF, Telecom
                EU                                 NB                                    EMC & R&TTE Directive
               Japan                         MIC (RCB 208)                                   RF, Telecom
             Hong Kong                       OFTA (US002)                                    RF, Telecom



          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                              Test report No.         FCC_RF_SL15060501-CPC-006-DTS
                                                                                              Page                    3 of 33




CONTENTS
1       REPORT REVISION HISTORY .......................................................................................................................................4
2       EXECUTIVE SUMMARY.................................................................................................................................................5
3       CUSTOMER INFORMATION ..........................................................................................................................................5
4       TEST SITE INFORMATION ............................................................................................................................................5
5       MODIFICATION .............................................................................................................................................................5
6       EUT INFORMATION ......................................................................................................................................................6
     6.1     EUT Description ........................................................................................................................................................6
     Radio Description ...............................................................................................................................................................6
     Spec for BT Radio ..............................................................................................................................................................6
     6.2     EUT test modes/configuration Description....................................................................................................................6
     6.3     EUT Photos ..............................................................................................................................................................7
     6.4     EUT Test Setup Photos .............................................................................................................................................9
7       SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION ....................................................................... 10
     7.1     Supporting Equipment ............................................................................................................................................. 10
     7.2     Cabling Description ................................................................................................................................................. 10
     7.3     Test Software Description ........................................................................................................................................ 10
8       TEST SUMMARY ......................................................................................................................................................... 11
9       MEASUREMENT UNCERTAINTY ................................................................................................................................. 12
10           MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................................. 13
     10.1        Conducted Emissions .......................................................................................................................................... 13
     10.2        Output Power (Bluetooth LE) ................................................................................................................................ 16
     10.3        Band Edge (Bluetooth LE) ................................................................................................................................... 18
     10.4        99% Occupied Bandwidth (Bluetooth LE) .............................................................................................................. 20
     10.5        6dB Bandwidth (Bluetooth LE) .............................................................................................................................. 22
     10.6        Peak Spectral Density (Bluetooth LE) ................................................................................................................... 24
     10.7        Transmitter Radiated Spurious Emissions Below 1GHz .......................................................................................... 26
     10.8        Transmitter Radiated Spurious Emissions > 1GHz & Restricted band....................................................................... 28
ANNEX A. TEST INSTRUMENT ........................................................................................................................................... 31
ANNEX B. SIEMIC ACCREDITATION ................................................................................................................................... 32




              775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                            Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                              Page              4 of 33




1   Report Revision History
           Report No.                           Report Version                   Description             Issue Date
FCC_RF_SL15060501-CPC-006-DTS                       None                           Original              07/23/2015




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                          Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.    FCC_RF_SL15060501-CPC-006-DTS
                                                                Page               5 of 33




2    Executive Summary

The purpose of this test program was to demonstrate compliance of following product
 Company:       ChargePoint, Inc.
 Product:       Network Comunication
 Model:         28010077

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with
the Stipulated Standard listed on 1st page.


3    Customer information
 Applicant Name               :   ChargePoint, Inc.
 Applicant Address            :   254 E. Hacienda Ave Campbell, CA 95148
 Manufacturer Name            :   ChargePoint, Inc.
 Manufacturer Address         :   254 E. Hacienda Ave Campbell, CA 95148



4    Test site information

 Lab performing tests                   SIEMIC Laboratories
 Lab Address                            775 Montague Expressway, Milpitas, CA 95035
 FCC Test Site No.                      881796
 IC Test Site No.                       4842D-2
 VCCI Test Site No.                     A0133


5    Modification
                Index                           Item                              Description                  Note
                  -                               -                                    -                           -




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.     FCC_RF_SL15060501-CPC-006-DTS
                                                                Page                6 of 33




6     EUT Information
6.1    EUT Description

Product Name                                   Network Comunication
Model No.                                      28010077
Trade Name                                     ChargePoint, Inc.
Serial No.                                     N/A
Host Model No.                                 N/A
Input Power                                    100-240VDC, 50/60Hz
Power Adapter Manu/Model                       Condor/HK-CH13-A05
Power Adapter SN                               N/A
Product Hardware version                       27-010077
Product Software version                       4.0.0.41
Radio Hardware version                         27-010077
Radio Software version                         4.0.0.41
Test Software version                          4.0.0.41
Date of EUT received                           June 20, 2015
Equipment Class/ Category                      DTS
Operating Frequencies                          2402MHz-2480MHz
Port/Connectors                                N/A

Radio Description

Spec for BT Radio
            Radio Type                                                   Bluetooth (Ver4.0+EDR)
        Operating Frequency                                              2402MHz-2480MHz
            Modulation                                               FHSS (BDR, EDR), DSSS (LE)
          Channel Spacing                                            1MHz (BDR, EDR), 2MHz (LE)
           Antenna Type                                               Prestta Embedded Antenna
           Antenna Gain                                                     2.5dBi (2.4GHz)
      Antenna Connector Type                                                   On Board

Channel List
               Type                    Channel No.                    Frequency (MHz)                    Available (Y/N)
                                            0                              2402                                Y
                                           …                                …                                  Y
         Bluetooth LE                      19                              2440                                Y
                                           …                                …                                  Y
                                           39                              2480                                Y

6.2    EUT test modes/configuration Description

              Mode                                                                   Note
           Bluetooth LE                                                           LE (GFSK)




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                               Page              7 of 33




6.3   EUT Photos




                    EUT Top View                                                      EUT Bottom View




                  PCBA2 –Top View                                                     PCBA2 –Top View




              Power Supply – Top View                                            Power Supply – Bottom View


       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                        Page              8 of 33




       EUT Radio with shielding                                           EUT Radio without shielding




               Antenna 1                                                          Antenna 2




775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                    Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                               Page              9 of 33




6.4   EUT Test Setup Photos




      AC Line Conducted Emissions – Front View                          AC Line Conducted Emissions – Rear View




       Radiated Emissions (<1GHz) – Front View                            Radiated Emissions (<1GHz) – Rear View




       Radiated Emissions (>1GHz) – Front View                            Radiated Emissions (>1GHz) – Rear View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                                    Test report No.    FCC_RF_SL15060501-CPC-006-DTS
                                                                    Page               10 of 33




7     Supporting Equipment/Software and cabling Description
7.1        Supporting Equipment

               Supporting Equipment
    Item                                           Model                     Serial Number          Manufacturer          Note
                   Description
      1               Laptop              P05F Latitude E5510                    N/A                      Dell              -




7.2        Cabling Description

                              Connection Start                   Connection Stop               Length / shielding Info
           Name                                                                                                              Note
                            From          I/O Port             To            I/O Port         Length (m)      Shielding
           USB              EUT           I/O Port           Laptop            USB                1          Unshielded         -



7.3        Test Software Description

      Test Item                        Software                                             Description
      RF Testing                       Tera Term                      Set the EUT to transmit continuously in diferent test mode




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                              Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                              Page              11 of 33




8       Test Summary

            Test Item                        Test standard                              Test Method/Procedure                          Pass / Fail
                                                                                               ANSI C63.10: 2013                      ☒ Pass
 Restricted Band of Operation        FCC              15.205           FCC
                                                                                      558074 D01 DTS Meas Guidance v03r02             ☐ N/A
     AC Conducted Emissions                                                                                                           ☒ Pass
                                     FCC             15.207(a)         FCC                      ANSI C63.10: 2013
            Voltage                                                                                                                   ☐ N/A

DTS band Requirement
            Test Item                        Test standard                              Test Method/Procedure                          Pass / Fail
                                      FCC          15.247 (a)(1)       FCC                               -                            ☐ Pass
        Channel Separation
                                       IC         RSS210 (A8.1)          IC                              -                            ☒ N/A
                                                                                                                                      ☒ Pass
     99% Occupied Bandwidth            IC         RSS210(A8.1)           IC                       RSS Gen (6.6)
                                                                                                                                      ☐ N/A
                                      FCC          15.247(a)(2)        FCC           558074 D01 DTS Meas Guidance v03r02              ☒ Pass
           6db Bandwidth
                                       IC         RSS210 (A8.2)          IC                              -                            ☐ N/A
                                      FCC          15.247(a)(1)        FCC                               -                            ☐ Pass
Number of Hopping Channels
                                       IC         RSS210(A8.1)           IC                          -                                ☒ N/A
                                                                                              ANSI C63.10: 2013
     Band Edge and Radiated           FCC           15.247(d)          FCC                                                            ☒ Pass
                                                                                     558074 D01 DTS Meas Guidance v03r02
       Spurious Emissions                                                                                                             ☐ N/A
                                       IC         RSS210(A8.5)           IC                          -
                                      FCC          15.247(a)(1)        FCC                               -                            ☐ Pass
        Time of Occupancy
                                       IC         RSS210(A8.1)           IC                              -                            ☒ N/A
                                      FCC           15.247(b)          FCC           558074 D01 DTS Meas Guidance v03r02              ☒ Pass
           Output Power
                                       IC         RSS210 (A8.4)          IC                              -                            ☐ N/A
                                                                                                                                      ☐ Pass
 Receiver Spurious Emissions           IC         RSS Gen (7.1)          IC                       RSS Gen (7.1)
                                                                                                                                      ☒ N/A
                                      FCC           15.247(e)          FCC                               -                            ☐ Pass
       Antenna Gain > 6 dBi
                                       IC         RSS210(A8.4)           IC                              -                            ☒ N/A
                                      FCC            15.247(e)            FCC           558074 D01 DTS Meas Guidance v03r02           ☒ Pass
      Power Spectral Density
                                       IC         RSS210(A8.3)              IC                           -                            ☐ N/A
                                      FCC             15.247(f)           FCC                            -                            ☐ Pass
    Hybrid System Requirement
                                       IC         RSS210(A8.3)              IC                           -                            ☒ N/A
                                      FCC            15.247(g)            FCC                            -                            ☐ Pass
        Hopping Capability
                                       IC         RSS210(A8.1)              IC                           -                            ☒ N/A
      Hopping Coordination            FCC            15.247(h)            FCC                            -                            ☐ Pass
           Requirement                 IC         RSS210(A8.1)              IC                           -                            ☒ N/A
                                      FCC             15.247(i)           FCC                            -                            ☐ Pass
     RF Exposure requirement
                                       IC          RSS Gen(3.2)             IC                          -                             ☒ N/A
                    1. All measurement uncertainties do not take into consideration for all presented test results.
    Remark          2. The applicant shall ensure frequency stability by showing that an emission is maintained within the band of operation under
                           all normal operating conditions as specified in the user’s manual.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                  Page              12 of 33




9    Measurement Uncertainty

                                                          Emissions

               Test Item                    Frequency Range                           Description                        Uncertainty
                                                                    Confidence level of approximately 95% (in the case
                                                                                                                          +5.6dB/-
Band Edge and Radiated Spurious Emissions     30MHz – 1GHz           where distributions are normal), with a coverage
                                                                                                                           4.5dB
                                                                       factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m)
                                                                    Confidence level of approximately 95% (in the case
                                                                                                                          +4.3dB/-
Band Edge and Radiated Spurious Emissions     1GHz – 40GHz           where distributions are normal), with a coverage
                                                                                                                           4.1dB
                                                                       factor of 2 (for EUTs < 0.5m X 0.5m X 0.5m)




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                                        Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                        Page              13 of 33




10 Measurements, Examination and Derived Results
10.1 Conducted Emissions
Conducted Emission Limit

               Frequency ranges                                                           Limit (dBuV)
                    (MHz)                                              QP                                        Average
                   0.15 ~ 0.5                                        66 – 56                                     56 – 46
                     0.5 ~ 5                                           56                                          46
                     5 ~ 30                                            60                                          50

 Spec                Item       Requirement                                                                               Applicable
                                For Low-power radio-frequency devices that is designed to be connected to the
                                public utility (AC) power line, the radio frequency voltage that is conducted back onto
                                the AC power line on any frequency or frequencies, within the band 150 kHz to 30
 47CFR§ 15.207       a)                                                                                                        ☒
                                MHz, shall not exceed the limits in the following table, as measured using a 50 µ H/50
                                ohms line impedance stabilization network (LISN). The lower limit applies at the
                                boundary between the frequency ranges.




   Test Setup




                            -    The EUT and supporting equipment were set up in accordance with the requirements of the standard on
                                 top of a 1.5m x 1m x 0.8m high, non-metallic table, as shown in Annex B.
   Procedure                -    The power supply for the EUT was fed through a 50/50H EUT LISN, connected to filtered mains.
                            -    The RF OUT of the EUT LISN was connected to the EMI test receiver via a low-loss coaxial cable.
                            -    All other supporting equipment was powered separately from another main supply.

     Remark          EUT tested with AC 110V 60Hz

     Result          ☒ Pass               ☐ Fail



Test Data      ☒ Yes                          ☐ N/A
Test Plot      ☒ Yes (See below)              ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                   Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                     Page              14 of 33




Conducted Emission Test Results (Live)

Test specification:                      Conducted Emissions
                                         Temp(° C):                            22
Environmental Conditions:                Humidity (%):                         40
                                                                                                                        ☒ Pass
                                         Atmospheric(mbar):                    1022
                                                                                                     Result:
Mains Power:                             110Vac, 60Hz
                                                                                                                        ☐ Fail
Tested by:                               Teody Manansala
Test Date:                               07/20/2015
Remarks                                  Line




                                                       Line Plot at 120Vac, 60Hz


 Frequency             Raw       Cable       Factors       Level    Measurement                   Limit        Margin      Pass
                                                                                         Line
   (MHz)              (dBuV)   Loss (dB)      (dB)        (dBuV)       Type                      (dBuV)         (dB)       /Fail
     0.16             49.21      10.00         0.75       59.96       Quasi Peak         Live     65.70         -5.73      Pass
     0.20             38.38      10.00         0.74       49.13       Quasi Peak         Live     63.50        -14.37      Pass
     0.26             35.13      10.00         0.72       45.85       Quasi Peak         Live     61.35        -15.50      Pass
     0.40             21.24      10.01         0.73       31.97       Quasi Peak         Live     57.76        -25.79      Pass
     2.42             20.32      10.03         0.96       31.30       Quasi Peak         Live     56.00        -24.70      Pass
     0.48             21.13      10.01         0.74       31.88       Quasi Peak         Live     56.27        -24.39      Pass
     0.16             30.68      10.00         0.75       41.44        Average           Live     55.70        -14.26      Pass
     0.20             18.69      10.00         0.74       29.43        Average           Live     53.50        -24.06      Pass
     0.26             18.14      10.00         0.72       28.86        Average           Live     51.35        -22.49      Pass
     0.40             11.19      10.01         0.73       21.92        Average           Live     47.76        -25.84      Pass
     2.42             11.90      10.03         0.96       22.89        Average           Live     46.00        -23.11      Pass
     0.48             11.38      10.01         0.74       22.12        Average           Live     46.27        -24.15      Pass

Note: The results above show only the worst case.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                    Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                    Page              15 of 33




Conducted Emission Test Results (Neutral)

Test specification:                      Conducted Emissions
                                         Temp(° C):                           22
Environmental Conditions:                Humidity (%):                        40
                                                                                                                        ☒ Pass
                                         Atmospheric(mbar):                   1022
                                                                                                     Result:
Mains Power:                             110Vac, 60Hz
                                                                                                                        ☐ Fail
Tested by:                               Teody Manansala
Test Date:                               07/20/2015
Remarks                                  Neutral




                                                   Neutral Line Plot @ 120Vac, 60Hz


 Frequency             Raw       Cable       Factors      Level     Measurement                   Limit        Margin      Pass
                                                                                        Line
   (MHz)              (dBuV)   Loss (dB)      (dB)       (dBuV)        Type                      (dBuV)         (dB)       /Fail
     0.15             46.64      10.00         0.76       57.39      Quasi Peak        Neutral   65.77          -8.38      Pass
     0.21             39.09      10.00         0.74       49.83      Quasi Peak        Neutral   63.20         -13.37      Pass
     0.26             32.79      10.00         0.72       43.51      Quasi Peak        Neutral   61.47         -17.96      Pass
     2.38             21.17      10.03         0.96       32.16      Quasi Peak        Neutral   56.00         -23.84      Pass
     3.16             23.09      10.03         0.99       34.11      Quasi Peak        Neutral   56.00         -21.89      Pass
     3.20             18.31      10.03         1.00       29.33      Quasi Peak        Neutral   56.00         -26.67      Pass
     0.15             27.55      10.00         0.76       38.31       Average          Neutral   55.77         -17.46      Pass
     0.21             24.60      10.00         0.74       35.34       Average          Neutral   53.20         -17.86      Pass
     0.26             14.53      10.00         0.72       25.26        Average         Neutral   51.47         -26.22      Pass
     2.38             12.16      10.03         0.96       23.14        Average         Neutral   46.00         -22.86      Pass
     3.16             13.16      10.03         0.99       24.18        Average         Neutral   46.00         -21.82      Pass
     3.20             10.31      10.03         1.00       21.34        Average         Neutral   46.00         -24.66      Pass

Note: The results above show only the worst case.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                      Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                      Page              16 of 33




10.2 Output Power (Bluetooth LE)
Requirement(s):

 Spec                  Item    Requirement                                                                              Applicable
                       a)      FHSS in 2400-2483.5MHz with ≥ 75 channels: ≤1 Watt                                             ☐
                       b)      FHSS in 5725-5850MHz: ≤1 Watt                                                                  ☐
                       c)      For all other FHSS in the 2400-2483.5MHz band: ≤0.125 Watt.                                    ☐
     § 15.247
                       d)      FHSS in 902-928MHz with ≥ 50 channels: ≤1 Watt                                                 ☐
                       e)      FHSS in 902-928MHz with ≥ 25 & <50 channels: ≤0.25 Watt                                        ☐
                       f)      DSSS in 902-928MHz, 2400-2483.5MHz, 5725-5850MHz: ≤1 Watt                                      ☒




    Test Setup




                       Measurement using a Power Meter (PM)

                       Measurements may be performed using a wideband gated RF power meter provided that the gate parameters
                       are adjusted such that the power is measured only when the EUT is transmitting at its maximum power control
                       level. Since the measurement is made only during the ON time of the transmitter, no duty cycle correction factor
  Test Procedure       is required.
                             - Connect EUT’s RF output power to power meter
                             - Set EUT to be continuous transmission mode
                             - Measurement the average output power using power meter and record the result
                             - Repeat above steps for different test channel and other modulation type.
                                                                                      Temperature                     23ºC
                                                                  Environmental
     Test Date         07/02/2015                                                     Relative Humidity               44%
                                                                     condition
                                                                                      Atmospheric Pressure            1021mbar

        Remark         -


        Result         ☒ Pass             ☐ Fail



Test Data      ☒ Yes                       ☐ N/A
Test Plot      ☐ Yes (See below)           ☒ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                               Page              17 of 33



Output Power measurement result (Bluetooth)
                                                                                                    Limit
           Type                 Test mode         Freq (MHz)        CH            Conducted                      Result
                                                                                                   (dBm)
                                                                                 Power (dBm)
       Output power            Bluetooth LE          2402          Low               1.9            30           Pass
       Output power            Bluetooth LE          2440          Mid               1.6            30           Pass
       Output power            Bluetooth LE          2480          High              1.2            30           Pass




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                                         Test report No.     FCC_RF_SL15060501-CPC-006-DTS
                                                                         Page                18 of 33




10.3 Band Edge (Bluetooth LE)
Requirement(s):

 Spec                  Item        Requirement                                                                            Applicable
                                   For non-restricted band, In any 100 kHz bandwidth outside the frequency band in
                                   which the spread spectrum or digitally modulated intentional radiator is operating,
                                   the radio frequency power that is produced by the intentional radiator shall be at
                                   least 20 dB or 30dB below that in the 100 kHz bandwidth within the band that
     § 15.247          d)                                                                                                       ☒
                                   contains the highest level of the desired power, determined by the measurement
                                   method on output power to be used. Attenuation below the general limits specified
                                   in § 15.209 (a) is not required
                                    ☐ 20 dB down          ☒ 30 dB down




    Test Setup




                       558074 D01 DTS Meas Guidance v03r02

                       Band Edge measurement procedure

                              1.    Set the EUT to maximum power setting and enable the EUT transmit continuously.
  Test Procedure
                              2.    Band edge emissions must be at least 30 dB down from the highest emission level within the
                                    authorized band as a measured. The attunation shall be be 30 dB instead of 20 dB when RMS
                                    conducted output power procedure is used.
                              3.    Change modulation and channel bandwidth then repeat step 1 to 2.
                              4.    Measured and record the results in the test report.

                                                                                              Temperature                 22ºC
                                                                        Environmental
     Test Date         07/02/2015                                                             Relative Humidity           46%
                                                                          condition
                                                                                              Atmospheric Pressure        1020mbar

        Remark         -

        Result         ☒ Pass                ☐ Fail



Equipment Setting

        TEST                  RBW                VBW               SPAN               Detector       SWEEP            Trace     NOTES

    Band Edge               100KHz            ≥3 x RBW       135 MHz / 55 MHz              Peak       Auto           Peak MAX          -



Test Data      ☐ Yes                           ☒ N/A
Test Plot      ☒ Yes (See below)               ☐ N/A



            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                   Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                Page              19 of 33



Band Edge Test Plots (Bluetooth LE)




                   Band Edge-LE Low                                                   Band Edge-LE High




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                       Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                       Page              20 of 33




10.4 99% Occupied Bandwidth (Bluetooth LE)

Requirement(s):
Spec                Requirement                                                                                            Applicable
                    The transmitter shall be operated at its maximum carrier power measured under normal test
                    conditions. The span of the analyzer shall be set to capture all products of the modulation process,
                    including the emission skirts. The resolution bandwidth shall be set to as close to 1% of the
                    selected span as is possible without being below 1%. The video bandwidth shall be set to 3 times
                    the resolution bandwidth. Video averaging is not permitted. Where practical, a sampling detector
RSS Gen 4.6.1       shall be used given that a peak or peak hold may produce a wider bandwidth than actual. The                 ☒
                    trace data points are recovered and directly summed in linear terms. The recovered amplitude
                    data points, beginning at the lowest frequency, are placed in a running sum until 0.5% of the total
                    is reached and that frequency recorded. The process is repeated for the highest frequency data
                    points. This frequency is recorded. The span between the two recorded frequencies is the
                    occupied bandwidth




  Test Setup




                         1.   EUT was set for low , mid, high channel with modulated mode and highest RF output power.
  Procedure
                         2.   The spectrum analyzer was connected to the antenna terminal.
                                                                                               Temperature                   23oC
   Test Date        07/02/2015                                  Environmental condition        Relative Humidity             47%
                                                                                               Atmospheric Pressure          1019mbar

    Remark          -


    Result          ☒ Pass             ☐ Fail

Test Data      ☒ Yes (See below)              ☐ N/A
Test Plot      ☒ Yes (See below)            ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.    FCC_RF_SL15060501-CPC-006-DTS
                                                                Page               21 of 33



99%dB Bandwidth measurement result for Bluetooth LE
        Type          Test mode         Freq (MHz)             CH             Result (MHz)     Limit (MHz)    Result

       99% BW            BT-LE              2402              Low                  1.0941         N/A              N/A
       99% BW            BT-LE              2440              Mid                  1.0947         N/A              N/A
       99% BW            BT-LE              2480              High                 1.0948         N/A              N/A


99%dB Bandwidth Test Plot (Bluetooth LE)




            99% BW –Bluetooth LE 2402MHz                                          99% BW –Bluetooth LE 2440MHz




           99% BW –Bluetooth LE 2480MHz




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


       ’fl
                                                                               Test report No.   FCC_RF_SL15060501—CPC—006—DTS
 SIEMIC                                                                        Page              22 of 33
 GLOBAL TESTING & CERTIFICATIONS
 Your choice ron—rce rce ca o can rce



10.5      6dB Bandwidth (Bluetooth LE

Requirement(s):

        Spec              Item        Requirement                                                                                 Applicable
    §15.247               a)(2) 60B BW>500KHz;



   Test Setup                   9:..] ————
                                      Spectrum
                                      Analyzer

                        558074 D01 DTS Meas Guidance v03r02, 8.1 DTS bandwidth

                        6dB Emission bandwidth measurement procedure
                                 —      Set RBW = 100 kHz.
                                 —      Set the video bandwidth (VBW) > 3x RBW.
 Test Procedure                  —      Detector = Peak.
                                 —      Trace mode= max hold.
                                 —      Sweep= auto couple.
                                 —      Allow the frace to stabilize.
                                 —      Measure the maximum width of the emission that is constrained by the frequencies associated with the
                                        two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
                                        maximum leve! measured in the fundamental emission.
                                                                                    ;            Temperature                    249C
    Test Date           071022015                                                Eofoicy©. Relative Humidity                      42%
                                                                                                   Atmospheric Pressure          1021mbar

     Remark               N/A


       Result                Pass                C Fail



Equipment Setting

        TEST                         RBW             VBW          SPAN          Detector          SWEEP               Trace             NOTES

       60B DTS
       Bandwidth
                                     100KHz         3x RBW        ~EBW              PK              Auto             Max hold             —

Test Data           Yes                 C NA

Test Plot           Yes                 C NA




            775 Montague Expressway, Milpitas, CA 95035, USA + Phone: (+1) 408 526 1188 * Facsimile (+1) 408 526 1088

                                         Visit us at: www.siemic.com; Follow us at: n


                                                                Test report No.    FCC_RF_SL15060501-CPC-006-DTS
                                                                Page               23 of 33



6dB Bandwidth measurement result for Bluetooth LE
         Type         Test mode           Freq (MHz)           CH             Result (MHz)     Limit (MHz)    Result
       6dB BW         Bluetooth LE          2402              Low                  0.601          ≥0.5           Pass
       6dB BW         Bluetooth LE          2440              Mid                  0.601          ≥0.5           Pass
       6dB BW         Bluetooth LE          2480              High                 0.604          ≥0.5           Pass


6dB Bandwidth Test Plots( Bluetooth LE)




            6dB BW –Bluetooth LE 2402MHz                                          6dB BW –Bluetooth LE 2440MHz




            6dB BW –Bluetooth LE 2480MHz




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


      ’fl
                                                                             Test report No.       FCC_RF_SL15060501—CPC—006—DTS
 SIEMIC                                                                      Page                  24 of 33
 GLOBAL TESTING & CERTIFICATIONS
 Your choice ron—rce rce ca o can rce



10.6 Peak Spectral Density (Bluetooth LE)

Requirement(s):

 Spec                      Item_|       Requirement                                                                             Applicable
                           €)           DSSS: <8dBm/3KHz
     §15.247(e)                              —    —      —                   —
                           1            DSSS in hybrid sys with FH turned off. <8dBm/3KHz                                       C




     Test Setup                         Es} ————(sx)
                                        Spectrum
                                                 C


                                        Analyzer

                           558074 DO1 DTS Meas Guidance v03r02, 10.3 Method AVGPSD—1

                           Peak spectral density measurement procedure
                               —    Setanalyzer center frequency to DTS channel center frequency.
                                    —    Set the span to 1.5 times the DTS bandwidth.
                                    —    Set the RBW to: 3 kHz = RBW = 100 kHz.
  Test Procedure                    —    Setthe VBW > 3x RBW,
                                    —    Detector= RMS
                                    —    Sweep time= auto couple.
                                    —    Trace mode = Trace average over 100 traces
                                    —    Allow trace to fully stabllize.
                                    —    Use the peak marker function to determine the maximum amplitude leve! within the RBW.
                                    —    If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.
                                                                             Environmental          Temperature                 22C
      Test Date            0710212015                                            condition          Relative Humidity           46%
                                                                                                    Atmospheric Pressure        1020mbar

        Remark             —


        Result                  Pass             C Fall



Equipment Setting


        TEST                        RBW               VBW             SPAN               Detector          SWEEP           Trace       NOTES

         PSD                    100KHz            >3x RBW         1.6x DTS BW                RMS            Auto            Trace
                                                                                                                           average
                                                                                                                                             —


Test Data          Yes                          C N/A
Test Plot           Yes (See below)             C NA




            775 Montague Expressway, Milpitas, CA 95035, USA + Phone: (+1) 408 526 1188 * Facsimile (+1) 408 526 1088

                                        Visit us at: www.siemic.com; Follow us at: n


                                                                  Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                  Page              25 of 33



PSD measurement result (Bluetooth LE)
                                          Freq                     Conducted PSD              Limit
   Type             Test mode                         CH                                                        Result
                                         (MHz)                      (dBm/100KHz)           (dBm/3KHz)

   PSD              Bluetooth LE         2402         Low                  5.558               ≤8               Pass
   PSD              Bluetooth LE         2440         Mid                  5.298               ≤8               Pass
   PSD              Bluetooth LE         2480         High                 4.805               ≤8               Pass



Test Plots (Bluetooth LE)




                  PSD -Bluetooth LE Low                                               PSD -Bluetooth LE Mid




                  PSD -Bluetooth LE High




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                                       Test report No.     FCC_RF_SL15060501-CPC-006-DTS
                                                                       Page                26 of 33



10.7 Transmitter Radiated Spurious Emissions Below 1GHz
Requirement(s):

 Spec                   Item   Requirement                                                                                Applicable
                               Except higher limit as specified elsewhere in other section, the emissions from the
                               low-power radio-frequency devices shall not exceed the field strength levels
                               specified in the following table and the level of any unwanted emissions shall not
                               exceed the level of the fundamental emission. The tighter limit applies at the band
 47CFR§ 15.247(d),             edges                                                                                            ☒
                         a)
   RSS210(A8.5)                          Frequency range (MHz)                           Field Strength (uV/m)
                                                 30 – 88                                          100
                                                88 – 216                                          150
                                                216 960                                           200
                                               Above 960                                          500




    Test Setup




                        1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                        2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                  Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                  polarization, and adjusting the antenna height in the following manner:
                                  a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
    Procedure                                rotation of the EUT) was chosen.
                                  b.         The EUT was then rotated to the direction that gave the maximum emission.
                                  c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                        3.        A Quasi-peak measurement was then made for that frequency point.
                        4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                  measured.
                        The EUT was scanned up to 1GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                        show only the worst case.
        Result          ☒ Pass            ☐ Fail


Test Data      ☒ Yes (See below)            ☐ N/A

Test Plot      ☒ Yes (See below)            ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                     Page              27 of 33




 Radiated Emission Test Results (Below 1GHz)

 Test specification:                   Radiated Spurious Emissions (30MHz – 1000MHz)
                                       Temp(° C):               20
 Environmental Conditions:             Humidity (%):            36
                                                                                                                        ☒ Pass
                                       Atmospheric(mbar):       1021
                                                                                                         Result:
 Mains Power:                          120VAC, 60Hz
                                                                                                                        ☐ Fail
 Tested by:                            Teody Manansala
 Test Date:                            06/26/2015
 Remarks:                              Bluetooth LE 2440MHz




                                                    Quasi Max Measurement

                         Cable
Frequency        Raw                 AF        Level      Measurement          Pol      Hgt      Azt          Limit    Margin    Pass
                         Loss
  (MHz)         (dBuV)              (dB)     (dBuV/m)        Type             (V/H)    (cm)     (Deg)       (dBuV/m)    (dB)     /Fail
                          (dB)
  48.00         59.14     1.12     -28.46      31.80        Quasi Max           V      104.00   327.00        40.00     -8.2     Pass
  36.00         53.05     1.04     -22.51      31.57        Quasi Max           V      110.00   304.00        40.00    -8.43     Pass
  71.96         57.42     1.48     -30.04      28.86        Quasi Max           V      112.00   31.00         40.00    -11.14    Pass
  40.98         45.07     1.07     -25.63      20.52        Quasi Max           V      133.00   350.00        40.00    -19.48    Pass
  38.90         42.64     1.06     -24.94      18.77        Quasi Max           V      136.00   356.00        40.00    -21.23    Pass
  37.93         40.87     1.05     -24.09      17.83        Quasi Max           V      133.00   54.00         40.00    -22.17    Pass
  48.00         59.14     1.12     -28.46      31.80        Quasi Max           V      104.00   327.00        40.00     -8.2     Pass




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                           Test report No.    FCC_RF_SL15060501-CPC-006-DTS
                                                                           Page               28 of 33




  10.8 Transmitter Radiated Spurious Emissions > 1GHz & Restricted band
  Requirement(s):
Spec                        Item          Requirement                                                                           Applicable
                                          For non-restricted band, In any 100 kHz bandwidth outside the frequency band in
                                          which the spread spectrum or digitally modulated intentional radiator is operating,
                                          the radio frequency power that is produced by the intentional radiator shall be at
                                          least 20 dB or 30dB below that in the 100 kHz bandwidth within the band that                 ☒
                                 a)
                                          contains the highest level of the desired power, determined by the measurement
  47CFR§ 15.247(d),                       method on output power to be used. Attenuation below the general limits
    RSS210(A8.5)                          specified in § 15.209(a) is not required
                                           ☐ 20 dB down           ☒ 30 dB down
                                          or restricted band, emission must also comply with the radiated emission limits
                                 b)                                                                                                    ☒
                                          specified in 15.209




       Test Setup




                            1.            The EUT was switched on and allowed to warm up to its normal operating condition.
                            2.            The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                          Maximization of the emissions, was carried out by rotating the EUT, changing the antenna polarization,
                                          and adjusting the antenna height in the following manner:
                                          a.        Vertical or horizontal polarisation (whichever gave the higher emission level over a full
       Procedure                                    rotation of the EUT) was chosen.
                                          b.        The EUT was then rotated to the direction that gave the maximum emission.
                                          c.        Finally, the antenna height was adjusted to the height that gave the maximum emission.
                            3.            An average measurement was then made for that frequency point.
                            4.            Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                          measured.

                            The EUT was scanned up to 40GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                            show only the worst case.

         Result             ☒ Pass                ☐ Fail

  Equipment Setting
        TEST                 RBW               VBW               SPAN              Detector       SWEEP             Trace           NOTES
  Radiated Spurious                                                                                                                  PK
                             1MHz              3MHz         1GHz - 25 GHz           Peak            Auto          Max hold
      Emission                                                                                                                   Measurement
  Radiated Spurious                                                                                                                  Ave
                             1MHz              10Hz         1GHz - 25 GHz           Peak            Auto          Max hold
      Emission                                                                                                                   Measurement

  Test Data       ☒ Yes (See below)              ☐ N/A

  Test Plot       ☐ Yes (See below)             ☒ N/A



              775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                      Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.     FCC_RF_SL15060501-CPC-006-DTS
                                                                     Page                29 of 33




  Test specification:                   Radiated Spurious Emissions (above 1GHz)
                                        Temp(° C):               20
  Environmental Conditions:             Humidity (%):            36
                                                                                                                         ☒ Pass
                                        Atmospheric(mbar):       1021
                                                                                                         Result:
  Mains Power:                          120VA, 60Hz
                                                                                                                         ☐ Fail
  Tested by:                            Teody Manansala
  Test Date:                            06/30/2015
  Remarks:                              Bluetooth LE

  Bluetooth LE – 2402MHz
                        Cable
Frequency      Raw                AF        Level       Measurement         Pol          Hgt     Azt         Limit    Margin      Pass
                        Loss
  (MHz)       (dBuV)             (dB)     (dBuV/m)         Type            (V/H)        (cm)    (Deg)      (dBuV/m)    (dB)       /Fail
                        (dB)
 4135.93      40.37      5.95   11.63      57.95          Peak Max            H        177.00   350.00      74.00     -16.05      Pass
 2071.91      42.90      3.61   11.25      57.76          Peak Max            V        167.00   304.00      74.00     -16.24      Pass
 1018.22      44.75      2.45    9.65      56.85          Peak Max            V        233.00   248.00      74.00     -17.15      Pass
14781.67      42.02     13.60    7.67      63.29          Peak Max            V        199.00   208.00      74.00     -10.71      Pass
 4135.93      27.05      5.95   11.63      44.63        Average Max           H        177.00   350.00      54.00     -9.37       Pass
 2071.91      30.14      3.61   11.25      45.00        Average Max           V        167.00   304.00      54.00     -9.00       Pass
 1018.22      31.80      2.45    9.65      43.90        Average Max           V        233.00   248.00      54.00     -10.10      Pass
14781.67      29.41     13.60    7.67      50.68        Average Max           V        199.00   208.00      54.00     -3.32       Pass

  Bluetooth LE – 2440MHz
                        Cable
Frequency     Raw                 AF       Level       Measurement         Pol                    Azt        Limit    Margin      Pass
                        Loss                                                       Hgt (cm)
  (MHz)      (dBuV)              (dB)    (dBuV/m)         Type            (V/H)                  (Deg)     (dBuV/m)    (dB)       /Fail
                        (dB)
 4153.69      39.45      5.96   11.56      56.96         Peak Max             V        196.00   235.00       74.00    -17.04      Pass
 1032.87      44.61      2.46   9.62       56.69         Peak Max             V        119.00   93.00        74.00    -17.31      Pass
17711.47      39.76     13.00   10.62      63.38         Peak Max             V        204.00   219.00       74.00    -10.62      Pass
14558.92      42.18     13.21   8.26       63.64         Peak Max             H        186.00   165.00       74.00    -10.36      Pass
 4153.69      26.73      5.96   11.56      44.24       Average Max            V        196.00   235.00       54.00    -9.76       Pass
 1032.87      31.59      2.46   9.62       43.68       Average Max            V        119.00   93.00        54.00    -10.32      Pass
17711.47      27.16     13.00   10.62      50.78       Average Max            V        204.00   219.00       54.00    -3.22       Pass
14558.92      29.36     13.21   8.26       50.82       Average Max            H        186.00   165.00       54.00    -3.18       Pass

  Bluetooth LE – 2480MHz
                        Cable
Frequency     Raw                AF        Level       Measurement         Pol                    Azt        Limit    Margin      Pass
                        Loss                                                       Hgt (cm)
  (MHz)      (dBuV)             (dB)     (dBuV/m)         Type            (V/H)                  (Deg)     (dBuV/m)    (dB)       /Fail
                        (dB)
1049.50      43.77      2.47    9.60       55.84         Peak Max             V        260.00   283.00       74.00    -18.16      Pass
17726.39     40.15      13.00   10.63      63.78         Peak Max             V        263.00   288.00       74.00    -10.22      Pass
2175.31      41.86      4.00    10.93      56.79         Peak Max             H        276.00   276.00       74.00    -17.21      Pass
4050.79      40.12      5.87    12.00      58.00         Peak Max             H        105.00   113.00       74.00    -16.00      Pass
1049.50      31.38      2.47    9.60       43.45       Average Max            V        260.00   283.00       54.00    -10.55      Pass
17726.39     27.23      13.00   10.63      50.86       Average Max            V        263.00   288.00       54.00     -3.14      Pass
2175.31      29.09      4.00    10.93      44.02       Average Max            H        276.00   276.00       54.00     -9.98      Pass
4050.79      26.56      5.87    12.00      44.44       Average Max            H        105.00   113.00       54.00     -9.56      Pass


            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                                                    Test report No.             FCC_RF_SL15060501-CPC-006-DTS
                                                                                                    Page                        30 of 33



 Restricted Band Test plot (Bluetooth BDR/EDR)
                        Marker 2 [T2]               RBW     1 MHz       RF Att     0 dB                                    Marker 2 [T2]               RBW       1 MHz      RF Att     0 dB
       Ref Lvl                  54.09 dB  V/m      VBW     1 MHz                                          Ref Lvl                   47.26 dB  V/m    VBW       1 MHz

        77 dB*                2.40000000 GHz        SWT     5 ms        Unit      dB  V/m                  77 dB*                 2.49332064 GHz      SWT       5 ms       Unit      dB  V/m
  77                                                                                                  77
                                                               2 [T2]      54.09 dB  V/m                                                                          2 [T2]      47.26 dB  V/m
        Peak                        LIMIT CHECK     : PASSED                                  A             Peak                         LIMIT CHECK    : PASSED                                 A
                                                                         2.40000000 GHz                                                                                      2.49332064 GHz
  70                                                           1 [T1]      58.88 dB  V/m             70                                                           1 [T1]      52.65 dB  V/m
                                                                         2.40000000 GHz                                                                                      2.48350000 GHz


                                                                                          1
  60                                                                                                  60

                                                                                          2
                                                                                              IN1                                                                                                IN1
        Average                                                                                         1 Average
        1MAX                                                                                  1MA           1MAX                                                                                 1MA
        2MAX                                                                                  2AV           2MAX                                                                                 2AV
  50                                                                                                  50                                                     2




  40                                                                                                  40
                                                                                              TDS                                                                                                TDS




  30                                                                                                  30




  20                                                                                                  20




  10                                                                                                  10
                                 Vasona Emission Software : EMiSoft                                                                   Vasona Emission Software : EMiSoft
   7                                                                                                   7
       Start 2.39 GHz                      1 MHz/                          Stop 2.4 GHz                    Start 2.4835 GHz                    1.65 MHz/                       Stop 2.5 GHz

Date:          1.JAN.1997   02:20:50                                                                Date:          1.JAN.1997    02:26:43




                            Restricted Band Low BDR                                                                              Restricted Band High BDR




                  775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                                 Visit us at: www.siemic.com; Follow us at:


                                                                   Test report No.      FCC_RF_SL15060501-CPC-006-DTS
                                                                   Page                 31 of 33




Annex A. TEST INSTRUMENT


         Instrument                        Model               Serial #              Cal Date   Cal Cycle    Cal Due     In use

    Conducted Emissions
        R & S Receiver                     ESIB 40             100179           05/26/2015        1 Year    05/26/2016
  V-LISN (150 kHz – 30 MHz)              NNLK 8129            8129-190          08/11/2014        1 Year    08/11/2015
    LISN (9 kHz – 30 MHz)                 MN2050B               1018            07/31/2014        1 Year    07/31/2015
     Radiated Emissions
        R & S Receiver                      ESL6               100178           05/27/2015        1 Year    05/27/2016
 Bi-Log antenna (30MHz~2GHz)                 JB1              A030702           08/11/2014        1 Year    08/11/2015
   Horn Antenna (1-26.5GHz)                 3115              10SL0059          08/11/2014        1 Year    08/11/2015
   Horn Antenna (18-40 GHz)                AH-840              101013           02/19/2015        1 Year    02/19/2016
   Pre-Amplifier (1-26.5GHz)               8449B            3008A00715          02/19/2015        1 Year    02/19/2016
 Microwave Preamplifier (18-40
                                           PA-840              181251           08/11/2014        1 Year    08/11/2015
            GHz)
        3 Meters SAC                         3M                  N/A            08/29/2014        1 Year    08/29/2015
        10 Meters SAC                       10M                  N/A            09/05/2014        1 Year    09/05/2015
 RF Conducted Measurement
      Spectrum Analyzer                    N9010A           MY50210206          08/13/2014        1 Year    08/13/2015
         Power Meter                      7002-006            10SL0189           4/30/2015        1 Year    4/30/2016




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                 Page              32 of 33




Annex B. SIEMIC Accreditation

        Accreditations         Document                                        Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio & Telecommunications Terminal Equipment:
                                           EN45001 – EN ISO/IEC 17025
EU NB
                                           Electromagnetic Compatibility:
                                           EN45001 – EN ISO/IEC 17025

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.   FCC_RF_SL15060501-CPC-006-DTS
                                                                 Page              33 of 33




                                           Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMI
                                           EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measurement

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radio communications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                           S043.2




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2019-03-27 11:26:25
Document Modified: 2019-03-27 11:26:25

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC