Test Report

FCC ID: W38-28010087

Test Report

Download: PDF
FCCID_2771169

RF TEST
REPORT

Report No.: RF_SL15081001-CPC-008-FCC-IC_RFID
Supersede Report No.: None
  Applicant              : ChargePoint, Inc.
  Product Name           : RFID Reader
  Model No.              : 28010087
                           FCC 15.225 2014
  Test Standard        :
                           RSS-210 Issue 8: 2010
                           FCC 15.225 2014
  Test Method          : ANSI C63.10 2013
                           RSS Gen Issue 4 2014
  FCC ID               : W38-28010087
  IC ID                : 8854A-28010087
  Dates of test        : August 24th, 28th, September 18th, and 23rd of 2015
  Issue Date           : 9/24/2015
  Test Result          : ☒ Pass              ☐ Fail
  Equipment complied with the specification            [X ]
  Equipment did not comply with the specification      [ ]




  This Test Report is Issued Under the Authority of:




                    Osvaldo Casorla                                                    Chen Ge
                     Test Engineer                                                Engineer Reviewer
                                      This test report may be reproduced in full only
                      Test result presented in this test report is applicable to the tested sample only




                                                 Issued By:
                                            SIEMIC Laboratories
                                 775 Montague Expressway, Milpitas, CA 95035




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                               Page                2 of 29




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                   Scope
                 USA                            FCC, A2LA                             EMC, RF/Wireless, Telecom
              Canada                         IC, A2LA, NIST                           EMC, RF/Wireless, Telecom
               Taiwan                       BSMI, NCC, NIST                            EMC, RF, Telecom, Safety
             Hong Kong                         OFTA, NIST                                RF/Wireless, Telecom
              Australia                        NATA, NIST                              EMC, RF, Telecom, Safety
               Korea                         KCC/RRA, NIST                           EMI, EMS, RF, Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                        EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                      EMC, RF/Wireless, Telecom, Safety
               Europe                           A2LA, NIST                             EMC, RF, Telecom, Safety
                Israel                          MOC, NIST                              EMC, RF, Telecom, Safety


                                    Accreditations for Product Certifications
               Country                      Accreditation Body                                   Scope
                 USA                          FCC TCB, NIST                                 EMC, RF, Telecom
               Canada                          IC FCB, NIST                                 EMC, RF, Telecom
              Singapore                          iDA, NIST                                  EMC, RF, Telecom
                 EU                                 NB                                    EMC & R&TTE Directive
                Japan                         MIC (RCB 208)                                   RF, Telecom
              Hong Kong                       OFTA (US002)                                    RF, Telecom




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                    Test report No.           RF_SL15081001-CPC-008-FCC-IC_RFID
                                                                                    Page                      3 of 29




CONTENTS
1      REPORT REVISION HISTORY .......................................................................................................................................4
2      EXECUTIVE SUMMARY.................................................................................................................................................5
3      CUSTOMER INFORMATION ..........................................................................................................................................5
4      TEST SITE INFORMATION ............................................................................................................................................5
5      MODIFICATION .............................................................................................................................................................5
6      EUT INFORMATION ......................................................................................................................................................6
     6.1    EUT Description ........................................................................................................................................................6
     6.2    Radio Description ......................................................................................................................................................6
     6.3    EUT test modes/configuration Description....................................................................................................................7
     6.4    EUT Photos – External ..............................................................................................................................................8
     6.5    EUT Test Setup Photos .............................................................................................................................................9
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION ....................................................................... 10
     7.1    Supporting Equipment ............................................................................................................................................. 10
     7.2    Cabling Description ................................................................................................................................................. 10
     7.3    Test Software Description ........................................................................................................................................ 10
8      TEST SUMMARY ......................................................................................................................................................... 11
9      MEASUREMENT UNCERTAINTY ................................................................................................................................. 12
10          MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................................. 13
     10.1       Antenna Requirement.......................................................................................................................................... 13
     10.2       Conducted Emissions Test Result ........................................................................................................................ 14
     10.3       Radiated Measurements ...................................................................................................................................... 17
       10.3.1       Radiated Measurements below 1GHz ............................................................................................................... 17
       10.3.2       Radiated Measurements below 30MHz ............................................................................................................. 19
       10.3.3       Frequency Stability ......................................................................................................................................... 23
       10.3.4       Occupied bandwidth ....................................................................................................................................... 25
ANNEX A. TEST INSTRUMENT ........................................................................................................................................... 27
ANNEX B. SIEMIC ACCREDITATION ................................................................................................................................... 28




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                          Visit us at: www.siemic.com; Follow us at:


                                                       Test report No.   RF_SL15081001-CPC-008-FCC-IC_RFID
                                                       Page              4 of 29




1   Report Revision History
                  Report No.                                Report            Description              Issue Date
      RF_SL15081001-CPC-008-FCC-IC_RFID                     Version
                                                               -               Original                 9/24/2015




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                          Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                            Page                5 of 29




2    Executive Summary

The purpose of this test program was to demonstrate compliance of following product
 Company:         ChargePoint, Inc.
 Product:         RFID Reader
 Model:           28010087

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with the
Stipulated Standard listed on 1st page.



3    Customer information

Applicant Name                         :   ChargePoint, Inc.
Applicant Address                      :   254 E. Hacienda Ave Campbell, CA 95148
Manufacturer Name                      :   ChargePoint, Inc.
Manufacturer Address                   :   254 E. Hacienda Ave Campbell, CA 95148



4    Test site information

Lab performing tests                   :   SIEMIC Laboratories
Lab Address                            :   775 Montague Expressway, Milpitas, CA 95035
FCC Test Site No.                      :   881796
IC Test Site No.                       :   4842D-2
VCCI Test Site No.                     :   A0133



5    Modification

    Index                       Item                                          Description                             Note
      -                           -                                                -                                   -




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.   RF_SL15081001-CPC-008-FCC-IC_RFID
                                                            Page              6 of 29




6      EUT Information

6.1      EUT Description

Product Name                       RFID Reader
Model No.                          28010087
Trade Name                         ChargePoint, Inc.
Serial Number                      Prototype 1
Input Power                        100-240VDC, 50/60Hz
Product Hardware version           28-010087
Product Software version           4.0.1.100
Radio Hardware version             28-010087
Radio Software version             4.0.1.100
Date of EUT received               08/21/2015
Equipment Class/ Category          DTS
Operating Frequencies              13.56MHz
Port/Connectors                    N/A


6.2      Radio Description

Specifications for Radio:
            Radio Type             RFID
       Operating Frequency         13.56MHz
            Modulation             ASK
         Channel Spacing           None
           Antenna Type            PCB loop antenna
           Antenna Gain            0.5dBi
      Antenna Connector Type       N/A

Channel List:
            Type                      Mode                Channel No.           Frequency (MHz)           Available (Y/N)
            RFID                    13.56MHz                  1                      13.56                      Y




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.   RF_SL15081001-CPC-008-FCC-IC_RFID
                                                              Page              7 of 29




6.3    EUT test modes/configuration Description

                  Mode                                                               Note
                 RF test                      EUT is set to continuously transmit at 13.56MHz when powered on.
Note: None


                  Test Item                              Operating mode              Tested antenna port         Test frequencies

             Antenna Requirement                                N/A                           -

        Conducted Emissions Voltage                    Continuous Transmit                    -

   Limit in the band of 13.553 – 13.567 MHz            Continuous Transmit                    -

 Limit in the band of 13.410 – 13.553 MHz and
                                                       Continuous Transmit                    -
              13.567 – 13.710 MHz
                                                                                                                    13.56MHz
 Limit in the band of 13.110 – 13.410 MHz and
                                                       Continuous Transmit                    -
              13.710 – 14.010 MHz

Limit outside the band of 13.110 – 14.010 MHz          Continuous Transmit                    -

              Frequency Stability                      Continuous Transmit                    -

             Occupied Bandwidth                        Continuous Transmit                    -

Note: EUT uses a PCB trace antenna attached to the PCB board. Only radiated measurements were performed during the test.




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.   RF_SL15081001-CPC-008-FCC-IC_RFID
                                                        Page              8 of 29




6.4   EUT Photos – External




                  PCBA1 RFID - View 1                                              PCBA1 RFID - View 2




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.   RF_SL15081001-CPC-008-FCC-IC_RFID
                                                        Page              9 of 29




6.5   EUT Test Setup Photos




        AC Line Conducted Emissions– Front View                           AC Line Conducted Emissions– Rear View




        Radiated Emissions (<1GHz) – Front View                           Radiated Emissions (<1GHz) – Rear View




        Radiated Emissions (<30MHz) – Front View                          Radiated Emissions (<30MHz) – Rear View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.    RF_SL15081001-CPC-008-FCC-IC_RFID
                                                             Page               10 of 29




7       Supporting Equipment/Software and cabling Description

7.1       Supporting Equipment

Index            Supporting Equipment                   Model                  Serial No                  Manu                Note
                     Description
    1                   Laptop                   P05F Latitude E5510             N/A                       Dell                    -


7.2       Cabling Description

                       Connection Start                  Connection Stop                 Length / shielding Info
    Name                                                                                                                    Note
                    From          I/O Port              To           I/O Port          Length (m)      Shielding
    USB             EUT            I/O Port           Laptop           USB                 2           Unshielded              -



7.3       Test Software Description

             Test Item                     Software                                        Description
        Conducted Emissions
Radiated Spurious Emissions                                         Set the EUT to transmit continuously in different test mode.
                                          Tera Term                 Command used which turns on 13.56MHz TX continuously
         Frequency Stability
        Occupied Bandwidth




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                         Test report No.       RF_SL15081001-CPC-008-FCC-IC_RFID
                                                                         Page                  11 of 29




8    Test Summary

              Test Item                                  Test standard                            Test Method/Procedure                     Pass / Fail

                                              FCC                15.203                              ANSI C63.10 – 2013                    ☒ Pass
         Antenna Requirement
                                              IC                                            558074 D01 DTS Meas. Guidance v03r02           ☐ N/A
                                              FCC               15.225(a)                            ANSI C63.10 2013                      ☒ Pass
    AC Conducted Emissions Voltage
                                              IC            RSS Gen (7.2.2)                            RSS Gen. 8.8                        ☐ N/A



              Test Item                                  Test standard                            Test Method/Procedure                     Pass / Fail
                                              FCC               15.225(a)              FCC               ANSI C63.10 2013                  ☒ Pass
Limit in the band of 13.553 – 13.567 MHz
                                              IC              RSS210(A2.6)             IC                  RSS Gen 6.13                    ☐ N/A
Limit in the band of 13.410 – 13.553 MHz      FCC               15.225(b)              FCC               ANSI C63.10 2013                  ☒ Pass
         and 13.567 – 13.710 MHz              IC              RSS210(A2.6)             IC                 RSS Gen 6.13                     ☐ N/A
Limit in the band of 13.110 – 13.410 MHz      FCC               15.225(c)              FCC               ANSI C63.10 2013                  ☒ Pass
         and 13.710 – 14.010 MHz              IC              RSS210(A2.6)             IC                  RSS Gen 6.13                    ☐ N/A
        Limit outside the band of             FCC           15.225(d), 15.209          FCC               ANSI C63.10 2013                  ☒ Pass
         13.110 – 14.010 MHz                  IC              RSS210(A2.6)             IC                  RSS Gen 6.13                    ☐ N/A
                                                                                                                                           ☐ Pass
      Receiver Spurious Emission              IC                     -                 IC                  RSS Gen 7.1
                                                                                                                                           ☒ N/A
                                              FCC               15.225(e)              FCC                        -                        ☒ Pass
          Frequency Stability
                                              IC              RSS210(A2.6)             IC                  RSS Gen 6.11                    ☐ N/A
                                              FCC                     -              FCC                          -                       ☒ Pass
          Occupied Bandwidth
                                              IC              RSS-210(5.9.1)         IC                     RSS Gen 6.6                   ☐ N/A
                                                    1.     All measurement uncertainties are not taken into consideration for all presented test result.
                                                    2.     The applicant shall ensure frequency stability by showing that an emission is maintained
                Remark                                     within the band of operation under all normal operating conditions as specified in the user’s
                                                           manual.
                                                    3.     Test Method: ANSI C63.10: 2013 / RSS – Gen Issue 4: November 2014.




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.    RF_SL15081001-CPC-008-FCC-IC_RFID
                                                          Page               12 of 29




9   Measurement Uncertainty

                      Test Item                                       Description                     Uncertainty
                                                        Confidence level of approximately 95%
          AC Conducted Emissions Voltage                 (in the case where distributions are           ±3.5dB
                                                         normal), with a coverage factor of 2
       Limit in the band of 13.553 – 13.567 MHz                                                      +5.6dB/-4.5dB

     Limit in the band of 13.410 – 13.553 MHz and
                                                                                                     +5.6dB/-4.5dB
                  13.567 – 13.710 MHz
                                                        Confidence level of approximately 95%
     Limit in the band of 13.110 – 13.410 MHz and         (in the case where distributions are
                                                        normal), with a coverage factor of 2 (for    +5.6dB/-4.5dB
                  13.710 – 14.010 MHz
                                                             EUTs < 0.5m X 0.5m X 0.5m)
               Limit outside the band of
                                                                                                     +5.6dB/-4.5dB
                13.110 – 14.010 MHz
            Radiated Spurious Emissions                                                              +5.6dB/-4.5dB




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.    RF_SL15081001-CPC-008-FCC-IC_RFID
                                                               Page               13 of 29




10 Measurements, examination and derived results

10.1 Antenna Requirement

 Specification(s)   Requirement                                                                                        Applicable
                    An intentional radiator shall be designed to ensure that no antenna other than that furnished
                    by the responsible party shall be used with the device.

                    Antenna requirement must meet at least one of the following:
    §15.203                                                                                                               ☒
                    a) Antenna must be permanently attached to the device.
                    b) The antenna must use a unique type of connector to attach to the device.
                    c) Device must be professionally installed. The installer shall be responsible for ensuring that
                       the correct antenna is employed by the device.

                    The RFID antenna is integral to the PCB board permanently to the device which meets the requirement (See
    Remark
                    Internal Photographs submitted as another Exhibit).

     Result         ☒ Pass            ☐ Fail




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                                 Page                14 of 29




10.2 Conducted Emissions Test Result
                                                        Conducted Emission Limit

                                      Frequency ranges                               Limit (dBuV)
                     Section
                                           (MHz)                          QP                        Average
                                           0.15 ~ 0.5                   66 – 56                     56 – 46
                     Class B
                                            0.5 ~ 5                       56                          46
                     devices
                                             5 ~ 30                       60                          50

Specification(s)     Item      Requirement                                                                               Applicable
                               For an intentional radiator that is designed to be connected to the public utility (AC)
                               power line, the radio frequency voltage that is conducted back onto the AC power line
  § 15.207,                    on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed
                      a)       the limits set in § 15.207, as measured using a 50 μH/50 ohms line impedance                 ☒
RSS210(A8.1)
                               stabilization network (LISN).
                               AC Line conducted emission within the band 150kHz to 30MHz




  Test Setup




                           -    The EUT and supporting equipment were set up in accordance with the requirements of the standard on
                                top of a 1.5m x 1m x 0.8m high, non-metallic table, as shown in Annex B.
  Procedure                -    The power supply for the EUT was fed through a 50/50H EUT LISN, connected to filtered mains.
                           -    The RF OUT of the EUT LISN was connected to the EMI test receiver via a low-loss coaxial cable.
                           -    All other supporting equipment was powered separately from another main supply.
                                                                                             Temperature                 22°C
  Test Date         09/23/2015                            Environmental conditions           Relative Humidity           36 %
                                                                                             Atmospheric Pressure        1026 mbar
   Remark           The EUT was tested at 208VAC, 60Hz

    Result          ☒ Pass              ☐ Fail

Test Data      ☒ Yes (See below)               ☐ N/A
Test Plot      ☒ Yes (See below)               ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                            Page                15 of 29




Test specification:                  Conducted Emissions
                                     Temp(°C):                                20.1°C
Environmental Conditions:            Humidity (%):                            36%
                                                                                                                      ☒ Pass
                                     Atmospheric(mbar):                       1026mbar
                                                                                                     Result:
Mains Power:                         208VAC, 60Hz
                                                                                                                      ☐ Fail
Tested by:                           Osvaldo Casorla
Test Date:                           09/23/2015
Remarks:                             LMA 13.56MHz RFID TX

                                               Neutral Plot at V=208VAC, ƒ=60Hz




                                                     Neutral Measurements

      Frequency        Raw        Cable    Factors     Level     Measurement        Line/    Limit     Margin
                                                                                                                 Pass /Fail
         MHz           dBuV       Loss       dB        dBuV         Type           Neutral   dBuV       dB
          0.18         40.17      10.00      1.50      51.67       Quasi Peak      Neutral   64.68      -13.01      Pass
          0.23         36.89      10.00      1.16      48.05       Quasi Peak      Neutral   62.47      -14.42      Pass
          0.27         37.58      10.00      0.99      48.58       Quasi Peak      Neutral   61.07      -12.50      Pass
          0.45         32.19      10.01      0.71      42.91       Quasi Peak      Neutral   56.85      -13.94      Pass
          0.48         32.79      10.01      0.69      43.49       Quasi Peak      Neutral   56.29      -12.80      Pass
          3.58         24.58      10.03      0.55      35.17       Quasi Peak      Neutral   56.00      -20.83      Pass
          4.37         28.53      10.03      0.55      39.11       Quasi Peak      Neutral   56.00      -16.89      Pass
          4.75         26.31      10.04      0.55      36.89       Quasi Peak      Neutral   56.00      -19.11      Pass
          0.18         32.62      10.00      1.50      44.12        Average        Neutral   54.68      -10.56      Pass
          0.23         26.17      10.00      1.16      37.33        Average        Neutral   52.47      -15.14      Pass
          0.27         23.46      10.00      0.99      34.46        Average        Neutral   51.07      -16.62      Pass
          0.45         23.69      10.01      0.71      34.41        Average        Neutral   46.85      -12.44      Pass
          0.48         23.46      10.01      0.69      34.16        Average        Neutral   46.29      -12.13      Pass
          3.58         18.10      10.03      0.55      28.68        Average        Neutral   46.00      -17.32      Pass
          4.37         20.20      10.03      0.55      30.78        Average        Neutral   46.00      -15.22      Pass
          4.75         18.86      10.04      0.55      29.45        Average        Neutral   46.00      -16.55      Pass



          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                            Page                16 of 29




Test specification:                  Conducted Emissions
                                     Temp(°C):                                20.1°C
Environmental Conditions:            Humidity (%):                            36%
                                                                                                                      ☒ Pass
                                     Atmospheric(mbar):                       1026mbar
                                                                                                     Result:
Mains Power:                         208VAC, 60Hz
                                                                                                                      ☐ Fail
Tested by:                           Osvaldo Casorla
Test Date:                           09/23/2015
Remarks:                             LMA 13.56MHz RFID TX

                                                Line Plot at V=208VAC, ƒ=60Hz




                                                      Line Measurements

      Frequency        Raw        Cable    Factors     Level     Measurement        Line/    Limit     Margin
                                                                                                                 Pass /Fail
         MHz          dBµV        Loss       dB        dBµV         Type           Neutral   dBµV       dB
          0.18         42.89      10.00      1.49      54.38       Quasi Peak       Line     64.60      -10.23      Pass
          0.22         39.16      10.00      1.19      50.36       Quasi Peak       Line     62.73      -12.37      Pass
          0.27         36.56      10.00      0.99      47.55       Quasi Peak       Line     61.02      -13.47      Pass
          0.27         38.66      10.00      0.98      49.65       Quasi Peak       Line     61.00      -11.35      Pass
          0.31         33.13      10.00      0.89      44.03       Quasi Peak       Line     60.04      -16.02      Pass
          0.40         32.99      10.01      0.75      43.74       Quasi Peak       Line     57.76      -14.02      Pass
          0.49         32.24      10.01      0.69      42.94       Quasi Peak       Line     56.20      -13.26      Pass
          0.54         27.87      10.01      0.66      38.54       Quasi Peak       Line     56.00      -17.46      Pass
          0.18         33.57      10.00      1.49      45.06        Average         Line     54.60       -9.54      Pass
          0.22         29.56      10.00      1.19      40.75        Average         Line     52.73      -11.98      Pass
          0.27         23.08      10.00      0.99      34.07        Average         Line     51.02      -16.94      Pass
          0.27         22.59      10.00      0.98      33.58        Average         Line     51.00      -17.42      Pass
          0.31         22.42      10.00      0.89      33.32        Average         Line     50.04      -16.72      Pass
          0.40         21.29      10.01      0.75      32.04        Average         Line     47.76      -15.72      Pass
          0.49         22.25      10.01      0.69      32.95        Average         Line     46.20      -13.25      Pass
          0.54         13.61      10.01      0.66      24.28        Average         Line     46.00      -21.72      Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                                Page                17 of 29




10.3 Radiated Measurements
10.3.1 Radiated Measurements below 1GHz
Requirement(s):
  Specification(s)      Requirement                                                                                         Applicable
                                                Operation within the band 13.110–14.010 MHz:
                            (a) The field strength of any emissions within the band 13.553–13.567 MHz shall not
                                                 exceed 15,848 microvolts/meter at 30 meters.
                          (b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of
                                     any emissions shall not exceed 334 microvolts/meter at 30 meters.
                        (c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any
  47 CFR §15.225                        emissions shall not exceed 106 microvolts/meter at 30 meters.
                        (d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band                 ☒
  RSS-210 (A2.6)
                                       shall not exceed the general radiated emission limits in §15.209.
                                       Frequency range (MHz)                     Field Strength (µV/m)
                                                30 – 88                                     100
                                               88 – 216                                     150
                                                216 960                                     200
                                              Above 960                                     500




    Test Setup




                        1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                        2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                  Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                  polarization, and adjusting the antenna height in the following manner:
                                  a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
     Procedure                               rotation of the EUT) was chosen.
                                  b.         The EUT was then rotated to the direction that gave the maximum emission.
                                  c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                        3.        A Quasi-peak measurement was then made for that frequency point.
                        4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                  measured.
                                                                                               Temperature                   20.1°C
     Test Date          08/24/2015                              Environmental conditions       Relative Humidity             36%
                                                                                               Atmospheric Pressure          1026mbar
      Remark            -

       Result           ☒ Pass            ☐ Fail

Test Data      ☒ Yes (See below)             ☐ N/A
Test Plot      ☒ Yes (See below)             ☐ N/A

            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.       RF_SL15081001-CPC-008-FCC-IC_RFID
                                                                Page                  18 of 29




   Test specification:                   Radiated Measurements
                                         Temp(°C):                                  20.1°C
   Environmental Conditions:             Humidity (%):                              36%
                                                                                                                            ☒ Pass
                                         Atmospheric(mbar):                         1026mbar
                                                                                                         Result:
   Mains Power:                          208VAC, 60Hz
                                                                                                                            ☐ Fail
   Tested by:                            Osvaldo Casorla
   Test Date:                            08/24/2015
   Remarks:                              Tx mode

                                  ƒ=30MHz – 1000MHz plot at V=208VAC, ƒ=60Hz and 3 meter distance




                                                  ƒ=30MHz – 1000MHz Measurements

Frequency       Raw       Cable        AF      Level      Measurement                   Hgt      Azt       Limit          Margin     Pass
                                                                             Pol
   MHz         dBµV/m     Loss         dB     dBµV/m         Type                       cm       Deg      dBµV/m           dB        /Fail
 300.01         58.17      3.26      -25.34     36.10       Quasi Max           H      263.00   156.00      46.02         -9.92      Pass
 314.25         55.59      3.40      -24.70     34.30       Quasi Max           H      349.00    91.00      46.02         -11.72     Pass
 359.93         55.00      3.68      -23.65     35.04       Quasi Max           V      131.00    41.00      46.02         -10.98     Pass
 385.68         45.40      3.84      -23.34     25.90       Quasi Max           V      266.00    35.00      46.02         -20.12     Pass
 433.32         57.20      4.05      -22.09     39.15       Quasi Max           V      94.00    344.00      46.02         -6.87      Pass
 460.09         41.06      4.15      -21.98     23.22       Quasi Max           V      142.00   164.00      46.02         -22.80     Pass




             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                   Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.   RF_SL15081001-CPC-008-FCC-IC_RFID
                                                              Page              19 of 29




10.3.2 Radiated Measurements below 30MHz

Requirement(s):
 Specification(s)      Requirement                                                                                    Applicable
                       Operation within the band 13.110–14.010 MHz
                       (a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed
                       15,848 microvolts/meter at 30 meters.
                       (b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any
 47 CFR §15.225        emissions shall not exceed 334 microvolts/meter at 30 meters.                                      ☒
 RSS-210 (A2.6)        (c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any
                       emissions shall not exceed 106 microvolts/meter at 30 meters.
                       (d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band
                       shall not exceed the general radiated emission limits in §15.209.




   Test Setup




                       1.       The EUT and supporting equipment were set up in accordance with the requirements of the standard
                                on top of a 1.5m X 1.0m X 0.8m high, non-metallic table.
                       2.       The filtered power supply for the EUT and supporting equipment were tapped from the appropriate
   Test Setup                   power sockets located on the turntable.
                       3.       The relevant loop antenna was set at the required test distance away from the EUT and supporting
                                equipment boundary.

                       For < 30MHz, Radiated emissions were measured according to ANSI C63.10. The EUT was set to transmit at
                       the highest output power.
    Procedure          The EUT was set 3 meter away from the measuring antenna. The loop antenna was positioned 1 meter above
                       the ground from the centre of the loop. The measuring bandwidth was set to 10 kHz.
                       The limit is converted from microvolt/meter to decibel microvolt/meter.
                                                                                           Temperature               22°C
    Test Date          08/28/2015                             Environmental conditions     Relative Humidity         40%
                                                                                           Atmospheric Pressure      1027mbar
     Remark            -

     Result            ☒ Pass            ☐ Fail


Test Data      ☐ Yes (See below)            ☒ N/A
Test Plot      ☒ Yes (See below)            ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                               Page                20 of 29




   Test specification:                    Radiated Measurements
                                          Temp(°C):                              20.1°C
   Environmental Conditions:              Humidity (%):                          36%
                                                                                                                         ☒ Pass
                                          Atmospheric(mbar):                     1027mbar
                                                                                                      Result:
   Mains Power:                           208VAC, 60Hz
                                                                                                                         ☐ Fail
   Tested by:                             Osvaldo Casorla
   Test Date:                             08/28/2015
   Remarks:                               Tx mode

                                        ƒ= 100kHz – 30MHz plot, and loop antenna at 0 degree




                                                  ƒ= 100kHz – 30MHz Measurements

Frequency      Raw       Cable     AF         Level    Measurement                   Hgt      Azt       Limit          Margin     Pass
                                                                         Degree
   MHz        dBµV       Loss      dB        dBµV/m       Type                       cm       Deg      dBµV/m           dB        /Fail
  0.54         37.05     -0.18    17.59       54.46      Quasi Max           0      100.00   29.00      72.96          -18.50     Pass
  0.81         38.30     -0.20    14.28       52.38      Quasi Max           0      100.00   167.00     69.43          -17.05     Pass
  1.10         33.69     -0.22    11.83       45.30      Quasi Max           0      100.00   350.00     66.78          -21.48     Pass
  2.10         34.37     -0.29    7.03        41.11      Quasi Max           0      100.00   133.00     69.54          -28.43     Pass
  3.07         33.58     -0.31    4.37        37.65      Quasi Max           0      100.00   207.00     69.54          -31.89     Pass
  13.56        63.10     -0.62    -0.16       62.33      Quasi Max           0      100.00   182.00     123.99         -61.66     Pass




             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.    RF_SL15081001-CPC-008-FCC-IC_RFID
                                                             Page               21 of 29




                                     ƒ= 100kHz – 30MHz plot, and loop antenna at 90 degree




                                               ƒ= 100kHz – 30MHz Measurements

Frequency     Raw      Cable      AF       Level     Measurement                  Hgt      Azt       Limit          Margin   Pass
                                                                       Degree
   MHz       dBµV      Loss       dB      dBµV/m        Type                      cm       Deg      dBµV/m           dB      /Fail
  0.54       37.34      -0.18    17.59     54.76       Quasi Max          90     100.00   234.00     72.96          -18.20   Pass
  0.81       37.66      -0.20    14.29     51.74       Quasi Max          90     100.00   196.00     69.43          -17.69   Pass
  1.07       33.73      -0.22    12.04     45.55       Quasi Max          90     100.00   220.00     67.02          -21.47   Pass
  2.19       34.28      -0.29    6.73      40.72       Quasi Max          90     100.00   38.00      69.54          -28.82   Pass
  3.45       32.50      -0.31    3.70      35.89       Quasi Max          90     100.00   243.00     69.54          -33.65   Pass
  13.56      58.67      -0.62    -0.16     57.89       Quasi Max          90     100.00   101.00    123.99          -66.10   Pass




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.    RF_SL15081001-CPC-008-FCC-IC_RFID
                                                      Page               22 of 29




                                             Loop antenna at 0 degree

                                            * RBW 10 kHz
                         * Att 25 dB        * VBW 30 kHz         M1[1]          64.69 dBµV/m
                           Ref 122.0 dBµV/m   SWT 10ms                      13.560450000 MHz
                                 Limit Check              PASS
                      1Pk        Line Qpeak               PASS
                      View 110 dBµV/m

                            100 dBµV/m


                            90 dBµV/m


                            80 dBµV/m

                            Qpeak
                            70 dBµV/m                       M1

                            60 dBµV/m


                            50 dBµV/m


                            40 dBµV/m
                      Tdf

                            30 dBµV/m


                            CF 13.56 MHz                                    Span 900.0 kHz

                     Date: 28.AUG.2015    23:00:24
Frequency (MHz)       Amplitude (dBµV/m)              Azt Deg                Limit dBµV/m             Margin (dB)
    13.56045                 64.69                     100.00                   123.99                  -59.30

                                             Loop antenna at 90 degree

                                            * RBW 10 kHz
                         * Att 25 dB        * VBW 30 kHz         M1[1]          60.70 dBµV/m
                           Ref 122.0 dBµV/m   SWT 10ms                      13.560000000 MHz
                                 Limit Check              PASS
                      1Pk        Line Qpeak               PASS
                      View 110 dBµV/m

                            100 dBµV/m


                            90 dBµV/m


                            80 dBµV/m

                            Qpeak
                            70 dBµV/m
                                                            M1
                            60 dBµV/m


                            50 dBµV/m


                            40 dBµV/m
                      Tdf

                            30 dBµV/m


                            CF 13.56 MHz                                    Span 900.0 kHz

                     Date: 28.AUG.2015    23:29:38
Frequency (MHz)       Amplitude (dBµV/m)              Azt Deg                Limit dBµV/m             Margin (dB)
    13.56000                 60.70                     101.00                   123.99                  -63.29




     775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                         Visit us at: www.siemic.com; Follow us at:


                                                              Test report No.    RF_SL15081001-CPC-008-FCC-IC_RFID
                                                              Page               23 of 29




10.3.3 Frequency Stability

Requirement(s):
  Specification(s)      Requirement                                                                                  Applicable
 47 CFR §15.225 e)
                        Limit: ±0.01% of 13.56 MHz = 1356 Hz                                                            ☒
   RSS-210 (A2.6)



                                        EUT                                     Spectral Analyzer

    Test Setup
                               Environmental Chamber


                          1.   The EUT was set up inside an environmental chamber.
                          2.   The EUT was placed in the centre of the environmental.

                        Frequency Stability was measured according to 47 CFR §2.1055. Measurement was taken with spectrum
     Procedure          analyzer. The spectrum analyzer bandwidth and span was set to read in hertz. A voltmeter was used to
                        monitor when varying the voltage.
                                                                                         Temperature                 20°C
     Test Date          09/18/2015                           Environmental conditions    Relative Humidity           41%
                                                                                         Atmospheric Pressure        1025mbar

      Remark            None

       Result           ☒ Pass             ☐ Fail


Test Data      ☒ Yes (See below)           ☐ N/A
Test Plot      ☐ Yes (See below)           ☒ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.    RF_SL15081001-CPC-008-FCC-IC_RFID
                                                            Page               24 of 29




Test results:

Frequency Stability versus Temperature: The Frequency tolerance of the carrier signal shall be maintained within ± 0.01% of the
operating frequency over a temperature variation of -20ºC to +50ºC at normal supply voltage.
Reference Frequency: 13.56059118 MHz at 20°C at 208VAC, 60Hz
    Temperature                Measured Freq.                    Freq. Drift               Freq. Deviation
                                                                                                                     Pass/Fail
       (ºC)                        (MHz)                            (Hz)                    (Limit: 0.01%)
          50                     13.56051102                        -80.16                       <0.01                 Pass
          40                     13.56053106                        -60.12                       <0.01                 Pass
          30                     13.56057114                        -20.04                       <0.01                 Pass
          20                                                  Reference (13.56059118 MHz)
          10                     13.56061122                        20.04                        <0.01                 Pass
          0                      13.56061121                        20.03                        <0.01                 Pass
         -10                     13.56061122                        20.04                        <0.01                 Pass
         -20                     13.56061120                        20.02                        <0.01                 Pass


Frequency Stability versus Input Voltage: The Frequency tolerance of the carrier signal shall be maintained within ± 0.01%, the
frequency of the transmitter was measured at 85% and at 115% of the rated power supply voltage at a 20ºC environmental
temperature.
Carrier Frequency: 13.56059118 MHz at 20°C at 208VAC, 60Hz
 Measured Voltage
                               Measured Freq.                    Freq. Drift               Freq. Deviation
 ±15% of nominal                                                                                                     Pass/Fail
                                   (MHz)                            (Hz)                    (Limit: 0.01%)
      (AC)
        239.2                   13.56059410                         2.92                         <0.01                 Pass
        176.8                   13.56059111                         -0.07                        <0.01                 Pass




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                               Page                25 of 29




10.3.4 Occupied bandwidth
Requirement(s):
  Specification(s)     Requirement                                                                                          Applicable
                       The transmitter shall be operated at its maximum carrier power measured under normal test
                       conditions. The span of the analyzer shall be set to capture all products of the modulation
                       process, including the emission skirts. The resolution bandwidth shall be set to as close to 1%
                       of the selected span as is possible without being below 1%. The video bandwidth shall be set
                       to 3 times the resolution bandwidth. Video averaging is not permitted. Where practical, a
     RSS-Gen                                                                                                                   ☒
                       sampling detector shall be used given that a peak or peak hold may produce a wider
      4.6.1
                       bandwidth than actual. The trace data points are recovered and directly summed in linear
                       terms. The recovered amplitude data points, beginning at the lowest frequency, are placed in a
                       running sum until 0.5% of the total is reached and that frequency recorded. The process is
                       repeated for the highest frequency data points. This frequency is recorded. The span between
                       the two recorded frequencies is the occupied bandwidth.

                       1.        The EUT was set up inside a semi-anechoic chamber in accordance with the standard.
    Test Setup
                       2.        The EUT was placed on top of a 0.8m high, non-metallic table in a typical configuration.

                       1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                       2.        To measure conducted, a SMA cable was used to replace the EUT antenna. To measure radiated,
    Procedure
                                 an external antenna was used to detect EUT transmission signal.
                       3.        Measurement of the 99% Occupied Bandwidth of EUT transmission signal and make record.

                                                                                             Temperature                    22°C
    Test Date          09/18/2015                              Environmental conditions      Relative Humidity              39%
                                                                                             Atmospheric Pressure           1025mbar

     Remark            -

      Result           ☒ Pass             ☐ Fail


Test Data      ☐ Yes (See below)            ☒ N/A
Test Plot      ☒ Yes (See below)            ☐ N/A




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                         Page                26 of 29




Test Results:

                Radio              Channel Frequency (MHz)                 99% Occupied BW (kHz)          Limit (MHz)

             13.56MHz                     13.56057114                             1.5030                     N/A

Test Plot:
                                                        13.56 MHz




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.      RF_SL15081001-CPC-008-FCC-IC_RFID
                                                            Page                 27 of 29




Annex A. TEST INSTRUMENT

               Instrument                          Model                 Serial #          Cal Cycle      Cal Due      In use
         Conducted Emissions
              R & S Receiver                     ESHS10                830223/0009           1 Year      06/24/2016     ☒
            Spectrum Analyzer                     FSIQ7                 825555/013           1 Year      08/04/2016     ☒
            Schwarzbeck LISN                    NNLK 8129                8129-190            1 Year      08/21/2016     ☐
               CHASE LISN                        MN2050B                   1018              1 Year      08/07/2016     ☒
          Radiated Emissions
            EMI Test Receiver                      ESL6                  100178              1 Year      05/27/2016     ☒
        ETS-Lingren Loop Antenna                   6512                 00049120             1 Year      08/20/2016     ☒
   Antenna - Biconlog (30 MHz – 2 GHz)              JB1                 A030702              1 Year      08/15/2016     ☒
  DoubleRidged Waveguide Horn Antenna
                                                   3115                 10SL0059             1 Year      08/25/2016     ☐
                (1-18 GHz)
     Horn Antenna (18 GHz - 40 GHz)               AH-840                 101013              1 Year      08/28/2016     ☐
             RF Pre-Amplifier                    LPA-6-30               11140711             1 Year      02/19/2016     ☒
 Microwave Preamplifier (18 GHz - 40 GHz)         PA-840                 181251              1 Year      02/19/2016     ☐
               3 Meters SAC                         3M                     N/A               1 Year      10/30/2016     ☐
              10 Meters SAC                        10M                     N/A               1 Year      05/06/2016     ☒
           Frequency tolerance
            Spectrum Analyzer                       FSIQ7                825555/013           1 Year      08/04/2016     ☒
     Test Equity Environment Chamber                1007H                     61201           1 Year      07/28/2016     ☒
             AC Power Source                   5001 iX-208-411                56615           1 Year      07/15/2016     ☒
      RF Conducted Measurement
          Spectrum Analyzer                       N9010A              MY50210206             1 Year      08/20/2016     ☐


Test Software Version

              Test Item                          Vendor                    Software                       Version
          Radiated Emission                      EMISoft                 EMISoft Vasona                    V5.0
         Conducted Emission                      EMISoft                 EMISoft Vasona                    V5.0




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.     RF_SL15081001-CPC-008-FCC-IC_RFID
                                                           Page                28 of 29




Annex B. SIEMIC Accreditation

        Accreditations         Document                                        Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio & Telecommunications Terminal Equipment:
                                           EN45001 – EN ISO/IEC 17025
EU NB
                                           Electromagnetic Compatibility:
                                           EN45001 – EN ISO/IEC 17025

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.   RF_SL15081001-CPC-008-FCC-IC_RFID
                                                          Page              29 of 29




                                           Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMI
                                           EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measurements

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radio communications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                           S043.2




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2015-09-24 17:22:24
Document Modified: 2015-09-24 17:22:24

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC