RF Exposure Evaluation

FCC ID: W34UMRR1184

RF Exposure Info

Download: PDF
FCCID_4220009

                                            TEST REPORT
                                          No.: 18-1-0093201T02a-C1


                                                          According to:
                                                        FCC Regulations
                                                          Part 1.1310
                                                          Part 2.1091

                                                         IC-Regulations
                                                        RSS-102, Issue 5




                                                                for

                              s.m.s. smart microwave sensors GmbH

                                      UMRR-11 Type 132 radar sensor

                                                     FCC: W34UMRR1184
                                                   ISED: 10652A-UMRR1184
                                                     PMN: Demo 4D/UHD
                                                   HVIN: UMRR-11 Type 132



                                                      Laboratory Accreditation




                                        accredited according to DIN EN ISO/IEC 17025



                                                         CETECOM GmbH
                                 Laboratory Radio Communications & Electromagnetic Compatibility
                                             Im Teelbruch 116 • 45219 Essen • Germany
                                    Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                  Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                      E-mail: info@cetecom.com • Internet: www.cetecom.com


                                                     Laboratory Accreditation




The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without
the written approval of the testing laboratory                                    © Copyright: All rights reserved by CETECOM


Test Report 18-1-0093201T02a-C1, Page 2 of 15


Table of contents
1. SUMMARY OF TEST RESULTS...................................................................................................................... 3
  1.1. Summary of tests results .................................................................................................................................. 3
  1.2. Attestation:....................................................................................................................................................... 3
2. ADMINISTRATIVE DATA ............................................................................................................................... 4
  2.1. Identification of the testing laboratory ............................................................................................................. 4
  2.2. Test location .................................................................................................................................................... 4
  2.3. Organizational items ........................................................................................................................................ 4
  2.4. Applicant’s details ........................................................................................................................................... 4
  2.5. Manufacturer’s details ..................................................................................................................................... 4
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................. 5
  3.1. Summary of product description ...................................................................................................................... 5
  3.2. EUT Technologies ........................................................................................................................................... 5
  3.3. Antenna Information ........................................................................................................................................ 5
  3.4. EUT: Type, S/N etc. and short descriptions used in this test report ................................................................ 6
  3.5. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions .................................................................. 6
  3.6. EUT set-ups ..................................................................................................................................................... 6
  3.7. EUT operating modes ...................................................................................................................................... 6
4. MEASUREMENTS ............................................................................................................................................. 7
  4.1. Radio Frequency Exposure Evaluation §2.1091 .............................................................................................. 7
  4.1.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment') ................ 7
  4.2. Requirements and limits for RSS Standard ..................................................................................................... 9
  4.3. MPE Calculation method ................................................................................................................................. 9
  4.4. Evaluation Method........................................................................................................................................... 10
  4.5. Results for fixed and mobile ............................................................................................................................ 10
  4.6. Conclusion ....................................................................................................................................................... 12
  4.7. Measurement uncertainties .............................................................................................................................. 12
5. ABBREVIATIONS USED IN THIS REPORT ................................................................................................. 13
6. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ......................... 13
7. PHOTOGRAPHS OF THE EUT’S .................................................................................................................... 14
8. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ............................................................................. 15



Table of annex                                                                                                                                                Total pages
Annex 1: Separate document applicant’s document “MPE Information Requirements_V04”                                                                                             01
Annex 2: Separate document applicant’s document “UMRR-11 Type 132 Operation Description”                                                                                       21



The listed attachments are an integral part of this report.




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 3 of 15



1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not assume
responsibility for any conclusions and generalizations taken in conjunction with other specimens or samples of the type of
the item presented to tests.

The presented Equipment Under Test (in this report, hereinafter referred as EUT) integrates a Radar 76 GHz RF
Transceiver. Other implemented wireless technologies were not considered within this test report.
Following tests have been performed to show compliance with applicable FCC Part 2.1091 and FCC Part 1.1310 of the
FCC CFR 47 Rules.


1.1. Summary of tests results
              RF-Exposure Evaluation (separation distance user to RF-radiating element greater 20cm)
                                             References & Limits                               EUT
                                                                                    EUT
   Test cases       Port         FCC       Test Limit       RSS       Test Limit                op.                                               Result
                                                                                   set-up
                               Standard                   Standard                            mode
                                            RF-Field
                                            Strength
      Radio
                                             Limits:
   frequency                   §1.1310                      RSS-
                                              FCC:                    Chapter 4
    radiation      Cabinet     §2.1091                      102,                      1          2                                                 PASS
                                            “general                   Table 4
    exposure                   §2.1093                     Issue 5
                                           population/
  Requirements
                                          uncontrolled”
                                          environment
Remark: Calculations based on Datasheet delivered by applicant


The current version of the Test Report CETECOM_TR18-1-0093201T02a-C1 replaces the Test Report CETECOM_TR18-
1-0093201T02a dated 2018-10-23. The replaced Test Report is herewith invalid.

1.2. Attestation:
I declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are correct to my best
knowledge and belief to Industry Canada standards. All requirements as shown in above table are met in accordance with enumerated standards.




......................................................                                                     ....................................................
Dipl.-Ing. Niels Jeß                                                                                                                     M. Schäfers
Responsible for test section                                                                                      Responsible for test report




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 4 of 15


2. Administrative Data
2.1. Identification of the testing laboratory

Company name:                                   CETECOM GmbH
Address:                                        Im Teelbruch 116
                                                45219 Essen - Kettwig
                                                Germany
Responsible for testing laboratory:             Dipl.-Ing. Volker Wittmann
Deputy:                                         Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                   see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report:                    M. Schäfers
Receipt of EUT:                                 --
Date(s) of test:                                --
Date of report:                                 2019-02-26

2.4. Applicant’s details

Applicant’s name:                               s.m.s. smart microwave sensors GmbH
Address:                                        In den Waashainen 1
                                                38108 Braunschweig
                                                Germany
Contact person:                                 Dr.-Ing. (PhD) Ralph Mende

2.5. Manufacturer’s details


Manufacturer’s name:                            please see applicant's details

Address:                                        please see applicant's details




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 5 of 15


3. Equipment under test (EUT)
3.1. Summary of product description
 FCC ID:                            W34UMRR1184
 Product name                       UMRR-11 Type 132
                                       General population/uncontrolled environment
 Exposure category
                                       Occupational exposure/controlled environment
                                       Conducted
                                       ERP
 Output power                          EIRP
                                       Peak
                                       Source-based time-averaging
 Antenna gain                       details refer Annex 1
                                       MIMO                                            2T4R
 Technology
                                       non-MIMO                                        1T4R
                                       Standalone
 Evaluation type
                                       Simultaneous transmission
                                       20 cm
 Evaluation distance
                                       XXX cm                                       declares by manufacturer
                                       Production Unit
 EUT type                              Pre-Production Unit
                                       Engineering Unit
                                       Mobile device
 Device type
                                       Fixed device
                                       CFR 47 FCC Part 2.1091
                                       CFR 47 FCC Part 1.1310
 Refer rules
                                       KDB 447497 D01v06 October 23, 2015
                                       KDB 865664 D01v01r02 October 23, 2015

3.2. EUT Technologies
 Wireless
                       Frequency bands     Operation mode
 Technologies
                                                AEB
    Radar                76GHz
                                                ACC

3.3. Antenna Information
 Wireless                Frequency bands          Antenna type       Maximum antenna gain
 Technologies
   Radar                    76GHz                     132               Antenna 0     refer to Annex 1 & 2




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 6 of 15

3.4. EUT: Type, S/N etc. and short descriptions used in this test report

 Short
                                                                      S/N              HW                 SW
 descrip-            EUT                       Type
                                                                 serial number    hardware status    software status
 tion*)
 EUT A           Radar Sensor          UMRR-11 Type 132          0x0002CD8D               --                5
*) EUT short description is used to simplify the identification of the EUT in this test report.



3.5. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions
    AE
   short                                                              S/N              HW                 SW
 descrip-    Auxiliary Equipment               Type              serial number    hardware status    software status
  tion *)

  AE 1                 --                        --                    --                 --                --

*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.6. EUT set-ups

 EUT set-up
                       Combination of EUT and AE                                      Remarks
   no.*)

    set. 1                         EUT A                                                  --

*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.


3.7. EUT operating modes

    EUT
                  Description of
  operating                                                      Additional information
                 operating modes
 mode no.*)
    op. 1              AEB                                    Only theoretically calculation

    op. 2              ACC                                    Only theoretically calculation
*) EUT operating mode no. is used to simplify the test report.




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 7 of 15


4. Measurements
4.1. Radio Frequency Exposure Evaluation §2.1091
4.1.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location    CETECOM Essen (Chapter. 2.2.1)          Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
                For Evaluation instruments are not needed. Results are determined by calculation based on applicants delivered Tune-Up
                procedure.



4.1.2. Requirements
                             The criteria used for the evaluation of human exposure to radio frequency radiation is table 1 according FCC
                             §1.1310 and table chapter 4.2 of RSS-102 standard and it is subject for evaluation of the RF exposure prior to
      FCC: §1.1310           equipment authorization.
                             As the mobile equipment is authorized under Part 22 (Subpart H) and Part 24 of the FCC Rules, it is subject
                             for evaluation of the RF exposure prior to equipment authorization.
                             Further information on evaluating compliance with these limits can be found in the FCC’s OST/OET Bulletin
                             Number 65, ‘‘Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radiofrequency
                             Radiation.’’
                             For purposes of these requirements mobile devices are defined by the FCC as transmitters designed to be used
      FCC § 2.1091           in other than fixed locations and to generally be used in such a way that a separation distance of at least 20
                             centimeters is normally maintained between radiating structures and the body of the user or nearby persons.
                             These devices are normally evaluated for exposure potential with relation to the MPE limits given in Table 1 of
                             Appendix A.




4.1.2.1. Valid for FCC
   Table 1: LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
       Frequency range          Electric field strength         Magnetic field strength            Power density               Averaging time
            [MHz)                       [V/m]                           [A/m]                        [mW/cm²]                    [minutes]
           30 - 300                      61.4                           0.163                             1.0                        6
          300 - 1500                       -                                                             f/300                       6
        1500 - 100,000                     -                                                               5                         6
                                              (B) Limits for General Population / Uncontrolled Exposure
          0.3 – 1.34                      614                            1.63                           *(100)                        30
           1.34 – 30                     824/f                          2.19/f                        *(180/f²)                       30
           30 - 300                      27.5                           0.073                             0.2                         30
          300 - 1500                       -                               -                            f/1500                        30
         1500 – 100,0                      -                               -                              1.0                         30

f=frequency in MHz
*Plane-wave equivalent power density

NOTE1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their
employment provided those persons are fully aware of the potential for exposure and can exercise control over their
exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient through a
location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. These
limits apply to amateur station licensees and members of their immediate household as discussed in the text.

NOTE2: General population/uncontrolled exposures apply in situations in which the general public may be exposed, or in
which persons that are exposed as a consequence of their employment may not be fully aware of the potential for
exposure or cannot exercise control over their exposure. As discussed in the text, these limits apply to neighbours living
near amateur radio stations.




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 8 of 15

4.1.3 General Limits:

                         Cellular Radiotelephone Service (subpart H of part 22)
     FCC: §1.1307        Non-building-mounted antennas: height above ground level to lowest point of antenna < 10 m and total power of all
                         channels > 1000 W ERP (1640 W EIRP)
                         Personal Communications Services (part 24)
      FCC §1.1307        Broadband PCS (subpart E): non-building-mounted antennas: height above ground level to lowest point of antenna <
                         10 m and total power of all channels > 2000 W ERP (3280 W EIRP)
                          LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
                         Table 1(B) Limits for General Population/Uncontrolled Exposure
      FCC §1.1310        300–1500 MHz: f/1500 mW/cm²
                         1500–100,000 MHz: 1.0 mW/cm²
                         Subject to routine evaluation is required when the device operate at frequencies of 1.5 GHz or below and their
      FCC §2.1091        effective radiated power (ERP) is 1.5 watts or more, or if they operate at frequencies above 1.5 GHz and their ERP is
                         3 watts or more.

                         (a) Base stations are limited to 1640 watts peak equivalent isotropically radiated power (e.i.r.p.) with an antenna
      FCC §24.232        height up to 300 meters HAAT.
                         b) Mobile/portable stations are limited to 2 watts e.i.r.p. peak power, …

                         (a) Maximum ERP. The effective radiated power (ERP) of base transmitters and cellular repeaters must not exceed
      FCC §22.913        500 Watts. The ERP of mobile transmitters and auxiliary test transmitters must not exceed 7 Watts.
      FCC §27.50
                         (10) Portable stations (hand-held devices) are limited to 3 watts ERP; and
       (C )(10)
                         (4) Fixed, mobile, and portable (hand-held) stations operating in the 1710-1755 MHz band are limited to 1 watt
     FCC §27.50(d)       EIRP.

         KDBs            No. 447498 D01 v06




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 9 of 15

4.2. Requirements and limits for RSS Standard

                            2.5 Exemption Limits for Routine Evaluation

                            All transmitters are exempt from routine SAR and RF exposure evaluations provided that they comply with
                            the requirements of sections 2.5.1 or 2.5.2. If the equipment under test (EUT) meets the requirements of
                            sections 2.5.1 or 2.5.2, applicants are only required to submit a properly signed declaration of
                            compliance (see Annex C). The information contained in the RF exposure technical brief may be limited to
                            the value(s) of the maximum output power, the information that demonstrates how the maximum output
                            power of the transmitter was derived and the rationale for the separation distances applied (see Table 1),
                            which must be based on the most conservative exposure condition for the applicable module or host platform
                            test procedure requirements.
                            2.5.2 Exemption Limits for Routine Evaluation — RF Exposure Evaluation

                            RF exposure evaluation is required if the separation distance between the user and/or bystander and the
                            device’s radiating element is greater than 20 cm, except when the device operates as follows:


                                      below 20 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or
                                       less than 1 W (adjusted for tune-up tolerance);
                                      at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum e.i.r.p. of
                                       the device is equal to or less than 4.49/ƒ0.5 W (adjusted for tune-up tolerance), where ƒ is in MHz;
                                      at or above 48 MHz and below 300 MHz and the source-based, time-averaged maximum e.i.r.p.
                                       of the device is equal to or less than 0.6 W (adjusted for tune-up tolerance);
     RSS-102, Issue 5                 at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum
                                       e.i.r.p. of the device is equal to or less than 1.31 x 10 -2 ƒ0.6834 W (adjusted for tune-up
                                       tolerance), where ƒ is in MHz;
                                      at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to
                                       or less than 5 W (adjusted for tune-up tolerance).

                            In these cases, the information contained in the RF exposure technical brief may be limited to information
                            that demonstrates how the e.i.r.p. was derived.
                            2.6 User Manual Requirements

                            The applicant is responsible for providing proper instructions to the user of the radio device, and any usage
                            restrictions, including limits of exposure durations. The user manual shall provide installation and operation
                            instructions, as well as any special usage conditions (e.g. proper accessory required, including the proper
                            orientation of the device in the accessory, maximum antenna gain in the case of detachable antenna), in order
                            to ensure compliance with SAR and/or RF field strength limits. For instance, compliance distance shall be
                            clearly stated in the user manual.

                            The user manual of devices intended for controlled use shall also include information relating to the
                            operating characteristics of the device; the operating instructions to ensure compliance with SAR and/or RF
                            field strength limits; information on the installation and operation of accessories to ensure compliance with
                            SAR and/or RF field strength limits; and contact information where the user can obtain Canadian information
                            on RF exposure and compliance. Other related information may also be included.



4.3. MPE Calculation method
Predication of MPE limit at a given distance
Equation from page 18 of OET Bulletin 65, Edition 97-01

     EIRP P  G
S        
     4R 2 4R 2

             S  4R 2
GNUMERIC 
                 P

Where: S=power density
   P=power input to antenna
   G=power gain of the antenna in the direction of interest relative to an isotropic radiator
   R=distance to the centre of radiation of the antenna


CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 10 of 15

4.4. Evaluation Method
4.4.1. Standalone

Valid for Radar:
• The peak power was checked on 3 frequencies (lowest/middle/highest) within the 76GHz band and the results compared
to applicant’s declared power values (datasheet).
• No duty-cycle correction factor is applicable
Please find in the following tables the calculations based on applicants datasheet for the power values and antenna gain.


4.5. Results for fixed and mobile
4.5.1. Results for FCC Standard
4.5.1.1. MPE results for 76GHz
 Operation   Frequency on     Declared    Max. positive   Declared     Calculated   Duty cycle   Maxim um     Calculated      MPE Lim it    MPE-Value     Margin to
   Mode         channel      m axim um      tolerance   Antenna Gain   m axim um                   EIRP     EIRP incl. Duty    accord.                     Lim it:                     Maximum
                             conducted      according                      EIRP                                  cycle         Table 1
                            output pow er m anufacturer                  (Output                               ((Output
                                                                                                                                                                                        Fraction
                                                                                                                                                                        Fraction for
                                           's tune-up                   pow er +                               pow er +                                                                  Value
                                               info                     Tune-up)                             Tune-up)) x
                                                                                                                                                                        Co-location
                                                                                                                                                                                         within
                                                                                                              Duty cycle)                                               calculations
                                                                                                                                                                                       Frequency
                 (MHz)         (dBm )         (dB)         (dBi)         (dBm )        (%)         (W)           (W)          (m W/cm ^2)   (m W/cm ^2)   (m W/cm ^2)                     band

               76135,0          14,20         2,00         15,00         31,20        100%         1,318       1318,26          1,0000       0,26226        0,7377         0,2623
   AEB         76416,0          14,20         2,00         15,00         31,20        100%         1,318       1318,26          1,0000       0,26226        0,7377         0,2623        0,2623
               76697,0          14,20         2,00         15,00         31,20        100%         1,318       1318,26          1,0000       0,26226        0,7377         0,2623
               76038,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898
   ACC         76142,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898        0,6898
               76245,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898
               76278,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898
   ACC         76382,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898        0,6898
               76485,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898
               76518,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898
   ACC         76622,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898        0,6898
               76725,0          15,10         2,00         18,30         35,40        100%         3,467       3467,37          1,0000       0,68981        0,3102         0,6898




   Maximum calculated MPE value:
                              76GHz
Low est MPE-
                              1,0000                 [W/m ^2]
    Lim it:
Highest MPE-
                              0,6898                 [W/m ^2]
   value:
  Margin to
                              0,3102                 [W/m ^2]
    lim it

1. Output power including tune-up tolerance;
2. Output power was adjust to duty cycle at 100% if measured duty cycle less than 98%;
3. MPE evaluate distance is 20cm from user manual provide by manufacturer;
4. Depending on output power and antenna gain only the worst case is reported;




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 11 of 15

4.5.2. Results for RSS Standard
4.5.2.1. MPE Results for 76GHz
 Operation   Frequency on    Measured Max. positive       Declared     EIRP     Duty cycle   Maxim um    Equivalent    MPE Lim it   MPE-Value   Margin                    Maximum
   Mode         channel      m axim um      tolerance   Antenna Gain                           EIRP         EIRP        accord.
                             conducted      according                                                   (EIRP x duty    Table 4
                                                                                                                                                                           Fraction
                                                                                                                                                           Fraction for
                            output pow er m anufacturer                                                    cycle)                                                           Value
                                           's tune-up
                                                                                                                                                           Co-location
                                                                                                                                                                            within
                                               info                                                                                                        calculations
                 (MHz)         (dBm )          (dB)         (dBi)      (dBm )      (%)         (W)         (m W)       (W/m ^2)      (W/m ^2)   (W/m ^2)
                                                                                                                                                                          Frequency
                                                                                                                                                                             band
               76135,0          14,20         2,00         15,00       31,20      100%         1,318      1318,26       56,7819       2,6226    54,1594       0,0462
   AEB         76416,0          14,20         2,00         15,00       31,20      100%         1,318      1318,26       56,9251       2,6226    54,3025       0,0461        0,0462
               76697,0          14,20         2,00         15,00       31,20      100%         1,318      1318,26       57,0681       2,6226    54,4455       0,0460
               76038,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       56,7325       6,8981    49,8344       0,1216
   ACC         76142,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       56,7855       6,8981    49,8874       0,1215        0,1216
               76245,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       56,8380       6,8981    49,9399       0,1214
               76278,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       56,8548       6,8981    49,9567       0,1213
   ACC         76382,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       56,9078       6,8981    50,0097       0,1212        0,1213
               76485,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       56,9602       6,8981    50,0621       0,1211
               76518,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       56,9770       6,8981    50,0789       0,1211
   ACC         76622,0          15,10         2,00         18,30       35,40      100%         3,467      3467,37       57,0299       6,8981    50,1318       0,1210        0,1211
               76725,0          10,20         2,00         18,30       30,50      100%         1,122      1122,02       57,0823       2,2322    54,8501       0,0391




   Maximum calculated MPE value:
                              76GHz
Low est MPE-
                             56,7325                 [W/m ^2]
    Lim it:
Highest MPE-
                              6,8981                 [W/m ^2]
   value:
  Margin to
                             49,8344                 [W/m ^2]
    lim it

1. Output power including tune-up tolerance;
2. Output power was adjust to duty cycle at 100% if measured duty cycle less than 98%;
3. MPE evaluate distance is 20cm from user manual provide by manufacturer;
4. Depending on output power and antenna gain only the worst case is reported;




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 12 of 15

4.6. Conclusion
The measurement results do comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile
device.

The measurement results do comply with the RSS-102, Issue 5.

4.7. Measurement uncertainties
The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate coverage factor
k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and it’s
contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
     RF-Measurement             Reference        Frequency range                                               Remarks
                                                                           confidence level of 95%
 Conducted emissions                      9 kHz - 150 kHz            4.0 dB
                             CISPR 16-2-1                                                                          -
 (U CISPR)                                150 kHz - 30 MHz           3.6 dB
 Radiated emissions                       30 MHz - 1 GHz             4.2 dB
                             CISPR 16-2-3                                                                       E-Field
 Enclosure                                1 GHz - 18 GHz             5.1 dB
 Disturbance power           CISPR 16-2-2 30 MHz - 300 MHz           -                                             -
                                                                                                              Substitution
 Power Output radiated              -        30 MHz - 4 GHz          3.17 dB
                                                                                                                method
                                                                     Cel- Cel-
                                             Set-up No.                           BT1 W1 W2
                                                                      C1     C2
 Power Output conducted             -        9 kHz - 12.75 GHz       N/A 0.60      --    --    --                  -
                                             12.75 - 26.5GHz         N/A 0.82      --    --    --
 Conducted emissions                -        9 kHz - 2.8 GHz         0.70 N/A      --    --    --             N/A - not
 on RF-port                                  2.8 GHz - 12.75GHz      1.48 N/A      --    --    --             applicable
                                             12.75 GHz - 18GHz       1.81 N/A      --    --    --
                                             18 GHz - 26.5GHz        1.83 N/A      --    --    --
                                                                     0.1272 ppm (Delta Marker)                 Frequency
 Occupied bandwidth                 -        9 kHz - 4 GHz                                                        error
                                                                     1.0 dB                                      Power
                                    -                                0.1272 ppm (Delta Marker)                 Frequency
 Emission bandwidth                          9 kHz - 4 GHz                                                        error
                                    -                                See above: 0.70 dB                          Power
 Frequency stability                -        9 kHz - 20 GHz          0.0636 ppm                                     -
                                             150 kHz - 30 MHz        5.0 dB                                    Magnetic
 Radiated emissions                          30 MHz - 1 GHz          4.2 dB                                       field
                                    -
 Enclosure                                   1 GHz - 20 GHz          3.17 dB                                     E-field
                                                                                                              Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 13 of 15


5. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




6. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                              FCC, Federal Communications
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
      MRA US-EU                                                                               Commission
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)
          0003                                                                                Laboratory Division, USA
 348                 Mains Ports Conducted Interference Measurements
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         IC, Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348     T-1967      Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 14 of 15


7. Photographs of the EUT’s




Front view of UMRR-11 Type 132




Rear view of UMRR-11 Type 132




CETECOM_TR18-1-0093201T02a-C1


Test Report 18-1-0093201T02a-C1, Page 15 of 15


8. Versions of test reports (change history)

      Version        Applied changes              Date of release
        --           Initial release               2018-10-23
        C1           Revised tuneup information    2019-02-26




End of report




CETECOM_TR18-1-0093201T02a-C1



Document Created: 2019-03-05 11:35:31
Document Modified: 2019-03-05 11:35:31

© 2024 FCC.report