FCC Report_DFS

FCC ID: W2Z-01000006

Test Report

Download: PDF
FCCID_2473652

                                                                                         Test report No.           : 103156985—G
                                                                                         Page                      : 1 of 23
                                                                                         Issued date               : October 28, 2014
                                                                                         Revised date              : December 12, 2014
                                                                                         FCC ID                    : W2Z—01000006




                                 RADIO TEST REPORT
                                        Test Report No. : 103156988—G
             Applicant                           f         FUJIFILM Corporation

             Type of Equipment                   f         Flat Panel Sensor

             Model No.                           f         DR—ID1201SE

             FCC ID                              f         Ww27—01000006

             Test regulation                     f         FCC Part 15 Subpart E: 2014
                                                            (DFS test only)

             Test result                         f         Complied

 1.    This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc.
 2.    The results in this report apply only to the sample tested.
 3.    This sample tested is in compliance with the limits of the above regulation.
 4.    The test results in this test report are traceable to the national or international standards.
 5.    This test report must not be used by the customer to claim product certification, approval, or endorsement
       by any agency ofthe Federal Government.
 6.    The opinions and the interpretations to the result of the description in this report are outside scopes where
       Japan has been accredited.

                          Date       of test
                            ave of      tes                          September 22, 2014



                          Representative test
                          engineer:                           JM

                                                                      Tatsuya
                                                                           _  Arai
                                                                        Engineer
                                                           Consumer Technology Division



                          Approved is :                       /?/%m(
                                                                  Toyokazu Imamura
                                                                         Leader
                                                           Consumer Technology Division
                                                                                                            ”’u/gu\“




                                                                                         w                              LW
                                                                                           8      x."



                                                                                         f/ s
                                                                                                                           LAB
                                                                                           Bz/’/A
                                                                                             e\   I1 \\\‘
                                                                                                                           JAB
                                                                                                                           Testing
                                                                                                                           RTLO261
|:| The testing in which "Non—accreditation"is displayed is outside the accreditation scopes in UL Japan.                      nzein
E There is no testing item of "Non—accreditation".


UL Japan, Inc.
Shonan EMC Lab.
1—22—3 Megumigaoka, Hiratsuka—shi, Kanagawa—ken, 259—1220 JAPAN
Telephone:        +81 463 50 6400
Facsimile:          +81 463 50 6401                                                                              13—EM—FO429


                                                                          Test report No.   : 10315698S-G
                                                                          Page              : 2 of 23
                                                                          Issued date       : October 28, 2014
                                                                          Revised date      : December 12, 2014
                                                                          FCC ID            : W2Z-01000006




                                  REVISION HISTORY
                             Original Test Report No.: 10315698S-G

Revision        Test report No.     Date                   Page revised   Contents
- (Original)    10315698S-G         October 28, 2014       -              -
1               10315698S-G         December 12, 2014      4              Correction of Rating




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                                   Test report No.        : 10315698S-G
                                                                                                   Page                   : 3 of 23
                                                                                                   Issued date            : October 28, 2014
                                                                                                   FCC ID                 : W2Z-01000006




CONTENTS                                                                                                                                PAGE


SECTION 1: Customer information......................................................................................... 4
SECTION 2: Equipment under test (E.U.T.) ........................................................................... 4
SECTION 3: Scope of Report ................................................................................................... 5
SECTION 4: Test specification, procedures & results............................................................. 5
SECTION 5: Operation of E.U.T. during testing..................................................................... 10
SECTION 6: In-Service Monitoring for Channel Move Time, Channel Closing Transmission
Time ............................................................................................................................................ 16
SECTION 7: In-Service Monitoring for Non-Occupancy Period............................................ 19
APPENDIX 1: Data of DFS test ................................................................................................. 21
APPENDIX 2: Test instruments ................................................................................................ 22
APPENDIX 3: Photographs of test setup .................................................................................. 23




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                            Test report No.      : 10315698S-G
                                                                                            Page                 : 4 of 23
                                                                                            Issued date          : October 28, 2014
                                                                                            Revised date         : December 12, 2014
                                                                                            FCC ID               : W2Z-01000006



SECTION 1: Customer information
 Company Name                        :   FUJIFILM Corporation
 Address                             :   2-26-30 Nishiazabu Minatoku Tokyo 106-8620, Japan
 Telephone Number                    :   81-3-6271-1975
 Facsimile Number                    :   81-3-6271-1189
 Contact Person                      :   Mitsuyuki Komiya

SECTION 2: Equipment under test (E.U.T.)
2.1       Identification of E.U.T.

 Type of Equipment                   :   Flat Panel Sensor
 Model Number                        :   DR-ID1201SE
 Serial Number                       :   Refer to Section 5.2
 Rating                              :   DC 8V(Battery)
 Country of Mass-production          :   Japan
 Condition of EUT                    :   Engineering prototype
                                         (Not for Sale: This sample is equivalent to mass-produced items.)
 Receipt Date of Sample              :   September 9, 2014
 Modification of EUT                 :   The test lab did not make the modification to the EUT supplied from the customer to
                                         have it pass the tests.

2.2       Product description

Model: DR-ID1201SE (referred to as the EUT in this report) is Flat Panel Sensor.
General specification:
Clock frequency(ies) in the system       :      40MHz

Radio specification:
Radio Type                                  :       Transceiver
Method of Frequency Generation              :       Synthesizer
Power Supply (inner)                        :       DC3.3V

                       IEEE802.11b              IEEE802.11g         IEEE802.11a             IEEE802.11n                 IEEE802.11n
                                                                                            (20M band)                  (40M band)
 Frequency             2412-2462MHz             2412-2462MHz        5180-5320MHz            2412-2462MHz                2422-2452MHz
 of operation                                                       5500-5700MHz            5180-5320MHz                5190-5310MHz
                                                                    5745-5825MHz            5500-5700MHz                5510-5670MHz
                                                                                            5745-5825MHz                5755-5795MHz
 Type of modulation    DSSS                     OFDM-CCK            OFDM
                       (CCK, DQPSK,             (64QAM, 16QAM,      (64QAM, 16QAM, QPSK, BPSK)
                       DBPSK)                   QPSK, BPSK)
 Channel spacing       5MHz                                         20MHz                   2.4GHz band                 2.4GHz band
                                                                                            5MHz                        5MHz
                                                                                            5GHz band                   5GHz band
                                                                                            20MHz                       40MHz


Antenna                                    Antenna #1 (Bottom)                                      Antenna #0 (Side)
                           2 pcs. (*. Separation distance between the antenna 1 and the antenna: 417mm )
Antenna quantity           11b,g,a: One selected Tx antenna operation.
                           11n(20HT),n(40HT): One selected Tx antenna operation (MCS0~7) / Two Tx antenna operation (MCS8~13)
Antenna model                       113Y120035A (cable length: 300mm)                     113Y1200036A (cable length: 575mm)
Antenna type / connector                     Monopole antenna / Connector; PCB side: U.FL, Antenna side: soldered
type
Antenna gain (max.peak)                     -5.1 dBi (2.4GHz),                                    -6.9 dBi (2.4GHz)
(excluding cable loss)                       -1.3 dBi (5GHz)                                       -1.8 dBi (5GHz)


UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                 Test report No.   : 10315698S-G
                                                                                 Page              : 5 of 23
                                                                                 Issued date       : October 28, 2014
                                                                                 FCC ID            : W2Z-01000006



FCC 15.31 (e)
The EUT is a battery-operated device and test was performed with the full-charged battery.
Therefore, the EUT complies with the requirement.

FCC 15.203
It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore the
EUT complies with the requirement.


SECTION 3: Scope of Report
The EUT has the channels from 5180 to 5320MHz and 5500 to 5700MHz.
This report only covers DFS requirement subject to 5250-5350MHz and 5500 to 5700MHz bands, as specified by the
following referenced procedures.



SECTION 4: Test specification, procedures & results

4.1     Test Specification

Test Specification                  :        FCC Part 15 Subpart E: 2014,
                                             final revised on August 15, 2014 and effective October 14, 2014
Title                               :        FCC 47CFR Part15 Radio Frequency Device
                                             Subpart E Unlicensed National Information Infrastructure Devices
                                             Section 15.407 General technical requirements

* The revision on August 15, 2014 does not affect the test specification applied to the EUT.

Test Specification                  :        KDB905462 D02 UNII DFS Compliance Procedures New Rules v01r01
Title                               :        COMPLIANCE MEASUREMENT PROCEDURES FOR UNLICENSED-
                                             NATIONAL INFORMATION INFRASTRUCTURE DEVICES
                                             OPERATING IN THE 5250-5350MHz AND 5470-5725MHz BANDS
                                             INCORPORATING DYNAMIC FREQUENCY SELECTION

Test Specification                  :        KDB905462 D03 Client Without DFS New Rules v01r01
Title                               :        U-NII CLIENT DEVICES WITHOUT RADAR DETECTION CAPABILITY




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                        Test report No.       : 10315698S-G
                                                                                        Page                  : 6 of 23
                                                                                        Issued date           : October 28, 2014
                                                                                        FCC ID                : W2Z-01000006


4.2    Procedures and results

Table 2: Applicability of DFS Requirements

       Requirement             Operating Mode          Test Procedures &          Deviation         Results
                               Client without          Limits
                               Radar Detection
       U-NII Detection         Not required            FCC, KDB 905462 D02        N/A               N/A
       Bandwidth                                       Section 7.8.1
       Initial Channel         Not required            FCC15.407 (h)(2)           N/A               N/A
       Availability Check
                                                       FCC, KDB 905462 D02
       Time
                                                       Section 7.8.2.1
                                                       RSS-210 A9.3
       Radar Burst at the      Not required            FCC15.407 (h)(2)           N/A               N/A
       Beginning of the                                FCC, KDB 905462 D02
       Channel Availability                            Section 7.8.2.2
       Check Time
                                                       RSS-210 A9.3
       Radar Burst at the      Not required            FCC15.407 (h)(2)           N/A               N/A
       End of the Channel                              FCC, KDB 905462 D02
       Availability Check                              Section 7.8.2.3
       Time
                                                       RSS-210 A9.3
       In-Service Monitoring   Yes                     FCC15.407 (h)(2)           N/A               Complied
       for Channel Move
                                                       FCC, KDB 905462 D02
       Time, Channel
                                                       Section 7.8.3
       Closing Transmission
       Time                                            RSS-210 A9.3
       In-Service Monitoring   Yes *                   FCC15.407 (h)(2)           N/A               Complied
       for Non-Occupancy
                                                       FCC, KDB 905462 D02
       period
                                                       Section 7.8.3
                                                       RSS-210 A9.3
       Statistical             Not required            FCC15.407 (h)(2)           N/A               N/A
       Performance Check                               FCC, KDB 905462 D02
                                                       Section 7.8.4

      *Although this test was not required in FCC, KDB 905462 D02, it was performed as additional test.

Table 3: DFS Detection Thresholds for Master Devices and Client Devices With Radar
       Maximum Transmit Power                                     Value (See Notes 1, 2 and 3)
       E.I.R.P. ≥ 200 milliwatt                                   -64 dBm
       E.I.R.P. < 200 milliwatt and                               -62 dBm
       power spectral density < 10dBm/MHz
       E.I.R.P. < 200 milliwatt that do not meet the power -64 dBm
       spectral density requirement
       Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
       Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test
       transmission waveforms to account for variations in measurement equipment. This will ensure that the test
       signal is at or above the detection threshold level to trigger a DFS response.
       Note 3: E.I.R.P. is based on the highest antenna gain. For MIMO devices refer to KDB Publication 662911
       D01.


UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                      Test report No.     : 10315698S-G
                                                                                      Page                : 7 of 23
                                                                                      Issued date         : October 28, 2014
                                                                                      FCC ID              : W2Z-01000006



Table 4 DFS Response Requirement Values
      Parameter                                                     Value
      Non-occupancy period                                          Minimum 30 minutes
      Channel Availability Check Time                               60 seconds
      Channel Move Time                                             10 seconds
                                                                    See Note 1
      Channel Closing Transmission Time                             200 milliseconds + an aggregate of 60
                                                                    milliseconds over remaining 10 second period.
                                                                    See Notes 1 and 2
      U-NII Detection Bandwidth                                     Minimum 100% of the U-NII 99% transmission
                                                                    power bandwidth
                                                                    See Note 3
      Note 1: The Channel Move Time and the Channel Closing Transmission Time should be performed with
      Radar Type 0. The measurement timing begins at the end of the Radar Type 0 burst.
      Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning
      of the Channel Move Time plus any additional intermittent control signals required to facilitate a Channel
      move (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration
      of control signal will not count quiet periods in between transmissions.
      Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used. For each
      frequency step the minimum percentage of detection is 90 percent. Measurements are performed with no data
      traffic.

Table 5 Short Pulse Radar Test Waveform
    Radar Type           Pulse Width          PRI                   Number of Pulses      Minimum              Minimum
                         (µsec)               (µsec)                                      Percentage of        Number of
                                                                                          Successful           Traials
                                                                                          Detection
            0                    1                   1428                    18              See Note 1             See Note 1
            1                    1            Test A: 15 unique          Roundup (               60%                    30
                                                  PRI values              (1 / 360)
                                              randomly selected       x ( (19 x 10^6 )
                                              from the list of 23    / PRI [micro sec.]
                                                 PRI values in                ))
                                                   Table 5a
                                              Test B: 15 unique
                                                  PRI values
                                              randomly selected
                                              within the range of
                                               518-3066 micro
                                                  sec., with a
                                                   minimum
                                                increment of 1
                                                  micro sec.,
                                                excluding PRI
                                              values selected in
                                                    Test A
             2                   1-5               150-230                23-29                  60%                    30
             3                  6-10               200-500                16-18                  60%                    30
             4                 11-20               200-500                12-16                  60%                    30
    Aggregate (Rader Types 1-4)                                                                  80%                   120
    Note 1: Short Pulse Radar Type 0 should be used for the detection bandwidth test, channel move time, and channel closing time
    tests.

UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                   Test report No.    : 10315698S-G
                                                                                   Page               : 8 of 23
                                                                                   Issued date        : October 28, 2014
                                                                                   FCC ID             : W2Z-01000006



Table 5a Pulse Repetition Interval Values for Test A
    Pulse Repetition        Pulse Repetition Frequency       Pulse Repetition Interval
    Frequency Number        (Pulses Per Second)              (Micro seconds)
             1                          1930.5                          518
             2                          1858.7                          538
             3                          1792.1                          558
             4                          1730.1                          578
             5                          1672.2                          598
             6                          1618.1                          618
             7                          1567.4                          638
             8                          1519.8                          658
             9                          1474.9                          678
             10                         1432.7                          698
             11                         1392.8                          718
             12                          1355                           738
             13                         1319.3                          758
             14                         1285.3                          778
             15                         1253.1                          798
             16                         1222.5                          818
             17                         1193.3                          838
             18                         1165.6                          858
             19                          1139                           878
             20                         1113.6                          898
             21                         1089.3                          918
             22                         1066.1                          938
             23                          326.2                         3066


Table 6 Long Pulse Radar Test Waveform
    Radar Type     Pulse Width    Chip Width    PRI (µsec)       Number of      Number of        Minimum         Minimum
                   (µsec)         (MHz)                          Pulses per     Burst            Percentage      Number of
                                                                 Burst                           of Successful   Trials
                                                                                                 Detection
          5          50-100           5-20       1000-2000            1-3            8-20            80%               30

Table 7 Frequency Hopping Radar Test Waveform

    Radar Type     Pulse Width    PRI (µsec)    Pulse per        Hopping        Hopping          Minimum         Minimum
                   (µsec)                       Hop (kHz)        Rate (kHz)     Sequence         Percentage      Number of
                                                                                Length           of Successful   Trials
                                                                                (msec)           Detection
          6             1             333                9          0.333           300              70%               30




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                               Test report No.    : 10315698S-G
                                                                               Page               : 9 of 23
                                                                               Issued date        : October 28, 2014
                                                                               FCC ID             : W2Z-01000006



4.3       Test Location

UL Japan, Inc. Shonan EMC Lab.
1-22-3, Megumigaoka, Hiratsuka-shi, Kanagawa-ken 259-1220 JAPAN
Telephone number        :        +81 463 50 6400
Facsimile number        :        +81 463 50 6401

                                                                        Size of reference
                                    IC                                                           Maximum
                                                   Width x Depth x      ground plane (m) /
                                    Registration                                                 measurement
                                                   Height (m)           horizontal
                                    No.                                                          distance
                                                                        conducting plane
      No.1 Semi-anechoic chamber    2973D-1        20.6 x 11.3 x 7.65   20.6 x 11.3              10m
      No.2 Semi-anechoic chamber    2973D-2        20.6 x 11.3 x 7.65   20.6 x 11.3              10m
      No.3 Semi-anechoic chamber    2973D-3        12.7 x 7.7 x 5.35    12.7 x 7.7               5m
      No.4 Semi-anechoic chamber    -              8.1 x 5.1 x 3.55     8.1 x 5.1                -
      No.1 Shielded room            -              6.8 x 4.1 x 2.7      6.8 x 4.1                -
      No.2 Shielded room            -              6.8 x 4.1 x 2.7      6.8 x 4.1                -
      No.3 Shielded room            -              6.3 x 4.7 x 2.7      6.3 x 4.7                -
      No.4 Shielded room            -              4.4 x 4.7 x 2.7      4.4 x 4.7                -
      No.5 Shielded room            -              7.8 x 6.4 x 2.7      7.8 x 6.4                -
      No.6 Shielded room            -              7.8 x 6.4 x 2.7      7.8 x 6.4                -
      No.1 Measurement room         -              2.55 x 4.1 x 2.5     -                        -



4.4     Uncertainty

The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.

Time Measurement uncertainty for this test was: (±) 0.012%


4.5     Test set up, Data of DFS test, and Test instruments of DFS

Refer to APPENDIX.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                Test report No.   : 10315698S-G
                                                                                Page              : 10 of 23
                                                                                Issued date       : October 28, 2014
                                                                                FCC ID            : W2Z-01000006




SECTION 5: Operation of E.U.T. during testing

5.1      Operating Modes

The EUT, which is a Client Device without Radar detection capability, operates over the 5260-5320MHz and 5500-
5700MHz.

Power level of the EUT [dBm]

           Antenna            Band Output Power (Min) Output Power(Max)
      Monopole Antenna *1)    W53           10.77                    14.88
                              W56           11.56                    17.10
*1) Refer to 10315698S-F FCC Part 15E (FCC 15.407) report for other parts than DFS.

WLAN traffic is generated by the software to ping from the Master to the Client. That software has random ping
intervals. (Channel loading was over 17%)
Software name & version: ExPing Version 1.33


The EUT utilizes the 802.11a and 802.11n architecture, with a nominal channel bandwidth.
The EUT had used IEEE 802.11n (HT40) (widest mode) .


The FCC ID for the Master Device used with EUT for DFS testing is LDK102073.


The rated output power of the Master unit is >200mW(23dBm). Therefore the required interference threshold level is –
64 dBm. After correction for antenna gain and procedural adjustments, the required conducted threshold at the antenna
port is –64 + 1 + 3.5=-59.5 dBm (threshold level + additional 1dB + antenna gain).

It is impossible for users to change DFS control, because the DFS function is written on the firmware and users cannot
access it.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                  Test report No.        : 10315698S-G
                                                                                  Page                   : 11 of 23
                                                                                  Issued date            : October 28, 2014
                                                                                  FCC ID                 : W2Z-01000006



5.2     Configuration and peripherals

                                                     Conducted                       4
                      B          A                    method              C                  E
                                                      system


                                                                              2                      5
                                                                              D                  F


                                                                              3                     6


                                                                              AC100V/50Hz
                                                                  : Standard Ferrite Core


Description of EUT and Support equipment
 No. Item                    Model number               Serial number              Manufacturer                 Remarks
       Wireless LAN board    SX-PCEAN(FF)               00809261B110               Silex                        EUT
 A
       *1)
 B     Flat Panel Sensor     DR-ID 613SE *2)            E321154                    Fujifilm                     -
       Wireless LAN access   AIR-AP1262N-A-K9           FTX1619E5EZ                Cisco Systems                FCC ID:
 C     point (Master Device)                                                                                    LDK102073

 D      AC Adapter               EADP-18MB              DAB1528MANP                Cisco Systems                -
 E      Notebook Computer        DELL Vostro V1510      29090510205                Dell                         -
 F      AC Adaptor               LA65NS1-00             71615-93B-385D             Dell                         -
*1) This board is installed DR-ID1201SE.
*2) It was used to operate the Wireless LAN board.

List of cables used
 No. Cable Name                           Length (m)                                 Shield
                                                                       Cable                     Connector
 2     Access Point DC Power                      1.8                Unshielded                  Unshielded
 3     Access Point AC Power                      2.0                Unshielded                  Unshielded
 4     LAN                                        3.0                Unshielded                  Unshielded
 5     DELL PC DC Power                           1.8                Unshielded                  Unshielded
 6     DELL PC AC Power                           0.7                Unshielded                  Unshielded




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                      Test report No.       : 10315698S-G
                                                                                      Page                  : 12 of 23
                                                                                      Issued date           : October 28, 2014
                                                                                      FCC ID                : W2Z-01000006



5.3       Test and Measurement System

SYSTEM OVERVIEW

The measurement system is based on a conducted test method.

The software selects waveform parameters from within the bounds of the signal type on a random basis using uniform
distribution. The short pulse types 2, 3, and 4, the long pulse type 5, and the frequency hopping type 6 parameters are
randomized at run-time.

The signal monitoring equipment consists of a spectrum analyzer with the capacity to display 8001 bins on the
horizontal axis. A time-domain resolution of 2 msec/bin is achievable with a 16 second sweep time, meeting the 10
seconds short pulse reporting criteria. The aggregate ON time is calculated by multiplying the number of bins above a
threshold during a particular observation period by the dwell time per bin, with the analyzer set to peak detection. A
time-domain resolution of 3 msec/bin is achievable with a 24 second sweep time, meeting the 22 second long pulse
reporting criteria and allowing a minimum of 10 seconds after the end of the long pulse waveform.


FREQUENCY HOPPING RADAR WAVEFORM GENERATING SUBSYSTEM

The first 100 frequencies are selected out of the hopping sequence of the randomized 475 hop frequencies.
Only a Burst that has the frequency falling within the receiver bandwidth of the tested U-NII device is selected among
those frequencies. (Frequency-domain simulation). The radar waveform generated at the start time of the selected Burst
(Time-domain simulation) is download to the Signal Generator.
If all of the randomly selected 100 frequencies do not fall within the receiver bandwidth of the U-NII device, the radar
waveform is not used for the test.

CONDUCTED METHODS SYSTEM BLOCK DIAGRM
        To Spectrum Analyzer
        10MHz out


                               Signal Generator   Notebook
                                                  Computer

                                                                                                                                 See Page 11


                                                  PowerDivider               Power
                                                  DC to 26.5GHz            Splitters/        Attenuator   Attenuator   A
                                                                           Combiners           (20dB)        (20dB)
                                                                                                                            D:
See Page 11                    B   Attenuator
                                   (20dB)                                                                                  Master
                                                                                        C
  A:
                         Power
   EUT                   Splitters/
                         Combiners
  (Client)

                                                                                                 Spectrum Analyzer
                                                                    From Signal Generator
                                                                    10MHz in




MEASUREMENT SYSTEM FREQUENCY REFERENCE

Lock the signal generator and the spectrum analyzer to the same reference sources as follows: Connect the 10MHz OUT
on the signal generator to the 10MHz IN on the spectrum analyzer and set the spectrum analyzer 10MHz In to On.



UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                  Test report No.    : 10315698S-G
                                                                                  Page               : 13 of 23
                                                                                  Issued date        : October 28, 2014
                                                                                  FCC ID             : W2Z-01000006



SYSTEM CALIBRATION

Step 1: Set the system as shown in Figure 3 of FCC, KDB 905462 Section 7.2.2.

Step 2: Adjust each attenuator to fulfill the following three conditions:
         - WLAN can be communicated, and
         - Rader detection threshold level is bigger than Client Device traffic level on the spectrum analyzer, and
         - Master Device traffic level is not displayed on the spectrum analyzer.

Step 3: Terminate 50 ohm at B and C points, and connect the spectrum analyzer to the point A.
(See the figure on page 12)
At the point A, adjust the signal generator and spectrum analyzer to the center frequency of the channel to be measured.
Download the applicable radar waveforms to the signal generator. Select the radar waveform, trigger a burst manually
and measure the amplitude on the spectrum analyzer. Readjust the amplitude of the signal generator as required so that
the peak level of the waveform is at a displayed level equal to the required or desired interference detection threshold.
Separate signal generator amplitude settings are determined as required for each radar type.

Step 4: Without changing any of the instrument settings, restore the system setting to Step 2 and adjust the Reference
Level Offset of the spectrum analyzer to the level at Step 3.

By taking the above steps 1 to 4, the spectrum analyzer displays the level of the signal generator as received at the
antenna ports of the Master Device.

See Clause 5.4 for Plots of Noise, Rader Waveforms, and WLAN signals.


5.4      Plots of Noise, Rader Waveforms, and WLAN signals

Plots of System Noise Floor
(for 11n (HT40), 5310MHz)




It was confirmed that the EUT did not transmit before having received appropriate control signals from a Master Device.




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                  Test report No.   : 10315698S-G
                                                                  Page              : 14 of 23
                                                                  Issued date       : October 28, 2014
                                                                  FCC ID            : W2Z-01000006




Plots of Radar Waveforms
(for 11n (HT40), 5310MHz)
Rader Type 1




(for 11n (HT40), 5310MHz)
Rader Type 5




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


lal
      ® lt _   A


                                                                                Test report No.   : 10315698S-G
                                                                                Page              : 16 of 23
                                                                                Issued date       : October 28, 2014
                                                                                FCC ID            : W2Z-01000006



SECTION 6: In-Service Monitoring for Channel Move Time, Channel Closing Transmission
Time
6.1     Operating environment

Test place                : No.5 Shielded Room
Temperature               : 26 deg.C
Humidity                  : 43 %RH


6.2     Test Procedure

Transfer files from the Master Device to the Client Device on the tested channel during the entire period of the test.
The Radar Waveform generator sends a Burst of pulses for one of the Short Pulse Radar Types 0-4 at levels defined ,
on the Operating Channel. An additional 1 dB is added to the radar test signal to ensure it is at or above the DFS
Detection Threshold, accounting for equipment variations/errors.
Observe the transmissions of the EUT at the end of the radar Burst on the Operating Channel for duration greater than
10 seconds.


6.3     Test data

(for 11n (HT40), 5310MHz)
          Test Item              Unit       Measurement Time         Limit       Results

  Channel Move Time *1)         [sec]              1.790             10.000       Pass
     Channel Closing
  Transmission Time *2)        [msec]               20                 60         Pass

*1) Channel Move Time is calculated as follows:
    (Channel Move Time) = (End of Transmission) - (End of Burst) = 2.976 – 1.186

*2) Channel Closing Transmission Time is calculated from (End of Burst + 200msec) to (End of Burst + 10sec )
    (Channel Closing Transmission Time) = (Number of analyzer bins showing transmission)*(dwell time per bin)
                                        = 10 x 2 (msec)




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                            Test report No.   : 10315698S-G
                                                                            Page              : 17 of 23
                                                                            Issued date       : October 28, 2014
                                                                            FCC ID            : W2Z-01000006



(for 11n (HT40), 5310MHz)

Radar Type 1




Marker 1: - End of Burst                   : 1.186 s
Marker 2: - End of Transmission            : 2.976 s




                                      End of Burst
                                                              End of Transmission




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                          Test report No.   : 10315698S-G
                                                                          Page              : 18 of 23
                                                                          Issued date       : October 28, 2014
                                                                          FCC ID            : W2Z-01000006




(for 11n (HT40), 5310MHz)
Radar Type 5




Marker 1 : End of Burst                    : 12710 ms
Marker 2 : End of Transmission             : 13810ms


6.4      Test result

Test result: Pass
Date : September 22, 2014                  Test engineer : Tatsuya Arai




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                                   Test report No.   : 10315698S-G
                                                                                   Page              : 19 of 23
                                                                                   Issued date       : October 28, 2014
                                                                                   FCC ID            : W2Z-01000006



SECTION 7: In-Service Monitoring for Non-Occupancy Period
7.1      Operating environment

Test place                 : No.5 Shielded Room
Temperature                : 26 deg.C
Humidity                   : 43 %RH


7.2      Test Procedure

The following two tests are performed:

1). Transfer files from the Master Device to the Client Device on the tested channel during the entire period of the test.
The Radar Waveform generator sends a Burst of pulses for one of the Radar Types 0-6 at levels defined
on the Operating Channel. An additional 1 dB is added to the radar test signal to ensure it is at or above the DFS
Detection Threshold, accounting for equipment variations/errors.
Observe the transmissions of the EUT after the Channel Move Time on the Operating Channel for duration greater than
30 minutes.

2). Transfer files from the Master Device to the Client Device on the tested channel during the entire period of the test.
Observe the transmissions of the EUT on the Operating Channel for duration greater than 30 minutes
after the Master Device is shut off.

7.3      Test data

(for 11n (HT40), 5310MHz)
1).Radar Type 1




Marker 1 : End of Burst                       : 19.92 sec
Marker 2 : End of Burst +10sec                : 29.92 sec




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                          Test report No.   : 10315698S-G
                                                                          Page              : 20 of 23
                                                                          Issued date       : October 28, 2014
                                                                          FCC ID            : W2Z-01000006



2).Master is shut off

(for 11n (HT40), 5310MHz)




Marker 1 : End of transmission                      : 24.96 sec


7.4      Test result

Test result: Pass

Date : September 22, 2014                  Test engineer : Tatsuya Arai




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                          Test report No.   : 10315698S-G
                                                                          Page              : 21 of 23
                                                                          Issued date       : October 28, 2014
                                                                          FCC ID            : W2Z-01000006




APPENDIX 1: Data of DFS test

                                       Parameter Data for Radar Type 5

  Trial                Number of    Pulse        Chirp     Pulse 1-to-2   Pulse 2-to-3   Starting Location
             Burst
 Number                 Pulses   Width (usec) Width (MHz) Spacing (usec) Spacing (usec) Within Interval (usec)
        1          1           1           52           8                                                   64
        1          2           2           94           7            1535                             680793
        1          3           3           67           8            1851          1146               452538
        1          4           1           50          18                                             791967
        1          5           3           82          14            1511          1064                 61930
        1          6           2           98          12            1125                               95345
        1          7           1           76           6                                             434356
        1          8           1           64          16                                             720311
        1          9           1           79          13                                             728383
        1         10           1           61          15                                             194181
        1         11           3           73          16            1638          1497               569650
        1         12           2           95          11            1811                             434312
        1         13           2           50          19            1491                             613325
        1         14           3           58          13            1254          1098               431579




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401


                                                                            Test report No.   : 10315698S-G
                                                                            Page              : 22 of 23
                                                                            Issued date       : October 28, 2014
                                                                            FCC ID            : W2Z-01000006



APPENDIX 2: Test instruments

EMI Test Equipment




The expiration date of the calibration is the end of the expired month.
As for some calibrations performed after the tested dates, those test equipment have been controlled by means of
an unbroken chains of calibrations.

All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or
international standards.
 Test Item:
  DFS: Dynamic Frequency Selection




UL Japan, Inc.
Shonan EMC Lab.
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa-ken, 259-1220 JAPAN
Telephone:       +81 463 50 6400
Facsimile:       +81 463 50 6401



Document Created: 2014-12-12 11:34:20
Document Modified: 2014-12-12 11:34:20

© 2025 FCC.report