                                                            FCC/IC - TEST REPORT



Report Number                                          : 68.910.18.0037.01                              Date of Issue:                    September 15, 2018


Model                                                  : DD7002B, DD7002

Product Type                                           : Connector Bridge

Applicant                                              : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd.

Address                                                : No.168 Shengguang Road, Luotuo, Zhenhai, Ningbo,

                                                            Zhejiang province, P.R.China 315202

Production Facility                                    : Ningbo Dooya Mechanic & Electronic Technology Co., Ltd.

Address                                                : No.168 Shengguang Road, Luotuo, Zhenhai, Ningbo,

                                                            Zhejiang province, P.R.China 315202




Test Result                                            :  Positive                     Negative



Total pages including
Appendices                                             : 18




TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in
ISO 17025.


TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of
the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
issued reports.


This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




EMC_SZ_FR_21.00 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                Page 1 of 18
                                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




1 Table of Contents
1     Table of Contents ................................................................................................................................................................... 2
2     Details about the Test Laboratory .......................................................................................................................................... 3
3     Description of the Equipment Under Test ............................................................................................................................. 4
4     Summary of Test Standards ................................................................................................................................................... 5
5     Summary of Test Results ....................................................................................................................................................... 6
6     General Remarks.................................................................................................................................................................... 7
7     Systems test configuration ..................................................................................................................................................... 8
8     Test Setups ............................................................................................................................................................................. 9
9     Test Methodology ................................................................................................................................................................ 10
    9.1       Conducted Emission.................................................................................................................................................... 10
    9.2       Radiated Emission ....................................................................................................................................................... 13
    9.3       Bandwidth Measurement ............................................................................................................................................ 15
    9.4       Deactivation Time ....................................................................................................................................................... 16
10    Test Equipment List ............................................................................................................................................................. 17
11    System Measurement Uncertainty ....................................................................................................................................... 18




EMC_SZ_FR_21.00 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                              Page 2 of 18
                                             Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




2 Details about the Test Laboratory
Details about the Test Laboratory

Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12&13, Zhiheng Wisdomland Business Park,
                      Nantou Checkpoint Road 2, Nanshan District,
                      Shenzhen City, 518052,
                      P. R. China

FCC Registration      514049
Number:

IC Registration       10320A-1
Number:

Telephone:            86 755 8828 6998
Fax:                  86 755 8828 5299




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




3 Description of the Equipment Under Test

Product/PMN:                      Connector Bridge

Model no./HVIN:                   DD7002B

FCC ID:                           VYYDD7002B

IC:                               21396-DD7002B

Options and accessories:          AC Adapter (Supplied by TUV SUD)
                                  Model: A1357
                                  Input: 100 – 240VAC, 50/60Hz, 0.4A
                                  Output: 5.1VDC, 2.1A

Rating:                           5VDC, 1000mA

RF Transmission                   433.92MHz
Frequency:

Modulation:                       ASK

Antenna Type:                     Integrated Antenna

Antenna Gain:                     1.2dBi

Description of the EUT:           The Equipment Under Test (EUT) is a Connector Bridge operated at
                                  433.92MHz




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




4 Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2017 Edition           Subpart C - Intentional Radiators
RSS-Gen Issue 5             General Requirements and Information for the Certification of
April 2018                  Radio Apparatus
RSS-210 Issue 9             RSS-210 — Licence-exempt Radio Apparatus (All Frequency
August 2016                 Bands): Category I Equipment

All the test methods were according to ANSI C63.10-2013.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




5 Summary of Test Results

                               Technical Requirements
   FCC Part 15 Subpart C, RSS-210 Issue 9
   Test Condition                                                                   Pages          Test Site             Test Result
   §15.207               RSS-GEN              Conducted emission                     10             Site 1                  Pass
                         A8.8                 AC power port
   §15.205, §15.209,     RSS-210              Radiated Emission,                       13            Site 1                 Pass
   15.35 (c)§15.231(b)   A.1.2                30MHz to 4.5GHz
   §15.231(c)            RSS-210              Bandwidth                                15            Site 1                 Pass
                         A.1.3                Measurement
   §15.231(a)(1)         RSS-210              Deactivation Time                        16            Site 1                 Pass
                         A.1.1(a)
   §15.203               RSS-Gen 6.8          Antenna requirement                       --       See Note 2                 Pass



Note 1: N/A=Not Applicable.
Note 2: The EUT uses an Integrated Antenna, which gain is 1.2dBi. In accordance to §15.203, It is
considered sufficiently to comply with the provisions of this section.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 6 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




6 General Remarks
Remarks

DD7002B and DD7002 are the same except model number. So EMC Full tests were applied on
DD7002B. DD7002 is deemed to fulfill relevant EMC requirement without further testing.

This submittal(s) (test report) is intended for FCC ID: VYYDD7002B, IC: 21396-DD7002B
complies with Section 15.205, 15.207, 15.209, 15.231 of the FCC Part 15, Subpart C Rules,
RSS-Gen Issue 5 and RSS-210 issue 9.

SUMMARY:

All tests according to the regulations cited on page 5 were

 - Performed

 - Not Performed

The Equipment Under Test

 - Fulfills the general approval requirements.

 - Does not fulfill the general approval requirements.


Sample Received Date:                         July 25, 2018

Testing Start Date:                           July 25, 2018

Testing End Date:                        September 6, 2018

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch


Reviewed by:                          Prepared by:                                     Tested by:




  _______________________                  _______________________                            _______________________
      Laurent Yuan                           Henry Chen                                             Louise Liu
   EMC Project Manager                    EMC Project Engineer                                   EMC Test Engineer




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01



7 Systems test configuration
Auxiliary Equipment Used during Test:

            DESCRIPTION            MANUFACTURER                    MODEL NO.(SHIELD)                     S/N(LENGTH)
                   --                          --                                --                           --




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01



8 Test Setups
8.1 Radiated test setups

Below 1GHz




Above 1GHz




8.2 Conducted RF test setups

                   Measuring receiver                           EUT



8.3 AC Power Line Conducted Emission test setups




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01



9 Test Methodology

9.1 Conducted Emission

Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through a Artificial Mains
      Network (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit

                         Frequency                        QP Limit                        AV Limit
                            MHz                            dBμV                            dBμV
                         0.150-0.500                       66-56*                          56-46*
                           0.500-5                           56                              46
                             5-30                            60                              50

*Decreasing linearly with logarithm of the frequency.




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




Conducted Emission Test 0.15MHz – 30MHz
EUT:                         Connector Bridge
M/N:                         DD7002B
Operating Condition:         TX
Test Specification:          Power Line, Live
Comment:                     AC120V/60Hz
Test Standard:               FCC Part 15 Subpart B
Temperature (°C):           23.5   Relative Humidity (%):             58.7       Atmospheric Pressure(mbar) :                   1009
             Level in dB礦




                               Frequency       MaxPeak       Average        Limit     Margin     Line     Corr.
                                 (MHz)          (dBµV)        (dBµV)       (dBµV)      (dB)               (dB)
                                  0.242000         39.60           ---       62.03      22.43    L1        10.2
                                  0.334000         34.16           ---       59.35      25.20    L1        10.2
                                  0.674000         37.19           ---       56.00      18.81    L1        10.2
                                  2.226000         30.52           ---       56.00      25.48    L1        10.3
                                  3.398000         28.39           ---       56.00      27.61    L1        10.3
                                  8.102000         33.02           ---       60.00      26.98    L1        10.5




EMC_SZ_FR_21.00 FCC                          TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 11 of 18
                                Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                     Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




Conducted Emission Test 0.15MHz – 30MHz
EUT:                         Connector Bridge
M/N:                         DD7002B
Operating Condition:         TX
Test Specification:          Power Line, Neutral
Comment:                     AC120V/60Hz
Test Standard:               FCC Part 15 Subpart B
Temperature (°C):           23.5   Relative Humidity (%):             58.7       Atmospheric Pressure(mbar) :                   1009
             Level in dB礦




                               Frequency       MaxPeak       Average        Limit     Margin     Line     Corr.
                                  (MHz)         (dBµV)        (dBµV)       (dBµV)      (dB)               (dB)
                                   0.182000        43.56           ---       64.39      20.84    N         10.3
                                   0.278000        39.76           ---       60.88      21.11    N         10.3
                                   0.514000        34.53           ---       56.00      21.47    N         10.4
                                   1.610000        26.15           ---       56.00      29.85    N         10.4
                                   7.678000        31.30           ---       60.00      28.70    N         10.7
                                 18.006000         30.60           ---       60.00      29.40    N         11.4




EMC_SZ_FR_21.00 FCC                          TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 12 of 18
                                Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                     Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




9.2 Radiated Emission

Test Method

   1: The EUT was place on a turn table which is 1.5m above ground plane for above 1GHz
   and 0.8m above ground for below 1GHz at 3 meter chamber room for test. The table was
   rotated 360 degrees to determine the position of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical polarizations
   of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:
   For Above 1GHz
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 1MHz, VBW≥RBW for peak measurement and VBW = 10Hz for average
       measurement, Sweep = auto, Detector function = peak, Trace = max hold.
   For Below 1GHz
   Use the following spectrum analyzer settings:
       Span = wide enough to capture the peak level of the in-band emission and all spurious
       RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function =
       peak, Trace = max hold.

Limit

According to §15.231 (b), the field strength of emissions from intentional radiators operated
under this section shall not exceed the following:

            Fundamental frequency                Field Strength of                     Field Strength of spurious
                                              Fundamental (Microvolts                    emissions ((Microvolts
                   (MHz)                              /meter)                                    /meter)
                  40.66-40.70                          2,250                                       225
                     70-130                            1,250                                       125
                    130-174                       1,250 to 3,370 *                             125 to 375 *
                    174-260                            3,750                                       375
                   260-470 √                     3,750 to 12, 500*                            375 to 1,250*
                  Above 470                            12,500                                     1,250




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01



Spurious radiated emissions for transmitter
According to C63.10, if the peak (or quasi-peak) measured value complies with the average limit, it is unnecessary to perform an
average measurement, so AV emission value did not show in below table if the peak value complies with average limit.

                                                              Radiated Emissions
    Value   Emissions            E-Field        Field
                                              Strength Average Net Field
                                                               Strength                      Limit        Margin             Emission
            Frequency            Polarity      at 3m    Factor  at 3m                                                         Type
               MHz                            dBµV/m     dB    dBµV/m                     dBµV/m
    Below 1GHz
     PK      433.920                 H          78.32          0.00          78.32         100.83          22.51           Fundamental
     AV      433.920                 H          78.32          0.00          78.32          80.83           2.51           Fundamental
     PK      433.920                 V          77.92          0.00          77.92         100.83          22.91           Fundamental
     AV      433.920                 V          77.92          0.00          77.92          80.83           2.91           Fundamental
     PK      867.864                 H          36.87          0.00          36.49          80.83          44.34             Spurious
     AV      867.864                 H          36.49          0.00          36.49          60.83          24.34             Spurious
     PK      867.918                 V          38.69          0.00          39.04          80.83          41.79             Spurious
     AV      867.918                 V          35.41          0.00          35.41          60.83          25.42             Spurious
    Above 1GHz
     PK      2603.54                 H          47.56          0.00          47.56            74           26.44              Spurious
     AV      2603.54                 H          47.56          0.00          47.56            54            6.44              Spurious
     PK      2603.54                 V          44.39          0.00          44.39            74           29.61              Spurious
     AV      2603.54                 V          44.39          0.00          44.39            54            9.61              Spurious

Remark:
1: AV Emission Level= PK Emission Level+20log(dutycycle)
2: Data of measurement within this frequency range shown “/” in the table above means the reading of emissions are attenuated more than 20db
below the permissible limits or the field strength is too small to be measured.
3: “*” means the emission(s) appear within the restrict bands shall follow the requirement of section 15.205.

Duty Cycle =100%
Duty Cycle Factor =20log (Duty Cycle) =0




EMC_SZ_FR_21.00 FCC                            TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 18
                                  Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                       Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




9.3 Bandwidth Measurement

Test Method

   1. Check the calibration of the measuring instrument using either an internal calibrator or a
      known signal from an external generator.
   2. Position the EUT without connection to measurement instrument. Turn on the EUT and
      connect it to measurement instrument. Then set it to any one convenient frequency within
      its operating range. Set a reference level on the measuring instrument equal to the
      highest peak value.
   3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the
      reference level. Record the frequency difference as the emission bandwidth.
   4. Repeat above procedures until all frequencies measured were complete.

Limit

The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70MHz and below 900MHz. For devices operating above 900MHz,
the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at
the points 20dB down from the modulated carrier.
The limit for the EUT = 0.25% * 433.92 MHz = 1084 kHz

Test Result

        Channel          20dB Bandwidth (KHz)                    99% bandwidth (KHz)                 Limit (KHz)
        1                81.620                                  77.279                              1084




EMC_SZ_FR_21.00 FCC                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 15 of 18
                         Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




9.4 Deactivation Time

Test Method

   1.   Place the EUT in the chamber and set it in transmitting mode.
   2.   Set center frequency of spectrum analyzer=operating frequency.
   3.   Set the spectrum analyzer as RBW=120 KHz, VBW=1MHz, Span=0Hz.
   4.   4. Repeat above procedures until all frequency measured was complete.

Limit

According to FCC Part 15.231 (a), the transmitter shall be complied the following requirements:
(√) (1) A manually operated transmitter shall employ a switch that will automatically deactivate
the transmitter within not more than 5 seconds of being released.
(2) A transmitter activated automatically shall cease transmission within 5 seconds after
activation.
(3) Periodic transmissions at regular predetermined intervals are not permitted. However, polling
or supervision transmissions, including data, to determine system integrity of transmitters used
in security or safety applications are allowed if the total duration of transmissions does not
exceed more than two seconds per hour for each transmitter. There is no limit on the number of
individual transmissions, provided the total transmission time does not exceed two seconds per
hour.

Test Result

        Channel                   Frequency                               Deactivation Time                 Result
        1                         433.92MHz                               3.3043 s                          Pass




                  Date:6.SEP.2018 17:04:22




EMC_SZ_FR_21.00 FCC                            TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 16 of 18
                                  Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                       Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




10 Test Equipment List
                                            List of Test Instruments

Radiated Emission Test
         DESCRIPTION              MANUFACTURER                    MODEL NO.               SERIAL NO.             CAL. DUE DATE
        EMI Test Receiver         Rohde & Schwarz                  ESR 26                   101269                  2019-7-6
  Trilog Super Broadband Test
                                      Schwarzbeck                 VULB 9163                     707                   2019-6-28
            Antenna
          Horn Antenna             Rohde & Schwarz                    HF907                  102294                   2019-6-28
         Pre-amplifier             Rohde & Schwarz                   SCU 18                102230                         2019-7-6
       Signal Generator            Rohde & Schwarz                   SMY01               839369/005                       2019-7-6
          Attenuator                   Agilent                       8491A               MY39264334                       2019-7-6
   3m Semi-anechoic chamber             TDK                          9X6X6                   ----                         2020-7-7

Conducted Emission Test
      DESCRIPTION               MANUFACTURER                     MODEL NO.               SERIAL NO.              CAL. DUE DATE
     EMI Test Receiver          Rohde & Schwarz                     ESR 3                  101782                   2019-7-6
           LISN                 Rohde & Schwarz                    ENV4200                 100249                   2019-7-6
           LISN                 Rohde & Schwarz                    ENV432                  101318                   2019-7-6
           LISN                 Rohde & Schwarz                    ENV216                  100326                   2019-7-6
           ISN                  Rohde & Schwarz                     ENY81                  100177                   2019-7-6
           ISN                  Rohde & Schwarz                   ENY81-CA6                101664                   2019-7-6
                                                                 TK9420(VT94
     High Voltage Probe          Rohde & Schwarz                                           9420-584                   2019-6-30
                                                                     20)
      RF Current Probe           Rohde & Schwarz                    EZ-17                   100816                    2019-6-30
         Attenuator             Shanghai Huaxiang                  TS2-26-3               080928189                    2019-7-6




EMC_SZ_FR_21.00 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 17 of 18
                          Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.910.18.0037.01




11 System Measurement Uncertainty
For a 95% confidence level, the measurement expanded uncertainties for defined systems, in accordance with
the recommendations of ISO 17025 were:

                                            System Measurement Uncertainty
   Test Items                                                                                           Extended Uncertainty
                                                                                                         Horizontal: 4.91dB;
   Uncertainty for Radiated Emission in 3m chamber 30MHz-1000MHz
                                                                                                          Vertical: 4.89dB;
                                                                                                         Horizontal: 4.80dB;
   Uncertainty for Radiated Spurious Emission 25MHz-3000MHz
                                                                                                          Vertical: 4.87dB;
                                                                                                         Horizontal: 4.59dB;
   Uncertainty for Radiated Spurious Emission 3000MHz-18000MHz
                                                                                                          Vertical: 4.58dB;
                                                                                                         Horizontal: 5.05dB;
   Uncertainty for Radiated Spurious Emission 18000MHz-40000MHz
                                                                                                          Vertical: 5.04dB;
   Uncertainty for Conducted Emission 150kHz-30MHz (for test using AMN ENV432
                                                                                                                3.21dB
   or ENV4200)




EMC_SZ_FR_21.00 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 18 of 18
                           Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2014-03-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2018-11-01 10:11:31
Document Modified: 2018-11-01 10:11:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC