RF exposure report

FCC ID: VYYDD7002B

RF Exposure Info

Download: PDF
FCCID_4082317

Report Number: 68.910.18.0036.01A




                                         RF exposure Estimation for DD7002B

           Introduction
           DD7002B (FCC ID: VYYDD7002B) is a Connector Bridge operating at 433.91MHz and
           433.92MHz.

1.         Limit and Guidelines on Exposure to Electromagnetic Fields

           According to 4.3 General SAR test exclusion guidance of KDB 447498 RF Exposure, no SAR
           required if power is lower than the flowing threshold:
           The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
           distances ≤ 50 mm are determined by:
            [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
           mm)]
            [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
                • f(GHz) is the RF channel transmit frequency in GHz
                • Power and distance are rounded to the nearest mW and mm before calculation25
                • The result is rounded to one decimal place for comparison
                • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

           The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
           and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test
           separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.3 is applied to
           determine SAR test exclusion.

2.         Calculation method

           [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance,
           mm)] ·[√f(GHz)] ≤ 3.0

           According to ANSI C63.10-2013 (9.5 Equations to calculate EIRP),




                                               TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755
                                                                           8828 5299


Report Number: 68.910.18.0036.01A


For 433.91MHz.
         Field Strength (EMeas):                                                                                                  85.87 (dBuV/m)
                                                                                                                                  (f=433.91 MHz)
         Measurement Distance(dMeas):                                                                                             3 (m)
         Equivalent Isotropically Radiated Power(EIRP):                                                                           0.118 (mW)



           Radiated Power + tune up tolerance = 0.118mW
           Distance = 5 mm
           f = 433.91MHz

           [0.118/5] * SQRT(0.43391) =0.0155
           0.0155 ≤ 3.0
           Therefore, excluded from SAR testing.

For 433.92MHz.
         Field Strength (EMeas):                                                                                                  78.32 (dBuV/m)
                                                                                                                                  (f=433.92 MHz)
         Measurement Distance(dMeas):                                                                                             3 (m)
         Equivalent Isotropically Radiated Power(EIRP):                                                                           0.0207 (mW)



           Radiated Power + tune up tolerance = 0.0207mW
           Distance = 5 mm
           f = 433.92MHz

           [0.0207/5] * SQRT(0.43392) =0.0027
           0.0027 ≤ 3.0
           Therefore, excluded from SAR testing.


TUV SUD China, Shenzhen Branch

Reviewed by:                                                                                 Prepared By:




Laurent Yuan/ EMC Project Manager                                                        Henry Chen/EMC Project Engineer

Date: 2018-09-26                                                                                Date: 2018-09-26