                                          RF exposure Estimation for DD1149

           Introduction
           DD1149 (FCC ID: VYYDD1149) is a Transmitter operating at 433.925MHz.

1.         Limit and Guidelines on Exposure to Electromagnetic Fields

           According to 4.3 General SAR test exclusion guidance of KDB 447498 RF Exposure, no SAR
           required if power is lower than the flowing threshold:
           The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
           distances ≤ 50 mm are determined by:
            [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]
            [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
                • f(GHz) is the RF channel transmit frequency in GHz
                • Power and distance are rounded to the nearest mW and mm before calculation25
                • The result is rounded to one decimal place for comparison
                • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

           The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
           and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test
           separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.3 is applied to
           determine SAR test exclusion.

2.         Calculation method

           [(max. power of` channel, including tune-up tolerance, mW)/(min. test separation distance,
           mm)] ·[√f(GHz)] ≤ 3.0

           Power of` channel = 75.33dBuV/m=0.01mW
           Distance = 5 mm
           f = 0.433925 GHz

           [0.01/5] * SQRT(0.433925) =0.0013
           0.0013≤ 3.0
           Therefore, excluded from SAR testing.


TUV SUD China, Shenzhen Branch

Reviewed by:                                                                                 Prepared By:




Phoebe Hu/ EMC Project Manager                                                       Aaron Lai/EMC Project Engineer
Date: 2016-06-27                                                                           Date: 2016-06-27




                                               TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch