User manual

FCC ID: VYY-DM35LE-S

Users Manual

Download: PDF
FCCID_2824953

                       Note:When the battery power is low,you can hear the alarm ten "beep" every time the
                       motor runs. It indicates the battery needs to be charged. Then plug in the charger with
                       red light.The light turns green when the battery is fully charged.


                  Signal wire




Tubular Motor-
  DM35LE/S       Functional featuresᱶ                                                                     85


                    Integrated radio control                Jogging&tilt function


 Specification      Setting up+add emitter+delete emitter
                    Motor direction setting option
                    Resistance stop function
                                                            Set electronic limit
                                                            Set /delete the third limit position
                                                            Low standby power
                                                                                                         -10


                                                                                                    Operating
                                                                                                   temperature

                 Parameter
                                                                                                                 Rechargeable Description                   The motor has a built-in battery,using the charger to
                                        Type                                         DM35LE/S                                                               recharge.You can also use solar panels to charge;when
                                                                                                                                                            the battery is low, insert thecharge,charger light shows
                                  Rated Torque(N.m)                                    3N.m
                                                                                                                                                            red light.batteries isfull when the red light turns to green.

    (A-OO)                        Rated speed(RPM)                                      28RPM

                                  Rated Voltage(V)                                      12V

                                Emission frequency(MHz)                             433.925MHz




                                                                                                                 1. Please charge the battery and make sure it is fully charged before the first use
                                                                                                                 2. Don’t operate motors wheuin low wltage alarm:
                                                                                                                    ᰷Motor stop running When the supply voltage is lower than 7 v, and it will restart
                                                                                                                    again when the voltage is greater than 7.5V
                                                                                                                    ᰸If the voltage is less than 10v, the motor will alarm for 10 times to prompt it needs
                                                                                                                    to be charged every timewhen the motor is working.
                                                                                                                 3. Optratingᱶ
                                                                                                                    ᰷The valid interval of the emitter button is 10s,the emitter will quit the set after 10s
                                                                                                                    ᰸The motor will run or beep for hint,please do the next step after the hint.
                                                                                                                 4. Set limit positionᱶ
                                                                                                                    ᰷After the up limit and down limit setting,and the up limit down limit and third limit
                                                                                                                    position are at the same location
                                                                                                                    ᰸After limit setting,with power and memory function;
                                                                                                                    ᰹Into the match-code status 2 minutes later, it will quit out the setting limits status
                                                                                                                    automatically
                                                                                                                    ᰺It will delete every memory and restore the factory settings
                                                                                                                 5. When the motor running without any operation, the maximum running time is 6
                                                                                                                    minutes,it will stop automatically
                                                                                                                 6. If the emitterlost,please set up again with new emitter



Document Created: 2019-09-29 13:46:45
Document Modified: 2019-09-29 13:46:45

© 2024 FCC.report