Test Report

FCC ID: VYY-1662

Test Report

Download: PDF
FCCID_3811339

                                             TEST REPORT
  Reference No.....................      :   WTN18S03106230W
  FCC ID..............................   :   VYY-1662
  Applicant..........................    :   Ningbo Dooya Mechanic & Electronic Technology Co.,Ltd.
                                             NO.168 shengguang road Luotuo street Zhenhai district Ningbo,
  Address............................    :
                                             P.R.China
  Manufacturer....................       :   Ningbo Dooya Mechanic & Electronic Technology Co.,Ltd.
                                             NO.168 shengguang road Luotuo street Zhenhai district Ningbo,
  Address ...................            :
                                             P.R.China
  Product Name....................       :   Transmitter

  Model No. ....................         :   DC1662G, DC1662

  Standards.........................     :   FCC CFR47 Part 15 Section 15.231: 2017

  Date of Receipt sample....             :   2018-03-26

  Date of Test......................     :   2018-03-27-2018-03-30

  Date of Issue....................      :   2018-04-02
  Test Result.......................     :   Pass


  Remarks:
  The results shown in this test report refer only to the sample(s) tested, this test report cannot be
  reproduced, except in full, without prior written permission of the company. The report would be invalid
  without specific stamp of test institute and the signatures of compiler and approver.

                                                 Prepared By:
                                    Waltek Services (Shenzhen) Co., Ltd.
       Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                              Guangdong, China
                                            Tel :+86-755-83551033
                                            Fax:+86-755-83552400

          Compiled by:                                                     Approved by:




          Jack Wen /Test Engineer                                          Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                              Page 1 of 20


Reference No.: WTN18S03106230W                    Page 2 of 20



 1      Laboratories Introduction
     Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory
with multi-year product testing and certification experience, established strictly in accordance with ISO/IEC
17025 requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation) member.
A2LA (American Association for Laboratory Accreditation) of USA, Meanwhile, Waltek has got recognition
as registration and accreditation laboratory from EMSD (Electrical and Mechanical Services Department),
and American Energy star, FCC(The Federal Communications Commission), CEC(California energy
efficiency), IC(Industry Canada). It’s the strategic partner and data recognition laboratory of international
authoritative organizations, such as Intertek(ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




     Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party
testing laboratory in China. Our test capability covered four large fields: safety test. ElectroMagnetic
Compatibility(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice
international test organization, we still keep the scientific and rigorous work attitude to help each client
satisfy the international standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                    Page 3 of 20




1.1 Test Facility
      A. Accreditations for Conformity Assessment (International)
      Country/Region        Accreditation Body           Scope                Note
      USA                                                FCC ID \ DOC \ VOC   1
      Canada                                             IC ID \ VOC          2
      Japan                                              MIC-T \ MIC-R        -
                            A2LA
      Europe                                             EMCD \ RED           -
                            (Certificate No.: 4243.01)
      Taiwan                                             NCC                  -
      Hong Kong                                          OFCA                 -
      Australia                                          RCM                  -
      India                                              WPC                  -
      Thailand              International Services       NTC                  -
      Singapore                                          IDA                  -
      Note:
      1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
      2.   IC Canada Registration No.: 7760A

      B.TCBs and Notify Bodies Recognized Testing Laboratory.


      Recognized Testing Laboratory of …                 Notify body number
      TUV Rheinland
      Intertek
                                                         Optional.
      TUV SUD
      SGS
      Phoenix Testlab GmbH                               0700
      Element Materials Technology Warwick Ltd           0891
      Timco Engineering, Inc.                            1177
      Eurofins Product Service GmbH                      0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                                                       Page 4 of 20



    2       Contents
                                                                                                                                                                 Page
1       COVER PAGE ...................................................................................................................................... 1
1       LABORATORIES INTRODUCTION ............................................................................................................ 2
        1.1          TEST FACILITY ....................................................................................................................................... 3
2       CONTENTS ....................................................................................................................................................... 4
3       REVISION HISTORY ....................................................................................................................................... 5
4       TEST SUMMARY ............................................................................................................................................. 6
5       GENERAL INFORMATION ............................................................................................................................. 7
        5.1          GENERAL DESCRIPTION OF E.U.T........................................................................................................ 7
        5.2          DETAILS OF E.U.T. ................................................................................................................................ 7
        5.3          TEST MODE ........................................................................................................................................... 7
6       EQUIPMENT USED DURING TEST ............................................................................................................. 8
        6.1          EQUIPMENTS LIST ................................................................................................................................. 8
        6.2          MEASUREMENT UNCERTAINTY.............................................................................................................. 9
        6.3          TEST EQUIPMENT CALIBRATION ........................................................................................................... 9
7       RADIATED SPURIOUS EMISSIONS .......................................................................................................... 10
        7.1          EUT OPERATION ................................................................................................................................. 10
        7.2          TEST SETUP ........................................................................................................................................ 11
        7.3          SPECTRUM ANALYZER SETUP ............................................................................................................ 12
        7.4          TEST PROCEDURE............................................................................................................................... 13
        7.5          SUMMARY OF TEST RESULTS ............................................................................................................. 14
8       PERIODIC OPERATION ............................................................................................................................... 15
9       EMISSION BANDWIDTH .............................................................................................................................. 18
        9.1          TEST PROCEDURE............................................................................................................................... 18
        9.2          TEST RESULT ...................................................................................................................................... 18
10      ANTENNA REQUIREMENT ......................................................................................................................... 19
11      PHOTOGRAPHS – MODEL DC1662G ....................................................................................................... 20




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


 Reference No.: WTN18S03106230W                        Page 5 of 20



   3    Revision History
                        Date of
                                                           Date of
  Test report #         Receipt        Date of Test                   Purpose    Comment   Approved
                                                            Issue
                        sample

                                       2018-03-27 to
WTN18S03106230W       2018-03-26                         2018-04-02   Original      -        Valid
                                        2018-03-30




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


Reference No.: WTN18S03106230W             Page 6 of 20



 4     Test Summary
                   Test Items                   Test Requirement   Result

                                                    15.205(a)
          Radiated Spurious Emissions                15.209        PASS
                                                    15.231(a)

                Periodic Operation                  15.231(a)      PASS


               Emission Bandwidth                   15.231(c)      PASS


              Antenna Requirement                     15.203       PASS

         Maximum Permissible Exposure
                                                   1.1307(b)(1)    PASS
       (Exposure of Humans to RF Fields)




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                    Page 7 of 20



 5     General Information
5.1 General Description of E.U.T.
     Product Name                 : Transmitter
     Model No.                    : DC1662G, DC1662
                                  : Only the model names are different, the model: DC1662G is the
     Model Difference
                                  tested sample.
     Hardware version             : V1.0
     Software version             : V1.0
     Type of Modulation           : FSK
     Frequency Range              : 433.92 MHz
     The Lowest Oscillator        : 433.92MHz
     Antenna installation         : PCB Printed Antenna

5.2 Details of E.U.T.
     Technical Data               : DC 3V by CR2450


5.3 Test Mode
      All test mode(s) and condition(s) mentioned were considered and evaluated respectively by
      performing full tests, the worst data were recorded and reported.

          Test mode            Lower channel        Middle channel       Upper channel
          Transmitting                 /               433.92MHz                 /




 Waltek Services (Shenzhen) Co.,Ltd.
 http://www.waltek.com.cn


        Reference No.: WTN18S03106230W                     Page 8 of 20



         6       Equipment Used during Test
        6.1 Equipments List
3m Semi-anechoic Chamber for Radiation Emissions Test site 1#
                                                                                       Last
                                                                                                    Calibration
 Item          Equipment          Manufacturer       Model No.       Serial No.     Calibration
                                                                                                     Due Date
                                                                                       Date
  1           EMC Analyzer           Agilent           E7405A       MY45114943     Sep.15,2017     Sep.14,2018
  2      Active Loop Antenna      Beijing Dazhi      ZN30900A              -       Sep.15,2017     Sep.14,2018
          Trilog Broadband
  3                             SCHWARZBECK          VULB9163             336      Apr.19,2017     Apr.18,2018
                Antenna
            Coaxial Cable
  4                                    Top          TYPE16(13M)            -       Sep.15,2017     Sep.14,2018
             (below 1GHz)
          Broad-band Horn
  5                             SCHWARZBECK         BBHA 9120 D           667      Apr.19,2017     Apr.18,2018
                Antenna
          Broad-band Horn
  6                             SCHWARZBECK          BBHA 9170            335      Apr.19,2017     Apr.18,2018
                Antenna
               Broadband         COMPLIANCE
  7                                                  PAP-1G18             2004     Mar.17,2018     Mar.16,2019
              Preamplifier        DIRECTION
            Coaxial Cable
  8                                    Top          1GHz-25GHz      EW02014-7      Apr.10,2017     Apr.09,2018
            (above 1GHz)
3m Semi-anechoic Chamber for Radiation Emissions Test site 2#
                                                                                       Last
                                                                                                    Calibration
 Item          Equipment          Manufacturer       Model No.       Serial No     Calibration
                                                                                                     Due Date
                                                                                       Date
  1           Test Receiver           R&S               ESCI           101296      Apr.13, 2017    Apr.12, 2018
             Trilog Broadband
  2                             SCHWARZBECK          VULB9160        9160-3325     Apr.09, 2017    Apr.08, 2018
                  Antenna
                                  Compliance
  3             Amplifier          pirection          PAP-0203         22024       Sep.15,2017     Sep.14,2018
                                  systems inc
  4               Cable         HUBER+SUHNER            CBL2           525178      Apr.13, 2017    Apr.12, 2018
RF Conducted Testing
                                                                                       Last
                                                                                                    Calibration
 Item          Equipment          Manufacturer       Model No.       Serial No.     Calibration
                                                                                                     Due Date
                                                                                       Date
              EMC Analyzer
  1.                                 Agilent           E7405A       MY45114943     Sep.15,2017     Sep.14,2018
              (9k~26.5GHz)
          Spectrum Analyzer
  2.                                  R&S               FSL6           100959      Sep.12, 2017    Sep.11, 2018
                (9k-6GHz)
             Signal Analyzer
  3.                                 Agilent           N9010A       MY50520207     Apr.29, 2017    Apr.28, 2018
              (9k~26.5GHz)
              Coaxial Cable
  4.                                    /                 /                /       Sep.12,2017     Sep.11,2018
              (10Hz-30GHz)
  5.      Antenna Connector*            /                 /                /       Sep.12,2017     Sep.11,2018
        ”*”: The temporary antenna connector is soldered on the PCB board in order to perform conducted tests

         Waltek Services (Shenzhen) Co.,Ltd.
         http://www.waltek.com.cn


Reference No.: WTN18S03106230W                       Page 9 of 20


  and this temporary antenna connector is listed in the equipment list.




6.2 Measurement Uncertainty

              Test Item               Frequency Range               Uncertainty          Note

        Conducted Emissions             150kHz~30MHz                 ±3.64dB              (1)

          Radiated Spurious            30MHz~1000MHz                 ±5.03dB              (1)
             Emissions                 1000M~5000MHz                 ± 5.47 dB            (1)
     (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95%
       confidence level using a coverage factor of k=2.

6.3 Test Equipment Calibration
      All the test equipments used are valid and calibrated by CEPREI Certification Body that
      address is No.110 Dongguan Zhuang RD. Guangzhou, P.R.China.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                         Page 10 of 20



 7     Radiated Spurious Emissions
      Test Requirement:                    FCC Part15 Paragraph 15.231(a)
      Test Method:                         ANSI C63.10:2013
      Test Result:                         PASS
      Measurement Distance:                3m
      Limit:
                                                                    Field Strength   Field Strength
          Fundamental        Field Strength        Field Strength
                                                                     of Spurious      of Spurious
           Frequency        of Fundamental        of Fundamental
                                                                      Emission         Emission
             (MHz)               (uV/m)              (dBuV/m)
                                                                        (uV/m)         (dBuV/m)
          44.66-40.70               2250                67                225               47
               70-130               1250                62                125               42
               130-174        1250 to 3750          62 to 71.48        125 to 375     42 to 51.48
               174-260              3750              71.48               375            51.48
               260-470       3750 to 12500        71.48 to 81.94       375 to 1250   51.48 to 61.94
           Above 470                12500             81.94               1250           61.94
       aa** linear interpolations

7.1 EUT Operation

     Operating Environment :
     Temperature:                      23.5 °C
     Humidity:                         51.1 % RH
     Atmospheric Pressure:             101.2kPa
     EUT Operation :
     The test was performed in transmitting mode, the test data were shown in the report.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                    Page 11 of 20



7.2 Test Setup
      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the
      setup accordance with the ANSI C63.10.

      The test setup for emission measurement below 30MHz.




              Semi-anechoic 3m Chamber
              Turn Table From 0°to 360°




                                                        3m
                              EUT


                           Turn Table
           0.8m




                                  PC              Spectrum            AMP          Combining
                                System            Analyzer                          Network



      The test setup for emission measurement from 30 MHz to 1 GHz.



              Semi-anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
              Turn Table From 0°to 360°
                                                        3m


                              EUT


           0.8m             Turn Table




                                 PC              Spectrum             AMP         Combining
                               System            Analyzer                          Network




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                             Page 12 of 20


      The test setup for emission measurement above 1 GHz.




              Anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
             Turn Table From 0°to 360°
                                                                   3m
                                EUT



           1.5m

                             Turn Table
                                                               Absorbers




                                  PC                      Spectrum                    AMP      Combining
                                System                    Analyzer                              Network



7.3 Spectrum Analyzer Setup
          Below 30MHz
                         Sweep Speed .............................................. Auto
                         IF Bandwidth ................................................ 10kHz
                         Video Bandwidth.......................................... 10kHz

                         Resolution Bandwidth.................................. 10kHz

          30MHz ~ 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ..................................................... PK
                         Resolution Bandwidth .................................. 100kHz
                         Video Bandwidth.......................................... 300kHz

          Above 1GHz
                         Sweep Speed .............................................. Auto
                         Detector ..................................................... PK
                         Resolution Bandwidth .................................. 1MHz
                         Video Bandwidth.......................................... 3MHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                       Page 13 of 20



7.4 Test Procedure

      1. The EUT is placed on a turntable. For below 1GHz, the EUT is 0.8m above ground plane;
      For above1GHz, the EUT is 1.5m above ground plane.
      2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
      level.
      3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
      maximum emissions. The spectrum was investigated from the lowest radio frequency signal
      generated in the device, without going below 9 kHz, up to the tenth harmonic of the highest
      fundamental frequency or to 40 GHz, whichever is lower.
      4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      5. And also, each emission was to be maximized by changing the polarization of receiving antenna
      both horizontal and vertical.
      6. Repeat above procedures until the measurements for all frequencies are complete.
      7. The radiation measurements are tested under 3-axes(X,Y,Z) position(X denotes lying on the table,
      Y denotes side stand and Z denotes vertical stand), After pre-test, It was found that the worse
      radiation emission was get at the X position. So the data shown was the X position only.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                         Page 14 of 20



7.5 Summary of Test Results

      Test Frequency : 30MHz ~ 5GHz

                                                                                          FCC Part
                Receiver     Turn        RX Antenna
                                                             Corrected   Corrected    15.231/15.209/205
  Frequency     Reading      table
                                                              Factor     Amplitude
                 (PK)        Angle      Height    Polar                                Limit      Margin
                                                                           (PK)

                                                                                      (dBμV/
     (MHz)       (dBμV)     Degree       (m)       (H/V)      (dB/m)     (dBμV/m)                  (dB)
                                                                                        m)

    433.92        84.89       336        1.1           H       -7.31      77.58       100.82      -23.24

    433.92        86.22        28        1.4           V       -7.31      78.91       100.82      -21.91

    867.84        55.78       344        1.9           H        0.04      55.82        80.82      -25.00

    867.84        53.91       158        1.7           V        0.04      53.95        80.82      -26.87

    1816.80       56.47       139        1.7           H       -14.38     40.09        74.00      -33.91

    1816.80       53.73       355        1.3           V       -14.38     37.35        74.00      -36.65

    2725.20       56.64        38        2.0           H       -12.87     41.77        74.00      -32.23

    2725.20       57.99       256        1.3           V       -12.87     43.12        74.00      -30.88


      AV = Peak +20Log10(duty cycle) =PK+(-7.52) [refer to section 8 for more detail]
                                                                           FCC Part 15.231/209/205
                                RX         Duty cycle       Calculated
   Frequency         PK
                              Antenna       Factor             AV
                                                                             Limit             Margin
                               Polar
     (MHz)       (dBμV/m)       (H/V)          (dB)          (dBμV/m)      (dBμV/m)             (dB)

     433.92        77.58            H          -7.52           70.06         80.82             -10.76

     433.92        78.91            V          -7.52           71.39         80.82             -9.43

     867.84        55.82            H          -7.52           48.30         60.82             -12.52

     867.84        53.95            V          -7.52           46.43         60.82             -14.39

    1816.80        40.09            H          -7.52           32.57         54.00             -21.43

    1816.80        37.35            V          -7.52           29.83         54.00             -24.17

    2725.20        41.77            H          -7.52           34.25         54.00             -19.75

    2725.20        43.12            V          -7.52           35.60         54.00             -18.40




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                        Page 15 of 20



 8     Periodic Operation
      The duty cycle was determined by the following equation:
      To calculate the actual field intensity, The duty cycle correction factor in decibel is needed for later
      use and can be obtained from following conversion


      Duty Cycle(%)=Total On interval in a complete pulse train/ Length of a complete pulse train * %
      Duty Cycle Correction Factor(dB)=20 * Log10(Duty Cycle(%))


                 Total transmission time(ms)                     4.81+0.33*21+0.69*19=24.85

        Length of a complete transmission period(ms)                         59.08

                        Duty Cycle(%)                                        42.06

               Duty Cycle Correction Factor(dB)                               -7.52


      Refer to the duty cycle plot (as below),This device meets the FCC requirement.
      Length of a complete pulse train:
      Remark: FCC part15.35(c) required that when the radiated emission limits are expressed in terms of
      the average value of the emission, and pulsed operation is employed, the measurement field
      strength shall be determined by averaging over one complete pulse train, including blanking
      intervals, as long as the pulse train does not exceed 0.1 seconds.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W          Page 16 of 20



                                      Pulse 1




                                      Pulse 2




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                        Page 17 of 20



                                                  Pulse 3




FCC Part15.231(a)(1) A manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.
(2)A transmitter activated automatically shall cease transmission within 5 seconds after activation.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                       Page 18 of 20



 9     Emission Bandwidth
      Test Requirement:                 FCC Part15.231(c)
      Test Method:                      FCC Part15.231(c)
      Limit                             The bandwidth of the emission shall be no wider than 0.25% of the
                                        center frequency for devices operating above 70 MHz and below
                                        900 MHz. For devices operating above 900 MHz, the emission
                                         shall be no wider than 0.5% of the center frequency.

9.1 Test Procedure

      1. The transmitter output (antenna port) was connected to the spectrum analyzer.EUT and its
         simulators are placed on a table, let EUT working in test mode, then test it.
      2. The bandwidth of the fundamental frequency was measure by spectrum analyser with 30kHz
        RBW and 100kHz VBW. The 20 dB bandwidth was recorded.

9.2 Test Result
               Frequency      20 dB Bandwidth              Limit
                                                                                   Result
                 (MHz)         Emission(KHz)               (KHz)
                433.92             126.70                1084.80                    Pass
              Limit=Center Frequency*0.25%
              Test Plot




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                          Page 19 of 20



 10 Antenna Requirement
      According to the FCC Part 15 Paragraph 15.203, an intentional radiator shall be designed to ensure
      that no antenna other than that furnished by the responsible party shall be used with the device. The
      use of a permanently attached antenna to the intentional radiator shall be considered sufficient to
      comply with the provisions of this section. This product use a PCB printed antenna, it only apply to
      this model, fulfill the requirement of this section.




                                                                                              ANT




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTN18S03106230W                    Page 20 of 20



 11 Photographs – Model DC1662G
Please refer to the file Please refer to the file “DC1662G_Tsup Photos”, “DC1662G_Ext Photos” and
“DC1662G_Int Photos” .


                                      ======End of Report======




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn



Document Created: 2018-04-10 13:15:52
Document Modified: 2018-04-10 13:15:52

© 2024 FCC.report