MPE

FCC ID: VYTLP-9287C

RF Exposure Info

Download: PDF
FCCID_1231095

            程智科技股份有限公司
            Compliance Certification Services Inc.


RADIO FREQUENCY EXPOSURE
LIMIT
According to §15.247(i), systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy levels in excess of the
Commission's guidelines. See § 1.1307(b)(1) of this chapter.
EUT Specification
EUT                             High Power 802.11g Wireless USB Adapter
                                    WLAN: 2.412GHz ~ 2.462GHz
 Frequency band                     WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz
(Operating)                         WLAN: 5.745GHz ~ 5.825GHz
                                    Others
                                    Portable (<20cm separation)
Device category                     Mobile (>20cm separation)
                                    Others
                                    Occupational/Controlled exposure (S = 5mW/cm2)
Exposure classification             General Population/Uncontrolled exposure
                                   (S=1mW/cm2)
                                    Single antenna
                                    Multiple antennas
Antenna diversity                       Tx diversity
                                        Rx diversity
                                        Tx/Rx diversity
                                IEEE 802.11b: 9.15 dBm (8.22mW)
Max. output power
                                IEEE 802.11g: 17.18 dBm (52.24mW)
                                PIFA Antenna / Gain: 13.41dBi (Numeric gain: 21.92)
Antenna gain (Max)
                                Dipole Antenna / Gain: 5dBi (Numeric gain: 3.16)
                                    MPE Evaluation
Evaluation applied                  SAR Evaluation
                                    N/A
Remark:
1. The maximum output power is 17.18dBm (52.24mW) at 2437MHz (with 21.92
   numeric antenna gain.)
   DTS device is not subject to routine RF evaluation; MPE estimate is used to justify
   the compliance.
2. For mobile or fixed location transmitters, no SAR consideration applied. The
   maximum power density is 1.0 mW/cm2 even if the calculation indicates that the
   power density would be larger.

TEST RESULTS
No non-compliance noted.


            程智科技股份有限公司
              Compliance Certification Services Inc.

Calculation

              30 × P × G          E2
Given    E=               & S=
                  d              3770
         Where E = Field strength in Volts / meter
                 P = Power in Watts
                 G = Numeric antenna gain
                 d = Distance in meters
                 S = Power density in milliwatts / square centimeter

Combining equations and re-arranging the terms to express the distance as a function of the
remaining variables yields:
              30 × P × G
         S=
               3770d 2

Changing to units of mW and cm, using:
         P (mW) = P (W) / 1000 and
         d (cm) = d(m) / 100
Yields
              30 × (P / 1000 ) × G            P×G
         S=                        = 0.0796 ×       Equation 1
               3770 × (d / 100 )
                                 2
                                               d2

         Where d = Distance in cm
                  P = Power in mW
                  G = Numeric antenna gain
                  S = Power density in mW / cm2
Maximum Permissible Exposure
EUT output power = 52.24mW
Numeric Antenna gain = 21.92
Substituting the MPE safe distance using d = 20 cm into Equation 1:
Yields
    S = 0.000199 × P × G
Where P = Power in mW
         G = Numeric antenna gain
         S = Power density in mW / cm2
Æ Power density = 0.228 mW / cm2
(For mobile or fixed location transmitters, the maximum power density is 1.0 mW/cm2 even if the
calculation indicates that the power density would be larger.)



Document Created: 2010-01-18 14:30:18
Document Modified: 2010-01-18 14:30:18

© 2025 FCC.report