MPE

FCC ID: VYTLP-9186-001

RF Exposure Info

Download: PDF
FCCID_904135

                                                    FCC ID: VYTLP-9186-001




   RF Exposure Evaluation
                            of
  E.U.T.      : Wireless AP Router IEEE 802.11b/g

  FCC ID.     : VYTLP-9186-001

  MODEL       : LP-9186


                            for

APPLICANT     : Loopcomm Technology, Inc.

ADDRESS       : 1F, No. 114, Lian Chen Rd., Chung-Ho City,

               Taipei Hsien, 235, Taiwan R.O.C.




                         Prepared by


        ELECTRONICS TESTING CENTER, TAIWAN
       NO. 34, LIN 5, DING FU TSUN, LINKOU HSIANG,
                TAIPEI HSIEN, TAIWAN, R.O.C.
        Tel:(02)26023052             Fax:(02)26010910
         http://www.etc.org.tw ; e-mail: r00@etc.org.tw
              Report Number : 08-01-RBF-046-MPE


                                                                  FCC ID: VYTLP-9186-001




Product Information:
Type of EUT: Wireless AP Router IEEE 802.11b/g
FCC ID:       VYTLP-9186-001
Manufacturer: Loopcomm Technology, Inc.
Model:        LP-9186
Description: 1. Standard IEEE 802.11 b/g
              2. Frequency Range: 2.40GHz~2.4835GHz
              3. Operating Frequency / Channel: 2.412 ~ 2.462GHz (Canada, FCC) / 11 Channels
              4. Modulation Technique:
              Orthogonal frequency division multiplexing (OFDM)
              Direct Sequence Spread Spectrum (CCK, DQPSK, DBPSK)


Maximum conducted output power (measured):             28.01 dBm or 632.411 mW


The following table lists the provided authorized antennas:
     Model                    Antenna Type                      Antenna Gain
                                                              (dBi)        Numeric
F1B_5DB316-52                 Rod antenna                      5.22           3.32



Below is an example of the RF Exposure Statement:


IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements,
the antenna(s) used for this transmitter must be installed to provide a separation
distance of at least 20 cm from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter. No change to the antenna or the
device is permitted. Any change to the antenna or the device could result in the
device exceeding the RF exposure requirements and void user’s authority to operate
the device.


                                                                                      FCC ID: VYTLP-9186-001




Relative Requirement for Compliance
According to section 1.1310 of FCC 47 CFR Part 1, limits for maximum permissible
exposure (MPE) are as following:


       TABLE 1 – LIMITS FOR MAXIMUN PERMISSIBLE EXPOSURE (MPE)
   Frequency Range            Electric Field      Magnetic Field      Power Density      Averaging Time
          (MHz)                 Strength             Strength
                                  (V/m)                (A/m)            (mW/cm2)             (minutes)
                           (A) Limits for Occupational/Controlled Exposures
  0.3-3.0 ………………                           614                 1.63             *(100)                     6
  3-30 …………………                         1842/f               4.89/f           *(900/f2)                     6
  30-300 ………………                           61.4               0.163                 1.0                     6
  300-1500 …………... …………………. ………………….                                             f/300                     6
  1500-100,000 ……… …………………. ………………….                                                 5                     6
                       (B) Limits for General Population/Uncontrolled Exposure
  0.3-1.34 ……………                           614                 1.63             *(100)                   30
  1.34-30 ……………                           824/f             2.19/f           *(180/f2)                   30
  30-300 ………………                           27.5               0.073                 0.2                   30
  300-1500 …………... …………………. ………………….                                           f/1500                    30
  1500-100,000 ……… …………………. ………………….                                               1.0                   30
      f = frequency in MHz
      * = Plane-wave equivalent power density
      NOTE 1 TO TABLE 1: Occupational/controlled limits apply in situations in which persons are exposed as a
 consequence of their employment provided those persons are fully aware of the potential for exposure and can
 exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when
 an individual is transient through a location where occupational / controlled limits apply provided he or she is
 made aware of the potential for exposure.
      NOTE 2 TO TABLE 1: General population/uncontrolled exposures apply in situations in which the general
 public may be exposed, or in which persons that are exposed as a consequence of their employment may not
 be fully aware of the potential for exposure or can not exercise control over their exposure.


                                                                 FCC ID: VYTLP-9186-001




RF Exposure Calculations:
The following information provides the minimum separation distance for the highest
gain antenna provided. This calculation is based on the highest EIRP possible from
the system, considering maximum power and antenna gain, and considering a 1.0
mW/cm2 uncontrolled exposure limit. The formula shown in OET Bulletin 65 is used in
the calculation.
Equation from page 19 of OET Bulletin 65, Edition 97-01 is:


                                 S= PG / 4πR2
         where: S = power density (in appropriate units, e.g. mW/cm2)
                P = power input to the antenna (in appropriate units, e.g., mW)
                G = power gain of the antenna in the direction of interest relative to
                     an isotropic radiator
                R = distance to the center of radiation of the antenna (appropriate
                     units, e.g., cm)


For our device
P = 632.411 mW
G = 3.32
R = 20 cm

S = (632.411 * 3.32) / (4*π*202) = 0.4177 mW/cm2 < 1.0 mW/cm2


For complying the FCC limits for general population/uncontrolled exposure, the
power density limit is 1.0 mW/cm2. The calculation result of the power density at a
distance of 20 cm of our device is less than the limit.
This means that according to OET Bulletin 65 (Edition 97-01), Supplement C (Edition
01-01), the equipment fulfills the requirements on power density for general
population/uncontrolled exposure and therefore fulfills the requirements of 47 CFR
Part 15.247 (b)(5).



Document Created: 2008-02-14 17:31:16
Document Modified: 2008-02-14 17:31:16

© 2025 FCC.report