Test report

FCC ID: VX5-348RX

Test Report

Download: PDF
FCCID_1717526

                                Global United Technology Services Co., Ltd.

                                                                                Report No: GTSE12050055301
 1 Cover Page

                                 TEST REPORT
 Applicant:                           Thermor Ltd.

 Address of Applicant:                16975 Leslie St., Newmarket, ON, L3Y 9A1, Canada

 Equipment Under Test (EUT)

   Product Name:                      HOME WEATHER STATION WITH WIND SPEED

   Model No.:                         348NC, 348BC, 348BU, 348NU

 FCC ID:                              VX5-348RX

 Applicable standards:                FCC CFR Title 47 Part 15 Subpart B:2010

 Date of sample receipt:              May 29, 2012

 Date of Test:                        May 30-31, 2012

 Date of report issued:               June 01, 2012

 Test Result :                        PASS *
* In the configuration tested, the EUT complied with the standards specified above.




  Authorized Signature:




            Robinson Lo
            Laboratory Manager
 This report details the results of the testing carried out on one sample. The results contained in this test report do not
 relate to other samples of the same product and does not permit the use of the GTS product certification mark. The
 manufacturer should ensure that all products in series production are in conformity with the product sample detailed in
 this report.
 This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other
 than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards. Any
 mention of GTS International Electrical Approvals or testing done by GTS International Electrical Approvals in connection
 with, distribution or use of the product described in this report must be approved by GTS International Electrical
 Approvals in writing.
 This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
 alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be
 prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the
 sample(s) tested and such sample(s) are retained for 90 days only.”


                                                                               Report No: GTSE12050055301

2 Version

   Version No.                        Date                                       Description
         00                     June 01, 2012                                      Original




Prepared by:                                                       Date:                 June 01, 2012

                                   Project Engineer


Reviewed by:                                                       Date:                 June 01, 2012

                                         Reviewer




Global United Technology Services Co., Ltd.                                         Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 2 of 21


                                                                                                                Report No: GTSE12050055301


3 Contents
                                                                                                                                                                      Page
1     COVER PAGE ......................................................................................................................................................... 1

2     VERSION .................................................................................................................................................................. 2

3     CONTENTS .............................................................................................................................................................. 3

4     TEST SUMMARY .................................................................................................................................................... 4

5     GENERAL INFORMATION ................................................................................................................................... 5
    5.1       CLIENT INFORMATION ....................................................................................................................................... 5
    5.2       GENERAL DESCRIPTION OF E.U.T. .................................................................................................................. 5
    5.3       TEST MODE AND VOLTAGE ............................................................................................................................... 5
    5.4       TEST FACILITY................................................................................................................................................... 5
    5.5       TEST LOCATION ................................................................................................................................................ 6
    5.6       DESCRIPTION OF SUPPORT UNITS ................................................................................................................... 6
    5.7       DEVIATION FROM STANDARDS .......................................................................................................................... 6
    5.8       ABNORMALITIES FROM STANDARD CONDITIONS .............................................................................................. 6
    5.9       OTHER INFORMATION REQUESTED BY THE CUSTOMER .................................................................................. 6
6     TEST INSTRUMENTS LIST .................................................................................................................................. 7

7     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    7.1       RADIATED EMISSION ......................................................................................................................................... 8
8     TEST SETUP PHOTO .......................................................................................................................................... 14

9     EUT CONSTRUCTIONAL DETAILS ................................................................................................................. 15




Global United Technology Services Co., Ltd.                                                                                  Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                                Page 3 of 21


                                                                               Report No: GTSE12050040202

4 Test Summary
                  Test Item                               Section in CFR 47                      Result
Conducted Emission                                             Part15.107                          N/A
Radiated Emissions                                             Part15.109                         PASS
PASS: The EUT complies with the essential requirements in the standard.
N/A: not applicable




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 4 of 21


                                                                                 Report No: GTSE12050040202

5 General Information
5.1 Client Information
      Applicant:                         Thermor Ltd.
      Address of Applicant:              16975 Leslie St., Newmarket, ON, L3Y 9A1, Canada


5.2 General Description of E.U.T.
      Product Name:                      HOME WEATHER STATION WITH WIND SPEED
      Model No.:                         348NC, 348BC, 348BU, 348NU
      Power supply:                      DC 4.5V(3*1.5V(”AA” Size battery))
      Remark:                            Only the model 348NC was tested. 348BC, 348BU, 348NU and 348NC are
                                         identical in the same PCB layout, interior structure and electrical circuits. The
                                         only differences are the model name and appearance color for commercial
                                         purpose.


5.3 Test mode and voltage
      Test mode:
      Receive mode                       Keep the EUT in receive the weather data.

5.4 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● FCC —Registration No.: 600491
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and
      fuly described in a report filed with the (FCC) Federal Communications Commission. The
      acceptance letter from the FCC is maintained in files. Registration 600491, July 20, 2010.
      ● Industry Canada (IC)
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been
      Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
      with Registration No.: 9079A-1.




Global United Technology Services Co., Ltd.                                              Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 5 of 21


                                                                               Report No: GTSE12050040202


5.5 Test Location
      All tests were performed at:
      Global United Technology Services Co., Ltd.
      Address: 2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District, Shenzhen,
      China
      Tel: 0755-27798480
      Fax: 0755-27798960

5.6 Description of Support Units
      None.

5.7 Deviation from Standards
      Biconical, log.per. antenna and horn antenna were used instead of dipole antenna.
      Semi-anechoic Chamber was used as alternation of open air test sites, and all test suites were
      performed with radiated method in it.

5.8 Abnormalities from Standard Conditions
      None.

5.9 Other Information Requested by the Customer
      None.




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 6 of 21


                                                                               Report No: GTSE12050040202


6      Test Instruments list
Radiated Emission:

                                                                                Inventory     Cal.Date      Cal.Due date
Item       Test Equipment          Manufacturer             Model No.
                                                                                   No.       (mm-dd-yy)     (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron     9.2(L)*6.2(W)* 6.4(H)     GTS250      Mar. 30 2011    Mar. 29 2013
             Chamber

 2          Control Room         ZhongYu Electron     6.2(L)*2.5(W)* 2.4(H)     GTS251          N/A             N/A

 3        EMI Test Receiver      Rohde & Schwarz             ESU26              GTS203      Jul. 04 2011    Jul. 03 2012
                                SCHWARZBECK
 4       BiConiLog Antenna                                 VULB9163             GTS214      Feb. 26 2012    Feb. 25 2013
                               MESS-ELEKTRONIK
       Double -ridged waveguide SCHWARZBECK
 5                                                         9120D-829            GTS208      Mar. 10 2012    Mar. 09 2013
                  horn         MESS-ELEKTRONIK

 6     Amplifier(100kHz-3GHz)           HP                    8347A             GTS204      Jul. 04 2011    Jul. 03 2012

 7     Amplifier(2GHz-20GHz)            HP                    8349B             GTS206      Jul. 04 2011    Jul. 03 2012

 8        EMI Test Software           AUDIX                    E3                 N/A           N/A             N/A

 9          Coaxial cable              GTS                     N/A              GTS210      Jul. 04 2011    Jul. 03 2012

10          Coaxial Cable              GTS                     N/A              GTS211      Jul. 04 2011    Jul. 03 2012




Global United Technology Services Co., Ltd.                                         Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 7 of 21


                                                                               Report No: GTSE12050040202


7 Test results and Measurement Data
7.1 Radiated Emission
      Test Requirement:                FCC Part15 B Section 15.109
      Test Method:                     ANSI C63.4:2003
      Test Frequency Range:            30MHz to 3000MHz
      Test site:                       Measurement Distance: 3m (Semi-Anechoic Chamber)
      Receiver setup:
                                         Frequency          Detector         RBW          VBW           Remark
                                        30MHz-1GHz         Quasi-peak       120kHz       300kHz     Quasi-peak Value
                                                             Peak            1MHz         3MHz        Peak Value
                                         Above 1GHz
                                                             Peak            1MHz         10Hz
                                                                                          3MHz       Average Value
      Limit:
                                                 Frequency               Limit (dBuV/m @3m)              Remark
                                               30MHz-88MHz                       40.00              Quasi-peak Value
                                              88MHz-216MHz                       43.50              Quasi-peak Value
                                             216MHz-960MHz                       46.00              Quasi-peak Value
                                               960MHz-1GHz                       54.00              Quasi-peak Value
                                                                                 54.00                Average Value
                                                Above 1GHz
                                                                                 74.00                  Peak Value
      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8 meters above the ground
                                          at a 3 meter camber. The table was rotated 360 degrees to determine the
                                          position of the highest radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving antenna, which
                                          was mounted on the top of a variable-height antenna tower.
                                       3. The antenna height is varied from one meter to four meters above the ground to
                                          determine the maximum value of the field strength. Both horizontal and vertical
                                          polarizations of the antenna are set to make the measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case and then
                                          the antenna was tuned to heights from 1 meter to 4 meters and the rota table
                                          was turned from 0 degrees to 360 degrees to find the maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and Specified
                                          Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the limit
                                          specified, then testing could be stopped and the peak values of the EUT would
                                          be reported. Otherwise the emissions that did not have 10dB margin would be
                                          re-tested one by one using peak, quasi-peak or average method as specified
                                          and then reported in a data sheet.
      Test setup:                      Below 1GHz



Global United Technology Services Co., Ltd.                                          Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 8 of 21


                                                                               Report No: GTSE12050040202




                                       Above 1GHz




      Test environment:                Temp.:       25 °C         Humid.:        52%      Press.:    1 012mbar
       Measurement Record:                                                                 Uncertainty: ± 4.5dB
      Test Instruments:                Refer to section 6 for details
      Test mode:                       Refer to section 5.3 for details.
      Test results:                    Pass


Note:
The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
equation with a sample calculation is as follows:

Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 9 of 21


                                                                               Report No: GTSE12050040202


Measurement Data


Below 1GHz
Horizontal:




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 10 of 21


                                                                               Report No: GTSE12050040202


Vertical:




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 11 of 21


                                                                               Report No: GTSE12050040202


Above 1GHz
Horizontal:




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 12 of 21


                                                                               Report No: GTSE12050040202


Vertical:




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 13 of 21


                                                                               Report No: GTSE12050040202


8 Test Setup Photo
       Radiated Emission




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 14 of 21


                                                                               Report No: GTSE12050040202


9 EUT Constructional Details




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 15 of 21


                                                                               Report No: GTSE12050040202




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 16 of 21


                                                                               Report No: GTSE12050040202




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 17 of 21


                                                                               Report No: GTSE12050040202




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 18 of 21


                                                                               Report No: GTSE12050040202




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 19 of 21


                                                                               Report No: GTSE12050040202




Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 20 of 21


                                                                               Report No: GTSE12050040202




                                                  ------ End------


Global United Technology Services Co., Ltd.                                        Project No.: GTSE120500553RF
2nd Floor, Block No.2, Laodong Industrial Zone, Xixiang Road Baoan District,
Shenzhen, China 518102

Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 21 of 21



Document Created: 2012-06-07 16:51:03
Document Modified: 2012-06-07 16:51:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC