test report

FCC ID: VUOTMS6016

Test Report

Download: PDF
FCCID_885714

SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007




         ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT
            INTENTIONAL RADIATOR CERTIFICATION TO
                   FCC PART 95H REQUIREMENTS
                                     OF

                    TELEMETRY MONITORING SYSTEM

                            MODEL No.: TMS-6016

                          BRAND NAME: MINDRAY

                             FCC ID: VUOTMS6016

                          REPORT NO: WE07110002

                          ISSUE DATE: Dec 04, 2007

                                    Prepared for
        SHENZHEN HYT SCIENCE & TECHNOLOGY CO., LTD.
     HYT TOWER, SHENZHEN HI-TECH INDUSTRIAL PARK NORTH,
               BEIHUAN RD., NANSHAN DISTRICT,
                      SHENZHEN, P.R.C.
                                    Prepared by
                SHENZHEN HUATONGWEI INTERNATIONAL
                       INSPECTION CO., LTD
                                       d.b.a.
    SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
      HUATONGWEI BUILDING, KEJI RD. 12 S., HIGH-TECH PARK,
                NANSHAN DISTRICT, SHENZHEN,
                   GUANGDONG, P.R.CHINA

                           TEL: 86-755-26748099
                           FAX: 86-755-26748005




                                                             Pag1
                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                DATE: 12/04/2007

 VERIFICATION OF COMPLIANCE

                         SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD.
        Applicant:       Mindray Building, Keji 12th Road South, High-tech Industrial Park,
                         Nanshan, Shenzhen 518057, P.R. China

  Product Description: Telemetry Monitoring System
      Brand Name:         MINDRAY

     Model Number:        TMS-6016

     Serial Number:       N/A

      File Number:        WE07110002

      Date of Test:       Nov 22, 2006 ~ Dec 02, 2006


We hereby certify that:
The above equipment was tested by SHENZHEN HUATONGWEI INTERNATIONAL
INSPECTION CO., LTD. The test data, data evaluation, test procedures, and equipment
configurations shown in this report were made in accordance with the procedures given in
ANSI C63.4 (2003), TIA/EIA 603 and the energy emitted by the sample EUT tested as
described in this report is in compliance with radiated emission limits of FCC Rules Part 95 H.


 The test results of this report relate only to the tested sample identified in this report.




            Approved By                                          Reviewed By




     Jimmy Li /Executive Manager                          Tracy Qi / RF Engineer
     SHENZHEN HUA TONG WEI                               SHENZHEN HUA TONG WEI
 INTERNATIONAL INSPECTION CO., LTD                  INTERNATIONAL INSPECTION CO., LTD




                                     Table of Contents
                                                                                       Pag2
                                                                                       Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                                                                       DATE: 12/04/2007



1. GENERAL INFORMATION .................................................................................................................... 4
    1.1 PROCUCT DESCRIPTION ...........................................................................................................................4
    1.2 RELATED SUBMITTSL(S) / GRANT(S) .....................................................................................................4
    1.3 TEST METHODOLOGY ...............................................................................................................................4
    1.4 TEST FACILITY ............................................................................................................................................4
    1.5 SPECIAL ACCESSORIES .............................................................................................................................4
    1.6 EQUIPMENT MODIFICATIONS .................................................................................................................4
    1.7 EQUIPENT .....................................................................................................................................................5
    1.8 LABORATORY ACCREDITATIONS AND LISTINGS..............................................................................5
2. SYSTEM TEST CONFIGURATION........................................................................................................ 7
    2.1 EUT CONFIGURATION ...............................................................................................................................7
    2.2 EUT EXERCISE .............................................................................................................................................7
    2.3 SUMMARY OF TEST RESULTS .................................................................................................................7
    2.4 CONFIGUARATION OF TESTED SYSTEM...............................................................................................7
3 DESCRIPTION OF TEST MODES .......................................................................................................... 8
4. CONDUCTED EMISSION TEST ............................................................................................................ 9
    4.1 MEASUREMENT PROCEDURE..................................................................................................................9
    4.2 TEST SETUP BLOCK DIAGRAM................................................................................................................9
    4.3 TEST EQUIPENT USED: ............................................................................................................................10
    4.4 CONDUCTED POWER LINE EMISSION LIMITS ...................................................................................10
    4.5 TEST RESULTS ...........................................................................................................................................10
5. OUTPUT POWER MEASUREMENT (ERP)......................................................................................... 11
    5.1 MEASUREMENT EQUIPMENT USED .....................................................................................................11
    5.2 MEASUREMENT METHOD ......................................................................................................................11
    5.3 TEST RESULTS:..........................................................................................................................................15
6. OCCUPIED BANDWIDTH.................................................................................................................... 16
    6.1 MEASUREMENT PROCEDURE................................................................................................................16
    6.2 TEST SETUP BLOCK DIAGRAM..............................................................................................................16
    6.3 MEASUREMENT EQUIPMENT USED: ....................................................................................................17
    6.4 TEST RESULTS:..........................................................................................................................................17
7. RADIATED EMISSION TEST ............................................................................................................ 19
    7.1 MEASUREMENT PROCEDURE................................................................................................................19
    7.2 TEST SETUP BLOCK DIAGRAM..............................................................................................................20
    7.3 MEASUREMENT EQUIPMENT USED: ....................................................................................................21
    7.4 FIELD STRENGTH CALCULATION ........................................................................................................22
    7.5 TEST RESULTS:..........................................................................................................................................22
8. FREQUENCY STABILITY MEASUREMENT....................................................................................... 25
    8.1 MEASUREMENT PROCEDURE................................................................................................................25
    8.2 TEST SETUP BLOCK DIAGRAM..............................................................................................................25
    8.3 MEASUREMENT EQUIPMENT USED: ....................................................................................................26
    8.4 TEST RESULTS:..........................................................................................................................................26
APPENDIX 1 ............................................................................................................................................ 27
PHOTOGRAPHS OF TEST SETUP......................................................................................................... 27
APPENDIX 2 ............................................................................................................................................ 29
PHOTOGRAPHS OF EUT ....................................................................................................................... 29




                                                                                                                                                 Pag3
                                                                                                                                                 Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                         DATE: 12/04/2007

1. GENERAL INFORMATION

1.1 PROCUCT DESCRIPTION

The SHENZHEN MINDRAY BIO-MEDICAL ELECTRONICS CO., LTD.’s Model: TMS-6016
or the “EUT” as referred to in this report is designed by way of utilizing the FM modulation
achieves the system operating.
* The test data gathered are from typical production samples provided by the manufacturer.
A major technical description of EUT is described as following:
        a). Antenna Designation: Inner
        b). Power Supply: DC 3 V by battery
        c). Operating Frequency Range
             Frequency Range: 608 ~ 614MHz



1.2 RELATED SUBMITTSL(S) / GRANT(S)

This submittal(s) (test report) is intended for FCC ID: VUOTMS6016 filing to comply with the
FCC Part 95H requirements

1.3 TEST METHODOLOGY

The radiated emission testing was performed according to the procedures of ANSI C63.4;
TIA/EIA 603 and FCC CFR 47 2.1046, 2.1047, 2.1049, 2.1051, 2.1053 and 2.1055.

1.4 TEST FACILITY

The fully anechoic chamber test site and conducted measurement facility used to collect the
radiated data is located on the address of SHENZHEN HUATONGWEI INTERNATIONAL
INSPECTION CO., LTD Huatongwei Building, Keji Rd. 12 S., High-tech Park, Nanshan
District, Shenzhen, Guangdong, P.R.China
The fully anechoic chamber Test Sites and the Line Conducted labs are constructed and
calibrated to meet the FCC requirements in documents ANSI C63.4: 2003 and CISPR
22/EN 55022 requirements.

1.5 SPECIAL ACCESSORIES

Not available for this EUT intended for grant.

1.6 EQUIPMENT MODIFICATIONS

Not available for this EUT intended for grant.




                                                                               Pag4
                                                                               Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                              DATE: 12/04/2007

1.7 EQUIPENT

Radiated emissions are measured with one or more of the following types of linearly
polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide,
horn. Spectrum analyzers with preselectors and quasi-peak detectors are used to perform
radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and EMI
Test Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used for
making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference Measuring
Apparatus and Measurement Methods.”

1.8 LABORATORY ACCREDITATIONS AND LISTINGS

The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225
Shenzhen Huatongwei International Inspection Co., Ltd has been assessed and proved to
be in compliance with CNAS-CL01 Accreditation Criteria for Testing and Calibration
Laboratories (identical to ISO/IEC 17025: 2005 General Requirements) for the Competence
of Testing and Calibration Laboratories,Date of Registration: August 02, 2007. Valid time is
until March 04, 2009.

A2LA-Lab Cert. No. 2243.01
Shenzhen Huatongwei International Inspection Co., Ltd, EMC Laboratory has been
accredited by A2LA for technical competence in the field of electrical testing, and proved to
be in compliance with ISO/IEC 17025: 1999 General Requirements for the Competence of
Testing and Calibration Laboratories and any additional program requirements in the
identified field of testing. Valid time is from Aug 24, 2005 to Sept 30, 2009

FCC-Registration No.: 662850
Shenzhen Huatongwei International Inspection Co., Ltd, EMC Laboratory has been
registered and fully described in a report filed with the FCC (Federal Communications
Commission). The acceptance letter from the FCC is maintained in our files. Registration
662850, Renewal date September 12, 2006.

IC-Registration No.: 5377
The 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd has
been registered by Certification and Engineering Bureau of Industry Canada for the
performance of radiated measurements with Registration No. 5377 on November 28th,
2005.

ACA
Shenzhen Huatongwei International Inspection Co., Ltd, EMC Laboratory can also perform
testing for the Australian C-Tick mark as a result of our A2LA accreditation.




                                                                                    Pag5
                                                                                    Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                             DATE: 12/04/2007


NEMKO-Aut. No.: ELA125
Shenzhen Huatongwei International Inspection Co., Ltd has been assessed the quality
assurance system, the testing facilities, qualifications and testing practices of the relevant
parts of the organization. The quality assurance system of the Laboratory has been
validated against ISO/IEC 17025:2005 or equivalent. The laboratory also fulfils the
conditions described in Nemko Document NLA-10.

VCCI
The 3m Semi-anechoic chamber (12.2m×7.95m×6.7m) and Shielded Room (8m×4m×
3m) of Shenzhen Huatongwei International Inspection Co., Ltd has been registered in
accordance with the Regulations for Voluntary Control Measures with Registration No.:
R-2484. Date of Registration: December 20, 2006. Valid time is until December 19, 2009.
Main Ports Conducted Interference Measurement of Shenzhen Huatongwei International
Inspection Co., Ltd has been registered in accordance with the Regulations for Voluntary
Control Measures with Registration No.: C-2726. Date of Registration: December 20, 2006.
Valid time is until December 19, 2009.

IECEE CB
Shenzhen Huatongwei International Inspection Co Ltd has been assessed and determined
to fully comply with the requirements of ISO/IEC 17025: 2005-05, The Basic Rules, IECEE
01: 2006-10 and Rules of Procedure IECEE 02: 2006-10, and the relevant IECEE
CB-Scheme Operational Documents.
It is therefore entitled to operate as a CB Testing Laboratory under the responsibility of
Nemko A/S. This certificate remains valid until May 25th 2009 at which time it will be
reissued by the IECEE Executive Secretary upon successful completion of the normally
scheduled 3-year Reassessment Program administered by the IECEE CB Scheme.

DNV
Shenzhen Huatongwei International Inspection Co Ltd has been found to comply with the
requirements of DNV towards subcontractor of EMC and safety testing services in
conjunction with the EMC and Low voltage Directives and in the voluntary field. The
acceptance is based on a formal quality Audit and follow-ups according to relevant parts of
ISO/IEC Guide 17025(2005), in accordance with the requirements of the DNV Laboratory
Quality Manual towards subcontractors. Valid until 09 Jul, 2010.




                                                                                   Pag6
                                                                                   Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                 DATE: 12/04/2007



2. SYSTEM TEST CONFIGURATION

2.1 EUT CONFIGURATION

The EUT configuration for testing is installed on RF field strength measurement to meet
the Commission’s requirement and operating in a manner which intends to maximize its
emission characteristics in a continuous normal application.

2.2 EUT EXERCISE

The Transmitter was operated in the normal operating mode. The TX frequency was fixed
which was for the purpose of the measurements.

2.3 GENERAL TECHNICAL REQUIREMENTS AND SUMMARY OF TEST RESULTS

                The EUT has been tested according to the following specifications:
                 Standard                            Test Type       Result           Notes


         FCC Part 95 H: 2002             Transmitter Fundamental     PASS           Complies
         Section 95.1115(a)                     Field strength

         FCC Part 95 H: 2002                   Output Power
                                                                     PASS           Complies
         Section 2.1046                      Measurement(ERP)


         FCC Part 95 H: 2002
                                             Occupied Bandwidth      PASS           Complies
      Section 95.1115(d)/2.1049


         FCC Part 95 H: 2002                    Out of Band
                                                                     PASS           Complies
       Section 95.1115(b)/2.1053              Radiated Emission
                                                                              .
                                           Frequency Stability Vs.
                                               Temperature
         FCC Part 95 H: 2002                                                        Complies
                                                Vs. Voltage          PASS
       Section 95.1115(e)/2.1055                                              .


2.4 CONFIGUARATION OF TESTED SYSTEM

            Fig. 2-1 Configuration of Tested System


                                               EUT




                                                                                       Pag7
                                                                                       Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                            DATE:
12/04/2007


3 DESCRIPTION OF TEST MODES

 The EUT has been tested under normal operating condition. Three channels (the top,
 the middle and the bottom) are chosen for testing.




                                                                           Pag8
                                                                           Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                              DATE:
12/04/2007
4. CONDUCTED EMISSION TEST

4.1 MEASUREMENT PROCEDURE

The EUT was tested according to ANSI C63.4 - 2003. The frequency spectrum from
0.15 MHz to 30 MHz was investigated. The LISN used was 50 ohm / 50 u Henry as
specified by section 5.1 of ANSI C63.4 - 2003. Cables and peripherals were moved to
find the maximum emission levels for each frequency.

Note: The EUT will not be operated during charging the battery with the power adapter.

4.2 TEST SETUP BLOCK DIAGRAM

   (Block diagram of configuration)




           Vertical Reference
             Ground Plane



                                                                Test receiver
    40cm
                EUT
                              Periphera
                l




                                            80cm

      LISN
                                             Horizontal Reference
                                              Ground Plane
 For the actual test configuration, Please refer to the related items – Photos of Testing.




                                                                                             Pag9
                                                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                               DATE: 12/04/2007


4.3 TEST EQUIPENT USED:

                                      Conducted Emission Test Site # 3

Name of Equipment          Manufacturer             Model       Serial Number   Calibration Due

  ARTIFICIAL MAINS       ROHDE&SCHWARZ             ESH2-Z5           100028     10/25/2008

EMI TEST RECEIVER ROHDE &SCHWARZ                   ESCS 30           100038     10/25/2008

   PULSE LIMITER         ROHDE&SCHWARZ             ESHSZ2            100044     10/25/2008

EMI TEST SOFTWARE ROHDE&SCHWARZ                  ES-K1 V1.71             N/A    10/25/2008


4.4 CONDUCTED POWER LINE EMISSION LIMITS


     FCC Part 15 Paragraph 15.107 (dBuV)
   Frequency Range Class A       Class B
          (MHz)       QP/AV       QP/AV
      0.15 – 0.5       79/66     66-56/56-46
      0.5 – 5.0        73/60        56/46
       5.0 - 30        73/60        60/50
 NOTE:In the above table, the tighter limit applies at the band edges.

4.5 TEST RESULTS

Owing to the DC operation of EUT, this test item is not performed.




                                                                                      Pag10
                                                                                      Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                              DATE: 12/04/2007

5. OUTPUT POWER MEASUREMENT (ERP)

5.1 MEASUREMENT EQUIPMENT USED


                               Radiated Emission Test Site # 4
Name of Equipment          Manufacturer           Model       Serial Number Calibration Due
  ULTRA-BROADBAND
      ANTENNA            ROHDE & SCHWARZ           HL562           100015       10//2008

    LOOP ANTENNA         ROHDE & SCHWARZ          HFH2-Z2          100020       10//2008

    HORN ANTENNA         ROHDE &SCHWARZ            HF906           100039       10//2008

 EMI TEST RECEIVER       ROHDE & SCHWARZ           ESI 26          100009       10//2008

    RF TEST PANEL        ROHDE & SCHWARZ          TS / RSP      335015/ 0017      N/A

      TURNTABLE                  ETS                2088            2149          N/A

    ANTENNA MAST                 ETS                2075            2346          N/A

 SIGNAL GENERATOR        ROHDE & SCHWARZ           SML02           100507       10/2008

 EMI TEST SOFTWARE ROHDE & SCHWARZ              ES-K1 V1.71         N/A         10//2008
Remark: Each piece of equipment is scheduled for calibration once a year.


5.2 MEASUREMENT METHOD

On a test site, the equipment shall be placed at the specified height on a support, and in the
position closest to normal use as declared by the manufacturer.
The test antenna shall be oriented initially for vertical polarization and shall be chosen to
correspond to the frequency of the transmitter.
The output of the test antenna shall be connected to the measuring receiver.
The transmitter shall be switched on, if possible, without modulation and the measuring
receiver shall be tuned to the frequency of the transmitter under test.
The test antenna shall be raised and lowered through the specified range of height until a
maximum signal level is detected by the measuring receiver.
The transmitter shall then be rotated through 3600 in the horizontal plane, until the
maximum signal level is detected by the measuring receiver. The test antenna shall be
raised and lowered again through the specified range of height until a maximum signal level
is detected by the measuring receiver. The maximum signal level detected by the
measuring receiver shall be noted. The transmitter shall be replaced by a substitution
antenna.
The substitution antenna shall be orientated for vertical polarization and the length of the
substitution antenna shall be adjusted to correspond to the frequency of the transmitter.
The substitution antenna shall be connected to a calibrated signal generator.
If necessary, the input attenuator setting of the measuring receiver shall be adjusted in
order to increase the sensitivity of the measuring receiver.
The test antenna shall be raised and lowered through the specified range of height to
ensure that the maximum signal is received.
The input signal to the substitution antenna shall be adjusted to the level that produces a
                                                                                    Pag11
                                                                                    Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                             DATE: 12/04/2007

level detected by the measuring receiver, that is equal to the level noted while the
transmitter radiated power was measured, corrected for the change of input attenuator
setting of the measuring receiver.
The input level to the substitution antenna shall be recorded as power level, corrected for
any change of input attenuator setting of the measuring receiver.
The measurement shall be repeated with the test antenna and the substitution antenna
orientated for horizontal polarization.
The measure of the effective radiated power is the larger of the two levels recorded at the
input to the substitution antenna, corrected for gain of the substitution antenna if necessary.




                                                                                    Pag12
                                                                                    Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                           DATE: 12/04/2007

TEST CONFIGURATION

Below 1GHz




                                          Biconical or Log antenna



                                             3m

              Turntable
                                                                                           1m to 4m
                              EUT
     Amplifier
       and
     Receiver                                      0.8 m


           Ground Plane                                                  Coaxial Cable




                                                             Antenna mast
                                   d: distance in 3 meters
                                                                            1-4m


                                                                             Amplifier and Receiver
               0.8m
                       Turntable
Signal Generator
                   Substituted Biconical or Log antenna      Biconical or Log antenna




                                                                                                  Pag13
                                                                                                  Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                         DATE: 12/04/2007

Above 1GHz




                                                          Antenna mast




                                d: distance 3 meters                     1-4 meter

                                          d
       0.8m


                   Turntable
                                           Horn antenna
Signal Generator

                      Substituted Horn antenna
                                                                               Receiver




                                                                                               Pag14
                                                                                               Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                     DATE: 12/04/2007

5.3 TEST RESULTS:


    Frequency   S.G level Antenna   Ant Gain Cable Loss    ERP     Limit   Margin
      (MHz)      (dBm) Polarization   dBi       dB        (dBm)   (dBm)     (dB)
      608.3       -8.30       H         3.0      0.6      -5.90   10.8     -16.70


      608.3       -8.40       V         3.0      0.6      -6.00   10.8     -16.80



    Frequency   S.G level Antenna   Ant Gain Cable Loss    ERP     Limit   Margin
      (MHz)      (dBm) Polarization   dBi       (dB)      (dBm)   (dBm)     (dB)
      611.0       -7.60       H         3.0      0.6      -5.20   10.8     -16.00


      611.0      -12.00       V         3.0      0.6      -9.60   10.8     -20.40



    Frequency   S.G level Antenna   Ant Gain Cable Loss    ERP     Limit   Margin
      (MHz)      (dBm) Polarization   dBi       (dB)      (dBm)   (dBm)     (dB)
      613.7       -9.10       H         3.0      0.6      -6.70   10.8     -17.50


      613.7      -10.90       V         3.0      0.6      -8.50   10.8     -19.30

  Remark: ERP=S.G level+Ant Gain-Cable Loss




                                                                           Pag15
                                                                           Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                         DATE: 12/04/2007



6. OCCUPIED BANDWIDTH

6.1 MEASUREMENT PROCEDURE

    1. The EUT was placed on a turn table which is 0.8m above ground plane.
    2. Set EUT as normal operation
    3. Based on FCC Part15 C Section 15.239(a): RBW= 10KHz. VBW= 30 KHz,
       Span=500 KHz.
    4. The useful radiated emission from the EUT was detected by the spectrum analyzer
       with peak detector.

6.2 TEST SETUP BLOCK DIAGRAM




                                   3m

           Turntable
                                                                         1m to 4m
                         EUT
       Spectrum
       Analyzer                         0.8
                                        m


          Ground Plane                                   Coaxial Cable




                                                                               Pag16
                                                                               Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                                        DATE: 12/04/2007


6.3 MEASUREMENT EQUIPMENT USED:


                               3/5 Anechoic Chamber Radiation Test Site # 4
       EQUIPMENT              MFR        MODEL                                    SERIAL           LAST CAL. CAL DUE.
          TYPE                          NUMBER                                    NUMBER
ULTRA-BROADBAND ANTENNA ROHDE & SCHWARZ  HL562                                     100015           2007/10       2008/10
    EMI TEST RECEIVER              ROHDE & SCHWARZ                    ESI 26       100009           2007/10       2008/10
     RF TEST PANEL                 ROHDE & SCHWARZ                  TS / RSP    335015/ 0017             N/A        N/A

       TURNTABLE                             ETS                      2088           2149                N/A        N/A
     ANTENNA MAST                            ETS                      2075           2346                N/A        N/A
   EMI TEST SOFTWARE               ROHDE & SCHWARZ ES-K1 V1.71                       N/A            2007/10       2008/10




6.4 TEST RESULTS:
                                                             * RBW 300 Hz   Delta 3 [T1 ]
                                                             * VBW 1 kHz              -21.29 dB
              Ref   102 dBµV         * Att   10 dB            SWT 2.25 s         5.200000000 kHz
              100                                                           Marker 1 [T1 ]
                                                                                      76.50 dBµV
                                                                               608.300000000 MHz    A
              90
                                                                            Delta 2 [T1 ]
       1 PK
                                                                                      -21.87 dB
       VIEW
              80                                                                -5.600000000 kHz
                                                         1


              70

                                                                                                   PS

              60
                                                     2       3


              50
                                                                                                   3DB
                                                                                                   AC
              40



              30



              20



              10



              Center 608.3 MHz                       20 kHz/                        Span 200 kHz




       Date: 25.DEC.2007         13:47:25




                                                                                                               Pag17
                                                                                                               Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                                           DATE: 12/04/2007
                                                                * RBW 300 Hz   Delta 3 [T1 ]
                                                                * VBW 1 kHz              -21.57 dB
                 Ref   102 dBµV         * Att   10 dB            SWT 2.25 s         5.600000000 kHz
                 100                                                           Marker 1 [T1 ]
                                                                                         73.78 dBµV
                                                                                  610.999600000 MHz   A
                 90
                                                                               Delta 2 [T1 ]
          1 PK
                                                                                         -20.40 dB
          VIEW
                 80                                                                -5.200000000 kHz
                                                            1

                 70

                                                                                                      PS

                 60
                                                        2       3

                 50
                                                                                                      3DB
                                                                                                      AC
                 40



                 30



                 20



                 10



                 Center 611 MHz                         20 kHz/                        Span 200 kHz




          Date: 25.DEC.2007         13:52:46




                                                                * RBW 300 Hz   Delta 3 [T1 ]
                                                                * VBW 1 kHz              -22.19 dB
                 Ref   102 dBµV         * Att   10 dB            SWT 2.25 s         5.600000000 kHz
                 100                                                           Marker 1 [T1 ]
                                                                                         76.30 dBµV
                                                                                  613.699600000 MHz   A
                 90
                                                                               Delta 2 [T1 ]
          1 PK
                                                                                         -21.39 dB
          VIEW
                 80                                                                -5.600000000 kHz
                                                            1


                 70

                                                                                                      PS

                 60
                                                        2       3

                 50
                                                                                                      3DB
                                                                                                      AC
                 40



                 30



                 20



                 10



                 Center 613.7 MHz                       20 kHz/                        Span 200 kHz




          Date: 25.DEC.2007         13:51:07



    TEST RESULTS: THE UNIT DOES MEET THE FCC REQUIREMENTS.


                                                                                                                 Pag18
                                                                                                                 Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                               DATE: 12/04/2007

7.   RADIATED EMISSION TEST

7.1 MEASUREMENT PROCEDURE


1. The EUT was placed on a turn table which is 0.8m above ground plane.
2. Maximum procedure was performed on at least ten highest emissions to ensure EUT
   compliance.
3. And also, each emission was to be maximized by changing the polarization of receiving
    antenna both horizontal and vertical.
4. Repeat above procedures until all frequency measurements have been completed.

Note:
        Three axes are chosen for pretest, the Z axis is the worst mode for final test.




                                                                                     Pag19
                                                                                     Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                           DATE: 12/04/2007


7.2 TEST SETUP BLOCK DIAGRAM

 (Block diagram of configuration)




                                              3m


                  Turntable                                                                 1m to 4m
                                    EUT

           Spectrum                                   0.8
           Analyzer                                   m
                                                                            Coaxial Cable
                Ground Plane

Radiation below 1GHz

                               Ground plane

                                     d: distance in              Antenna
                                     meters                      mast


                                                                                1-4m


                   0.8
                   m
    Signal
    Generator            Turntable
                      Substituted Bilog antenna
                                                            Bilog antenna

                                                              Spectrum analyzer / pre-amp.




                                                                                                 Pag20
                                                                                                 Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                          DATE: 12/04/2007

Radiation above 1GHz

                                                            Antenna mast


                                 Ground plane




                                  d: distance 3 or 1                     1-4 meter
                                  meters

                                            d
            0.8m


                    Turntable
                                            Horn antenna
      Signal
      Generator

                       Substituted Horn antenna




7.3 MEASUREMENT EQUIPMENT USED:

                        3/5 Anechoic Chamber Radiation Test Site # 4
    EQUIPMENT               MFR           MODEL         SERIAL                   LAST            CAL DUE.
      TYPE                               NUMBER         NUMBER                   CAL.
  ULTRA-BROADBAND
      ANTENNA       ROHDE & SCHWARZ               HL562         100015          2007/10           2008/10

 EMI TEST RECEIVER ROHDE & SCHWARZ                ESI 26        100009          2007/10           2008/10
Double-Ridged-Wavegui
                      ROHDE & SCHWARZ             HF906         100039          2007/10           2008/10
   de Horn Antenna
   RF TEST PANEL    ROHDE & SCHWARZ              TS / RSP     335015/ 0017           N/A            N/A

    TURNTABLE                   ETS                2088           2149               N/A            N/A

  ANTENNA MAST                  ETS                2075           2346               N/A            N/A

EMI TEST SOFTWARE ROHDE & SCHWARZ               ES-K1 V1.71       N/A           2007/10           2008/10




                                                                                                Pag21
                                                                                                Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                          DATE: 12/04/2007

7.4 FIELD STRENGTH CALCULATION


     The field strength is calculated by adding the Antenna Factor and Cable Factor and subtracting the
     Amplifier Gain and Duty Cycle Correction Factor (if any) from the measured reading. The basic equation with a
     sample calculation is as follows:

                FS = RA + AF + CL - AG


     Where     FS = Field Strength                           CL = Cable Attenuation Factor (Cable Loss)
              RA = Reading Amplitude                         AG = Amplifier Gain
              AF = Antenna Factor




7.5 TEST RESULTS:

TEST DATA
                                               Ant./CL
           Frequency Read             Ant                      Result FS    Limit      Margin
                     dBuV       Polar Height Amp.CF(dB)        dBuV/m       dBuV/m     dBuV/m
            (MHz)                            dB
                     PK               m                        PK                      PK
             608.3      66.5    H        1.2    22.8           89.3        106        -16.7
             608.3      66.4    V        1.1    22.8           89.2         106       -16.8


                     Read             Ant      Ant./CL         Result FS    Limit      Margin
           Frequency            Polar Height Amp.CF(dB)
                     dBuV                                      dBuV/m       dBuV/m     dBuV/m
            (MHz)                            dB
                     PK               m                        PK                      PK
             611.0      67.1    H        1.2    22.9           90.0          106       -16.0
             611.0      62.7    V        1.1    22.9           85.6          106       -20.4

                                               Ant./CL
           Frequency Read             Ant                      Result FS    Limit      Margin
                     dBuV       Polar Height Amp.CF(dB)        dBuV/m       dBuV/m     dBuV/m
            (MHz)                            dB
                     PK               m                        PK                      PK
             613.7      65.5    H        1.2    23.0           88.5          106       -17.5
             613.7      63.7    V        1.1    23.0           86.7          106       -19.3




  Remark:
  (1)     Measuring frequencies from 25 MHz to the 1GHz。
  (2)     The IF bandwidth of EMI Test Receiver between 25MHz to 1GHz was 120KHz.




                                                                                                 Pag22
                                                                                                 Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                    DATE: 12/04/2007

Operation Mode: Transmitting Mode
Test Date: Nov 22, 2007
Fundamental Frequency: 608.3 MHz / 611 MHz / 613.7 MHz
Test By: Tracy Qi
Rules Part No.: FCC Part 95H
Temperature: 23℃
Humidity: 53 %
Requirements: OUT-OF-BAND EMISSIONS SHALL NOT EXCEED:
               30 -88 MHz       40.0 dBuV/m MEASURED AT 3 METERS
               88 - 216 MHz     43.5 dBuV/m
               216 - 960 MHz    46.0 dBuV/m
               ABOVE 960 MHz 54.0 dBuV/m

608.3 MHz

   Frequency Read      Ant./CL    Result     Polar   Ant         Limit        Margin
   (MHz)     (dBuV)    Amp.CF(dB) (dBuV/m)   H/V     Height(m)   (dBuV/m)     (dB)
     397.40    10.1        20.1      30.2      H        2.0         46.0         -15.8
     1216.6    41.5       -10.4      31.1      H        2.0         54.0         -22.9
      Other     --                    --

   Frequency Read      Ant./CL    Result     Polar   Ant         Limit        Margin
   (MHz)     (dBuV)    Amp.CF(dB) (dBuV/m)   H/V     Height(m)   (dBuV/m)     (dB)
     922.20     5.5        25.5      31.0      V        2.1         46.0         -15.0
     1216.6    41.0       -10.4      30.6      V        2.3         54.0         -23.4
      Other     --                   --

611.0 MHz

   Frequency Read      Ant./CL    Result     Polar   Ant         Limit        Margin
   (MHz)     (dBuV)    Amp.CF(dB) (dBuV/m)   H/V     Height(m)   (dBuV/m)     (dB)
     935.90     6.3        25.5      31.8      H        2.0         46.0         -14.2
    1222.00    41.1       -10.1      31.0      H        2.1         54.0         -23.0
     Other      --                    --

   Frequency Read      Ant./CL    Result     Polar   Ant         Limit        Margin
   (MHz)     (dBuV)    Amp.CF(dB) (dBuV/m)   H/V     Height(m)   (dBuV/m)     (dB)
     955.30     6.0       25.6       31.6      V        2.0         46.0         -14.4
    1222.00    40.9.      -10.1      30.8      V        2.3         54.0         -23.2
     Other      --                    --

613.7 MHz

   Frequency Read      Ant./CL    Result     Polar   Ant         Limit        Margin
   (MHz)     (dBuV)    Amp.CF(dB) (dBuV/m)   H/V     Height(m)   (dBuV/m)     (dB)
     372.10    10.9       18.6       29.5      H        2.0         46.0         -16.5
    1227.40    41.5.      -9.8       31.7      H        2.2         54.0         -22.3
     Other      --                    --



                                                                            Pag23
                                                                            Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                                        DATE: 12/04/2007


   Frequency Read              Ant./CL    Result             Polar   Ant            Limit         Margin
   (MHz)     (dBuV)            Amp.CF(dB) (dBuV/m)           H/V     Height(m)      (dBuV/m)      (dB)
      30.00           2.1           21.2           23.3         V          2.0          40.0         -16.7
     1227.40         41.3.          -9.8           31.5         V          2.3          54.0         -22.5
      Other           --                            --


SAMPLE CALCULATION: FSdBuV/m = MR (dBuV) + ACFdB.

Remark:
          (1) Measuring frequencies from 30 MHz to the 6.5 GHz.
          (2) Radiated emissions measured in frequency range from 30 MHz to 1000MHz were
              made with an instrument using Peak detector mode.
          (3) “F” denotes fundamental frequency; “H” denotes spurious frequency. “E” denotes
              Band edge frequency.
          (4) Data of measurement within this frequency range shown “-“ in the table above
              Means the reading of emissions are attenuated more than 20dB below the permissible limits or the
              field strength is too small to be measured.
          (5) The IF bandwidth of SPA 30 MHz to 1GHz was 100KHz,
          (6) Above 1 GHz, the RBW= 1000KHz. VBW= 3000 KHz. Peak detector mode.



TEST RESULTS: THE UNIT DOES MEET THE FCC REQUIREMENTS.




                                                                                               Pag24
                                                                                               Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                        DATE: 12/04/2007

8. FREQUENCY STABILITY MEASUREMENT

8.1 MEASUREMENT PROCEDURE

 Measurements were performed with the EUT operating under extremes of temperature in
 10 degree increments within the range –20 to 60 degrees C.
 Measurements were also performed at voltage extremes between the declared nominal
 supply voltage and at the declared endpoint voltage (for battery operated equipment) or
 by varying the primary supply voltage from 85% to 115% of the nominal value for all other
 equipment types. The requirement was to determine the frequency stability of the device
 under specified environmental operating conditions.
 The EUT was switched off for a minimum of 30 minutes between each stage of testing
 while the environmental chamber stabilized at the next temperature within the stated
 temperature range.
 Once the environmental chamber had reached thermal equilibrium, the nominal
 frequency of the EUT was measured and recorded. The recorded frequency was
 compared to the appropriate operating frequency band edge.
 In order to show compliance, the measured frequency must remain within the declared
 frequency band.

8.2 TEST SETUP BLOCK DIAGRAM

   (Setup block diagram of configuration)
TEST SETUP:




                                   EUT




   DC Power Supply               Chamber                   Spectrum Analyzer




                                                                               Pag25
                                                                               Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016                            DATE: 12/04/2007


8.3 MEASUREMENT EQUIPMENT USED:


Name of Equipment Manufacturer            Model       Serial Number Calibration Due
Communication Test Set      HP           HP8920B       US35010135         10/25/2008

   Climate Chamber         ESPEC          EL-10KA       05107008          10/25/2008


8.4 TEST RESULTS:

Results Top Channel (613.70 MHz)
  Temp          Freq.       Measured       Upper Band      Margin
                                                                      Result
   (℃)        Error (Hz)   Freq. (MHz)   Edge Limit(MHz)   (MHz)
   -30           1310       613.70131         614.0        0.29869    Complied
   -20           1280       613.70128         614.0        0.29872    Complied
   -10           1010       613.70101         614.0        0.29899    Complied
    0            780        613.70078         614.0        0.29922    Complied
   10            280        613.70028         614.0        0.29972    Complied
   20            180        613.70018         614.0        0.29982    Complied
   30            280        613.70028         614.0        0.29972    Complied
   40            280        613.70028         614.0        0.29972    Complied
   50            480        613.70048         614.0        0.29952    Complied
   60            500        613.70050         614.0        0.29950    Complied

  Supply
                Freq.       Measured       Upper Band       Margin
  Voltage                                                               Result
              Error (Hz)   Freq. (MHz)   Edge Limit(Mhz)    (MHz)
    (V)
    3.4           70        613.70007         614.0         0.29993   Complied
    3.0           50        613.70005         614.0         0.29995   Complied
    2.0           80        613.70008         614.0         0.29992   Complied

Results Bottom Channel (608.30 MHz)
  Temp          Freq.       Measured       Low Band        Margin
                                                                      Result
   (℃)        Error (Hz)   Freq. (MHz)   Edge Limit(MHz)   (MHz)
   -30           2180       608.30218         608.0        0.30218    Complied
   -20           2100       608.30210         608.0        0.30210    Complied
   -10           1080       608.30108         608.0        0.30108    Complied
    0            1010       608.30101         608.0        0.30101    Complied
   10             800       608.30080         608.0        0.30080    Complied
   20             800       608.30080         608.0        0.30080    Complied
   30             800       608.30080         608.0        0.30080    Complied
   40            1000       608.30100         608.0        0.30100    Complied
   50            1100       608.30110         608.0        0.30110    Complied
   60            1100       608.30110         608.0        0.30110    Complied

  Supply
                Freq.       Measured        Low Band        Margin
  Voltage                                                               Result
              Error (Hz)   Freq. (MHz)   Edge Limit(Mhz)    (MHz)
    (V)
    3.4           100       608.30010         608.0         0.30010   Complied
    3.0            60       608.30006         608.0         0.30006   Complied
    2.0            90       608.30009         608.0         0.30009   Complied

                                                                                  Pag26
                                                                                  Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007




                                APPENDIX 1


                     PHOTOGRAPHS OF TEST SETUP




                                                             Pag27
                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007


                           Test Setup Photo-1




                             Test Setup Photo-2




                                                             Pag28
                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007




                                APPENDIX 2


                         PHOTOGRAPHS OF EUT




                                                             Pag29
                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007

                              External of EUT




                                                             Pag30
                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007




                                                             Pag31
                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007


                            Internal view of EUT




                                                             Pag32
                                                             Rev. 00


SHENZHEN HUATONGWEI INTERNATIONAL INSPECTION CO., LTD
REPORT NO: WE07110002          FCC ID: VUOTMS6016       DATE: 12/04/2007




                                                             Pag33
                                                             Rev. 00



Document Created: 2008-01-02 22:50:44
Document Modified: 2008-01-02 22:50:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC