After entering PIN code, click Next.           Select SPP-R200 from the list.

*Default PIN code for SPP-R200 printer
 is “0000”.




 Select Serial Port                           Select New Outgoing Port from COM
                                              Ports tab.




 Select SPP-R200.                             Select COM 2 and click Finish.
                                              After the pairing, Data transfer/reception is
                                              possible via COM2




                                         45
     AT870N User Guide


   * If the device information is not displayed correctly, please try Add New Devices again.

   * PIN code used in pairing can be mutually set on devices.

   * After the normal pairing, S/W, SDK etc. provided from Bluetooth manufacturer can be
     used for further Bluetooth services.


3.3 Bixolon SPP-R200 Printer Demo

      SPP-R2000 of Bixolon’s leading mobile printer is used for Bluetooth Print
      demonstration. Application listed on the homepage was used for the test.
      **The SDK and programs from 2011/08/05 was used for the demonstration test and it
      may be different from the ones that are presently listed on Bixolon homage.

   1. Go to Bixolon website (www.bixolon.com) for “SPP-R200 Windows SDK”, and unzip
       the file onto the hard drive.
   2. Turn on Bluetooth Power.
   3. Run “Bluetooth Device Properties” from Control Panel.
   4. Turn on SPP-R200.
   5. Set SPP-R200 printer into Bluetooth mode (Refer to SPP-R200 User Guide for the
       details.)
   6. Click Scan Device to search for the devices nearby that can be paired.
   7. Try pairing with SPP-R200 when searched on the list. PIN code is “0000” if the setting
       is in default.
   8. If the pairing is successful, message that device is connected via COM2 port is
       shown on the screen (If the pairing has been performed previously, the message may
       not be shown.)
   9. In the downloaded SDK from Bixolon website, copy DLL files and execute files from
       bin\wm6\ folder to Flash Disk folder of AT870N.
   10. Run Sample.exe from Flash Disk folder of AT870N.
   11. Since SPR-R200 is allocated in COM2, change COM8 to COM2 and click Open.
   12. Click on the Printing button and Sample Printing to check if the printing is performed.




    COM8 -> COM2                     Select Open and then select      Select Sample Printing
                                     Printing


                                            46

                                                                           AT870N User Guide


4. Phone


4.1 Turn
    T    on the
              e phone

  1. [Home] -> [Phone]
               Phone]
  2. [Start]->[P
  3. Press                  he keypad.
                      from th




4.2M
   Making a ph
             hone call

                                         Icon                              Desc
                                                                              cription

                                                     D
                                                     Delete the numbers.


                                                     Speed dial ca
                                                     S           an be used to
                                                                             o call the pre
                                                                                          e-stored num
                                                                                                     mber
                                                     by pressing on
                                                                  o accordingg number. (S  Speed dial can
                                                                                                      c
                                                      ave up to 98
                                                     sa          8 numbers.)


                                                     C History.
                                                     Call


                                                     Ta enables the
                                                     Talk       t calling.




      The spee
              ed dial number is press
                                    sed for a few
                                                w seconds for the speed dial calls.




                                                47
       AT870N U
              User Guide


4.3 Receiving calls

                          Icon                             Description


                                      Receives the incoming calls.



                                      Rejects the incoming calls.




                          Receiving call messages may be displayed differently.




4.4Hanging up calls

                          Icon                             Description

                                      Use Speaker phone.


                                      Use Mute.


                                      Put the current phone call on hold state.


                                      After putting the call on hold, add another call.

                                      Contact can be used for search/add/delete of
                                      contacts.

                                      End calls.




                                 48

                                                                     AT870N User Guide


4.5Switching calls

                            Icon                            Description

                                        Put the current call on hold and the call that was on
                                        hold back to call state.




5. Contacts

5.1Contacts

  1. [Home] -> [Contacts]
  2. [Start]->[Contacts]




                                   49
      AT870N User Guide


5.2 Search for Contacts




  Enter a name for searching.

5.3 Adding New Contacts




      Click on the button to add             Select a contact type.
        new contacts.




                                   50

                                        AT870N User Guide


6. Text Message

6.4 Replying to the Text Message




     Click on the message from the               Click on the Reply.
     Inbox




      Enter the messages and click on the
      button to send.




                                            51
      AT870N User Guide


7. GPS Module
GPS Module can be selected as an option in AT870N, and GPS Module is built-in at the top of the
handheld.
GPS program port: GPD1
GPS hardware port: COM6, 9600

7.1GPS Demo Program

                               Run application
                               - [Start Button] -> [DEMO_GPS_WM]




                               Main Window
                               - Start: Start receiving GPS Data
                               - Stop: Stop receiving GPS Data




  Checking on GPS Data Reception:
     1. The reception has to be checked in an open area.
     2. The reception time for GPS Data can be different depending on the
         environments. (About 3~10 minutes)
         After the receiving the GPS data at first, it may take less time for
         reconnection/reception of GPS data next time.


8. Camera
The handheld can be equipped with 3.0-megapixel camera with functions of adjusting brightness
and resolution, capture, video etc.


                                              52

                                                                            AT870N User Guide


8.1 Camera




Run application
- [Start Button] -> [Pictures & Videos] -> [Camera]

Main Window
- Thumb…: Close the main window and go to Pictures & Videos screen.
- Menu: Menu popup
- To save screen, press “Enter” from the keypad.


9. HF13.56MHz
The handheld can be equipped with HF13.56Mhz module internally. According to ISO standards, it
can read tags from 3~8.5cm distance (For Mifare, the distance is 1~3.5cm).

9.1RF13.56 Demo Program

Run application
- [Start Button] -> [DEMO_HF]




Mifare Window


                                                  53
        AT870N User Guide


- Open: Open HF device
- Antenna: Stops the antenna signal.
- Perform: Run the selected command from combo box.
- ISO>: Change to ISO-15693 command screen.
- Block: Number of Block be accessed.
- Key Type: Key type of Block to be accessed.
- Key Set: Key set of Block to be accessed.




                              ISO-15693 Window
                              - <MF: Change to Mifare command screen
                              - Block: Start number of Block to be accessed.
                              - Read Count: Number of Block to be accessed




                                            54

                                                                               AT870N User Guide


10. Smart Card Device
The handheld can communicate with IC Card via ISO-7816.


10.1Smartcard Program

                           Run application
                           - [Start Button] -> [DEMO_SAM]




                           Main Window
                           - Slot Status: Check the status of the slot.
                           - PowerOn: Authorize the power of smart card device.
                           - PowerOff:Unauthorize the power of smart card device.
                           - SetParam: Set protocol type, clock rate, bit rate etc. of the card
                                        device.
                           - GetParam: Read protocol type, clock rate, bit rate etc. of the card
                                          device.
                           - Default: Set to default settings.
                           - TxBlock: Transfer APDU Command to the card device.
                           - FwVersion: Read the firmware version of the card device.




                                          55
      AT870N User Guide


11. UHF 900
          0Mhz
The handheld can be equip
                        pped with UHF
                                   U   900Mhz. It can rea
                                                        ad or write E
                                                                    EPC GEN2 2 protocol
RFID
   D tags. The frequency range is 85
                                   50 ~ 960Mh
                                            hz which caan be adjustted according to the
coun
   ntries.




     UHF
    Reader




11.1 UHF 900M
            Mhz Program
                      m

                            Run app  plication
                            - [Start Button]
                                     B       -> [DE
                                                  EMO_UHF]




                            Main Wiindow

                            - Start: Start
                                     S     the Inveentory.
                            - Clear: Clear
                                     C      all the tag informattion shown on the screen
                                                                                       n.
                            - Menu: Main menu




                                           56

                                                                              AT870N User
                                                                                     U    Guide


                                  Application option menu
                                  - Read/Write: Perform Read/Write.
                                  - Lock/Kill: Perform Lock/Kill.
                                  - Option: Application option
                                  - Version: Version information




Read/Write Window
- Mask: Selected value from main window is displayed here. It is
          used as masking pattern when performing Read/Write.
          Even if there are many tags nearby, only tags that are set
          as masking pattern can be read or written.
- Kill Pwd, Access Pwd: Read/Write tag’s Kill password, access
                           password.
- EPC length: Read/Write tag’s EPC length.
                Even if 128 bit sized tags are used, if the EPC
                length is set to 96 bit, then the Inventory is only
                performed on 96 bit.
            Please refer to EPC Class1 Gen2 specification details.
         - Read/Write: Read/Write on selected Memory Bank.
         - MemBank: Target memory bank of Read/Write.
         - Ptr: Start of Memory bank’s offset
- Seconds: Time taken in seconds for Read/Write.
                                    - Format: format the data to be Read/Write.

                                  Lock/Kill Window
                                  - Mask: Selected value from main window is displayed here. It is
                                           used as masking pattern when performing Lock/Kill.
                                           Even if there are many tags nearby, only tags that are set
                                           as masking pattern can be lock/kill.
                                  - Kill Pwd, Access Pwd: Read/Write tag’s Kill password, access
                                  password.
                                  - EPC length: Read/Write tag’s EPC length.
                                  Even if 128 bit sized tags are used, if the EPC length is set to 96 bit,
                                  then the Inventory is only performed on 96 bit.
                                  Please refer to EPC Class1 Gen2 specification details.

                                  - Do Lock: Perform on Lock as it is set in the checkboxes.
                                  - Kill: Kill tags. Once the Kill tag is performed it cannot be restored
                                  to its original state.




                                                  57
        AT870N User Guide


Options Window
       - Session: Change Session that is used in Tag operation
       - Target: Change Target that is used in Tag operation
       - Q: Change Q that is used in Tag operation
       - LBT Ch State/Time: Change LBT option that is used in Europe, Japan frequencies (Not
       available)
       - Power: Change Tx Power level of the reader.



                               Version Window
                               - Demo app Ver: Demo application version
                               - Firmware Ver: UHF module firmware version
                               - Protocol Ver: UHF module library version
                               - Hopping Mode: UHF module’s country version
                               - Max TxPwr: UHF module’s max output




                                             58

                                                                              AT870N User Guide


Chapter 5. Appendix
Product Specifications

Physical Characteristics
Dimension(L*W*H)       76 X 148 X 24.8(30.5) mm
Weight                 320g (PDA only, without Battery)
Operating Temp.        -20℃ ~ 60℃
Storage Temp.          -30℃ ~ 70℃
Humidity               95% Non-condensing
Drop                   1.5m Drop to concrete
Performance Characteristics
Processor              Marvell PXA320 806MHz
Operating System       Windows CE 5.0
Memory                 512MB RAM / 512MB ROM
                       3.5" QVGA with Backlight
Display                TFT LCD, 240*320 Pixel, 262,144color
                       Stylus Touch Screen Interface
Audio                  Phone Receiver, Speaker, Ear Jack, Microphone
Standard I/O Port      USB 1.1 Client / USB Host & Serial (RS-232) via gender cable or cradle
                       1 Micro SD slot (SDHC support)
Expansion Slot
                       1 SIM slot
Keypad                 29 key
Notification           Vibrator and LED, Speaker
Power System
                       Lithium ion 3.7V Above 2,960mAH(Rechargeable)
Battery
                       Up to 4,400mAH(Optional)
Back-up Battery        Lithium Polymer 3.7V, 80mAH(Rechargeable)
Power Adapter          Input AC110~240V / Output DC 5V 3A
Network characteristic
Radio                  MODEM 3G (GSM / GPRS / HSDPA / HSPA+)
WLAN                   IEEE 802.11 b/g/a compliant
Antenna                Internal LAN & WAN
Data Capture Device
Scanner                1D Laser, 2D Imager Barcode Scanner
Camera                 3.0 Megapixel Auto Focus with Flash
UHF 900MHz tag reader
Frequency              860MHz- 960Mhz(Adjustable)
Reading Range          0m ~ 7m (differs from each tag)


                                                59
          AT870N User Guide


Writing Range      0m ~ 3m (According to Tag & Environment)
Antenna Gain       2 dbi (Standard)
Speed              62.5 kbps
RF Output          1W EIRP
                   EPC Gen2 ISO 18000 6C
Protocol
                   ISO 18000 6B(Optional)
Special Function   Anti-collision




                                            60

                                                              AT870N User Guide


                    61
AT870N User Guide



Document Created: 2016-12-20 10:52:44
Document Modified: 2016-12-20 10:52:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC