Test Report

FCC ID: VTO0711RG01-1T

Test Report

Download: PDF
FCCID_873726

FCC ID: VTO0711RG01-1T




                               FCC TEST REPORT

               REPORT NO.: 071114FIA01
                 MODEL NO.: RG01-1T
                   RECEIVED: Nov. 13, 2007
                      TESTED: Nov. 13 ~ Nov. 16, 2007
                          ISSUED: Nov. 20, 2007




                 APPLICANT: ProCom Electric Appliances (Shanghai) Co., Ltd.

                   ADDRESS: #1118 Huicheng Road, Nanhui Industrial Park,
                            Nanhui 201300, Shanghai




                  ISSUED BY: ADT (Shanghai) Corporation
                   ADDRESS: 2F, Building C, No.1618, Yishan rd., 201103,
                            Shanghai, China



  This test report consists of 30 pages in total. It may be duplicated completely for legal use with the
  approval of the applicant. It should not be reproduced except in full, without the written approval of
  our laboratory. The client should not use it to claim product endorsement by A2LA or any
  government agencies. The test results in the report only apply to the tested sample. The test
  results in this report are traceable to the national or international standards. This report contains
  data that were produced under Laboratory ADT (Shanghai) Corporation.

                                                                     ADT (Shanghai) Corporation.




                                                                                                V 2.1.0




Report No.: 071114FIA01                             1


FCC ID: VTO0711RG01-1T



                                          Table of Contents
1        CERTIFICATION......................................................................................................3

2        SUMMARY OF TEST RESULTS .............................................................................4
2.1       MEASUREMENT UNCERTAINTY ..........................................................................4
3        GENERAL INFORMATION ......................................................................................5
3.1       GENERAL DESCRIPTION OF EUT........................................................................5
3.2       DESCRIPTION OF TEST MODES..........................................................................5
3.3       GENERAL DESCRIPTION OF APPLIED STANDARDS .........................................7
3.4       DESCRIPTION OF SUPPORT UNITS....................................................................7
4        EMISSION TEST .....................................................................................................8
4.1       CONDUCTED EMISSION MEASUREMENT ..........................................................8
4.1.1     LIMITS OF CONDUCTED EMISSION MEASUREMENT .......................................8
4.1.2     TEST RESULTS ......................................................................................................8
4.2       DEACTIVATION TIME.............................................................................................9
4.2.1     LIMITS OF DEACTIVATION TIME MEASUREMENT .............................................9
4.2.2     TEST INSTRUMENTS ............................................................................................9
4.2.3     TEST PROCEDURES .............................................................................................9
4.2.4     DEVIATION FROM TEST STANDARD ...................................................................9
4.2.5     TEST SETUP ..........................................................................................................9
4.2.6     TEST RESULTS ....................................................................................................10
4.3       RADIATED EMISSION MEASUREMENT .............................................................12
4.3.1     LIMITS OF RADIATED EMISSION MEASUREMENT ..........................................12
4.3.2     TEST INSTRUMENTS ..........................................................................................14
4.3.3     TEST PROCEDURE .............................................................................................15
4.3.4     DEVIATION FROM TEST STANDARD .................................................................15
4.3.5     TEST SETUP ........................................................................................................16
4.3.6     EUT OPERATING CONDITIONS..........................................................................16
4.3.7     TEST RESULTS ....................................................................................................17
4.4       20DB OCCUPIED BANDWIDTH MEASUREMENT..............................................23
4.4.1     LIMITS OF BAND EDGES MEASUREMENT .......................................................23
4.4.2     TEST INSTRUMENTS ..........................................................................................23
4.4.3     TEST PROCEDURES ...........................................................................................24
4.4.4     DEVIATION FROM TEST STANDARD .................................................................24
4.4.5     TEST SETUP ........................................................................................................24
4.4.6     TEST RESULTS ....................................................................................................25
5        PHOTOGRAPHS OF THE TEST CONFIGURATION ............................................26

6        PHOTOGRAPHS OF THE EUT.............................................................................27

7        APPENDIX A - INFORMATION ON THE TESTING LABORATORY......................30

8        APPENDIX B – UNCERTAINTY IN EMC MEASUREMENT..................................31




Report No.: 071114FIA01                                         2


FCC ID: VTO0711RG01-1T


  1 CERTIFICATION

            PRODUCT:          Fireplace Transmitter
           MODEL NO.:         RG01-1T
           APPLICANT:         ProCom Electric Appliances (Shanghai) Co., Ltd.
              TESTED:         Nov. 13 ~ Nov. 16, 2007
            TEST ITEM:        ENGINEERING SAMPLE
          STANDARDS:          FCC Part 15:2007,
                              Subpart C (Section 15.209 and 15.231),
                              ANSI C63.4-2003



 We, ADT (Shanghai) Corporation, declare that the equipment above has been
 tested in our facility and found compliance with the requirement limits of
 applicable standards. The test record, data evaluation and Equipment Under Test
 (EUT) configurations represented herein are true and accurate under the
 standards herein specified.




   TECHNICAL
   ACCEPTANCE             :                             , DATE:     NOV. 20, 2007
                                      Joy Zhu
                               Engineering Supervisor



   APPROVED BY :                                        , DATE:     NOV. 20, 2007
                                    Wallace Pan
                               Director of Operations




Report No.: 071114FIA01                         3


FCC ID: VTO0711RG01-1T


  2 SUMMARY OF TEST RESULTS

The EUT has been tested according to the following specifications:

                          APPLIED STANDARD: FCC Part 15, Subpart C
    Standard
                              Test Type              Result               Remarks
    Paragraph
   15.207            Conducted Emission Test          N/A     Please refer to 4.1.2.
   15.231(a)         De-activation Time              PASS     Meet the requirement of limit
   15.209                                                     Minimum passing margin is
                     Radiated Emission Test          PASS
   15.231(b)                                                  –18.04 dB at 1301.76 MHz
                     20dB Occupied Bandwidth
   15.231(c)                                         PASS     Meet the requirement of limit
                     Measurement




2.1 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated
for tests performed on the EUT as specified in CISPR 16-4-2:

This uncertainty represents an expanded uncertainty expressed at approximately the
95% confidence level using a coverage factor of k=2.

                 MEASUREMENT                   FREQUENCY                UNCERTAINTY
              Conducted emissions              9kHz ~ 30MHz                 3.04 dB
                                              30MHz ~ 200MHz
                                                                            4.42 dB
                                                (Horizontal)
                                              30MHz ~ 200MHz
                                                                            4.62 dB
                                                 (Vertical)
               Radiated emissions
                                            200MHz ~ 1000MHz
                                                                            4.06 dB
                                               (Horizontal)
                                            200MHz ~ 1000MHz
                                                                            4.16 dB
                                                (Vertical)

Note: The measurement uncertainty is factored into the compliance determination. The additional
      information is listed on APPENDIX B of this report.




Report No.: 071114FIA01                          4


FCC ID: VTO0711RG01-1T


  3 GENERAL INFORMATION

3.1 GENERAL DESCRIPTION OF EUT

    PRODUCT                          Fireplace Transmitter
    MODEL NO.                        RG01-1T

    POWER SUPPLY                     4.5Vdc from batteries

    MODULATION TYPE                  ASK
    CARRIER FREQUENCY
                                     434.032 MHz
    OF EACH CHANNEL
    NUMBER OF CHANNEL                1

    ANTENNA TYPE                     Printed antenna

    DATA CABLE SUPPLIED              N/A

    I/O PORTS                        N/A

 NOTE: The above EUT information was declared by manufacturer and for more detailed
       features description, please refer to the manufacturer's specifications or User's Manual.




3.2 DESCRIPTION OF TEST MODES

One channel is provided to this EUT:

      Channel                 Frequency
           1                 434.032 MHz


Two buttons with remote controller are provided to this EUT:

         No.                         Button
           1                      Switch button
           2              Background light control button




Report No.: 071114FIA01                           5


FCC ID: VTO0711RG01-1T


TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL:


         EUT                              Applicable to
       configure                                                                         Description
         mode             PLC           De-a T       RE          20dB OBM

            A              -              √          √                √         Continuously transmitting
       Where    PLC: Power Line Conducted Emission          De-a T: De-activation Time
                RE: Radiated Emission                      20dB OBM: 20dB Occupied Bandwidth Measurement




Radiated Emission Test:
   Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
    between available modulations, and X.Y.Z. axis.
    Following channel(s) was (were) selected for the final test as listed below.
        Available          Tested       Modulation
                                                          Axis
        Channel           Channel         Type
           1                 1            ASK              X




Report No.: 071114FIA01                               6


FCC ID: VTO0711RG01-1T



3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS

The EUT is a remote controller. According to the specifications of the manufacturer, it
must comply with the requirements of the following standards:

 FCC Part 15, Subpart C. (15.231)
 ANSI C63.4- 2003

All test items have been performed and recorded as per the above standards.




3.4 DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit.




                                            EUT


                                   (Powered by batteries)

             Test table



Note: When doing the test, fresh batteries were used.




Report No.: 071114FIA01                           7


FCC ID: VTO0711RG01-1T


  4 EMISSION TEST

4.1 CONDUCTED EMISSION MEASUREMENT

4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT

                          FREQUENCY (MHz)         Quasi-peak          Average
                              0.15 - 0.5               66 - 56         56 - 46
                              0.50 - 5.0                 56              46
                              5.0 - 30.0                 60              50

  NOTES: 1. The lower limit shall apply at the transition frequencies.
         2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50
            MHz.




4.1.2 TEST RESULTS
Since the EUT does not have AC power port, the test item is not applicable.




Report No.: 071114FIA01                            8


FCC ID: VTO0711RG01-1T


4.2 DEACTIVATION TIME
4.2.1      LIMITS OF DEACTIVATION TIME MEASUREMENT
    TEST STANDARD:
    FCC Part 15: 2005, Subpart C (Section: 15.231(a))

A manually operated transmitter shall employ a switch that will automatically
deactivate the transmitter within not more than 5 seconds of being released.


4.2.2      TEST INSTRUMENTS

     Description & Manufacturer          Model No.        Serial No.         Calibrated Until

         SIGNAL ANALYZER
                                             FSP           E1S1002            Mar. 16, 2008
          Rohde & Schwarz

     Logarithmic Periodic Antenna
                                             LP1           E1A1008            Oct. 20, 2008
            Sunol Sciences

NOTE: The calibration interval of the above test instruments is 12 months.



4.2.3      TEST PROCEDURES

1      The EUT was placed on the turning table.
2      The signal was coupled to the spectrum analyzer through an antenna.
3      The transmission duration was measured and recorded.


4.2.4      DEVIATION FROM TEST STANDARD

No deviation.


4.2.5      TEST SETUP


                                        1 meter                               SPECTRUM
                            EUT                                               ANALYZER




Report No.: 071114FIA01                            9


FCC ID: VTO0711RG01-1T



4.2.6      TEST RESULTS
                       Frequency                 Transmission duration                      Maximum limit
  Push button                                                                                                            Pass / Fail
                         (MHz)                           (sec)                                  (sec)
           1                434.032                               0.99                               5                     PASS

           2                434.032                                 1                                5                     PASS


Button 1

                                                                              RBW 10 kHz    Delta 2 [T1 ]
                                                                             * VBW 30 kHz               2.00 dB
                            Ref -20 dBm             * Att       10 dB         SWT 5 s             990.000000 ms
                            -20                                                             Marker 1 [T1 ]
                                                                                                      -97.58 dBm
                                                                                                  807.500000 ms    A
                            -30

                   1 PK *
                   VIEW
                            -40



                            -50



                            -60
                                                                                                                   PRN

                            -70



                            -80



                            -90
                                                            2
                                          1

                            -100



                            -110


                            -120

                            Center 434.032 MHz                          500 ms/



                  Date:            15.NOV.2007    08:56:52



Button 2




Report No.: 071114FIA01                                                 10


FCC ID: VTO0711RG01-1T

                                                                          RBW 10 kHz        Delta 2 [T1 ]
                                                                         * VBW 30 kHz                   0.23 dB
                            Ref -20 dBm            * Att    10 dB         SWT 5 s                   1.000000 s
                            -20                                                             Marker 1 [T1 ]
                                                                                                      -96.35 dBm
                                                                                                    2.437500 s     A
                            -30

                   1 PK *
                   VIEW
                            -40



                            -50



                            -60
                                                                                                                   PRN

                            -70



                            -80



                            -90
                                                                     1                  2

                            -100



                            -110


                            -120

                            Center 434.032 MHz                      500 ms/



                  Date:            15.NOV.2007   08:57:42




Report No.: 071114FIA01                                             11


FCC ID: VTO0711RG01-1T


4.3 RADIATED EMISSION MEASUREMENT

4.3.1 LIMITS OF RADIATED EMISSION MEASUREMENT

 TEST STANDARD:
 FCC Part 15: 2005, Subpart C (Section: 15.205)
 FCC Part 15: 2005, Subpart C (Section: 15.209)
 FCC Part 15: 2005, Subpart C (Section: 15.231(b))


  According to 15.231 the field strength of emissions from intentional radiators
  operated under these frequencies bands shall not exceed the following:


   Fundamental            Field Strength of Fundamental            Field Strength of Spurious
 Frequency (MHz)
                            uV/meter          dBuV/meter            uV/meter          dBuV/meter
    40.66 – 40.70             2250                67.04                225               48.04
       70 – 130               1250                61.94                125               41.94
      130 – 174           1250 to 3750       61.94 to 71.48        125 to 375        41.94 to 51.48
      174 – 260               3750                71.48                 75               37.50
      260 – 470           3750 to 12500      71.48 to 81.94        375 to 1250       51.48 to 61.94
     Above 470               12500                81.94               1250               61.94
  NOTE:
  (1) Where F is the frequency in MHz, the formula for calculating the maximum permitted
      fundamental field strengths are as follows: for the band 130-174 MHz, uV/m at 3 meters =
      56.81818(F)-6136.3636; for the band 260-470 MHz, uV/m at 3 meters = 41.6667(F)- 7083.3333.
      The maximum permitted unwanted emission level is 20 dB below the maximum permitted
      fundamental level.
  (2) The above field strength limits are specified at a distance of 3meters. The tighter limits apply at
      the band edges.




Report No.: 071114FIA01                            12


FCC ID: VTO0711RG01-1T


    Emissions radiated outside of the specified bands, shall be according to the
    general radiated limits in 15.209 as following:

             Frequencies                  Field strength            Measurement distance
                 (MHz)                  (microvolts/meter)                (meters)

             0.009-0.490                    2400/F(kHz)                        300
             0.490-1.705                   24000/F(kHz)                         30
              1.705-30.0                         30                             30
                 30-88                          100                              3
                88-216                          150                              3
                216-960                         200                              3
              Above 960                         500                              3
      As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
      average detector, however, the peak field strength of any emission shall not exceed the
      maximum permitted average limits, specified above by more than 20dB under any condition of
      modulation.




      FREQUENCY RANGE OF RADIATED MEASUREMENT
      (For intentional radiators)

      If the intentional radiator operates below 10 GHz: to the tenth harmonic of the
      highest fundamental frequency or to 40 GHz, whichever is lower.




Report No.: 071114FIA01                           13


FCC ID: VTO0711RG01-1T




4.3.2 TEST INSTRUMENTS
        DESCRIPTION &                                                          CALIBRATED
                                     MODEL NO.             SERIAL NO.
        MANUFACTURER                                                             UNTIL
           Test Receiver
                                       ESCS30                E1R1001           Apr. 19, 2008
      ROHDE & SCHWARZ
          BILOG Antenna
                                      VULB9168               E1A1001           Sept. 26, 2008
         SCHWARZBECK
            Preamplifier
                                        8447D                E1A2001           Jan. 27, 2008
               Agilent
            Preamplifier
                                         8449B               E1A2002           Jan. 27, 2008
               Agilent
   Double Ridged Broadband
           Horn Antenna              BBHA 9120D              E1A1002           Feb. 15, 2008
           Schwarzbeck
       *Spectrum Analyzer
                                        E4403B               E1S1001           Jan. 13, 2008
               Agilent
       *Spectrum Analyzer
                                          FSP                E1S1002           May. 15, 2008
      ROHDE & SCHWARZ
          RF signal cable
                                        RG-402               E1CBH01           May. 30, 2008
               Woken
          RF signal cable
                                        RG-402               E1CBH16           May. 30, 2008
               Woken
          RF signal cable
                                        RG-402               E1CBH20           May. 30, 2008
               Woken
          RF signal cable
                                        RG-412               E1CBL02           May. 30, 2008
               Woken
          RF signal cable
                                        RG-412               E1CBL03           May. 30, 2008
               Woken
          RF signal cable
                                        RG-412               E1CBL04           May. 30, 2008
               Woken
              Software
                                 ADT_Radiated_V7.5              N/A                    N/A
                 ADT
  NOTE: 1. The calibration interval of the above test instruments is 12 months.
        2. “*” = These equipment are used for the final measurement.
        3. The horn antenna and HP preamplifier (model: 8449B) are used only for the
           measurement of emission frequency above 1GHz if tested.
        4. The Spectrum Analyzer (model: FSP) and RF signal cable
           (SERIAL: E1CBH05&E1CBH07) are used only for the measurement
           of emission frequency above 1GHz if tested.


Report No.: 071114FIA01                         14


FCC ID: VTO0711RG01-1T


4.3.3 TEST PROCEDURE
 a. The EUT was placed on the top of a rotating table 0.8 meters above the ground
    at a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to
    determine the position of the highest radiation.
 b. The EUT was set 3 meters away from the interference-receiving antenna, which
    was mounted on the top of a variable-height antenna tower.
 c. The antenna is a broadband antenna, and its height is varied from one meter to
    four meters above the ground to determine the maximum value of the field
    strength. Both horizontal and vertical polarizations of the antenna are set to make
    the measurement.
 d. For each suspected emission, the EUT was arranged to its worst case and then
    the antenna was tuned to heights from 1 meter to 4 meters and the rotatable
    table was turned from 0 degrees to 360 degrees to find the maximum reading.
 e. The test-receiver system was set to Peak Detect Function and Specified
    Bandwidth with Maximum Hold Mode.
NOTE:
  1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Peak detection (PK)
     and Quasi-peak detection at frequency below 1GHz.
  2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz for Peak detection (PK) at
     frequency above 1GHz.




4.3.4 DEVIATION FROM TEST STANDARD
No deviation.




Report No.: 071114FIA01                         15


FCC ID: VTO0711RG01-1T




4.3.5 TEST SETUP




For the actual test configuration, please refer to the related Item – Photographs of the Test
Configuration.




4.3.6 EUT OPERATING CONDITIONS
Set the transmitter part of EUT under transmission condition continuously at specific
channel frequency.




Report No.: 071114FIA01                       16


FCC ID: VTO0711RG01-1T


4.3.7 TEST RESULTS
Below 1GHz Worst-Case Data

EUT                       Remote controller       MODEL NO.            RG01-1T
                                                  FREQUENCY
CHANNEL                   Channel 1                                    30 ~ 1000 MHz
                                                  RANGE
MODULATION                                        INPUT POWER
                          ASK                                 4.5 Vdc from batteries
TYPE                                              (SYSTEM)
ENVIRONMENTAL 20 deg. C, 50% RH, DETECTOR
CONDITIONS    1000 hPa           FUNCTION                              Quasi-Peak / Peak/ Average

TESTED BY                 REBECCA

          ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
           Freq.           Factor     Reading    Emission    Limit     Margin   Ant. Height   Table Angle
 No.
           (MHz)          (dB/M)      (dBuV/M)   (dBuV/M)   (dBuV/M)    (dB)       (cm)         (Deg.)
 1      233.7QP           14.61       -8.82       5.79        46       -40.21      99              7
 2      350.1QP           17.47       -8.48       8.99        46       -37.01      99             19
 3*    434.03PK           19.71       34.02      53.73      100.83      -47.1      99             0
 3*    434.98AV           19.74       19.45      39.16      80.83      -41.67      99             0
 4      602.3QP           23.17       -8.23      14.94        46       -31.06      99             59
 5     740.52QP           25.24       -8.97      16.27        46       -29.73      99            208
 6     813.27QP           26.11       -8.19      17.91        46       -28.09      99              0
 7     868.07PK           26.43       21.37       47.8      80.83      -33.03      99             0
 7     868.09AV           26.43        6.8       33.23      60.83       -27.6      99             0
 8      941.8QP           27.77       -7.59      20.18        46       -25.82      99             19




Report No.: 071114FIA01                              17


 FCC ID: VTO0711RG01-1T



             ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
             Freq.         Factor     Reading     Emission    Limit     Margin   Ant. Height   Table Angle
   No.
             (MHz)         (dB/M)     (dBuV/M)    (dBuV/M)   (dBuV/M)    (dB)        (cm)        (Deg.)
   1     190.05QP          13.44        -9         4.44       43.5      -39.06     100            162
   2     323.43QP           17.1      -8.99        8.12        46       -37.88     100            210
   3*    434.02PK          19.71      33.46       53.17      100.83     -47.66     101            19
   3*    434.04AV          19.71      18.89        38.6      80.83      -42.23     100            19
   4     478.62QP          20.56       -8.2       12.36        46       -33.64     100            111
   5      583QP            22.78      -8.72       14.07        46       -31.93     100             58
   6     711.25QP          24.81      -0.84       23.97        46       -22.03     100            313
   7      806QP            25.95      -7.99       17.96        46       -28.04     100            301
   8     868.06PK          26.43      13.55       39.98      80.83      -40.85     100             0
   8     868.07AV          26.43      -1.02       25.41      60.83      -35.42     100            19
NOTE: 1. Emission level (dBuV/m) =Raw Value (dBuV) + Correction Factor (dB)
      2. Correction Factor (dB) = Antenna Factor (dB) + Cable Factor (dB)
      3. The other emission levels were very low against the limit.
      4. Margin value = Emission level – Limit value.
      5. “*” = Fundamental frequency
      6. The average value of fundamental frequency and spurious emission is: Average = Peak value
         + 20log(Duty cycle)
       Where the duty factor is calculated from following formula:
                                                40*0.43+1.49ms
          20log(Duty cycle) = 20log                                      =-14.56dB
                                                   100ms
          please see page 21~22 for plotted duty




 Report No.: 071114FIA01                              18


FCC ID: VTO0711RG01-1T


About 1GHz Worst-Case Data

  EUT                     Remote controller      MODEL NO.         RG01-1T
                                                 FREQUENCY
  CHANNEL                 Channel 1                                1 GHz ~ 5 GHz
                                                 RANGE
  MODULATION                                     INPUT POWER
                          ASK                                4.5 Vdc from batteries
  TYPE                                           (SYSTEM)
  ENVIRONMENTAL 20 deg. C, 50% RH, DETECTOR
  CONDITIONS    1000 hPa           FUNCTION                        Peak/ Average

  TESTED BY               REBECCA


               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
             Freq.        Factor       Reading Emission   Limit    Margin   Ant. Height Table Angle
  No.
            (MHz)         (dB/M)      (dBuV/M) (dBuV/M) (dBuV/M)    (dB)       (cm)       (Deg.)
   1    1301.76PK         29.69        20.84    50.53     74       -23.47     100           67
   1    1301.76AV         29.69         6.27    35.96     54       -18.04     100           45
   2    1735.68PK         29.33        19.69    49.02    80.83     -31.81     100          345
   2    1735.68AV         29.33         5.12    34.45    60.83     -26.38     100           54
   3     2169.6PK         32.62        16.41    49.03    80.83      -31.8     100          157
   3     2169.6AV         32.62         1.84    34.46    60.83     -26.37     100          129
   4    2603.52PK         32.89        16.55    49.43    80.83      -31.4     100           48
   4    2603.52AV         32.89         1.98    34.86    60.83     -25.97     100           74
   5    3037.44PK         33.65         16.4    50.05    80.83     -30.78     100           38
   5    3037.44AV         33.65         1.83    35.48    60.83     -25.35     100           84
   6    3471.36PK         33.22         16.1    49.32    80.83     -31.51     100          181
   6    3471.36AV         33.22         1.53    34.75    60.83     -26.08     100           25
   7    3905.28PK         35.64        14.18    49.82     74       -24.18     100           67
   7    3905.28AV         35.64        -0.39    35.25     54       -18.75     100          175
   8     4339.2PK         37.37        13.67    51.05     74       -22.95     100          142
   8     4339.2AV         37.37         -0.9    36.48     54       -17.52     100          101




Report No.: 071114FIA01                          19


FCC ID: VTO0711RG01-1T



                 ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
             Freq.          Factor     Reading Emission   Limit       Margin   Ant. Height Table Angle
  No.
            (MHz)           (dB/M)    (dBuV/M) (dBuV/M) (dBuV/M)       (dB)       (cm)       (Deg.)
   1    1301.76PK           29.69       19.52    49.22         74     -24.78     100           52
   1    1301.76AV           29.69        4.95    34.65         54     -19.35     100          124
   2    1735.68PK           29.33       18.37    47.71        80.83   -33.12     100           37
   2    1735.68AV           29.33         3.8    33.14        60.83   -27.69     100           65
   3     2169.6PK           32.62       17.09    49.71        80.83   -31.12     100          171
   3     2169.6AV           32.62        2.52    35.14        60.83   -25.69     100          92
   4    2603.52PK           32.89       16.02     48.9        80.83   -31.93     100          146
   4    2603.52AV           32.89        1.45    34.33        60.83    -26.5     100          275
   5    3037.44PK           33.65        15.4    49.06        80.83   -31.77     100          103
   5    3037.44AV           33.65        0.83    34.49        60.83   -26.34     100           31
   6    3471.36PK           33.22       16.53    49.75        80.83   -31.08     100          228
   6    3471.36AV           33.22        1.96    35.18        60.83   -25.65     100          378
   7    3905.28PK           35.64       12.63    48.27         74     -25.73     100          310
   7    3905.28AV           35.64       -1.94     33.7         54      -20.3     100          154
   8     4339.2PK           37.37       13.94    51.31         74     -22.69     100           99
   8     4339.2AV           37.37       -0.63    36.74         54     -17.26     100          21
REMARKS:          1. Emission level (dBuV/m) =Raw Value (dBuV) + Correction Factor (dB/m)
                  2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                  3. The other emission levels were very low against the limit.
                  4. Margin value = Emission level – Limit value.
                  5.The average value of fundamental frequency and spurious emission is: Average =
                     Peak value + 20log(Duty cycle)
                     Where the duty factor is calculated from following formula:
                                                        40*0.43+1.49ms
                     20log(Duty cycle) = 20log                                  =-14.56dB
                                                           100ms
                     please see page 21~22 for plotted duty




Report No.: 071114FIA01                            20


FCC ID: VTO0711RG01-1T


                                                                       RBW 100 kHz    Delta 2 [T1 ]
                                                                      * VBW 300 kHz               0.24 dB
                       Ref -20 dBm               * Att   0 dB          SWT 5 ms             430.000000 µs
                       -20                                                            Marker 1 [T1 ]
                                                                                                -93.84 dBm
                                                                                                             *
                                                                                            -70.000000 µs     A
                       -30

              1 PK *
              VIEW
                       -40



                       -50                                                                                   TDF



                       -60
                                                                                                             PRN

                       -70



                       -80



                       -90                                        1        2


                       -100



                       -110


                       -120

                       Center 433.92 MHz                         500 µs/



              Date:           15.NOV.2007   08:43:38




                                                                       RBW 100 kHz    Delta 2 [T1 ]
                                                                      * VBW 300 kHz               1.74 dB
                       Ref -20 dBm               * Att   10 dB         SWT 5 ms               1.490000 ms
                       -20                                                            Marker 1 [T1 ]
                                                                                                -90.47 dBm
                                                                                             -1.060000 ms     A
                       -30
                                                                                                             SGL
              1 PK *
              CLRWR
                       -40



                       -50



                       -60
                                                                                                             PRN

                       -70



                       -80

                                                                               2
                                             1
                       -90



                       -100



                       -110


                       -120

                       Center 434.032 MHz                        500 µs/



              Date:           15.NOV.2007   09:22:41




Report No.: 071114FIA01                                          21


FCC ID: VTO0711RG01-1T

                                                                     RBW 100 kHz
                                                                    * VBW 300 kHz
                       Ref -20 dBm            * Att    10 dB         SWT 100 ms
                       -20

                                                                                     A
                       -30
                                                                                    SGL
              1 PK *
              CLRWR
                       -40



                       -50



                       -60
                                                                                    PRN

                       -70



                       -80



                       -90



                       -100



                       -110


                       -120

                       Center 434.032 MHz                      10 ms/



              Date:           15.NOV.2007   09:24:21



Note: According to the repeated test several times,the graph shows that the 100ms
window is the worst 100ms transmission that the device is capable of by calculating.




Report No.: 071114FIA01                                        22


 FCC ID: VTO0711RG01-1T


 20DB OCCUPIED BANDWIDTH MEASUREMENT

 4.3.8 LIMITS OF BAND EDGES MEASUREMENT
  TEST STANDARD:
  FCC Part 15: 2005, Subpart C (Section: 15.231(C))
The bandwidth of the emission shall be no wider than 0.25% of the center frequency
for device operating above 70 MHz and below 900 MHz.

   Fundamental Frequency (MHz)                       Limit of 20 dB Bandwidth(kHz)

                  434.032                                         1085.08



 4.3.9 TEST INSTRUMENTS
    Description & Manufacturer            Model No.        Serial No.         Calibrated Until

          SIGNAL ANALYZER
                                              FSP           E1S1002            Mar. 16, 2008
           Rohde & Schwarz

    Logarithmic Periodic Antenna
                                              LP1           E1A1008            Oct. 20, 2008
             Sunol Sciences

 NOTE: The calibration interval of the above test instruments is 12 months.




 Report No.: 071114FIA01                            23


FCC ID: VTO0711RG01-1T



4.3.10 TEST PROCEDURES
   1.     The EUT was placed on the turning table.
   2.     The signal was coupled to the spectrum analyzer through an antenna.
   3.     Set the resolution bandwidth to 100kHz and video bandwidth to 300 kHz then
          select Peak function to scan the channel frequency.
   4.     The 20dB bandwidth was measured and recorded.


4.3.11 DEVIATION FROM TEST STANDARD
No deviation.


4.3.12 TEST SETUP

                                  1 meter                        SPECTRM
                          EUT                                    ANALYZER




Report No.: 071114FIA01                     24


FCC ID: VTO0711RG01-1T



4.3.13 TEST RESULTS
                                    20 dB bandwidth                       Maximum limit
   Frequency (MHz)                                                                                          Pass / Fail
                                         (kHz)                                (kHz)
         434.032                               614                             1085.08                               PASS



The plot of test result is attached as below.

                                                                       * RBW 100 kHz   Marker 3 [T1 ]
                                                                       * VBW 100 kHz             -37.34 dBm
                          Ref -20 dBm             Att     10 dB         SWT 2.5 ms        434.032000000 MHz
                          -20                                                          Marker 1 [T1 ]
                                                                                                 -57.46   dBm
                                                                                          434.322000000   MHz    A
                          -30
                                                                   3                   Delta 2 [T1 ]
                   1 PK
                                                                                                   0.06   dB
                   VIEW
                          -40                                                            -614.000000000   kHz


                          -50
                                        2                                                   1

                          -60
                                                                                                                PRN

                          -70



                          -80



                          -90



                          -100



                          -110


                          -120

                          Center 434.032 MHz                  100 kHz/                           Span 1 MHz



                  Date:          28.NOV.2007   12:40:15




Report No.: 071114FIA01                                           25


FCC ID: VTO0711RG01-1T


  5 PHOTOGRAPHS OF THE TEST CONFIGURATION
                          Radiated Emission




Report No.: 071114FIA01            26


FCC ID: VTO0711RG01-1T


  6 PHOTOGRAPHS OF THE EUT




Report No.: 071114FIA01      27


FCC ID: VTO0711RG01-1T




Report No.: 071114FIA01   28


y
Abr corn


FCC ID: VTO0711RG01-1T




  7 APPENDIX A - INFORMATION ON THE TESTING LABORATORY

We, ADT (Shanghai) Corp., was founded in 2003 to provide our best service in EMC,
Radio, Telecom and Safety consultation. Our laboratory is accredited and approved
by the following approval agencies according to ISO / IEC 17025 (2005).

The client should not use it to claim product endorsement by CNAS, A2LA, or any
government agency.

Japan          VCCI
USA            FCC, A2LA
Norway         DNV
China          CNAS

Copies of accreditation certificates of our laboratory obtained from approval agencies
can be downloaded from our web site: www.cnadt.com
If you have any comments, please feel free to contact us at the following:


   ADT (Shanghai) Corporation
   TEL :86-21-6465-9091
   Fax : 86-21-6465-9092
   Email: service@adt-sh.com
   Web Site: www.cnadt.com




Report No.: 071114FIA01                   30


FCC ID: VTO0711RG01-1T



8 APPENDIX B – UNCERTAINTY IN EMC MEASUREMENT

As specified in CISPR 16-4-2, measurement instrumentation uncertainty shall be
taken into account when determining compliance or non-compliance with a
disturbance limit. A disturbance limit shall be determined in the following manner:

If Ulab is less than or equal to Ucispr in table 1, then:
※ Compliance is deemed to occur if no measured disturbance exceeds the
     disturbance limit;
※ Non-compliance is deemed to occur if any measured disturbance
     exceeds the disturbance limit.

If Ulab is greater than or equal to Ucispr in table 1, then:
※ Compliance is deemed to occur if no measured disturbance, increased by (Ulab
     -Ucispr), exceeds the disturbance limit;
※ Non-compliance is deemed to occur if any measured disturbance, increased by
     (Ulab -Ucispr), exceeds the disturbance limit.

                                    Table 1 – Values of Ucispr

                               Measurement                                            Ucispr
                                                              (9kHz – 150kHz)
   Conducted disturbance (mains port)                       (150kHz – 30MHz)       4,0 dB 3,6 dB

   Disturbance power                                        (30MHz – 300MHz)          4,5 dB

   Radiated disturbance (electric field strength on        (30MHz – 1000MHz)          5,2 dB
   an open area test site or alternative test site)
   Other                                                                        Under consideration

ADT Shanghai hereby declare the U lab value are as the following:

Conducted test performed at SR1 shielded room with Ulab values: +/- 3.04 dB
Radiated test performed at SAC Chamber with Ulab values: +/- 4.62 dB

Based on the above specification, the Ulab values of our sites are less than Ucispr in
table 1 and compliance is deemed to occur if no measured disturbance exceeds the
disturbance limit.




Report No.: 071114FIA01                               31



Document Created: 2007-11-29 14:35:32
Document Modified: 2007-11-29 14:35:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC