user manual3

FCC ID: VQK-F08B

Users Manual

Download: PDF
FCCID_1261042

   F-08B_EN_FCC




                                                                                              Waterproofness
                                                                                              F-08B is provided with the following waterproofness by firmly
  FeliCa reader/writer                                                                        closing the external connection jack cap, installing the back cover
・ FeliCa reader/writer function of FOMA terminal uses weak waves requiring no                 and locking the cover.




                                                                                                                                                                                     Introduction
   licenses for radio stations.                                                               ・ IPX5 (Former JIS protection code 5)*1
・ It uses 13.56 MHz frequency band. When using other reader/writers in your                   ・ IPX8*3 that is a higher standard than IPX7 (former JIS protection
   surroundings, keep FOMA terminal away sufficiently from them. Before using
                                                                                                code 7)*2
   the FeliCa reader/writer, confirm that there are no radio stations using the same
   frequency band nearby.
                                                                                              *1 Code IPX5 means that a phone keeps functioning after directly applying a
                                                                                                    jet flow of 12.5 L/min. for at least 3 minutes from a distance of 2.5-3 m on a
  CAUTION                                                                                           rotating turntable.
                                                                                              *2 Code IPX7 means that a phone keeps functioning after it is slowly
・ Do not use a remodeled FOMA terminal. Using a remodeled terminal violates
                                                                                                    submerged to depth of 1 m in static tap water at room temperature, left there
  the Radio Law.
  FOMA terminal is certified according to technical standard conformance of
                                                                                                    for 30 minutes and then taken out.
  specified wireless equipment based on the Radio Law, and as a proof of it, the              *3 Code IPX8 means that it provides waterproofness of which exceeds of IPX7
  "Technical Compliance Mark " is depicted on the engraved sticker of FOMA                          standard.
  terminal.
  If you remodel FOMA terminal by removing its screws, your certification of                    F-08B provides the following waterproof performances of IPX8.
  technical standard conformance becomes invalid.                                               ・ F-08B keeps functioning after it is slowly submerged to depth of 1.5
  Do not use FOMA terminal with its certification of technical standard conformance               m in static tap water at room temperature, left there for 30 minutes
  invalid as it violates the Radio Law.                                                           and then taken out.
・ Be careful when you use FOMA terminal while driving a car etc.                                ・ The mobile phone keeps shooting still images or moving pictures in
  Using a mobile phone while driving is subject to penal regulations.                             30 minutes in static tap water at room temperature.
  If you inevitably receive a call, tell the caller that you will "call back" by handsfree,
  then park in a safe place and call back.
・ Use FeliCa reader/writer function only in Japan.
  FeliCa reader/writer function of FOMA terminal conforms to Japanese radio
  standards.
  If you use this function overseas, you may be punished.




                                                                                                                                                                                       15


                F-08B_EN_FCC




               ✜ What you can do with waterproofness of F-08B                           To ensure waterproofness
               ・ You can talk or watch 1Seg programs without using an umbrella in       To avoid water ingress, be sure to observe the points below.
Introduction


                 the rain (for rainfall of 20 mm or less per hour).                     ・ Do not throw any liquid other than room-temperature tap water on
                 - When your hands or FOMA terminal are wet, avoid installing/            FOMA terminal, or soak it in such liquid.
                   removing the back cover or opening/closing the external              ・ Open/close the external connection jack cap as described below.
                   connection jack cap.                                                   <Opening the external connection jack cap>
               ・ You can also shoot still images and moving pictures in the pool          Place your finger at groove on the hinge side to open the cap.
                 depth of 1.5 m.
                 - Do not perform other operations underwater than shooting still
                   images and moving pictures.
                                                                                             Groove on the hinge side
                 - If you put the terminal in water of swimming pool, be sure to have
                   it within 30 minutes.
                 - If FOMA terminal gets wet with water from the swimming pool,
                   wash it in after-mentioned procedure and drain the water as
                   predefined (⇒P18).                                                     <Closing the external connection jack cap>
               ・ You can use FOMA terminal in a bathroom.                                 Close with the tab for the back cover at the rear side of the cap fitted
                 - Do not put the terminal in the bathtub. Do not use the terminal in     into the concave of this terminal. Make sure that the cap is
                   hot water. Doing so may cause malfunction.                             completely closed without slack.
                 - Never put FOMA terminal in hot spring water or water containing
                   soap, detergent or bath powder.
               ・ You can immerse FOMA terminal in static water of wash bowl and                                                                 Tab on the back
                 wash dirt out with shaking the terminal.                                                                                       side cover
                 - Install the back cover and with it locked, holding the external
                   connection jack cap not to be opened and wash it with your hands
                   not using brush, sponge, etc.




16


   F-08B_EN_FCC




・ Install the back cover as described below.                                      ・ The external connection jack cap and the rubber packing of the inner
  <Installing the back cover>                                                       lid play an important role for keeping waterproof performance. Do
  Align 8 tabs of the back cover with concaves of FOMA terminal.                    not remove or scratch it. Also, prevent dust from adhering to it.




                                                                                                                                                                   Introduction
  While pressing the back cover in the direction of a so that there is
  no gap between FOMA terminal and back cover, slide the back cover                To keep the FOMA terminal waterproof, replacement of parts is
  in the direction of b to install, then slide the back cover lever in the         required every 2 years regardless of whether FOMA terminal appears
  direction of c to lock.                                                          normal or abnormal. DOCOMO replaces the parts as a chargeable
                                                                                   service. Bring FOMA terminal to a sales outlet such as a DOCOMO-
                              Back cover                                           specified repair office.


                                                                                  Important precautions
                                                                                  Do not perform actions shown in the illustrations below.
                                           b
                                                                                    <Example>
                                      a



                                                                                          Using Soap/Detergent/ Applying strong water flow   Using in hot spring
                                               Lever                                           Bath power




  * Make sure that the back cover is completely closed without slack. Slide the
     back cover in the direction of the arrow shown on the lever, and then make                       Soaking in ocean water   Soiling with sand/mud
     sure the cover is securely locked before using.
・ Securely lock the back cover and firmly close the external connection
                                                                                  Observe the following precautions to use FOMA terminal properly.
  jack cap. Even a fine obstacle (one hair, one grain of sand, tiny fiber,        ・ Accessories and optional devices are not waterproof. When
  etc.) put between contact surfaces may allow water to enter.                      watching 1Seg etc. with FOMA terminal installed in the included
・ Do not poke the microphone, earpiece or speaker with a swab or                    desktop holder, do not use it in a bath room, shower room, kitchen
  sharp object.                                                                     or lavatory even if it is not connected to the AC adapter.
・ Do not let FOMA terminal fall. It may become scratched causing the
  waterproof performance to degrade.                                                                                                                                 17


                F-08B_EN_FCC




               ・ Do not apply water flow stronger than allowed (⇒P15) (e.g., such
                 water flow that gives you pain when applied to your skin directly        DOCOMO does not guarantee actual operations under all states.
                 from a faucet or shower). F-08B provides the following waterproof        Malfunctions deemed to be caused by inappropriate operation by the
Introduction



                 performances of IPX5. However, it causes malfunction.                    customer are not covered by the warranty.
               ・ Do not put FOMA terminal in hot water, use it in a sauna or apply hot
                 airflow (from a hair dryer etc.) to it.
               ・ Do not move in water or slam the terminal against the surface of         Draining the water from FOMA terminal
                 water with FOMA terminal opened.                                        When FOMA terminal is wet, water may flow out after wiping it off;
               ・ If you put the terminal in tap water or in water of swimming pool, be   drain the water in the following steps.
                 sure to have it within 30 minutes.
                                                                                         a Wipe FOMA terminal surface with dry, clean cloth etc.
               ・ When you use the terminal in swimming pool, obey rules of the
                 facility.
               ・ FOMA terminal does not float on water.
               ・ Do not leave water on FOMA terminal. May short-circuit the power
                 jacks, or in a cold region, water may freeze causing malfunction.
               ・ Do not leave water on the microphone, earpiece or speaker. Such
                 water may interfere with talking.
               ・ If the back cover is damaged, replace it. Water may enter inside from
                 a damaged section causing troubles such as electric shocks or
                 corrosion of the battery.
               ・ If FOMA terminal gets wet with water or other liquids with the
                 external connection jack cap or back cover open, the liquid may get
                 inside the terminal causing electric shocks or malfunction. Stop
                 using FOMA terminal, turn the power OFF, remove the battery pack
                 and contact a DOCOMO-specified repair office.
               ・ If rubber gasket on the external connection jack cap or inner lid is
                 damaged or deformed, replace it at DOCOMO-specified repair office.




18


  F-08B_EN_FCC




b Shake FOMA terminal approximately 20 times, firmly holding its           d Remove the back cover and wipe off any drops of water around
  hinge section, until there is no more water splattering.                   the inner lid and the rear side of the back cover. Never open the
                                                                             inner lid. After wiping off the water, install and lock the back




                                                                                                                                                   Introduction
                                   To drain water off the speaker, shake
                                   FOMA terminal with the speaker upward     cover.
                                                                            Removing back cover ⇒P21

                                                                                              Around the inner lid




c Softly press dry, clean cloth etc., against FOMA terminal to wipe
  off water remaining in the microphone, earpiece, speaker, keys,
  hinges or charging jack.
                                                                                                                     Rear side of the back cover

                                                                           e Wipe off water drained from FOMA terminal with dry, clean cloth
                                                                             etc., and dry naturally.
                                                                            ・ Water, if any, remaining in FOMA terminal may ooze up after
                                                                              wiping off.
                                                                            ・ Do not wipe off water remaining in concaves directly with a cotton
                                                                              swab etc.




                                                                                                                                                     19


                F-08B_EN_FCC




                Charging
               Check the following before and after charging.
Introduction



               ・ Check that FOMA terminal is not wet. Never try to charge the battery
                 pack when FOMA terminal is wet.
               ・ Accessories and optional devices are not waterproof.
               ・ When charging the battery when or after FOMA terminal is wet,
                 adequately drain it and wipe off water with a dry, clean cloth etc.,
                 before connecting the included desktop holder or opening the
                 external connection jack cap.
               ・ When the external connection jack cap is opened for charging, close
                 the cap firmly after charging. It is recommended that the desktop
                 holder be used for charging to prevent water from seeping inside
                 from the external connection jack.
               ・ Do not use the AC adapter or desktop holder in a bathroom, shower
                 room, kitchen, lavatory or other highly humid area. May cause fire or
                 electric shock.
               ・ Do not touch the AC adapter or desktop holder with wet hands. May
                 cause electric shock.




20


  F-08B_EN_FCC




Before Using
Attaching UIM (FOMA card)/battery pack
After turning power OFF, close FOMA terminal and hold it in your                    ✜ Installing battery pack
hand so that you can properly attach UIM/battery pack.                              With the label side of the battery pack upward, align convex parts of the battery pack
                                                                                    with concave parts of FOMA terminal and slide the battery pack in the direction of
✜ Removing Back Cover                                                               a, press the battery pack in the direction of b to set it in and close the inner lid.
Slide the lever in the direction of a to unlock, pressing the back cover with a
                                                                                                                                                      Convex parts
thumb and slide approximately ● mm in the direction of b to remove. Pinch                                           b
the tab of inner lid and hold it up in the direction of c to open until it stops.                             a




                                                                                                                                                                             Basic Operation
                                  Press here with your thumb
        Lever

                                                                                               Battery pack             Concave parts

                                                                                    ✜ Installing back cover
                                                               Back cover           Place the 4 tabs of back cover to the notches, press back cover in the
                                                                                    direction of a to avoid forming any clearance between FOMA
✜ Installing UIM                                                                    terminal and back cover, then slide it in the direction of b to install it.
Pull the tab with your nail and pull out the tray until it clicks (a). Hold                                       Back cover
UIM with the IC side down, align the beveled corner with the tray (b)
and push into the tray until it stops (c).                                                                                     b
                 Tab                                                                                                           a
                              UIM

                             IC                                                                                                         Lever

                                                                                     Point
           a
                                                                                    ・ The inner lid is designed to be closed firmly to maintain waterproofness.
                                      Corner cut                                      Note that forcibly opening may hurt your nail or finger.
                 Tray                                                               ・ To avoid damage by forcible opening, hinge of the inner lid (joint part to
                                                                                      terminal body) is designed to be removed. If it is removed, align the pin metal
 Point                                                                                of the inner lid with groove of FOMA terminal and push it until it clicks.
・ UIM (blue) is not available for this FOMA terminal. If you have the UIM
  (blue), bring it to a docomo Shop.
                                                                                                                                                                                21


                   F-08B_EN_FCC




                  Before Using
                  Charging
                  The battery pack does not have a full charge at time of purchase.
                  Use AC adapter for FOMA terminal to charge the battery before               Charging using AC adapter
                  using FOMA terminal.                                                       a Open jack cap (a) of FOMA terminal, hold the
                                                                                               connector horizontally with the arrow side upward and
                   Using desktop holder and AC adapter in                                      insert it to the jack. (b)
                   combination for charging                                                  b Unfold the power plug and insert it into a 100V AC
Basic Operation




                  a Insert the AC adapter to the attached desktop holder,                      outlet.
                    with the arrow on the AC adapters connector upward.                          * Check that the light turns on.
                  b Unfold the AC adapters power plug and insert it into a                   c When charging is over, pull out the power plug from
                    100V AC outlet.                                                            the outlet, and pull out from FOMA terminal
                  c With FOMA terminal closed, insert it into the desktop holder.              horizontally while pressing the release buttons on both
                     * Check that the light turns on.                                          sides of the connector.
                  d After charging is completed, remove FOMA terminal
                    from the desktop holder.
                                            AC adapter              100V AC outlet
                                                                                                                                    Light
                                                                                                                                                         100V AC outlet
                         Light                                                                                                              Power plug
                                                                                                         Connector
                                                          Power plug
                                              Release              Insert at the back side        Release buttons
                                              buttons                                                                External
                                                                                                                     connection             AC adapter
                                       Connector                                                                     jack       Jack cap


                                                                                             ✜ Operations for charging
                                                                                             When charging starts, a charge start alert sounds. While charging, the
                                                                                             light turns on and the battery icons on the display and the sub-display
                                             Desktop holder
                                                                                             blink. When charging is over, a charge completion alert sounds.
22


  F-08B_EN_FCC




Before Using                                                                        Before Using
Turning power ON - Configuring default setting                                      User information
Perform the following operations after turning the power ON for                     Check your own phone number.
the first time.                                                                     For details of checking/changing a mail address, refer to "Mobile
a f (2 sec. or more)                                                                Phone User's Guide [i-mode] FOMA version".
b "Yes" or "No" on a confirmation                                                   a me0 User information
  screen of enlarged menu setting                                                      The screen shown to the right appears.
    The screen shown to the right appears.




                                                                                                                                                            Basic Operation
c Set required itemseC
  [Complete]
    Always set Change security code and
    Request permit/deny. If you exit without
    setting, Initial setting screen reappears            <Initial setting screen>
    when the power is turned ON the next                                                                                                <User information
    time.                                                                                                                               screen>

d g on a confirmation screen of software update                                      Point
  function                                                                          Editing user information : On User information edit screen, Ce
                                                                                      AuthenticateeEditeC
    The stand-by display appears.
                                                                                    Checking a phone number during a call : se0
 Point
・ If no operation is performed, the display light is turned off automatically
 according to the settings in Light time-out or Power saver setting. The
 display light turns on again if there is any operation or incoming call.
Turning power off : f (2 sec. or more)
Changing the initial setting : mehgeg
Changing screen display to English : mehbfceSelect "English"




                                                                                                                                                               23


                   F-08B_EN_FCC




                  Screen Explanation
                  Viewing display
                  The current state can be checked by the icon appearing on the screen. Major icons are as follows.
                                                                       : The total calls cost exceeds the limit   : Unreceived i-mode mail exists in i-
                   Top of the display                                   : Communication using handsfree-         mode Center
                  Battery level (Battery icon)                          compatible device in progress            : Displaying SSL/TLS page etc.
                                                                        : Handsfree ON                           : Auto-send mail exists
                     Ample                        Almost exhausted      : eco mode ON                            : Music&Video Channel program
Basic Operation




                     charge                      (Charge the battery)    : Lock on close or Lock when immobile   obtaining reservation exists
                  Signal strength (Antenna icon)                        ON                                       : During i-αppli operation
                                                                         : Kid-safe mode ON                      : i-αppli call exists
                                                                         : A phonebook entry or schedule has     : Alarm clock ON
                                          Out of service area or where  secret attribute                         : Schedule reminder ON
                    Strong           Weak
                                          radio waves do not reach
                                                                          : High-pitched alarm ON                  : Inside OFFICEED area
                       : Self mode ON                                    : Unread Area Mail exists
                       : In data transfer mode                             : Unread i-mode mail exists
                   : Connecting to i-mode                                : Arrival i-concier information exists
                   : Infrared communication in operation


                                                                   : In Public mode (Drive mode)                  : i-αppli Auto start failed
                  Bottom of the display                            : Record message ON                            : microSD card installed during
                                                                   : Keypad dial lock ON                         Communication mode
                                                                   : Personal data lock ON                        : Connected to external device using
                  Arrival information (Starting from the left,
                                                                   : Music&Video Channel program                 USB cable
                  missed call, recorded message, voice mail
                                                                   obtaining failure                              : Pedometer/ACT monitor is set
                  service, unread message, unread ToruCa,
                                                                   : Reading UIM                                  : Software update rewrite notice
                  i-αppli call)
                                                                   : IC card lock ON                              : Auto-update of latest pattern definition
                     : Silent mode ON
                                                                   : Available multi-cursor key                  failure
                     : Call alert volume OFF
                                                                   : Performing 1Seg recording reservation
24                   : Vibrator for voice call ON


  F-08B_EN_FCC




                                                                         Screen Explanation
                                                                         Viewing sub-display and light
Task area                                                                Even when FOMA terminal is closed, the
                                                                         icons in the sub-display and light provide
The icon indicating the function
                                                                         information. When no operation is
(task) in progress appears in the
                                                                         performed for a certain period of time, the
task area.
                                                             Task area   sub-display light is turned off, but it turns on again when you press
                                                                         either side key.
                                     <Vertical display>




                                                                                                                                                   Basic Operation
                                                                         ✜ Switching views
                                                                         Each time you press M, the view switches in the order of icon and
                                                                         clock ⇒ date and clock ⇒ big clock. When "Use" is set to Set
                                                                         Pedometer/Activity monitor, each time you press S, the view switches
                                            <Horizontal display>         in the order of steps ⇒ activity ⇒ clock.
                                                                         ✜ Arrival information
Guide area and key operation                                             When a missed call, recorded message, unread message, or voice
Operations that can be performed                Guide area
                                                                         message of Voice Mail service, etc. exists, press D with clock
                                                                         displayed to display the number of calls or messages, and then press
by pressing m, a, g, C
                                                                         S to scroll reception date/time and information about the senders.
and I are displayed in the
guide area. To perform an                                                ✜ Light
operation in the guide area, press                                       The light turns on or blinks when the battery charges, the camera is
                                                                         activated, light alert (⇒P39) is set, etc.
the corresponding key.
   on the guide area corresponds
to multi-cursor keys k.




                                                                               Information
                                                                          ・ The light on the sub-display turns on just by tilting FOMA terminal.
                                                                           【   背面自動点灯設定 (Auto light on)】
                                                                                                                                                      25


                   F-08B_EN_FCC




                  Screen Explanation
                  Menu operation
                  On the stand-by display, press m and then perform the
                  functions from the menu. You can select a menu item with                       Switching menu screens
                  shortcut operations, which use the keypad, * and #, or with                   You can switch among "Kisekae menu", the design of which can be
                  multi-cursor operation, which uses the multi-cursor key to move               changed using Kisekae Tool (⇒P39), "Basic menu", which has the
                  the cursor.                                                                   fixed menu numbers, and "Custom menu", to which menu items
                  <Example> Selecting "Calculator"                                              can be saved freely.
Basic Operation




                  Shortcut operations                                                           A Kisekae menu matched with the color of FOMA terminal is set by
                                                                                                default.
                  a me7e4


                                  m                   7                   4                                           I                       C




                  Multi-cursor key operations                                                        <Basic menu>            <Kisekae menu>           <Custom menu>

                  a meMove the cursor to "g Accessory"eg                                         Point
                    [Select]                                                                    ・ In some types of Kisekae menus, the menu structure is changed according
                    eMove the cursor to "d Calculator"eg [Select]                                 to usage frequency, or the number assigned to menu item (item number)
                                                                                                  may not be applicable.
                   Point                                                                        ・ The menu that appears when m is pressed on the stand-by display can
                  ・ Even when a function is running, you can perform the same operation if        be changed from the start menu. ⇒ P35
                   "MENU" is displayed on the guide area.
                  ・ To return to the previous screen, press c. To return to the stand-by
                   display, press f.
                  ・ On the stand-by display with Info/calendar layout, Shortcut icons set, or
                   with arrival information icon or i-concier information displayed, press g
                   to change the display to Focus mode that allows you to quickly display the
26                 related information.


  F-08B_EN_FCC




Screen Explanation                                                       Screen Explanation
Motion sensor                                                            使いかたガイド (Guide)
You can operate FOMA terminal by double-tapping (tapping it              You can check overviews and operations of functions, and
twice) or tilting it.                                                    troubleshooting. (In Japanese only)
✜ Stopping an alarm/displaying details of arrival                        a mef LifeKite* GuideeSelect
   information                                                             a search method
When FOMA terminal is closed and the alarm sounds, double-tapping            目次 (Contents) : Search from a list of
the front or back side stops the alarm. When the clock is displayed on        functions.




                                                                                                                                                      Basic Operation
the sub-display, double-tapping the side displays details of arrival         索引 (Index) : Search from a list of words
information.                                                                  sorted according to Japanese syllabary.
                             Front                 Back
                                                                             フリーワード検索 (Free word search) :
                                                                              Enter a keyword to search for.
                                                                             ブックマーク (Bookmark) : Search from a
                                                                                                                      <Guide screen>
                                                                              list of registered bookmarks.
                                            Side                Side         困ったときには (Troubleshooting) : Search from lists of
                                                                              troubles or error messages.
✜ Tilting FOMA terminal
Tilting FOMA terminal while pressing and holding S or D when              Point
Browser screen is displayed scrolls the screen or switches the           ・ On a description screen, select "この機能を使う (Use this function)" to
orientation of view for the clock on the sub-display.                      perform a function. Selecting a link item in "関連機能 (related functions)",
                                                                           or "→コチラ (See more)" displays a corresponding description screen.
 Setting Motion sensor                                                   ・ Terms indicated with 【 】in this manual are index terms in "Guide".

a meh Settings & NW serviceeg Clock &
  Otheref Motion sensorea ON or b OFF




                                                                                Information
                                                                          ・ You can also access フリーワード検索 from クイック検索. ⇒P104                              27


                   F-08B_EN_FCC




                   Caller ID notification (At subscription : Notify)
                  You can notify your phone number (caller ID) to the other party's
                  terminal when making a voice call.
                  a meh Settings & NWserviceseh NW Servicese
                    d Caller IDea Caller ID notificationea Activate/
Basic Operation




                    Deactivateea Notify
                      Select "b Not notify" if you do not want to inform.
                   Point
                  ・ Caller ID is your important personal information. Carefully consider
                   whether you want to include caller ID information when making a call.
                  ・ If an announcement of requesting caller ID is heard when making a call,
                   make a call again after setting Caller ID notification or adding prefix "186".




28


           F-08B_EN_FCC




          Appendix
          Specific absorption rate (SAR) of mobile phone
          This model phone FOMA F-08B meets the MIC's*1 technical regulation                 *1 Ministry of Internal Affairs and Communications.
          governing exposure to radio waves.                                                 *2 The technical regulation is provided in Article 14-2 of the Ministry Ordinance
          The technical regulation established permitted levels of radio frequency              Regulating Radio Equipment.
          energy, based on standards that were developed by independent scientific           *3 International Commission on Non-Ionizing Radiation Protection.
          organizations through periodic and thorough evaluation of scientific studies.
          The regulation employs a unit of measurement known as the Specific                     Declaration of Conformity
          Absorption Rate, or SAR. The SAR limit is 2 watts/kilogram (W/kg)*2 averaged
          over 10 grams of tissue. The limit includes a substantial safety margin designed
          to assure the safety of all persons, regardless of age and health. The value of        The product "F-08B" is declared to conform with the essential requirements of
                                                                                                 European Union Directive 1999/5/EC Radio and Telecommunications Terminal
          the limit is equal to the international guidelines recommended by ICNIRP.*3
                                                                                                 Equipment Directive 3.1(a), 3.1(b) and 3.2.The Declaration of Conformity can be
          All phone models should be confirmed to comply with the regulation, before
                                                                                                 found on http://www.fmworld.net/product/phone/doc/.
          they are available for sale to the public. The highest SAR value for this FOMA
          F-08B is 1.440 W/kg. It was taken by the Telecom Engineering Center (TELEC).
          The test for SAR was conducted according to the MIC testing procedure using        This mobile phone complies with the EU requirements for exposure to radio
          standard operating positions with the phone transmitting at its highest            waves.
          permitted power level in all tested frequency bands. While there may be            Your mobile phone is a radio transceiver, designed and manufactured not to
          differences between the SAR levels of various phones and at various positions,     exceed the SAR* limits** for exposure to radio-frequency(RF) energy, which
          they all meet the MIC's technical regulation. Although the SAR is determined at    SAR* value, when tested for compliance against the standard was 1.410W/Kg.
          the highest certified power level, the actual SAR of the phone during operation    While there may be differences between the SAR* levels of various phones and
          can be well below the maximum value.                                               at various positions, they all meet*** the EU requirements for RF exposure.
          For further information about SAR, please see the websites below.                  *   The exposure standard for mobile phones employs a unit of measurement
                                                                                                 known as the Specific Absorption Rate, or SAR.
           World Health Organization (WHO) :                                                 ** The SAR limit for mobile phones used by the public is 2.0 watts/kilogram (W/
           http://www.who.int/peh-emf/en/                                                        Kg) averaged over ten grams of tissue, recommended by The Council of the
           ICNIRP :
                                                                                                 European Union. The limit incorporates a substantial margin of safety to give
 Others




           http://www.icnirp.de/
                                                                                                 additional protection for the public and to account for any variations in
           MIC :
                                                                                                 measurements.
           http://www.tele.soumu.go.jp/e/sys/ele/index.htm
                                                                                             *** Tests for SAR have been conducted using standard operation positions with
           TELEC :
           http://www.telec.or.jp/ENG/Index_e.htm                                                the phone transmitting at its highest certified power level in all tested
           NTT DOCOMO :                                                                          frequency bands. Although the SAR is determined at the highest certified
           http://www.nttdocomo.co.jp/english/product/sar/                                       power level, the actual SAR level of the phone while operating can be well
           FUJITSU LIMITED :                                                                     below the maximum value. This is because the phone is designed to operate
           http://www.fmworld.net/product/phone/sar/                                             at multiple power levels so as to use only the power required to reach the
                                                                                                 network. In general, the closer you are to a base station antenna, the lower the
132                                                                                              power output.


    F-08B_EN_FCC




                                                                                    Before a phone model is available for sale to the public, it must be tested and
    Federal Communications Commission                                               certified to prove to the FCC that it does not exceed the limit established by the
    (FCC) Notice                                                                    U.S. government-adopted requirement for safe exposure. The tests are
                                                                                    performed on position and locations (for example, at the ear and worn on the
・ This device complies with part 15 of the FCC rules.                               body) as required by FCC for each model. The highest SAR value for this model
    Operation is subject to the following two conditions :                          phone as reported to the FCC, when tested for use at the ear, is 0.854W/kg, and
    a this device may not cause harmful interference, and                           when worn on the body, is 0.821W/kg. (Body-worn measurements differ
    b this device must accept any interference received, including interference     among phone models, depending upon available accessories and FCC
       that may cause undesired operation.                                          requirements).
・   Changes or modifications made in or to the radio phone, not expressly           While there may be differences between the SAR levels of various phones and
    approved by the manufacturer, will void the user's authority to operate the     at various positions, they all meet the U.S. government requirements.
    equipment.                                                                      The FCC has granted an Equipment Authorization for this model phone with all
                                                                                    reported SAR levels evaluated as in compliance with the FCC RF exposure
    FCC RF Exposure Information                                                     guidelines. SAR information on this model phone is on file with the FCC and
                                                                                    can be found under the Equipment Authorization Search section at http://
This model phone meets the U.S. Government's requirements for exposure to
                                                                                    www.fcc.gov/oet/ea/fccid/ (please search on FCC ID VQK-F08B).
radio waves.
                                                                                    For body worn operation, this phone has been tested and meets the FCC RF
This model phone contains a radio transmitter and receiver. This model phone
                                                                                    exposure guidelines when used with an accessory designated for this product
is designed and manufactured not to exceed the emission limits for exposure
                                                                                    or when used with an accessory that contains no metal and which positions the
to radio frequency (RF) energy as set by the FCC of the U.S. Government. These
                                                                                    handset at a minimum distance of 1.5 cm from the body.
limits are part of comprehensive guidelines and establish permitted levels of RF
                                                                                    * In the United States, the SAR limit for wireless mobile phones used by the general public
energy for the general population. The guidelines are based on standards that
                                                                                       is 1.6 Watts/kg (W/kg), averaged over one gram of tissue. SAR values may vary
were developed by independent scientific organizations through periodic and
                                                                                       depending upon national reporting requirements and the network band.
thorough evaluation of scientific studies.                                          This equipment has been tested and found to comply with the limits for a Class
The exposure standard for wireless mobile phones employs a unit of                  B digital device, pursuant to part 15 of the FCC Rules.




                                                                                                                                                                                  Others
measurement known as the Specific Absorption Rate (SAR). The SAR limit set          These limits are designed to provide reasonable protection against harmful
by the FCC is 1.6 W/kg. Tests for SAR are conducted using standard operating        interference in a residential installation. This equipment generates, uses and
positions as accepted by the FCC with the phone transmitting at its highest         can radiate radio frequency energy and, if not installed and used in accordance
certified power level in all tested frequency bands. Although the SAR is            with the instructions, may cause harmful interference to radio
determined at the highest certified power level, the actual SAR level of the        communications. However, there is no guarantee that interference will not
phone while operating can be well below the maximum value. This is because          occur in a particular installation.
the phone is designed to operate at multiple power levels so as to use only the
power required to reach the network. In general, the closer you are to a wireless
base station antenna, the lower the power output level of the phone.

                                                                                                                                                                                   133


           F-08B_EN_FCC




          If this equipment does cause harmful interference to radio or television             Pacemakers
          reception, which can be determined by turning the equipment off and on, the          Pacemaker manufacturers recommend that a minimum separation of 15 cm be
          user is encouraged to try to correct the interference by one or more of the          maintained between a mobile phone and a pace maker to avoid potential
          following measures:                                                                  interference with the pacemaker. To achieve this use the phone on the opposite
              - Reorient or relocate the receiving antenna.                                    ear to your pacemaker and does not carry it in a breast pocket.
              - Increase the separation between the equipment and receiver.                    Hearing Aids
              - Connect the equipment into an outlet on a circuit different from that to       Some digital wireless phones may interfere with some hearing aids. In the
                which the receiver is connected.                                               event of such interference, you may want to consult your hearing aid
              - Consult the dealer or an experienced radio/TV technician for help.             manufacturer to discuss alternatives.
                                                                                               For other Medical Devices :
           Important Safety Information                                                        Please consult your physician and the device manufacturer to determine if
                                                                                               operation of your phone may interfere with the operation of your medical
          AIRCRAFT                                                                             device.
          Switch off your wireless device when boarding an aircraft or whenever you are
          instructed to do so by airline staff. If your device offers flight mode or similar
          feature consult airline staff as to whether it can be used on board.
          DRIVING
          Full attention should be given to driving at all times and local laws and
          regulations restricting the use of wireless devices while driving must be
          observed.
          HOSPITALS
          Mobile phones should be switched off wherever you are requested to do so in
          hospitals, clinics or health care facilities. These requests are designed to
          prevent possible interference with sensitive medical equipment.
          PETROL STATIONS
 Others




          Obey all posted signs with respect to the use of wireless devices or other radio
          equipment in locations with flammable material and chemicals. Switch off your
          wireless device whenever you are instructed to do so by authorized staff.
          INTERFERENCE
          Care must be taken when using the phone in close proximity to personal
          medical devices, such as pacemakers and hearing aids.




134


  F-08B_EN_FCC




Appendix                                                                        Appendix
Export Administration Regulations                                               Intellectual Property Right
This product and its accessories may be under coverage of the Export
Administration Regulations of Japan ("Foreign Exchange and Foreign Trade         Copyrights and portrait rights
Control Laws" and the related laws and regulations). And, they are also under   Except for the case protected by copyright laws such as personal use, use of
coverage of Export Administration Regulations of the U.S. When exporting        FOMA terminal to reproduce, alter, or publicly transmit recorded pictures or
and reexporting this product and its accessories, take necessary procedures     sounds, or copyrighted text, images, music or software downloaded from
on your responsibility and expense. For details, contact Ministry of Economy,   websites without the copyright holder's authorization is prohibited.
Trade and Industry of Japan or US Department of Commerce.                       Note that taking photos or recordings at some demonstrations, performances
                                                                                or exhibitions may be prohibited even when only for personal use.
                                                                                Avoid taking pictures of others with FOMA terminal without their consent or
                                                                                disclosing recorded pictures of others without their consent to general public
                                                                                through Internet websites etc., because they may infringe on portrait rights.

                                                                                 Trademarks
                                                                                Company and product names mentioned in this manual are trademarks or
                                                                                registered trademarks of their respective holders.
                                                                                ・ "FOMA", "i-mode", "i-αppli", "i-motion", "Deco-mail", "Chara-den", "ToruCa",
                                                                                  "mopera", "WORLD CALL", "DCMX", "WORLD WING", "OFFICEED", "2in1",
                                                                                  "docomo STYLE series" and logos of "FOMA", "i-mode", "i-αppli",
                                                                                  "Music&Video Channel", "DCMX", "iD" and "iC" are trademarks or registered
                                                                                  trademarks of NTT DOCOMO.
                                                                                ・ "Catch Phone (Call Waiting Service)" is a registered trademark of Nippon
                                                                                  Telegraph and Telephone Corporation.
                                                                                ・ Free Dial logo mark is a registered trademark of NTT Communications
                                                                                  Corporation.




                                                                                                                                                                 Others
                                                                                ・ McAfee® is registered trademarks or trademarks of McAfee, Inc. and/or its
                                                                                  affiliates in the US and/or other countries.
                                                                                ・ G-GUIDE, G-GUIDE MOBILE and their logos are registered
                                                                                  trademarks in Japan of U.S. Gemstar-TV Guide International, Inc.
                                                                                  and/or its affiliates.




                                                                                                                                                                  135


              F-08B_EN_FCC




          ・ This product contains Adobe® Flash® Lite® and Adobe Reader® LE              ・ The abbreviations of operating systems (Japanese versions) below are used
              technology of Adobe Systems Incorporated.                                     in this manual.
              Adobe Flash Lite Copyright© 2003-2010 Adobe Systems Incorporated. All         - Windows 7 stands for Microsoft® Windows® 7(Starter, Home Basic, Home
              rights reserved.                                                                Premium, Professional, Enterprise Ultimate).
              Adobe Reader Mobile Copyright© 1993-2010 Adobe Systems Incorporated.          - Windows Vista stands for Windows Vista® (Home Basic, Home Premium,
              All rights reserved.                                                            Business, Enterprise and Ultimate).
              Adobe, Adobe Reader, Flash and Flash Lite are either                          - Windows XP indicates the Microsoft® Windows® XP Professional
              registered trademarks or trademarks of Adobe Systems                            operating system or Microsoft® Windows® XP Home Edition operating
              Incorporated in the United States and/or other countries.                       system.
          ・   This product contains NetFront Browser,                                   ・   Google is registered trademark of Google Inc.
              NetFront Sync Client of ACCESS CO., LTD.                                  ・   "CROSS YOU" is a trademark of Sony Corporation.
              ACCESS, the ACCESS logo and NetFront are trademarks or registered         ・   Manufactured under license from Dolby Laboratories. Dolby and the double-
              trademarks of ACCESS CO., LTD. in the United States, Japan and/or other       D symbol are trademarks of Dolby Laboratories.
              countries.                                                                ・   ATOK + APOT of Justsystem Corporation is installed in this product as
              Copyright© 2009 ACCESS CO., LTD. All rights reserved.                         Japanese character conversion function.
          ・   Powered by JBlend™ Copyright 2002-2009 Aplix Corporation. All                 "ATOK" "APOT (Advanced Prediction Optimization Technology)" are
              rights reserved.                                                              registered trademarks of Justsystem Corporation.
              JBlend and JBlend-related trademarks are trademarks or registered         ・   This equipment is provided with the software licensed by Symbian Software
              trademarks of Aplix Corporation in Japan and other countries.                 Ltd. or the licensor©1998-2010.           and Symbian OS are trademarks of
          ・        is a registered trademark of FeliCa Networks, Inc.                       Symbian Ltd. or the licensor.
          ・   FeliCa is a registered trademark of Sony Corporation.                     ・   "Privacy mode" is a registered trademark of FUJITSU LIMITED.
          ・   QR code is a registered trademark of Denso Wave Inc.                      ・   "Uni-Type" is a registered trademark of LIM Corp., Ltd.
          ・   microSDHC logo is a trademark of D-3C,LLC.                                ・   FrameSolid is the registered trademark of Morpho, Inc. in Japan and other
          ・   "Multitask" is a registered trademark of NEC Corporation.                     countries.
          ・   QuickTime is a registered trademark of Apple Inc. in the US and other     ・   The auto object tracking technology utilized is TrackSolid™, a product of
 Others




              countries.                                                                    Morpho, Inc. TrackSolid™ is trademark of Morpho, Inc.
          ・   Microsoft®, Windows®, Windows Vista®, Windows Media® and                  ・   ズーキーパー (Zookeeper) is a trademark or registered trademark of
              PowerPoint® are trademarks or registered trademarks of "Microsoft             KITERETSU Inc.
              Corporation" in the US and other countries.                               ・   "日英版しゃべって翻訳 for F (J-E Speech Translation for F)" is trademark of
                                                                                            ATR-Trek.
                                                                                        ・   Other company and product names mentioned in this manual are
                                                                                            trademarks or registered trademarks of their respective holders.


136


    F-08B_EN_FCC




    Others
・ FeliCa is a contactless IC card technology developed by Sony Corporation.
・ This product contains a module developed by the Independent JPEG Group.
・ The image interpolation technology utilized is FrameSolid, a product of
    Morpho, Inc.
・ This product is equipped with the technologies of GestureTek, Inc.
    Copyright© 2006-2010, GestureTek, Inc. All Rights Reserved.
・ "学研モバイル国語辞典 (Gakken Mobile JpnDic)", "学研モバイル和英辞典
    (Gakken Mobile JE Dic)", "学研モバイル英和辞典 (Gakken Mobile EJ Dic)", "今
    日は何の日 (Today's trivia)" and "今日の歴史 (Today in history)" are
    copyrighted by GAKKEN CO., LTD.
・   This product is licensed based on MPEG-4 Visual Patent Portfolio License.
    The use of MPEG-4 Video Codec function is allowed for personal and
    nonprofit use only in the cases below.
    - Recording moving pictures and i-motion that conform to MPEG-4 Visual
      Standard (hereinafter referred to as MPEG-4 Video)
    - Playing MPEG-4 Videos recorded personally by consumers not engaged in
      profit activities
    - Playing MPEG-4 Video supplied from the provider licensed from MPEG-LA
      For further utilizing such as promotion, in-house use or profit-making
      business, please contact MPEG LA, LLC in U.S.
・   Content owners use Windows Media digital rights management technology
    (WMDRM) to protect their intellectual property, including copyrights. This




                                                                                 Others
    device uses WMDRM software to access WMDRM-protected content. If the
    WMDRM software fails to protect the content, content owners may ask
    Microsoft to revoke the software's ability to use WMDRM to play or copy
    protected content. Revocation does not affect unprotected content. When
    downloading licenses for protected content, you agree that Microsoft may
    include a "Revocation List" with the licenses. Content owners may require
    you to upgrade WMDRM to access their content. If you decline an upgrade,
    you cannot access a content that requires the upgrade.


                                                                                  137


         General Inquiries <docomo Information Center>                                                                                    Repairs
(Business hours : 9:00 a.m. to 9:00 p.m.)                                                         (Business hours : 24 hours (open all year round)
     0120-005-250 (toll free)                                                                     ■ From DOCOMO mobile phones           ■ From land-line phones
* Service available in: English, Portuguese, Chinese, Spanish, Korean.                            (In Japanese only)                    (In Japanese only)
* Available from mobile phones and PHSs (including non-DOCOMO phones).                                 (No prefix) 113 (toll free)                     0120-800-000 (toll free)
* Unavailable from part of IP phones.                                                             * Unavailable from land-line phones, etc.       * Available from mobile phones and PHSs.
(Business hours : 9:00 a.m. to 8:00 p.m.)                                                                                                           (including non-DOCOMO phones).
■ From DOCOMO mobile phones           ■ From land-line phones                                                                                     * Unavailable from part of IP phones.
(In Japanese only)                    (In Japanese only)
    (No prefix) 151 (toll free)                      0120-800-000 (toll free)
* Unavailable from land-line phones, etc.       * Available from mobile phones and PHSs.
                                                  (including non-DOCOMO phones).
                                                * Unavailable from part of IP phones.
● Please confirm the phone number before you dial.
● For Applications or Repairs and After-Sales Service, please contact the above-mentioned information center or the docomo shop etc. near you on the NTT DOCOMO website or the i-mode site.
 NTT DOCOMO website http://www.nttdocomo.co.jp/english/                      i-mode site iMenu⇒お客様サポート (user support)⇒ドコモショップ (docomo Shop) * In Japanese only
Loss or theft of FOMA terminal or payment of cumulative cost overseas                                                Failures encountered overseas
                    <docomo Information Center>                                                                 <Network Support and Operation Center>
(available 24 hours a day)                                                                        (available 24 hours a day)
■ From DOCOMO mobile phones                                                                       ■ From DOCOMO mobile phones
    International call access code                                                                    International call access code
    for the country you stay             -81-3-6832-6600* (toll free)                                 for the country you stay             -81-3-6718-1414* (toll free)
* You are charged a call fee to Japan when calling from a land-line phone, etc.                   * You are charged a call fee to Japan when calling from a land-line phone, etc.
※If you use F-08B, you should dial the number +81-3-6832-6600 (to enter '+',                      ※If you use F-08B, you should dial the number +81-3-6718-1414 (to enter '+',
  press and hold the '0' key for at least one second).                                              press and hold the '0' key for at least one second).
■ From land-line phones <Universal number>                                                        ■ From land-line phones <Universal number>
    International prefix number                                                                       International prefix number
    for the universal number           -8000120-0151*                                                 for the universal number           -8005931-8600*
* You might be charged a domestic call fee according to the call rate for the country you stay. * You might be charged a domestic call fee according to the call rate for the country you stay.
※For international call access codes for major countries/international prefix numbers           ※For international call access codes for major countries/international prefix numbers
  for the universal number, refer to DOCOMO International Services website.                       for the universal number, refer to DOCOMO International Services website.
● If you lose your FOMA terminal or have it stolen, immediately take the steps necessary for suspending the use of the FOMA terminal.
● If the FOMA terminal you purchased is damaged, bring your FOMA terminal to a repair counter specified by DOCOMO after returning to Japan.


             To prevent damage to the environment,
             bring used battery packs to a docomo
             service counter, a docomo agent or a            Don't forget your mobile phone ・・・ or your manners!
             recycle center.                                  When using your mobile phone in a public place, don't forget to                                          2010.X (1st Edition)
                                                             show common courtesy and consideration for others around you.                                                CA92002-XXXX



Document Created: 2010-04-02 15:29:16
Document Modified: 2010-04-02 15:29:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC