                                  RF Exposure / MPE Calculation

           No.                         :    12529842H-A
           Applicant                   :    Murata Manufacturing Co., Ltd.
           Type of Equipment           :    UHF RFID Reader/Writer
           Model No.                   :    LXRFZZUAAA-052
           FCC ID                      :    VPYLXRF052


Murata Manufacturing Co., Ltd. declares that Model: LXRFZZUAAA-052 complies with FCC
radiation exposure requirement specified in the FCC Rule 2.1091 (for mobile).

RF Exposure Calculations:

The following information provides the minimum separation distance for the highest gain antenna
provided with the “LXRFZZUAAA-052“ as calculated from (B) Limits for General Population /
Uncontrolled Exposure of TABLE 1- LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE
(MPE) of §1.1310 Radiofrequency radiation exposure limits.

This calculation is based on the highest EIRP possible from the system,
considering maximum power and antenna gain, and considering a 1mW/cm^2 uncontrolled
exposure limit. The Friis formula used was:

                   PG
          S 
Where
                  4  r2
     P=    446.68 mW (Maximum average output power)
        Time average was used for the above value in consideration of 6-minutes time-averaging
        Burst power average was used for the above value in consideration of worst condition.
     G=      0.692 Numerical Antenna gain; equal to -1.6 dBi
     r=         20 cm (Separation distance)


                                                    2
     Power Density Result S =      0.06148 mW/cm

Even taking into account the tolerance, this device can be satisfied with the limits.